• Title/Summary/Keyword: time-interval signal

Search Result 302, Processing Time 0.027 seconds

Characteristics of Impulse Radios for Mu1tipath Channels (다중 경로 채널에서 임펄스 라디오의 특징)

  • 이호준;한병칠
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.26 no.11B
    • /
    • pp.1501-1509
    • /
    • 2001
  • Recently, the use of wireless communication systems has been rapidly increasing, which results in a difficult problem in efficient control of limited frequency resources. As a way of solving this problem, the ultra wideband time hopping impulse radio system attracts much attention. The impulse radio system communicates pulse position modulated data using Gaussian monocycle pulses of very short duration less than 1 nsec. Thus the transmitted signal has very low power spectral density and ultra wide bandwidth from near D.C. to a few GHz. It is blown that it hardly interferes with the existing communication systems because of its very low power spectral density. The purpose of this paper is to characterize multipath propagation of the impulse radio signal and to evaluate the performance of the correlator-based receiver for the multipath environments. In this paper, we consider the deterministic two-path model and the statistical indoor multipath model of Saleh and Valenzuela. For the two-path model the output of the correlator with the ideal reference waveform varies according to the relative difference between the indirect path delay and the time interval of PPM, and to the indirect path gains. In addition, the characteristics of bit error rates is measured for the two models through computer simulation. The simulation results indicate that the performance of the impulse radio system depends both on the relative difference between the indirect path delay and the time interval of PPM, and on the indirect path gains. Furthermore, it is observed that the reference signal designed for the AWGN channel can not be applied to the multipath channels.

  • PDF

Premature Ventricular Contraction Classification through R Peak Pattern and RR Interval based on Optimal R Wave Detection (최적 R파 검출 기반의 R피크 패턴과 RR간격을 통한 조기심실수축 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.233-242
    • /
    • 2018
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require higher computational cost and larger processing time. Therefore it is necessary to design efficient algorithm that classifies PVC(premature ventricular contraction) and decreases computational cost by accurately detecting feature point based on only R peak through optimal R wave. For this purpose, we detected R wave through optimal threshold value and extracted RR interval and R peak pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through RR interval and R peak pattern. The performance of R wave detection and PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30. The achieved scores indicate the average of 99.02% in R wave detection and the rate of 94.85% in PVC classification.

Development of Data Acquistion and Processing System for the Analysis of Biophysiological signal (생체신호 처리를 위한 시스템 개발)

  • 이준하;이상학;신현진
    • Progress in Medical Physics
    • /
    • v.3 no.1
    • /
    • pp.71-78
    • /
    • 1992
  • This study describes the design of the biophysiological signal processing analyzer which can collect and analyze the biosignal raw data. System hardware is consisted of the IBM PC AT. pre-amplifier. AID converter, Counter/Timer. and RS-232C processor. Biophysiological signal data were processed by the software digital filter. FFT and graphic processing routine. The tachogram and FFT of the the peak to peak interval time was accomplished by the Graphic user interface software using the biophysiological signal processed data. Using this system. the powerspectrum of the heart rate variability during the long term could be observed. Experimental results of this system approach our purpose. which is improved the cost performance. easy to use. reducing raw-data noise and optimizing model for digital filter.

  • PDF

A Study on the Heart Rate Variability for Improvement of AR / VR Service (AR/VR 서비스 향상을 위한 심박 변이도 연구)

  • Park, Hyun-Moon;Hwang, Tae-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.15 no.1
    • /
    • pp.191-198
    • /
    • 2020
  • In this study, we proposed a real-time ECG analytical method for predicting stress and dangerous heart condition using the ECG signal in playing AR/VR device. A real-time diagnosis is used as R-R interval based HRV(:Heart rate variability), BPM(:Beats Per Minitue) and autonomic nervous research with through mapping method of two-dimensional planes. The ECG data were analyzed every 5 minutes and derived from autonomic nervous system diagnosis.

Multiple-symbol Nonlinear Continuous Phase Frequency Shift Keying (다중 심볼 비선형 연속 위상 주파수 천이 변조)

  • 주판유;송명규;홍성권;강성진;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.10
    • /
    • pp.2660-2669
    • /
    • 1996
  • In this paper, it is called nonlinear-symbol CPFSK(NCPFSK) which is modulated by the nonlinear function of information carrying phase function within all symbol interval produce time invariant trellis structure. In general, the bit error probability performance of CPFSK modultion scheme within given signal constellation is determined from the number of memory elementsof continuous phase encoder, i.e. number of state. In this paper the number of state of analyticall designed NCPFSK is time invariant. And the nonlinear symbol mapping function of the proposed moudlation produces the nonlinear symbol andthe phase state of the modulation for updating the phase function of NCPFSK. It si shown in this paper nonlinear symbol CPFSK with multiple TCM to make further improvements in d$^{2}$, and analyzed BER performance in AWGN channel envioronments.hannel envioronments.

  • PDF

A study on the Modeling of Nonlinear Properties of Biological Signal using Genetic Programming (유전자 프로그래밍을 이용한 생체 신호의 비선형 특성 모델링에 관한 연구)

  • Kim, Bo-Yeon;Park, Kwang-Suk
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.70-73
    • /
    • 1996
  • Many researchers had considered biological systems as linear systems. In many cases of biological systems, the phenomena that show the regular and periodic dynamics are considered the normal state. However, some clinical experiments reported, in some cases, the periodic signals represented the abnormal state. We assume that signals from human body system are generated from deterministic, intrinsic mechanisms and can be represented a simple equation that show nonlinear dynamics dependent on control parameters. The objective of our study is to model a nonlinear dynamics correctly from the nonlinear time series using the genetic programming method; to find a simple equation of nonlinear dynamics using collected time series and its nonlinear characteristics. We applied genetic programming to model RR interval of ECG that shows chaotic phenomena. We used 4 statistic measures and 2 fractal measures to estimate fitness of each chromosome, and could obtain good solutions of which chaotic features are similar.

  • PDF

The Study on Intraoral Pressure, Closure Duration, and VOT During Phonation of Korean Bilabial Stop Consonants (한국어 양순 파열음 발음시 구강내압과 폐쇄기, VOT에 대한 연구)

  • Pyo Hwa Young;Choi Hong Shik
    • Proceedings of the KSPS conference
    • /
    • 1996.10a
    • /
    • pp.390-398
    • /
    • 1996
  • Acoustic analysis study was performed on 20 normal subjects by speaking nonsense syllables composed of Korean bilabial stops(/p, $p^{*}$/, ph/) and their Preceding and/or following vowel /a/(that is, [pa, $p^{*}a$, pha, apa, $ap^{*}a$, apha]) with an ultraminiature pressure sensor in their mouths. Speech materials were phonated twice, once with a moderate voice, another time with a loud voice. The acoustic signal and intraoral pressure were recorded simultaneously on computer. By these procedures, we were to measure the intraoral pressure, closure duration and VOT of Korean bilabial stops, and to compare the values one another according to the intensity of phonation and the position of the target consonants. Intraoral pressure was measured by the peak intraoral pressure value of its wave; closure duration by the time interval between the onset of intraoral pressure build-up and the burst meaning the release of closure; Voice onset time(VOT) by the time interval between the burst and the onset of glottal vibration. Heavily aspirated bilabial stop consonant /ph/ showed the highest intraoral pressure value, unaspirated /p$^{*}$/, the second, slightly aspirated /p/, the lowest. The syllable initial bilabial stops showed higher intraoral pressure than word initial stops, and the value of loudly phonated consonants were higher than moderate consonants. The longest closure duration period was that of /$p^{*}$/ and the shortest, /p/, and the duration was longer in word initial position and in the moderate voice. In VOT, the order of the longest to shortest was /ph/, /p/, /$p^{*}$/, and the value was shorter when the consonant was in intervocalic position and when it was phonated with a loud voice.

  • PDF

The Study on Intraoral Pressure, Closure Duration and VOT During Phonation of Korean Bilabial Stop Consonants (한국어 양순 파열음 발음시 구강내압과 폐쇄기, VOT에 대한 연구)

  • 표화영;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.7 no.1
    • /
    • pp.50-55
    • /
    • 1996
  • Acoustic analysis study was performed on 20 normal subjects by speaking nonsense syllables composed of Korean bilabial stops$(/P, P^{\star}, P^{h}/)$ and their preceding and/or following vowel /a/ (that is, $[pa, p^{\star}a, p^{h}a, apa, ap^{\star}a, ap^{h}a]$) with an ultraminiature pressure, sensor. in their mouths. Speech materials were phonated twice, once with a moderate voice, another time with a loud voice. The acoustic signal and intraoral pressure were recorded simultaneously on computer. By these procedures, we were to measure the intraoral pressure, closure duration and VOT of Korean bilabial stops, and to compare the values one another according to the intensity of phonation and the position of the target consonants. Intraoral pressure was measured by the peak intraoral pressure value of Its wave closure duration by the time interval between the onset of intraoral pressure build-up and the burst meaning the release of closure ; Voice onset time(VOT) on by the time interval between the burst and the onset or glottal vibration. Heavily aspirated bilabial stop consonant /$p^h$/ showed the highest intraoral pressure value, unaspirated /$p^{\star}$/, the second, slightly aspirated /P/, the lowest. The syllable initial bilabial stops showed higher intraoral pressure than word initial stops, and the value of loudly phonated consonants were higher than moderate consonants. The longest closure duration period was that of /$p^{\star}$/ and the shortest, /P/, and the duration was longer in word initial position and in the moderate voice. In VOT, the order of the longest to shortest was $/{p^h}/, /p/, /{p^\star}/$, and the value was shorer when the consonant was in intervocalic position and when it was phonated with a loud voice.

  • PDF

Reconstruction of gusty wind speed time series from autonomous data logger records

  • Amezcua, Javier;Munoz, Raul;Probst, Oliver
    • Wind and Structures
    • /
    • v.14 no.4
    • /
    • pp.337-357
    • /
    • 2011
  • The collection of wind speed time series by means of digital data loggers occurs in many domains, including civil engineering, environmental sciences and wind turbine technology. Since averaging intervals are often significantly larger than typical system time scales, the information lost has to be recovered in order to reconstruct the true dynamics of the system. In the present work we present a simple algorithm capable of generating a real-time wind speed time series from data logger records containing the average, maximum, and minimum values of the wind speed in a fixed interval, as well as the standard deviation. The signal is generated from a generalized random Fourier series. The spectrum can be matched to any desired theoretical or measured frequency distribution. Extreme values are specified through a postprocessing step based on the concept of constrained simulation. Applications of the algorithm to 10-min wind speed records logged at a test site at 60 m height above the ground show that the recorded 10-min values can be reproduced by the simulated time series to a high degree of accuracy.

A Study Absolute Position Estimation of Sound Source (3차원 음향홀로그래픽을 이용한 음원위치 추정에 관한 연구)

  • Kim, Chun-Duk;Sim, Dong-Youn;Jang, Bee;Lee, Chai-Bong;Cha, Kyung-Hwan
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.76-82
    • /
    • 1997
  • The paper describes simulations and experimental results using a measuring system which utilizes the acoustic holographic method in order to exactly estimate an absolute position of a sound source. The measuring surface is installed to satisfy with a far field to the sound source and is composed of linear arrayed seven microphones. A measurement is simultaneously recorded by a reference microphone setting up a neighbour sound source and the linear arrayed seven microphones which are moved to the same interval. An absolute position of sound source is estimated by the cross-spectrum method to the received sounds between a reference and the measuring microphones. Phase differences of each microphone and time delays during scanning are compensated to the reference microphone and the measuring time of the first column. An optimal interval for each microphone in the measuring surface is decided by a numerical simulation. A source signal makes use of a sinusoid, and S/N ratio is 30dB in the experiment. The optimal microphone's interval in the simulation and the experiment is decided in order to satisfy with the Nyquist space sampling condition related to the wave length of 2kHz sinusoid. Mainlobe width of a estimated 3D hologram in the case of 2kHz source signal is decreased to 87% and 30% in comparison to 500Hz and 1kHz, and then a valid of simulation results is confirmed. Therefore, we verified a utilization of the study for a sound source estimation using 3ㅇ acoustic holographic method.

  • PDF