• Title/Summary/Keyword: time to cracking

Search Result 464, Processing Time 0.025 seconds

A numerical-experimental evaluation of beams composed of a steel frame with welded and conventional stirrups

  • Goncalves, Wagner L.;Gomes, Guilherme F.;Mendez, Yohan D.;Almeida, Fabricio A.;Santos, Valquiria C.;Cunha, Sebastiao S.Jr.
    • Computers and Concrete
    • /
    • v.22 no.1
    • /
    • pp.27-37
    • /
    • 2018
  • Reinforced concrete structures are widely used in civil engineering projects around the world in different designs. Due to the great evolution in computational equipment and numerical methods, structural analysis has become more and more reliable, and in turn more closely approximates reality. Thus among the many numerical methods used to carry out these types of analyses, the finite element method has been highlighted as an optimized tool option, combined with the non-linear and linear analysis techniques of structures. In this paper, the behavior of reinforced concrete beams was analyzed in two different configurations: i) with welding and ii) conventionally lashed stirrups using annealed wire. The structures were subjected to normal and tangential forces up to the limit of their bending resistance capacities to observe the cracking process and growth of the concrete structure. This study was undertaken to evaluate the effectiveness of welded wire fabric as shear reinforcement in concrete prismatic beams under static loading conditions. Experimental analysis was carried out in order compare the maximum load of both configurations, the experimental load-time profile applied in the first configuration was used to reproduce the same loading conditions in the numerical simulations. Thus, comparisons between the numerical and experimental results of the welded frame beam show that the proposed model can estimate the concrete strength and failure behavior accurately.

Crack Detection of Concrete Using Fiber Optic Cables (Fiber Optic Cable을 이용한 콘크리트 균열탐사)

  • Cho, Nam-So;Kim, Nam-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.157-163
    • /
    • 2007
  • Crack detection technique for concrete structures has been developed in this study. Experimental tests were carried out to detect a surface and internal crack, employing common fiber optic cables and OTDR(optical time domain reflectometry), an optical signal analyzer which is widely used to detect damages at fiber optic cables in the field of optical engineering. While initial concrete crack is ready to occur under cracking force, the occurrence and location of the crack are simultaneously detected to give the same damage to fiber optic cables which have been attached to and/or embedded into concrete in advance. It is obtained through successive tests that the principal factors for crack detection is the covering state of fiber optic cable, and total 4 tests including a preliminary test were conducted and the crack detection technique was verified. The practical usefulness would be expected at crack management and maintenance of concrete structures.

Link-E-Param : A URL Parameter Encryption Technique for Improving Web Application Security (Link-E-Param : 웹 애플리케이션 보안 강화를 위한 URL 파라미터 암호화 기법)

  • Lim, Deok-Byung;Park, Jun-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.9B
    • /
    • pp.1073-1081
    • /
    • 2011
  • An URL parameter can hold some information that is confidential or vulnerable to illegitimate tampering. We propose Link-E-Param(Link with Encrypted Parameters) to protect the whole URL parameter names as well as their values. Unlike other techniques concealing only some of the URL parameters, it will successfully discourage attacks based on URL analysis to steal secret information on the Web sites. We implement Link-E-Param in the form of a servlet filter to be deployed on any Java Web server by simply copying a jar file and setting a few configuration values. Thus it can be used for any existing Web application without modifying the application. It also supports numerous encryption algorithms to choose from. Experiments show that our implementation induces only 2~3% increase in user response time due to encryption and decryption, which is deemed acceptable.

Influence of corrosive phenomena on bearing capacity of RC and PC beams

  • Malerba, Pier Giorgio;Sgambi, Luca;Ielmini, Diego;Gotti, Giordano
    • Advances in concrete construction
    • /
    • v.5 no.2
    • /
    • pp.117-143
    • /
    • 2017
  • The attack of environmental aggressive agents progressively reduces the structural reliability of buildings and infrastructures and, in the worst exposition conditions, may even lead to their collapse in the long period. A change in the material and sectional characteristics of a structural element, due to the environmental damaging effects, changes its mechanical behaviour and varies both the internal stress redistribution and the kinematics through which it reaches its ultimate state. To identify such a behaviour, the evolution of both the damaging process and its mechanical consequences have to be taken into account. This paper presents a computational approach for the analysis of reinforced and prestressed concrete elements under sustained loading conditions and subjected to given damaging scenarios. The effects of the diffusion of aggressive agents, of the onset and development of the corrosion state in the reinforcement and the corresponding mechanical response are studied. As known, the corrosion on the reinforcing bars influences the damaging rate in the cracking pattern evolution; hence, the damage development and the mechanical behaviours are considered as coupled phenomena. The reliability of such an approach is validated in modelling the diffusion of the aggressive agents and the changes in the mechanical response of simple structural elements whose experimental behaviour is reported in Literature. A second set of analyses studies the effects of the corrosion of the tendons of a P.C. beam and explores potentially unexpected structural responses caused by corrosion under different aggressive exposition. The role of the different types and of the different positions of the damaging agents is discussed. In particular, it is shown how the collapse mode of the beam may switch from flexural to shear type, in case corrosion is caused by a localized chloride attack in the shear span.

Improving Data Availability by Data Partitioning and Partial Overlapping on Multiple Cloud Storages (다수 클라우드 스토리지로의 데이터 분할 및 부분 중복을 통한 데이터 가용성 향상)

  • Park, Jun-Cheol
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.12B
    • /
    • pp.1498-1508
    • /
    • 2011
  • A cloud service customer has no other way but to wait for his lost data to be recovered by the cloud service provider when the data was lost or not accessible for a while due to the provider's system failure, cracking attempt, malfunction, or outage. We consider a solution to address this problem that can be implemented in the cloud client's domain, rather than in the cloud service provider's domain. We propose a high level architecture and scheme for successfully retrieving data units even when several cloud storages are not accessible at the same time. The scheme is based on a clever way of partitioning and partial overlapping of data for being stored on multiple cloud storages. In addition to providing a high level of data availability, the scheme makes it possible to re-encrypt data units with new keys in a user transparent way, and can produce the complete log of every user's data units accessed, for assessing data disclosure, if needed.

Time dependent finite element analysis of steel-concrete composite beams considering partial interaction

  • Dias, Maiga M.;Tamayo, Jorge L.P.;Morsch, Inacio B.;Awruch, Armando M.
    • Computers and Concrete
    • /
    • v.15 no.4
    • /
    • pp.687-707
    • /
    • 2015
  • A finite element computer code for short-term analysis of steel-concrete composite structures is extended to study long-term effects under service loads, in the present work. Long-term effects are important in engineering design because they influence stress and strain distribution of the structural system and therefore contribute to the increment of deflections in these structures. For creep analysis, a rheological model based on a Kelvin chain, with elements placed in series, was employed. The parameters of the Kelvin chain were obtained using Dirichlet series. Creep and shrinkage models, proposed by the CEB FIP 90, were used. The shear-lag phenomenon that takes place at the concrete slab is usually neglected or not properly taken into account in the formulation of beam-column finite elements. Therefore, in this work, a three-dimensional numerical model based on the assemblage of shell finite elements for representing the steel beam and the concrete slab is used. Stud shear connectors are represented for special beam-column elements to simulate the partial interaction at the slab-beam interface. The two-dimensional representation of the concrete slab permits to capture the non-uniform shear stress distribution in the horizontal plane of the slab due to shear-lag phenomenon. The model is validated with experimental results of two full-scale continuous composite beams previously studied by other authors. Results are given in terms of displacements, bending moments and cracking patterns in order to shown the influence of long-term effects in the structural response and also the potentiality of the present numerical code.

Failure Criteria of a 6-Inch Carbon Steel Pipe Elbow According to Deformation Angle Measurement Positions (변형각의 측정 위치에 따른 6인치 탄소강관엘보의 파괴 기준)

  • Yun, Da Woon;Jeon, Bub Gyu;Chang, Sung Jin;Park, Dong Uk;Kim, Sung Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.13-22
    • /
    • 2022
  • This study proposes a low-cycle fatigue life derived from measurement points on pipe elbows, which are components that are vulnerable to seismic load in the interface piping systems of nuclear power plants that use seismic isolation systems. In order to quantitatively define limit states regarding leakage, i.e., actual failure caused by low-cycle fatigue, in-plane cyclic loading tests were performed using a sine wave of constant amplitude. The test specimens consisted of SCH40 6-inch carbon steel pipe elbows and straight pipes, and an image processing method was used to measure the nonlinear behavior of the test specimens. The leakage lines caused by low-cycle fatigue and the low-cycle fatigue curves were compared and analyzed using the relationship between the relative deformation angles, which were measured based on each of the measurement points on the straight pipe, and the moment, which was measured at the center of the pipe elbow. Damage indices based on the combination of ductility and dissipation energy at each measurement point were used to quantitatively express the time at which leakage occurs due to through-wall cracking in the pipe elbow.

A Study on the Static and Dynamic Characteristics of Raised Girder Bridges (양각 거더교의 정적·동적특성에 관한 연구)

  • Ji-Yeon Lee;Sung Kim;Sung-Jin Park
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.851-858
    • /
    • 2023
  • Purpose: A study was conducted to ensure the structural safety of a raised girder bridge with improved cross-sectional efficiency compared to the conventional PSC girder. For this purpose, the cross-sectional specifications such as girder length, height, and width were determined, the arrangement of the tendons was designed, and the practical performance of the raised girder under static and dynamic loads was verified. Method: The static performance experiment examined the serviceability limit state by measuring behavioral responses such as deflection and cracking to primary and secondary static loads. In addition, the dynamic load loading experiment measured the acceleration and displacement behavior response over time to calculate the natural frequency and damping ratio to examine the usability limit state. Result: As a result of the static performance test, the deflection value based on the maximum applied load showed stable behavior, and the crack width measured at the maximum applied load level was very small, satisfying the serviceability limit state. In addition, a natural frequency exceeding the natural frequency calculated during the design of the dynamic loading experiment was found, and a damping ratio that satisfies the current regulations was found to be secured.

A Study on Improvement of Field Implementation of Asphalt Surface Reinforcement Method (아스팔트 표면 강화공법의 현장 적용성 개선 방안 연구)

  • Jo, Shin Haeng;Kim, Kyungnam;Kim, Nakseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.2
    • /
    • pp.389-395
    • /
    • 2017
  • A study was carried out to improve the field implementation of asphalt surface reinforcement method which is a preventive maintenance. Mean Texture Depth (MTD) was measured to quantify the surface condition and used to determine the optimum application rate. Determining the application rate using MTD can reduce the material loss from 30% to 15%. In order to reduce the curing time to 30 minutes, the heat capacity of $317kcal/m^2$ is required. Therefore, the design capacity of the heating curing device requires more than 380,000 kcal/hr. The asphalt surface reinforcement method is preferably applied at a time when slight cracking occurs before the permanent deformation becomes serious. Through the analysis of the pavement survey data, it was decided to apply the surface reinforcement method at the crack rate of 3~4%. Heating the surface reinforcement agent to $50^{\circ}C$ improves workability and ensures sufficient penetration depth even at a crack width of 1 mm. The results will be utilized as basic data for the development of automated construction equipment for efficiency improvement.

Line Laser Image Processing for Automated Crack Detection of Concrete Structures (콘크리트 구조물의 자동화 균열탐지를 위한 라인 레이저 영상분석)

  • Kim, Junhee;Shin, Yoon-Soo;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.31 no.3
    • /
    • pp.147-153
    • /
    • 2018
  • Cracking in concrete structure must be examined according to appropriate methods, to ensure structural serviceability and to prevent structural deterioration, since cracks opened wide for a long time expedite corrosion of rebar. A site investigation is conducted in a regular basis to monitor structural deterioration by tracking growing cracks. However, the visual inspection are labor intensive. and judgment are subject. To overcome the limit of the on-site visual investigation image processing for identifying the cracks of concrete structures by analyzing 2D images has been developed. This study develops a unique 3D technique utilizing a line laser and its projection image onto concrete surfaces. Automated process of crack detection is developed by the algorithms of automatizing crack map generation and image data acquisition. Performance of the developed method is experimentally evaluated.