• Title/Summary/Keyword: time reversible

Search Result 220, Processing Time 0.033 seconds

Implementation of Lightweight Block Cipher for Ubiquitous Computing Security (유비쿼터스 컴퓨팅 보안을 위한 경량 블록 암호 구현)

  • Kim, Sung-Hwan;Kim, Dong-Seong;Song, Young-Deog;Park, Jong-Sou
    • Convergence Security Journal
    • /
    • v.5 no.3
    • /
    • pp.23-32
    • /
    • 2005
  • This paper presents a 128-bit Reversible Cellular Automata (RCA) based lightweight block cipher for Ubiquitous computing security. To satisfy resource-constraints for Ubiquitous computing, it is designed as block architecture based on Cellular Automata with high pseudo-randomness. Our implementation requires 704 clock cycles and consumes 2,874 gates for encryption of a 128-bit data block. In conclusion, the processing time outperformed that of AES and NTRU by 31%, and the number of gate was saved by 20%. We evaluate robustness of our implementation against both Differential Cryptanalysis and Strict Avalanche Criterion.

  • PDF

Usefulness of Myocardial Perfusion SPECT after Percutaneous Coronary Intervention (PCI) (경피적 관상동맥 중재술(Percutanerous Coronary Intervention; PCI) 후 심근 관류 SPECT의 유용성)

  • Lee, Jong-Jin;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.114-117
    • /
    • 2005
  • As the indication of percutaneous coronary intervention (PCI) has expanded to the more difficult and complicated cases, frequent restenosis is still expected after PCI. According to AHA/ACC guideline of the present time, routine use of myocardial perfusion single photon emission tomography (SPECT) is not recommended after coronary intervention, but symptom itself or exercise EKG is not enough for the detection of restensis or for the prediction of event-free survival. In high risk and/or symptomatic subjects, direct coronary angiography is required myocardial perfusion SPECT could detect restenosis in 79% of the patients if performed 2 to 9 months after PCI. Reversible perfusion decrease in the myocardial perfusion SPECT is known to be the major prognostic indicator of major adrerse cardiac event in PCI patients and also the prognosis is benign in the patients without reversible perfusion decrease. Though the cumulated specificity is 79% in the literature and optimal timing of myocardial perfusion SPECT is in controversy, SPECT is recommended even in asymptomatic patients at 3 to 9 months after PCI. Considering the evidences recently reported in the literature, myocardial perfusion SPECT is useful for risk stratification and detection of coronary artery restenosis requiring re-intervention in the asymptomatic patients after PCI.

Hybrid marine propulsion power system with the redox flow batteries of comprehensive aging model

  • Yoo, Seunghyeon;Aguerrevere, Jorge;Jeong, Jinyeong;Jung, Wongwan;Chang, Daejun
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.13 no.1
    • /
    • pp.674-690
    • /
    • 2021
  • This study proposes a hybrid marine power system combining dual-fuel generators, a fuel cell, and Vanadium Redox Flow Batteries (VRFB). Rigorous verification and validation of the dynamic modelling and integration of the system are conducted. A case study for the application of the hybrid propulsion system to a passenger ship is conducted to examine its time-variant behaviour. A comprehensive model of the reversible and irreversible capacity degradation of the VRFB stack unit is proposed and validated. The capacity retention of the VRFB stack is simulated by being integrated within the hybrid propulsion system. Reversible degradation of the VRFB stack is precisely predicted and rehabilitated based on the predefined operational schedule, while the irreversible portion is retained until the affected components are replaced. Consequently, the advantages of the VRFB system as an on-board ESS are demonstrated through the application of a hybrid propulsion system for liner shipping with fixed routes.

Syntheses and Photostability of Unsymmetrical Squarylium Dyes for Organic Photoconductors(OPC) (유기광전도재료 (OPC)용 비대칭 Squarylium계 색소의 합성과 광안전성)

  • 김성훈
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.12 no.1
    • /
    • pp.133-143
    • /
    • 1994
  • A new photochromic spiroxazine dye having a pyridinium s-triazine moiety has been prepared. It shows a reversible photochemical color change from colorless to reddish-purple in ethanol solution. In ethanol solution the half life time of the open form was 150sec, which was shortened by raising temperature. Silica-immobilized spiroxazine(6). Fine power of silica-immobilized spiroxazine was changed intensely blue from colorless by U.V. light or sunlight.

  • PDF

Organic Gas Response Characteristics of Maleate Copolymer LB Films (말레에이트 공중합체 LB막의 유기 가스 반응 특성)

  • 이을식;김도균;유승엽;최용성;권영수;박재철
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.415-418
    • /
    • 1998
  • The maleate copolyrner($C_{18}MA-VE_2$) is used as sensitive materials and deposited on the slide-glass substrates at room temperature using Langmuir-Blodgett(LB) method. The results of current-time(1-t) measurements are performed to investigate the gas-detection characteristics of the sensitive LB films in the presence of organic gases just as chloroform, acetone, ethanol, methanol using the apparatus for the gas-detection measurement. Several interesting responses are observed at room temperature, such as reversible response, sensitivity and response time. Response time and sensitivities are evaluated 160~220[sec], minimum 6[times], maximum 70[times] for each organic gas by adsorption and penetration of the organic gases in the relation concentration of 100[%], respectively.

  • PDF

The Performance Analysis of Hierarchical Cellular System According to Dwell Time (Dwell Time에 따른 계층 셀룰라 시스템의 성능 분석)

  • Seong, Hong-Seok;Won, Young-Jin;Yun, Ki-Bang
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.471-472
    • /
    • 2007
  • At this paper, we use non reversible hierarchical scheme and fixed channel assignment scheme at the hierarchical cellular system with macrocell and microcell for the call process strategy Using this strategy, we analyze the system performance in accordance with the various dwell time at each cell. In this simulation result, the more the dwell time is small at microcell, the more the blocking probability and the handover failure probability is low.

  • PDF

Sensitivity Changes of Auxin Transport System in Maize Coleoptile Segments

  • 윤인선
    • Journal of Plant Biology
    • /
    • v.36 no.1
    • /
    • pp.59-66
    • /
    • 1993
  • In maize coleoptile segments where auxin transport capacity decreases with time following excision, susceptability of the tissue to transport inhibitors such as N-1-naphthylphthalamic acid (NPA), 3,4,5-triiodobenzoic acid (TIBA) or high concentrations of IAA was found to be rather increased. A time-dependent increase in the sensitivity to NPA can be postulated since the dose-response curve for NPA was shifted in the‘aged’tissue to the left (i.e. lower concentration). Preincubation of the tissue at a low temperature abolished the time-dependent sensitivity change, suggesting that cellular metabolism could be involved. The NPA-sensitive state was also brought about by calcium depletion of the tissue, which can be partially reversed by addition of calcium. Presence of exogenous IAA in the preincubation medium kept the auxin transport system from decay, implicating auxin as an endogenous controlling factor. Results of our experiments indicate a reversible, time-dependent changes of auxin transport system in which transport capacity and sensitivity to NPA are tightly coupled. Changes in the sensitivity to NPA were also seen in auxin action as well.

  • PDF

Experimental Analysis in the Reversible and Irreversible Cerebral Ischemic Models in the Rat (백서의 가역성 및 비가역성 뇌허혈 모형의 실험적 고찰)

  • Song, Kwang Chul;Choi, Byung Yon;Kim, Seong Ho;Bae, Jang Ho;Kim, Oh Lyong;Cho, Soo Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.7
    • /
    • pp.853-860
    • /
    • 2000
  • Objective : The purpose of our experimental study was to analysis the advantages and disadvantages in the reversible and irreversible cerebral ischemic models with rats by staining with Neutral Red(NR) solusion, 2% 2,3,5-triphenyltetrazolium chloride(TTC) and Hematoxylin & Eosin(H & E). Methods : We have measured the range of cerebral infarction in the rat to get a suitable ischemic model along the object of study with and without craniectomy. With craniectomy, 9 rats were sacrificed for irreversible cerebral ischemic model by means of ligation at proximal(group I) and distal(group II), and coagulation at proximal(group III) middle cerebral artery. Also, 6 rats were sacrificed for irreversible(group IV) and reversible(group V) cerebral ischemic model using nylon thread without craniectomy. The sizes of infarction were measured by staining the coronal sections of the brain with NR solusion, TTC and H & E. Results : There are no difference of physiological parameters comparing the each group. Cerebral infarction was not observed in group II, but it's volume was largest in group IV. Disadvantages of craniectomy group(I, II, III) are the long duration of operation and cortical damage by procedure. It's advantage is confirmation of the middle cerebral artery occlusion and cessation of blood flow through the operative microscope. In case of ischemic models using nylon thread (group IV, V), it is hard to identify the interruption or recirculation of blood flow through the middle cerebral artery, but the advantage is the simplicity of operative technique which reduces the operation time and minimizes the cerebral damage due to craniectomy. Therefore, it seems important to set up the reversible and irreversible ischemic models by carefully considering advantages and disadvantages listed above. Conclusion : TTC staining seems to be effective since it reflects the histological damage sufficiently and quickly. It is hoped that researches focused on ischemic penumbra, which became popular recently, will be further carried on with use of NR staining, optical microscope and electron microscope.

  • PDF

Trapezoidal Cyclic Voltammetry as a Baseline for Determining Reverse Peak Current from Cyclic Voltammograms

  • Carla B. Emiliano;Chrystian de O. Bellin;Mauro C. Lopes
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.405-413
    • /
    • 2024
  • Several techniques for determining the reverse peak current from a cyclic voltammogram (CV) for a reversible system are described in the literature: CV itself as a baseline with long switching potential (Eλ) that serves as a baseline for other CVs, Nicholson equation that uses CV parameters to calculation reverse peak current and linear extrapolation of the current obtained at the switching potential. All methods either present experimental difficulties or large errors in the peak current determination. The paper demonstrates, both theoretically and experimentally, that trapezoidal cyclic voltammetry (TCV) can be used as a baseline to determine anodic peak current (iap) with high accuracy and with a switching potential shorter than that used by CV, as long as Eλ is at least 130 mV away from the cathodic peak. Beyond this value of switching potential the electroactive specie is completely depleted from the electrode surface. Using TCV with Eλ = 0.34 V and a switching time (tλ) of 240 s as a baseline, the determination of the reverse peak current presents a deviation from the expected value of less than 1% for most of the CVs studied (except cases when Eλ is close to the direct potential peak). This result presents better accuracy than the Nicholson equation and the linear extrapolation of the current measured at the switching potential, in addition to presenting a smaller error than that obtained in the acquisition of the experimental current. Furthermore, determining the reverse peak current by extrapolating the linear fit of iap vs. ${\sqrt[1/]{t_{\lambda}}}$ to infinite time gave a reasonable approximation to the expected value. Experiments with aqueous potassium hexacyanoferrate (II) and ferrocene in acetonitrile confirmed the theoretical predictions.

SPR-based Antibody-Antigen Interaction for Real Time Analysis of Carbamate Pesticide Residues

  • Yang, Gil-Mo;Kang, Suk-Won
    • Food Science and Biotechnology
    • /
    • v.17 no.1
    • /
    • pp.15-19
    • /
    • 2008
  • This research was conducted to develop a quick and sensitive method of detecting carbamate residues using the immobilization of antibody-antigen interactions with surface plasmon resonance (SPR). We have used commercialized surface plasmon resonance equipment (Biacore 3000). The antibody used for the immunoassay was specific for glutathione-s-transferase (GST) and the antigens included several carbamate pesticides (carbofuran, carbaryl, and benfuracarb). When antigens were applied to the protein GST, the detection limit was 2 ng/mL of carbamate pesticide. The fabricated protein GST maintained its activity for over 200 measurements. Thus we determined that the SPR biosensors could detect the specific reversible binding of a reactant in solution to a binding partner immobilized on the surface of the sensor and allow real-time detection and monitoring.