• Title/Summary/Keyword: time-interval signal

Search Result 302, Processing Time 0.031 seconds

Calculation of Sediment Volume of the Agriculture Reservoir Using DGPS Echo-Sounder (DGPS 음향 측심기를 이용한 농업용 저수지의 퇴적량 산정)

  • Park Seung-Ki;Jeong Jae- Hoon
    • Spatial Information Research
    • /
    • v.13 no.3 s.34
    • /
    • pp.297-307
    • /
    • 2005
  • This study was performed to get the basic data for the dredging project and logical maintenance of the Yaedang reservoir. The survey of reservoir capacity for calculation of sediment volume carried out using DGPS Echo-Sounder during November $25\~30$ in 2004. The latitude and longitude signal from GPS satellite was received a second interval with the UTM coordinate system. Water depth was measured 0.2 second interval by Echo-sounder sensor in MIDAS Surveyor. The UTM coordinate datum were transformed into standard coordinate datum of Korean(TM coordinate datum) using Arc Info System. Mapping of contour was used Sufer, Arc View and Auto CAB Program Storage capacity of Yaedang reservoir was estimated by average contour area method. Result of this time investigation for useful storage determination of Yaedang reservoir was showed 4,601.585 ha-m and was differenced less 5.425ha-m the bygones useful storage.

  • PDF

A Study on Driver Behavior and Dilemma Zone during Yellow Interval at Signalized Intersections (신호교차로 황색현시에서의 운전자 형태 및 딜레마 구간 연구방안)

  • 이승환;이성호;박주남
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.4
    • /
    • pp.7-16
    • /
    • 2003
  • Objective of this research is to analyze drivers' behaviors at signalized intersection during yellow interval. For this, deceleration rate of stopping, PRT(Perception-Response Time), and the relationship between dilemma zone and deceleration rate of stopping were surveyed at two signalized intersections located at urban area(Songtan and Suwon) and local area(Yongin) As a result, the deceleration rate of stopping at signalized intersections and a range of dilemma zone were estimated. It was found that the deceleration rate of stopping and PRT were 1.6m/sec$^2$ and 1.27sec, respectively. These values are bigger than ITE's values which have been used in our country. Accordingly, it is considered that these values should be used as a new design criteria for the traffic signal control.

The Signaling Effect of Stock Repurchase on Equity Offerings in Korea (자기주식매입의 유상증자에 대한 신호효과)

  • Park, Young-Kyu
    • The Korean Journal of Financial Management
    • /
    • v.25 no.1
    • /
    • pp.51-84
    • /
    • 2008
  • We investigate the signaling effect of repurchase preceding new equity issue using Korean data. In a short time span, firms announce stock repurchases and equity offerings. The proximity of two events in Korean firms indicates that those are not independent of each other. In this paper, we test the signaling effect of repurchase on equity offerings on the two measures. One is announcement effect, which is measured as CAR(0, +2). The other is the effectiveness which is measured as CAR(0, +30) because the price movement during this window influences on the price of new issues. Previous studies that stock repurchase convey positive signal to equity offerings-Billet and Xue(2004) and Jung(2004)-construct sample without the limit of time interval between two events. This causes the unclear relation between those because of the long time interval. In this study we consider only samples of being within one year each other to reduce this problem and clarify the signal of repurchase on equity offerings. Korean firms are allowed to repurchase own shares with two different method. One is direct repurchase as same as open market repurchase. The other is stock stabilization fund and stock trust fund which trust company or bank buy and sell their shares on the behalf of firms. Generally, the striking different characteristic between direct repurchase and indirect repurchase is following. Direct repurchase is applied by more strict regulation than indirect repurchase. Therefore, the direct repurchase is more informative signal to the equity offering than the indirect repurchase. We construct two sample firms- firms with direct repurchase preceding-equity offerings and indirect repurchase-preceding equity offering, and one control firms-equity offerings only firms-to investigate the announcement effect and the effectiveness of repurchases. Our findings are as follows. Direct repurchase favorably affect the price of new issues favorably. CAR(0, +2) of firms with direct repurchase is not different from that of equity offerings only firms but CAR(0, +30) is higher than that of equity offerings only firms. For firms with indirect repurchase and equity offerings, Both the announcement effect and the effectiveness does not exist. Jung(2004) suggest the possibilities of how indirect stock repurchase can be regarded as one of unfair trading practices on based on the survey results that financial managers of some of KSE listed firms have been asked of their opinion on the likelihood of the stock repurchase being used in unfair trading. This is not objective empirical evidence but opinion of financial managers. To investigate whether firms announce false signal before equity offerings to boost the price of new issues, we calculate the long-run performance following equity offerings. If firms have announced repurchase to boost the price of new issues intentionally, they would undergo the severe underperformance. The empirical results do not show the severer underperformance of both sample firms than equity offerings only firms. The suggestion of false signaling of repurchase preceding equity offerings is not supported by our evidence.

  • PDF

An Efficient Management and Sliding Window Query for Real-Time Stream Data to Require frequent Update (빈번한 변경을 요구하는 실시간 스트림 데이터의 효율적 관리 및 슬라이딩 윈도우 질의)

  • Kim, Jin-Deog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.12 no.3
    • /
    • pp.509-516
    • /
    • 2008
  • Recently, the operator modules to control external devices are concerned about automatic management system to process continuously changed signals. These signals are the stream data of which characteristics are several numbers. a short report interval and asynchronous report time. It is necessary that the system brings about high accuracy and real time process for stream data. The typical queries of these systems consist of the current query to search the latest signal value, the snapshot query at a past time, the sliding window query from a past time to current. In this paper, we propose the efficient method to manage the above signals by using a file structured database in small-size operating systems. We also propose a query model to accommodate various queries including the sliding window query. The file database in the QNX adopts a delta version and a shared memory buffering method for the resource limit of a small storage and a low computing power.

Chronic persistent post-surgical pain following staging laparotomy for carcinoma of ovary and its relationship to signal transduction genes

  • Saxena, Ashok Kumar;Chilkoti, Geetanjali T;Chopra, Anand K;Banerjee, Basu Dev;Sharma, Tusha
    • The Korean Journal of Pain
    • /
    • v.29 no.4
    • /
    • pp.239-248
    • /
    • 2016
  • Background: The present study was undertaken to evaluate the incidence of chronic persistent post-surgical pain (CPPP) and the role of signal transduction genes in patients undergoing staging laparotomy for carcinoma ovary. Methods: The present observational study was undertaken following institutional ethical committee approval and informed consent from all the participants. A total 21 patients of ASA grade I to III with age 20-70 years, scheduled for elective staging laparotomy for carcinoma ovary were included. Patients were excluded if had other causes of pain, cognitive dysfunction or chronic neurological disorders. Statistical analysis of pool data was done using SPSS version-17. For various scales like GPE, PDQ, NPSI, the visual analogue scale (VAS), global perceived effect (GPE), the pain DETECT questionnaire (PDQ), and neuropathic pain symptoms inventory (NPSI), one factor repaeted measure ANOVA applied with simple contrast with baseline as on post-operative day 1 (considered as reference and compared with subsequent time-interval), and the P values were adjusted according to "Bonferroni adjustments". In patients with CPPP, the ${\Delta}ct$ values of mRNA expressions of genes at the end of postoperative day 90 were compared with the baseline control values by one factor repeated ANOVA. P value < 0.005 significant. Results: The present study demonstrates 38.1% (8 out of 21 patients) incidence of CPPP. The functional status and quality of life as were observed to be significantly diminished in all patients with chronic pain. An up-regulation in the mRNA expression of signal transduction and a positive correlation was noted between the mRNA expression of signal transduction genes and VAS score in all patients with CPPP at the end of postoperative day 90. Conclusions: The reported incidence of CPPP in patients with carcinoma ovary was 38.1%. An up-regulation and positive correlation between mRNA expression of signal transduction genes and VAS score depicts its potential role in the pathogenesis of CPPP.

Design and Fabrication of Clock Recovery Module for Gap Filter of Satellite DMB (위성 DMB 중계기용 클럭 재생 모듈 설계 및 제작)

  • Hong, Soon-Young;Shin, Yeoung-Seop;Hong, Sung-Yong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.4 s.119
    • /
    • pp.423-429
    • /
    • 2007
  • The clock recovery module of gap filler for satellite DMB is proposed. Proposed module sustains the output frequency of 10 MHz whether the received signal from the satellite is unstable or cut off within 0.5 sec. The advantages of this module is without frequency tuning at regular interval and low material cost. This module is fabricated by using CPLD as clock recovery IC and new type of loop filter for satisfying the fast lock time and long hold over time simultaneously. The measured performance of the fabricated module has a holdover time of 11 sec at frequency stability less than 0.01 ppm, and phase noise of -113 dBc/Hz at 100 Hz offset.

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.

Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors (PPG 및 ECG 센서를 이용한 혈압추정 기법 개발)

  • Park, Hyun-Moon;Lee, Jung-Chul;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.6
    • /
    • pp.1257-1264
    • /
    • 2019
  • The traditional cuff-based method for BP(Blood Pressure) measurement is not suitable for continuous real-time BP measurement techniques. For this reason, the previous studies estimated various blood pressures by fusion with the electrocardiography (ECG) and photoplethysmogram (PPG) sensor signals. However, conventional techniques based on PPG bio-sensing measurement face many challenging issues such as noisy supply fluctuation, small pulsation, and drifting non-pulsatile. This paper proposed a novel BP estimation methods using PPG and ECG sensors, which can be derived from the relationship between PPG and ECG using PTT(Pulse Transit Time) and PWV(Pulse Wave Velocity). Unlike conventional height ratio features, which are extracted on the basis of the peaks in the PPG and ECG waveform. The proposed method can be reliably obtained even if there are missing peaks among the sensed PPG signal. The increased reliability comes from periodical estimation of the peak-to-peak interval time using ECG and PPG. After 250,000 times trials of the blood pressure measurement, the proposed estimation technique was verified with the accuracy of ±28.5% error, compared to a commercialized BP device.

An analysis of correlation between EEG signal and HRV during attentional status with children under 15 years (15세 미만 아동을 대상으로 한 집중상태에서 EEG 신호와 HRV의 상관관계 분석)

  • Choi, Woo-Jin;Lee, Chug-Ki;Yoo, Sun-Kook
    • Science of Emotion and Sensibility
    • /
    • v.14 no.2
    • /
    • pp.269-278
    • /
    • 2011
  • This paper illustrates the inter-relationship between the theta/alpha ratio of the EEG signal and multiple HRV related parameters associated with the cardiovascular system response during event-related stimuli. Both EEG and PPG signals were simultaneously recorded in 21 healthy subjects. All subjects had their attention focused on the CNT program for nine minutes. Time-frequency analysis was applied to the EEG and PPG signals. The theta/alpha ratio was extracted from the EEG results, and the HRV features, including beat interval(1), SDNN(2), RMSSD(3), NN50(4), LF(5), HF(6), and LFIHF(7), were extracted from the PPG. Through multiple linear regression, the relationship ($R^2$) between the multiple combined features and the theta/alpha rhythm was identified. As a result, the combinations of $R^2$($R^2=0.253$; seven dimensions) and the theta/alpha ratio indicated a higher inter-relationship value than those of other combinations. The combinations of features that were greater than three dimensions, based on {SDNN(2), HF(6)}, generally showed higher $R^2$ value. We demonstrate that the high dimensional combinations had a higher correlation than did the low dimensional combinations.

  • PDF

Arrhythmia Classification based on Binary Coding using QRS Feature Variability (QRS 특징점 변화에 따른 바이너리 코딩 기반의 부정맥 분류)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1947-1954
    • /
    • 2013
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require accurate detection of P-QRS-T point, higher computational cost and larger processing time. But it is difficult to detect the P and T wave signal because of person's individual difference. Therefore it is necessary to design efficient algorithm that classifies different arrhythmia in realtime and decreases computational cost by extrating minimal feature. In this paper, we propose arrhythmia detection based on binary coding using QRS feature varibility. For this purpose, we detected R wave, RR interval, QRS width from noise-free ECG signal through the preprocessing method. Also, we classified arrhythmia in realtime by converting threshold variability of feature to binary code. PVC, PAC, Normal, BBB, Paced beat classification is evaluated by using 39 record of MIT-BIH arrhythmia database. The achieved scores indicate the average of 97.18%, 94.14%, 99.83%, 92.77%, 97.48% in PVC, PAC, Normal, BBB, Paced beat classification.