• 제목/요약/키워드: time-to-contact

검색결과 3,010건 처리시간 0.031초

Pulsed Nd:YAG 레이저 조사거리에 따른 상아질의 온도변화 (Temperature Changes in Dentin upon Pulsed Nd:YAG Lasing Distance)

  • Jae-Hyung Kim;Woo-Cheon Kee
    • Journal of Oral Medicine and Pain
    • /
    • 제20권2호
    • /
    • pp.327-334
    • /
    • 1995
  • In order to observe the influence of pulsed Nd:YAG laser at its out-of-contact with dentin on tooth temperature, we have applied pulsed Nd:YAG laser to 2mm thick dentin sample at a point of contact and from a distance of 1mm, 2mm, 3mm and 4mm with an energy of 0.3W, 0.5W, 0.8W, 1.5W and 2.0W. They were exposed to periods of 3 seconds, 6 seconds, 9 seconds and 15 seconds respectively and measured temperature changes. The results as follows : 1. When the time ad intensity of power were constant, the temperature changes on dentin of tooth depended on the distance. The temperature increased when the laser intensity increased bu two other conditions were contact. 2. At the point of contact, the temperature has risen over $5^{\circ}C$ regrdless of intensity of the power or the time. However, there was $5^{\circ}C$ fluctuation with 0.3 W for 3 seconds treatment. 3. The temperature change was less than $5^{\circ}C$ thermal change at the distance of 1mm and 2mm respectively when lased for 3 seconds, 6 seconds, 12 seconds and 15 seconds with 0.3 W. Similar results were observed at 3 and 6 seconds treatment with 0.5 W and at 3 seconds treatment with 0.8 and 1.0W respectively. 4. It showed less than 5(C thermal change when lased for 3 seconds, 6 seconds, 9 seconds, 12 seconds and 15 seconds with 0.3W at the distance of 3mm and 4mm. The same results were seen in 3 seconds, 6 seconds and 9 seconds treatment with 0.5W and in 3 seconds with 0.8W and 1.0W respectively. As we have seen the above, the results has indicated that pulsed Nd:YAG lasing at its off contact on dentin of 2mm thickness will not cause irreversible changes if lasing intensity, lasing distance and lasing time are appropriate.

  • PDF

저작습관에 따른 교합접촉의 변화양태에 관한 연구 (A Study on the Effects of Chewing Side Preference on the Pattern of Occlusal Contacts)

  • Sun-Oh Kwon;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • 제15권1호
    • /
    • pp.117-124
    • /
    • 1991
  • The purpose of his study was to investigate the variations of occlusal contact pattern according to chewing side preference. The author selected 59 dental students (mean age 23.6 years) who had no signs and symptoms of masticatory disorders and divided into two groups, that is, bilateral chewing side group and unilateral chewing side group, respectively. For recording, T-Scan System(Teksan Inc., USA) was used and the recorded occlusal contacts were examined as to the number of occlusal contacts, points distribution in dental arch, time sequence and force snapshot. The obtained results were as follow s: 1. Total number of occlusal contacts were more in unilateral chewing side group and there were significant difference in number between right and left side or between chewing and less-chewing side in all two groups. 2. All items related to time sequence showed no statistical significant difference between two groups in any case. 3. Unilateral chewing side group had more occlusal contact force than bilateral group, especially in chewing side. From the above finding, the author considered that there was occlusal unbalance in unilateral chewing side group. 4. Chewing side preference would possibly have more effects on the occurrence rate of anterior tooth contact that the rate of prolonged their contact but proved.

  • PDF

일부 도서지역의 보건의료에 대한 기초조사 II. 주민의 의료이용양상 및 의료기관에 대한 인식도 (The Survey on the Health Status of an Islands-District Residents II. The Medical Utilization Pattern and Recognition of Medical Facilities)

  • 고기호;문강;손석준;최진수
    • 농촌의학ㆍ지역보건
    • /
    • 제17권2호
    • /
    • pp.113-121
    • /
    • 1992
  • In order to estimate the pattern of medical care utilization and recognition for health factor among the inhabitants in Wan-do district which is located off the southern seashore from mainland Korea, household interview survey was performed from January 15 to 30, 1990 in Wan-do Gun area. The results observed were following: 1. Among the users of medical facilities 40.8% used public health facility as first contact facility. Lower the income level was and longer the residency duration was, the utilization rate of public health facilities was higher. By age groups and medical security status the utilization pattern was likely to disperse to local clinic and secondary contact medical resources. 2. Medical expense and access time were significantly different between primary contact and secondary contact medical resources. 3. Public health facility was recognized as the favoured institute having advantage of geographic and economic accessibility. 4. Statistically significant determinants in public health facility utilization among total medical service were the region, the medical expense, and the access time.

  • PDF

미혼취업자의 여가시간 및 영향요인 연구 (Leisure Time of Unmarried Workers and Influencing Factors)

  • 안수미;이기영
    • 가족자원경영과 정책
    • /
    • 제16권3호
    • /
    • pp.109-132
    • /
    • 2012
  • This study explores how unmarried workers use their leisure time according to the 2009 Korean Time Use Survey. The purposes of this study are: 1) to investigate leisure time as it relates to leisure participation rates and leisure participation time and 2) to analyze the effect of socio-demographic variables on leisure time and leisure participation by unmarried workers. The following is a summary of the major findings. First, leisure participation differed with variations in leisure activities. Unmarried workers participated in media contact, human relations activities, and hobby activities more than other activities. Participation in learning activities was higher on weekdays than on Sunday. Men participated in sports and outdoor activities more than women on Sundays. The participation rate of media contact was the highest, while the participation rate of volunteer activities was the lowest. Second, influencing factors on leisure time included gender, age, monthly income, and gender role attitudes when work time was controlled. For example, unmarried workers with egalitarian attitudes spent less leisure time. Third, gender was the strongest determinant of leisure participation. The probability of women's leisure participation was higher than men except in regards to sports and outdoor activities, and hobby activities.

  • PDF

고전압 임펄스 기술을 활용한 경도 제거에서 경수의 초기부피와 인가시간이 칼슘이온 농도에 미치는 영향 (Effect of Initial Volume of Hard Water and Contact Time on the Reduction of Calcium Ion Concentration using High Voltage Impulse Technique)

  • 조승연;김태희;장인성;홍웅기;이준호
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1066-1071
    • /
    • 2017
  • Recently high voltage impulse (HVI) technique has been extensively studied for desalting processes to control the $CaCO_3$ scale formation in industrial water practices such as power plant, boiler, and heat exchange operations. Investigation of the operational parameters for the HVI is important, however, those had not been reported yet. In this study, the effect of initial feed volume and contact time on reduction of calcium ion concentration by the HVI technique was investigated. Initial feed volumes of artificial hard water which contained 100 mg/L of $Ca^{2+}$, were set to 1, 2, and 3 L respectively. After 24hr of HVI contact with 12kV, $Ca^{2+}$ ion was reduced to 50, 29 and 19 % of their initial concentration, indicating that calcium removal increased as initial feed volume decreased. This implies the applied HVI pulse energy per unit mass of calcium is important parameter determining overall desalting efficiency. A series of extended operations of HVI up to 30 days verified the long term stability of the HVI system. The calcium ion declined to 40 mg/L after 2~3 days, and further reduction of calcium was not achieved, indicating that optimum operation time could be 2~3 days under these experimental conditions. Consequently, it was confirmed that the important operational parameter of HVI technique is initial feed volume and contact time as well as the applied voltage that was already proven in the previous study.

광학적 비접촉 측정에 의한 구조물 해석의 화상처리 계측 시스템 개발에 관한 연구 (A Study on the Development of Image Processing Measurement System on the Structural Analysis by Optical Non-contact Measurement)

  • 김경석
    • 한국생산제조학회지
    • /
    • 제8권6호
    • /
    • pp.78-83
    • /
    • 1999
  • This study discusses a non-contact optical technique, electronic speckle pattern interformetry(ESPI), that is well suited for in-plane and out-of-plane deformation measurement. However, the existing ESPI methods that are based on dual-exposure, real-time and time-average method have difficulties for accurate measurement of structure, due to irregular intensity and shake of phase. Therefore, phase shifting method has been proposed in order to solve this problem. About the method, the path of reference light in interferometry is shifted and added to least square fitting method to make the improvement in distinction and precision. This proposed method is applied to measure in -plane displacement that is compared with the previous method. Also, Used as specimen AS4/PE따 [30/=30/90]s was analyzed by ESPI based on real-time to determine the characteristics of vibration under no-load and tension. These results are quantitatively compared with those of FEM analysis inmode shapes.

  • PDF

아르곤 저온 플라즈마 처리에 의한 CTA 필름의 접착성 연구 (A Study on Adhesive Properties of Cellulose Triacetate Film by Argon Low Temperature Plasma Treatment)

  • 구강;박영미
    • 한국염색가공학회지
    • /
    • 제16권5호
    • /
    • pp.28-34
    • /
    • 2004
  • The polarizing film application exploits the unique physicochemical properties between PVA(Poly vinyl alcohol) film and CTA(Cellulose triacetate) film. However, hardly any research was aimed at improving the adhesion characteristics of the CTA film by radio frequency(RF) plasma treatment at argon(Ar) gaseous state. In this report, we deal with surface treatment technology for protective CTA film developed specifically for high adhesion applications. After Ar plasma, surface of the films is analyzed by atomic force microscopy(AFM), roughness parameter and peel strength. Furthermore, the wetting properties of the CTA film were studied by contact angle analysis. Results obtained for CTA films treated with a glow discharge showed that this technique is sensitive to newly created physical functions. The roughness and peel strength value increased with an increase in treatment time for initial treatment, but showed decreasing trend for continuous treatment time. The result of contact angle measurement refer that the hydrophilicity of surface was increased. AFM studies indicated that no considerable change of surface morphology occurred up to 3 minutes of treatment time, but a considerable uneven of surface structure resulted from treating time after 5 minutes.

Surface modification of $TiO_2$ by atmospheric pressure plasma

  • 조상진;정충경;부진효
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.96-96
    • /
    • 2010
  • To improve surface wettability, each sample was treated by atmospheric pressure plasma (APP) using dielectric barrier discharge (DBD) system. Argon and oxygen gases were used for treatment gas to modify the $TiO_2$ surface by APP with RF power range from 50 to 200 W. Water contact angle was decreased from $20^{\circ}$ to $10^{\circ}$ with argon only. However, water contact angle was decreased from $20^{\circ}$ to < $1^{\circ}$ with mixture of argon and oxygen. Water contact angle with $O_2$ plasma was lower than water contact angle with Ar plasma at the same RF power. It seems to be increasing the polar force of $TiO_2$ surface. Also, analysis result of X-ray photoelectron spectra (XPS) shows the increase of intensity of O1s shoulder peak, resulting in increasing of surface wettability by APP. Moreover, each water contact angle increased according to increase past time. However, contact angle increase with plasma treatment was lower than without plasma treatment. Additionally, the efficiency of $TiO_2$ photocatalyst was improved by plasma surface-treatment through the degradation experiment of phenol

  • PDF

전원코드의 접촉 불량에 의해 형성된 파형 및 플러그의 특성 (The Properties of Waveform and Plug Formed by Poor Contact of Power Cord Sets)

  • 최충석;김향곤;김동욱;김영석
    • 한국안전학회지
    • /
    • 제20권1호
    • /
    • pp.87-93
    • /
    • 2005
  • In this paper, we analyzed ignition characteristics of combustible material and the waveform of power dissipation, voltage and current by poor contact. And the surface structure of plug by poor contact was analyzed. In the results of experiment, the heat generated by poor contact and ignited the combustible material on power cord sets. The insulation material was molten and carbonized by the heat conduction though plug pit and voids were formed inside of insulation material. The waveform of voltage and power dissipation distorted because of a growth of oxidation by poor contact. In particular, in case that load was big load, the waveform of voltage and power dissipation severely distorted as with the passage of time. The surface of plug pin was changed from erosion mark to welding mark according to big load. The results will be applied to the cause analysis of electrical disaster.

Contact forces generated by fallen debris

  • Sun, Jing;Lam, Nelson;Zhang, Lihai;Gad, Emad;Ruan, Dong
    • Structural Engineering and Mechanics
    • /
    • 제50권5호
    • /
    • pp.589-603
    • /
    • 2014
  • Expressions for determining the value of the impact force as reported in the literature and incorporated into code provisions are essentially quasi-static forces for emulating deflection. Quasi-static forces are not to be confused with contact force which is generated in the vicinity of the point of contact between the impactor and target, and contact force is responsible for damage featuring perforation and denting. The distinction between the two types of forces in the context of impact actions is not widely understood and few guidelines have been developed for their estimation. The value of the contact force can be many times higher than that of the quasi-static force and lasts for a matter of a few milli-seconds whereas the deflection of the target can evolve over a much longer time span. The stiffer the impactor the shorter the period of time to deliver the impulsive action onto the target and consequently the higher the peak value of the contact force. This phenomenon is not taken into account by any contemporary codified method of modelling impact actions which are mostly based on the considerations of momentum and energy principles. Computer software such as LS-DYNA has the capability of predicting contact force but the dynamic stiffness parameters of the impactor material which is required for input into the program has not been documented for debris materials. The alternative, direct, approach for an accurate evaluation of the damage potential of an impact scenario is by physical experimentation. However, it can be difficult to extrapolate observations from laboratory testings to behaviour in real scenarios when the underlying principles have not been established. Contact force is also difficult to measure. Thus, the amount of useful information that can be retrieved from isolated impact experiments to guide design and to quantify risk is very limited. In this paper, practical methods for estimating the amount of contact force that can be generated by the impact of a fallen debris object are introduced along with the governing principles. An experimental-calibration procedure forming part of the assessment procedure has also been verified.