• Title/Summary/Keyword: time-switching

Search Result 1,904, Processing Time 0.033 seconds

A Study on the Reliability Prediction and Lifetime of the Electrolytic Condenser for EMU Inverter (전동차 인버터 구동용 전해콘덴서의 신뢰도예측과 수명 연구)

  • Han, Jae-Hyun;Bae, Chang-Han;Koo, Jeong-Seo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Inverter module, which feeds the converted power to the traction motor for EMU. Consists of the power semiconductors with their gate drive unit(GDU)s and the control computer for driving, voltage, current and speed controls. Electrolytic condenser, connected to the gate drive unit and a core component to drive the power semiconductor, has problems such as reduction in lifetime and malfunction caused by electrical and mechanical characteristic changes from heat generation during high speed switching for generation of stable power. In this study, To check the service life of electrolytic condenser, the test was carried out in two ways. First, In the case of accelerated life testing of condenser, the Arrhenius model is a way of life testing. Another way is to analyze the reliability of the failure data by the method of parametric data analysis. Eventually, life time by accelerated life test than a method of failure data analysis(Weibull distribution) was found to be slightly larger output.

Inrush Current Suppression Method of the Reactive Power Compensator by using a Linear Region of the Switch (스위치의 선형영역을 이용한 무효전력보상기의 돌입전류 억제 방안)

  • Park, Seong-Mi;Kang, Seong-Hyun;Park, Sung-Jun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.55-64
    • /
    • 2013
  • In this paper, a new topology which can add a small reactor in series to a condenser-bank type reactive power compensator to limit current is proposed. And also the proposed topology can add or remove a power condenser safely without any addition of inrush-current suppression resistance. The proposed method tests variable resistance of the drain source of a switching device which is controlled by gate voltage in a two-way switch with a diode rectifier and FET switch. In other words, the proposed method is a inrush-current suppression method with the structure of variable resistance. In particular, the proposed method creates smooth current without any resonance in inrush-current as well as is not limited by the time of switch on and off.

A Hybrid Static Compensator for Dynamic Reactive Power Compensation and Harmonic Suppression

  • Yang, Jia-qiang;Yang, Lei;Su, Zi-peng
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.798-810
    • /
    • 2017
  • This paper presents a combined system of a small-capacity inverter and multigroup delta-connected thyristor switched capacitors (TSCs). The system is referred to as a hybrid static compensator (HSC) and has the functions of dynamic reactive power compensation and harmonic suppression. In the proposed topology, the load reactive power is mainly compensated by the TSCs. Meanwhile the inverter is meant to cooperate with TSCs to achieve continuous reactive power compensation, and to filter the harmonics generated by nonlinear loads and the TSCs. First, the structure and mathematical model of the HSC are discussed Then the control method of the HSC is presented. An improved reduced order generalized integrator (ROGI)-based selective current control method is adopted in the inverter to achieve high-performance reactive and harmonic current compensation. Meanwhile, a switch control strategy is proposed to implement precise and fast switching of the TSCs and to avoid changing the time delay needed by the conventional switch strategy. Experiments are implemented on a 20 KVA HSC prototype and the obtained results verify the validity of the proposed HSC system.

Strategy for the Seamless Mode Transfer of an Inverter in a Master-Slave Control Independent Microgrid

  • Wang, Yi;Jiang, Hanhong;Xing, Pengxiang
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.251-265
    • /
    • 2018
  • To enable a master-slave control independent microgrid system (MSCIMGS) to supply electricity continuously, the microgrid inverter should perform mode transfer between grid-connected and islanding operations. Transient oscillations should be reduced during transfer to effectively conduct a seamless mode transfer. This study uses a typical MSCIMGS as an example and improves the mode transfer strategy in three aspects: (1) adopts a status-tracking algorithm to improve the switching strategy of the outer loop, (2) uses the voltage magnitude and phase pre-synchronization algorithm to reduce transient shock at the time of grid connection, and (3) applies the hybrid-sensitivity $H_{\infty}$ robust controller instead of the current inner loop to improve the robustness of the controller. Simulations and experiments show that the proposed strategy is more practical than the traditional proportional-derivative control mode transfer and effective in reducing voltage and current oscillations during the transfer period.

Implementation of real-time free-space optical interconnection using spatial light modulator (공간광변조기를 이용한 실시간 자유공간 광연결 구현)

  • Lee, Deug-Ju;Kang, Bong-Gyun;Kim, Nam;Suh, Ho-Hyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.956-966
    • /
    • 1997
  • Dynamic free-space optical interconnection system is experimented by a holographic crossbar with single-state switching architecture. For dynamic operation, electrically addressed liquid-crystal spatial light modulator and diffraction gratings are used in place of passive holograms of matrix-matrix crossbar. Diffraction gratings are consisted of regular cells which have different phase delays. This pixelated phase grating array displayed on SLM(Spatial Light modulator) deflects an input beam toward a wanted direction or splits an input beam into many beams and then steers them to desired positions. Through the experimental results, free-space optical interconnection is dynamically perfomed using a computer, SLM and phase diffraction gratings.

  • PDF

A Control Algorithm of Single Phase Active Power Filter based on Rotating Reference Frame (회전좌표계를 이용한 단상능동전력필터의 제어이론)

  • Kim, Jin-Sun;Kim, Young-Seok;Shin, Jae-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1480-1482
    • /
    • 2005
  • The major causes of power quality deterioration are harmonic current through semiconductor switching device, due to use of nonlinear loads such as diodes rectifier or thyristor rectifiers. In response to this concerns, this paper presents a new control method of single-phase active power filter(APF) for the compensation of harmonic current components in nonlinear loads. In order to make the complex calculation to be possible, the single-phase system that has two phases was made by constructing a imaginary second-phase giving time delay to load currents. In the conventional method, a imaginary-phase lagged to the load current T/4(here T is the fundamental cycle) was made. But in this proposed method, the new signal, which has the delayed phase through the filter, using the phase-delay property of low-pass filter, was used as the second phase. As this control method is applied to the system of single phase, an instantaneous calculation was done rather by using the rotating reference frames that synchronizes with source-frequency than by applying instantaneous reactive power theory that uses the conventional fixed reference frames.

  • PDF

Impact and Fatigue Analysis of Superposed Leaf Spring in Electric Power Switch (전력 개폐기의 중첩 판 스프링의 충격 피로 해석)

  • Park W.J.;Ahn K.Y.;Jeong K.Y.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.794-797
    • /
    • 2005
  • The automatic load transfer switch (ALTS), a kind of electric power switch, typically automatically transfers electrical loads from a normal electrical power source to an emergency electrical power source upon reduction or loss of normal power source voltage. It can also automatically re-transfer the load to the normal power source when the normal voltage has been restored within acceptable limits. The transfer operation of ALTS is accomplished by a spring-driven linkage mechanism. In order to control or delay the transfer switching time, the ALTS studied in this paper uses the superposed leaf springs, which are subjected to impact leadings in contacting with electrical contacts. Therefore, to confirm whether the springs has enough mechanical endurance in ALTS, we build a finite element model of the superposed lear springs using LS-DYNA and perform the impact and fatigue analysis.

  • PDF

Improved Trigger System for the Suppression of Harmonics and EMI Derived from the Reverse-Recovery Characteristics of a Thyristor

  • Wei, Tianliu;Wang, Qiuyuan;Mao, Chengxiong;Lu, Jiming;Wang, Dan
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1683-1693
    • /
    • 2017
  • This paper analyses the harmonic pollution to power grids caused by thyristor-controlled devices. It also formulates a mathematic derivation for the voltage spikes in thyristor-controlled branches to explain the harmonic and EMI derived from the reverse-recovery characteristics of the thyristor. With an equivalent nonlinear time-varying voltage source, a detailed simulation model is established, and the periodic dynamic switching characteristic of the thyristor can be explicitly implied. The simulation results are consistent with the probed results from on-site measurements. An improved trigger system with gate-shorted circuit structure is proposed to reduce the voltage spikes that cause EMI. The experimental results indicate that a prototype with the improved trigger system can effectively suppress the voltage spikes.

Harmonic Current Compensation Using Active Power Filter Based on Model Predictive Control Technology

  • Adam, Misbawu;Chen, Yuepeng;Deng, Xiangtian
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1889-1900
    • /
    • 2018
  • Harmonic current mitigation is vital in power distribution networks owing to the inflow of nonlinear loads, distributed generation, and renewable energy sources. The active power filter (APF) is the current electrical equipment that can dynamically compensate for harmonic distortion and eliminate asymmetrical loads. The compensation performance of an APF largely depends on the control strategy applied to the voltage source inverter (VSI). Model predictive control (MPC) has been demonstrated to be one of the effective control approaches to providing fast dynamic responses. This approach covers different types of power converters due to its several advantages, such as flexible control scheme and simple inclusion of nonlinearities and constraints within the controller design. In this study, a finite control set-MPC technique is proposed for the control of VSIs. Unlike conventional control methods, the proposed technique uses a discrete time model of the shunt APF to predict the future behavior of harmonic currents and determine the cost function so as to optimize current errors through the selection of appropriate switching states. The viability of this strategy in terms of harmonic mitigation is verified in MATLAB/Simulink. Experimental results show that MPC performs well in terms of reduced total harmonic distortion and is effective in APFs.

Epithelial to Mesenchymal Transition in CAPD Patients (복막의 섬유화 기전으로서의 상피중간엽전이)

  • Do, Jun-Young
    • Journal of Yeungnam Medical Science
    • /
    • v.23 no.1
    • /
    • pp.10-18
    • /
    • 2006
  • Epithelial to mesenchymal transition (EMT) is an important etiologic factor for the development of peritoneal fibrosis in CAPD patients. Mesothelial cells are main source of trans-differentiated fibroblasts under stress from the bioincompatible peritoneal dialysate. In our study there was no difference in dialysate TGF-${\beta}$ and VEGF between the low and high GDP groups during an initial 12 months. However, after adjusting with D-CA125, the low GDPs group showed a significantly lower D-TGF-${\beta}$/D-CA125 and D-VEGF/CA125 during the initial 12 months. Among the adjusted peritoneal growth factors for CA125, VEGF/CA125 and TGF-b/CA125 were factors significantly associated with greater EMT in this study. Adjustment of the peritoneal growth factor for effluent CA125 (surrogate for mass of HPMCs) revealed significant association with EMT suggesting that the fibroblastoid transition from HPMCs could be affected by the amount of intraperitoneal growth factors (TGF-b, VEGF) per unit mass of HPMCs. There was significant improvement in both cell score and D-CA125 at the sixth and 12th months after switching from a high GDPs solution to a low GDPs solution. Use of icodextrin solution in patients who had average peritoneal transport showed not only better systemic effects such as decreased glucose absorption via dialysate but also preservation of the peritoneum, including less EMT and high mesothelial bulk mass. In conclusion, Therapy with low GDP solution including icodextrin may positively impact preservation of the peritoneal membrane integrity and prevention of peritoneal fibrosis with time on PD.

  • PDF