• Title/Summary/Keyword: time to cracking

Search Result 464, Processing Time 0.031 seconds

Experimental study on hollow steel-reinforced concrete-filled GFRP tubular members under axial compression

  • Chen, B.L.;Wang, L.G.
    • Steel and Composite Structures
    • /
    • v.32 no.1
    • /
    • pp.59-66
    • /
    • 2019
  • Hollow steel-reinforced concrete-filled GFRP tubular member is a new kind of composite members. Firstly set the mold in the GFRP tube (non-bearing component), then set the longitudinal reinforcements with stirrups (steel reinforcement cage) between the GFRP tube and the mold, and filled the concrete between them. Through the axial compression test of the hollow steel-reinforced concrete-filled GFRP tubular member, the working mechanism and failure modes of composite members were obtained. Based on the experiment, when the load reached the ranges of $55-70%P_u$ ($P_u-ultimate$ load), white cracks appeared on the surface of the GFRP tubes of specimens. At that time, the confinement effects of the GFRP tubes on core concrete were obvious. Keep loading, the ranges of white cracks were expanding, and the confinement effects increased proportionally. In addition, the damages of specimens, which were accompanied with great noise, were marked by fiber breaking and resin cracking on the surface of GFRP tubes, also accompanied with concrete crushing. The bearing capacity of the axially compressed components increased with the increase of reinforcement ratio, and decreased with the increase of hollow ratio. When the reinforcement ratio was increased from 0 to 4.30%, the bearing capacity was increased by about 23%. When the diameter of hollow part was decreased from 55mm to 0, the bearing capacity was increased by about 32%.

CUTTING EFFICACY OF Er:YAG LASER AND CONVENTIONAL BUR IN DECIDUOUS AND PERMANENT TEETH (Er:YAG laser와 Conventional bur의 유치와 영구치 치아삭제효과 비교)

  • Park, In-Cheon;Lee, Chang-Seop;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.272-285
    • /
    • 2003
  • This study was conducted to observe the microscopic structures of cavities formed after ablation of primary teeth, permanent teeth, enamel and dentin in using a bur and cavities formed after ablation using laser and the following results were obtained after comparing the effects of ablation. Using a #330 bur and Er:YAG laser irradiated at 150 mJ, 200 mJ, 250 mJ and 300 mJ all at the frequency of 5 Hz, 1 mm enamel and dentin samples were ablated and the ablation time was measured. In order to measure the surfaces ablated, 5 each of primary teeth and permanent teeth were ablated using a #330 bur and Er:YAG laser at 150 mJ, 200 mJ, 250 mJ and 300 mJ for 1 sec and the cross section and vertical section were observed. The following results were obtained : 1. Cutting time of Er:YAG laser was longer than that of conventinal high-speed bur regardless of teeth type. 2. Cutting on enamel, Cutting time of conventional high-speed bur in deciduous teeth was longer than in permanent teeth(P<0.05). But Er:YAG laser was not showed any difference between the deciduous and permanent teeth(P>0.05). 3. Cutting on dentin, Cutting time of conventional high-speed bur in permanent teeth was longer than deciduous teeth. Er:YAG laser of 150 mJ, 5 Hz in permanent teeth was longer than in deciduous teeth(p<0.05). But laser of other power did not showed mean difference. 4. The cavity surface treated with the convetional high-speed bur revealed a relatively flat appearance, almost covered with a debris-like smear layer. Cavity wall showed striped appearance because of blade of bur. 5. The cavity surface treated by the Er:YAG laser system was irregular or rough surface with the absence charring, carbonization, or cracking of the dentin. In addition, there was an absence of a smear layer. Cavity floor was round and relatively smooth. According to these results, cutting time of Er:YAG laser was almostly same in permanent and deciduous teeth, but more effective in dentin than enamel. Cutting the sample, Er:YAG laser was needed more time than conventional bur. But SEM findings suggested that laser device produced favorable surface characteristic(i.e, no smear layer, irregular surface, cracking).

  • PDF

Applicability of High-strength Mass Concrete through Setting Time and Horizontally-divided Placement (응결시간제어용 배합과 수평분할을 고려한 고강도 매스콘크리트의 적용성 평가)

  • Cho, Seung-Ho;Paik, In-Kwan;Lee, Dong-Ha;Roh, Young-Sook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.2
    • /
    • pp.103-113
    • /
    • 2017
  • In the current study, retarding type and standard type admixture design of concrete have been proposed to control the generation of hydration heat for foundation members that use high strengths concrete. Finite element analysis also has been conducted to understand the rational placing heights of concrete. In addition, real-size structures have experimented and their results were compared to the analytical results to evaluate the reducing effect of thermal stress. For a large $6.5m{\times}6.5m{\times}3.5m$ member with retarding and standard type horizontal partition placement of concrete showed the manageable possibility of temperature difference within 25-degree Celcius between the middle and surface portion while the maximum temperature was 77-degree Celcius. Also, temperature cracking index from the finite element analysis appeared to be 1.49 that predicts no formation of cracking due to the effects of temperature. Finally, it appeared that horizontal partition placement of retarding and standard type concrete has the significant effect of reducing the thermal stress that generated by the hydration heat in the high strengths mass concrete.

Evaluation of Flexural Behavior of Hollow Prestressed Concrete Pile for Continuous Pile Wall (주열식 벽체용 중공 프리스트레스트 콘크리트 파일의 휨거동 평가)

  • Lee, Young-Geun;Jang, Min-Jun;Yoon, Soon-Jong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.3
    • /
    • pp.20-27
    • /
    • 2014
  • In the construction site, various earth retaining systems are developed and applied to maintain stability of excavated area and structures. Among the methods, the underground continuous wall and the column-type diaphragm wall methods are especially used in construction site nearby buildings or roads. However, these methods have some disadvantages such as the difficulty of quality control and long curing time because these methods need to cast fresh concrete at the construction site. In addition, these methods are usually applied to the site for the temporary purpose. In this paper, we suggest precast hollow prestressed concrete pile for continuous pile wall system. To investigate the structural behavior of suggested pile, which is the main member of the suggested system, tests pertaining to the structural behavior and prestressing force applied in the pile are conducted. From the test results, it was found that the prestressing force measured is sufficient compared with the value obtained by the design equation and the cracking moment measured is 34% higher than the design value. In addition to the above, this precast hollow prestressed concrete pile has an additional safety margin that the maximum moment is 59.2% higher than the cracking moment which is one of the serviceability limits for the design of the system.

A study on the color controlled of painter's work (페인트 도장공사의 색관리에 관한 연구)

  • Shim, Myung-Sup;Lee, Hyun-Jeong
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.1
    • /
    • pp.107-114
    • /
    • 2003
  • This study aims to find methods that prevents aging of buildings paint coating and that limits defects in construction. Defects in painting can occur in four stages: pure paint, during painting, after the paint coating has dried, and after some period of time has passed after coating. Paint may become bad due to precipitation of pigments, formation of membranes, and seeding during manufacturing. Therefore, it is important that the paint is well mixed and kept airtight at a cool, dark place. Indents, paint brush strokes, orange peel, separation of colors, and paint running and spreading during the paint work process can be prevented by using high quality materials and applying a high-level of construction method. After the paint coating has dried, boiling, yellowing, poor drying, poor bonding, and/or glen deficiency may occur. These are influenced by the levels of cleanness of the dried product, drying temperature and hydration. Then, when the coating has been left dried for some period of time, cracking, peeling, scaling, swelling, discoloring, and/or rusting may develop due to the ultraviolet and contaminants in the air. Since these defects occur due to inappropriate construction schedule and/or hot and humid condition, one must use weatherproof materials. Furthermore, poor paint color may be caused by contamination in the sample plate, discoloration, and/or discrepancies in colors which are due to material differences, level of glossiness, degree of dispersion, dual color property of metallic colors, precipitation of pigments, etc. One should achieve reduction in construction cost and effectiveness in paint work by limiting contaminations in the construction site and strictly observing to construction regulations.

A Study on Degradation Characteristic of High Strength Fire Resistance Steel for Frame Structure by Acoustic Emission (음향방출법에 의한 고강도 구조용 내화강의 열화특성에 관한 연구)

  • Kim, H.S.;Kang, C.Y.;Nam, K.W.;Kim, B.A.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.13 no.5
    • /
    • pp.309-317
    • /
    • 2000
  • Demand for new nondestructive evaluations is growing to detect tensile crack growth behavior to predict long term performance of materials and structure in aggressive environments, especially when they are in non-visible area. Acoustic emission technique is well suited to these problems and has drawn a keen interests because of its dynamic detection ability, extreme sensitivity and location of growing defects. In this study, we investigated the strength of fire resistance steel for frame structure by tensile test after degradation treatment and analysed acoustic emission signals obtained from tensile test with time frequency analysis methods. In the T and TN specimens(under $600^{\circ}C$-10min ) consisting of ferrite and pearlite structure, most of acoustic emission events were produced near yield point, mainly due to the dislocation activities during the deformation. However, B specimen under $600^{\circ}C$-10min had a two peak which was attribute to the presence of martensite phase. The first peak is before yield point and the second after yield point. The sources of second acoustic emission peak were the debonding of martensite-martensite interface and the micro-cracking of brittle martensite phase. In $600^{\circ}C$-30min to $700^{\circ}C$-60min, many signals were observed before yield point and were decreased after yield point.

  • PDF

해양환경하에서의 알루미늄 합금 선박용 재료의 기계적 특성과 전기화학적 특성 평가

  • 김성종;고재용;정석기;김정일
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.05a
    • /
    • pp.161-165
    • /
    • 2005
  • Recently, it is on the increase interest for Al alloy with new material for ship application to substitute for FRP ship. The reason is thatAl alloy ship has beneficial characteristics such as high sea speed, increase of loadage and easy to recycle compared with FRP ship. In this paper, mechanical and electrochemical properties are investigated by slow strain rate test experiment in various applied potential condition. These results will provide as reference data to design ship by deciding optimum protection potential regard to hydrogen embrittlement and stress corrosion cracking. In general, Al and Al alloys are not corroded with forming film which has the corrosion resistance property in neutral solution. However, it was observed that formation and destruction of passive film by $Cl^-$ ion in sea water environment. At comparison of current density after 1200 sec in potentiostatic experiment, the current density in the potential range of -0.68 $\~$-1.5 V is shown low value. The low current density means protection potential range. Elongation in applied potential of 0 V was high. However, the corrosion protection application in this condition is impossible potential because the toughness is low value by decreasing strength by active dissolution reaction at parallel part of specimen. The film composed with $CaCO_3$ and $Mg(OH)_2$ has a corrosion resistance property. However, the uniform electrodeposition coating at below -1.6 V potential is not formed since the time to form the uniform electrodeposition coating is short. Therefore, it is concluded that mechanical property is poor because effect by hydrogen gas generation is larger than that of electrodeposition coating. It is concluded that the optimum protection potential range from comparison of_maxim urn tensile strength, elongation and time to fracture is -1.3$\~$0.7 V (SSCE).

  • PDF

The study on Accelerated Life-Time Reliability Test Methods of Ni-Mn-B ternary alloy Plating(electrodeposit) (Ni-Mn-B 삼원합금도금 가속수명 및 신뢰성 평가에 대한 연구)

  • Ma, Seung-hwan;Noh, young-tai;Jang, gun-ik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.2993-2999
    • /
    • 2015
  • Steel companies are applying Ni-B or Ni-Co alloy plating to protect the surface of Continuous casting mold, and they are using saccharin polish which causes crack on plating layer due to sulfur in saccharin. It is considered that the Ni-S compound causes the cracking and additional tensile stresses. The Ni-Mn-B ternary alloy plating was developed for suppression of crack by forming Mn-S compound before Ni-S compound is formed, but there were no domestic or international standard on the Ni-Mn-B alloy plating. Therefore, reliability evaluation standard was established to evaluate the newly developed Ni-Mn-B plating. To develop accelerating life testing method, FMEA(Failure Mode & Effective analysis) was used to analyze the cause of the main failure in plating. The Ni-Mn-B reliability standard included accelerating life test method, and it was categorized by the fundamental performance test, environment test, and accelerated life test, and was designed to guarantee 1 000 hours of B10 life with 80 % reliable level.

Automated detection of corrosion in used nuclear fuel dry storage canisters using residual neural networks

  • Papamarkou, Theodore;Guy, Hayley;Kroencke, Bryce;Miller, Jordan;Robinette, Preston;Schultz, Daniel;Hinkle, Jacob;Pullum, Laura;Schuman, Catherine;Renshaw, Jeremy;Chatzidakis, Stylianos
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.657-665
    • /
    • 2021
  • Nondestructive evaluation methods play an important role in ensuring component integrity and safety in many industries. Operator fatigue can play a critical role in the reliability of such methods. This is important for inspecting high value assets or assets with a high consequence of failure, such as aerospace and nuclear components. Recent advances in convolution neural networks can support and automate these inspection efforts. This paper proposes using residual neural networks (ResNets) for real-time detection of corrosion, including iron oxide discoloration, pitting and stress corrosion cracking, in dry storage stainless steel canisters housing used nuclear fuel. The proposed approach crops nuclear canister images into smaller tiles, trains a ResNet on these tiles, and classifies images as corroded or intact using the per-image count of tiles predicted as corroded by the ResNet. The results demonstrate that such a deep learning approach allows to detect the locus of corrosion via smaller tiles, and at the same time to infer with high accuracy whether an image comes from a corroded canister. Thereby, the proposed approach holds promise to automate and speed up nuclear fuel canister inspections, to minimize inspection costs, and to partially replace human-conducted onsite inspections, thus reducing radiation doses to personnel.

A Novel Method for In Situ Stress Measurement by Cryogenic Thermal Cracking - Concept Theory and Numerical Simulation (저온 열균열 현상을 이용한 초기 응력 측정법 - 개념, 이론 및 수치해석)

  • Ryu, Chang-Ha;Ryu, Dong-Woo;Choi, Byung-Hee;Synn, Dong-Ho;Loui, John P.
    • Tunnel and Underground Space
    • /
    • v.18 no.5
    • /
    • pp.343-354
    • /
    • 2008
  • A new method is suggested herein to measure the virgin earth stresses by means of a borehole. This novel concept is basically a combination of borehole stress relieving and borehole fracturing techniques. The destressing of the borehole is achieved by means of inducing thermal tensile stresses at the borehole periphery by using a cryogenic fluid such as Liquid Nitrogen($LN_2$). The borehole wall eventually develops fractures when the induced thermal stresses exceed the existing compressive stresses at the borehole periphery in addition to the tensile strength of the rock. The above concept is theoretically analyzed for its potential applicability to interpret in situ stress levels from the tensile fracture stresses and the corresponding borehole wall temperatures. Coupled thermo-mechanical numerical simulations are also conducted using FLAC3D, with thermal option, to check the validity of the proposed techniques. From the preliminary theoretical and numerical analysis, the method suggested for the measurement of in situ stresses appears to be capable of accurate estimation of the virgin stresses by monitoring tensile crack formation at a borehole wall and recording the wall temperatures at the time of crack initiation.