• Title/Summary/Keyword: time pass

Search Result 1,111, Processing Time 0.029 seconds

Time-Domain Numerical Investigation of Ring Resonator Optical Delay Devices

  • Chung, Youngchul
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.441-446
    • /
    • 2013
  • A split-step time-domain model for the analysis of pulse delay characteristics through ring resonator all-pass filters (APF's) is developed and its accuracy is checked. The dependence of the delay time and pulse distortion on the coupling ratios is investigated using the model. It is observed that the bandwidth of the APF's needs to be wide enough to minimize the pulse distortion.

The Design and Application of IIR Variable Bandwidth Filter (IIR 가변대역폭 필터의 설계 및 응용에 관한 연구)

  • Song, Min;Baek, Seung-Eun;Choe, Jin-Myung;Bien, Zeung-Nam;Lee, He-Young
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.138-141
    • /
    • 2001
  • In this paper, a VBF(variable bandwidth filter) is suggested and analyzed in time-frequency domain. There are four kinds of VBF, which are low-pass VBF, high-pass VBF, band-pass VBF and band-stop VBF. The proposed VBF can extract the components of signals within variable instantaneous bandwidth at a specific time instant. Instantaneous bandwidth is estimated in time-frequency domain. The VBF is represented by rational form in extended Fourier frequency domain.

  • PDF

The time response of second order band pass filter (2차식 대역통과여파기의 시간응답)

  • 고병준;김재공
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.5
    • /
    • pp.20-26
    • /
    • 1971
  • A function relationship between the envlope rise time and Q v91ue of band pass filter is studied by using the time response to the step and sinusodal inputs. It is discovered that the above relationship is linear in the very low frequency band. The filter was constructed by the Analog computer so as to do the function of 2nd order RC active band pass.

  • PDF

A Design of 20 MHz CMOS Continuous Time Low-Pass Filter Using Linear Transconductors (선형 트랜스컨덕터를 이용한 20 MHz CMOS 연속시간 저역-통과 여파기의 설계)

  • 박희종;박상렬;김동용;차형우;정원섭
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.357-360
    • /
    • 1999
  • A 20 MHz CMOS continuous low-pass filter using simulated floating inductor consisted of two fully-differential transconductors and a capacitor is presented. The theory of operation is described and simulation results show close agreement between predicted behaviour and experimential performance. Simulation results show that the filter has ripple bandwidth of 22 MHz, pass-band ripple of 0.36 ㏈. and cutoff frequency of 26 MHz at supplay voltage of $\pm$3 V. The power dissipation is 19.2 ㎽.

  • PDF

PITCH EXTRACTION USING AN APROXIMATELY IDEAL LOW-PASS FILTER

  • Matsuoka, T.;Sugama, A.;Onodera, E.;Ishida, Y.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.931-936
    • /
    • 1994
  • Although an ideal low-pass filter is not physically realizable, it can be approximated on the basis of time reversal techniques. In this paper, we describe a method to approximately implement the ideal low-pass filter and apply it to the pitch extraction system. Experimental results show that our method is effective to estimate the fundamental frequency of the speech signal.

  • PDF

Effects of the Frequency Band Pass Filter on the P300 Event-related Potential in the Working Memory (주파수 통과대역필터가 작업 기억 관련 사건관련전위 P300에 미치는 영향)

  • Park, Woongsik;Lee, Jeongwoo
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.2
    • /
    • pp.131-138
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effects of the frequency band pass filter on the P300 event-related potential in the working memory. Methods : The subjects were 20 women in their 20s who applied for participation in the experiment. Event-related potentials (ERPs) were elicited using 3-back tasks for the working memory, and were recorded from Fz, Cz, and Pz scalp electrodes. The high-pass filters were set to 0.01, 0.1, and 0.3 Hz for analysis purposes, and the low-pass filters were set to 30 and 15 Hz. The 3-back task was presented for a total of 100 times, among which 30 times were designated for the target stimulation (a matched number) and 70 times for the non-target stimulation (an unmatched number). The temporal interval between each stimulation was set at 1 second, while each time duration was randomly presented between 2 to 4 seconds. ERP were analyzed for the P300 recorded from Fz, Pz and Cz scalp electrodes. Results : Latency and amplitude had no significant interaction effects in both the high- and low-pass filters. For the main effects, the latency and amplitude of the P300 event-related potential had no significant difference in the high-pass filters, but the latency had a significant difference in the low-pass filter of Fz, and the amplitude had a significant difference in the low-pass filter of Pz. Conclusion : The results of this study showed that the less than 0.3 Hz high filters had no effects on the differences between the latency and amplitude of the P300 event-related potential in the working memory. The 30Hz low-pass filter, however, was found to be useful for recording the P300 event-related potential in the working memory.

Safety Improvement of Centrally Installed "Hi-pass" Lane of Express Highway (고속도로 중앙하이패스차로 안전성 개선에 관한 연구 - 서울외곽순환고속도로 본선영업소를 중심으로 -)

  • Yoo, Bong-Seok;Lee, Soo-Beom;Park, Wan-Yong;Do, Hyun-Gu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.1D
    • /
    • pp.1-10
    • /
    • 2010
  • Safety improvement has been a continuous challenge, especially at toll gate of express highway where traffic conflict often occurs due to frequent lane change by drivers of "Hi-pass" lane and regular "TCS" lane. As a part of research on safety at toll gate, this study videotaped traffic conflict data between vehicles using centrally located "Hi-pass" lane and regular "TCS" lane and analyzed accident risk. According to the correlation analysis of vehicle speed, relative vehicle speed, and sudden vehicle deceleration rate due to traffic conflict, when the relative vehicle speed between centrally located "Hi-pass" lane and regular "TCS" lane increases, sudden vehicle deceleration rate also increases. One of the findings is that centrally located "Hi-pass" lane at toll gate shows different location for traffic conflict, and frequency of traffic conflict and the relative vehicle speed was also different based on vehicle lane use. TA (Time to Accident) analysis shows that accident rate is high at toll gate where Hipass lane is installed in center lane, when the occurrence of sudden vehicle deceleration and deceleration time of vehicles rise for vehicles on "Hi-pass" lane. Furthermore, if the expressway entrance/exit point is closely located to toll gate, TA showed a low value. Thus, it is necessary to reduce the relative vehicle speed in order to improve safety. The Study presents reduction of the relevant vehicular speed and prevention of accidents at the centrally installed "Hi-pass" lane as an important strategy for safety improvement at toll gate.

Water Quality Change Characteristics of Treated Water in Distribution System of Water Treatment Plant of Jeiu City (제주시 정수장 처리수의 급수과정별 수질변화 특성)

  • Han, Kyung-Yong;Lee, Min-Gyu;Chung, Ho-Jin;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of $NO_3^-$ and $Cl^-$ of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and $CHCl_3$ that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.

High Frequency Noise Reduction Method Using a Newly Designed Low-pass Filter in DFT-Based Phasor Estimation (DFT 기반 페이저 연산 시 새로운 저역통과필터를 이용한 고주파 노이즈 경감 방법)

  • Baek, Min-Woo;Kang, Sang-Hee
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.898-904
    • /
    • 2017
  • DFT(Discrete Fourier Transform) is one of the most widely used method to estimate the phasor of a relaying signal. The harmonics are eliminated by the DFT. However, high frequency components, except for harmonics, are not removed and cause an error in DFT-based phasor estimation process. This paper suggests high frequency noise reduction method by using a newly designed low-pass filter to estimate a signal phasor. When selecting a stop-band cut-off frequency of the low-pass filter, high frequency components generated by faults are considered. To reduce the phasor estimation delay caused by a low-pass filter, this paper proposes a low-pass filter whose settling time is reduced. An adverse effect of high frequency noise on DFT-based phasor estimation is reduced. To evaluate the performance of the proposed method, signals which are collected under a fault condition at a 345[kV] transmission system modeled by EMTP-RV are used.

Declining Temperature Multistage Deformation Behavior of Nb-Microalloyed Structural Steel (Nb 첨가 구조용강의 감온단속변형)

  • 조상현;오명석;소찬영;유연철
    • Transactions of Materials Processing
    • /
    • v.3 no.4
    • /
    • pp.415-426
    • /
    • 1994
  • Multistage deformation behavior of Nb-microalloyed steel and carbon steel was studied by torsion test with declining temperature T, constant pass strain $\varepsilon_i$, interrupt time $(t_i)$, and varying strain rate $(\.{\varepsilon})$. In the range of $1000^{\circ}C~790^{\circ}C$ and 4.00/sec~0.38/sec, the flow stress at each pass was correlated to the deformation variables. As the finished deformation temperatures are decreased to the range of $790^{\circ}C~900^{\circ}C$, Nb precipitates play an important role on the grain refinement of Nb-microalloyed steel. the flow stress of Nb-microalloyed steel was higher than the carbon steel's while the grain size of Nb-microalloyed steel was smaller than carbon steel below the temperature of $900^{\circ}C$.

  • PDF