• Title/Summary/Keyword: time of stall

Search Result 67, Processing Time 0.03 seconds

Experimental Study on Stall Inception in a High-Speed Centrifugal Compressor ( II )- Stall Warning Method - (원심압축기 스톨 발단에 판한 실험적 연구 (II) - 스톨 경고 방법 -)

  • Gang, Jeong-Sik;Gang, Sin-Hyeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1445-1450
    • /
    • 2001
  • Stall inception in a high-speed centrifugal compressor has been examined. The main objective was to find stall precursor and to develop a reliable stall warning method. For stall warning, a method which uses the spectrum at impeller frequency is suggested. The use of the spectrum at impeller frequency as a stall warning method showed a warning time of about two hundreds impeller revolutions. This method uses only one sensor that it has made the stall warning method more useful. And the well-known traveling wave energy method proved to be a good method for stall warning also in a high-speed centrifugal compressor. The warning time was about one hundred impeller revolutions at lower speeds, and about one thousand impeller revolutions at higher speeds. The stall warning methods used here were found to be robust and reliable. Therefore, it seems to be promising to set up a reliable stall avoidance control based on this analysis.

A Three-Dimensional Numerical Simulation of Rotating Stall in an Axial Compressor (축류 압축기에서의 선회실속에 관한 3차원 수치해석)

  • Choi, Min-Suk;Oh, Seong-Hwan;Ki, Dock-Jong;Baek, Je-Hyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.1 s.256
    • /
    • pp.68-75
    • /
    • 2007
  • A three-dimensional computation is conducted to simulate a three-dimensional rotating stall in a low speed axial compressor. It is generally known that a tip leakage flow has an important role on a stall inception. However, almost of researchers have taken no interest in a role of the hub-comer-stall on the rotating stall even though it is a common feature of the flow in an axial compressor operating near stall and it has a large effect on the flows and loss characteristics. Using a time-accurate unsteady simulation, it is found that the hub-comer-stall may be a trigger to collapse the axisymmetric flows under high loads. An asymmetric disturbance is initially originated in the hub-comer-stall because separations are naturally unstable flow phenomena. Then this disturbance is transferred to the tip leakage flows from the hub-comer-stall and grows to be stationary stall cells, which adheres to blade passage and rotate at the same speed as the rotor. When stationary stall cells reach a critical size, these cells then move along the blade row and become a short-length-scale rotating stall. The rotational speed of stall cells quickly comes down to 79 percent of rotor so they rotate in the opposite direction to the rotor blades in the rotating frame.

Numerical and Experimental Investigations of Dynamic Stall

  • Geissler, Wolfgang;Raffel, Markus;Dietz, Guido;Mai, Holger
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.19-19
    • /
    • 2009
  • Dynamic Stall is a flow phenomenon which occurs on the retreating side of helicopter rotor blades during forward flight. It also occurs on blades of stall regulated wind turbines under yawing conditions as well as during gust loads. Time scales occurring during this process are comparable on both helicopter and wind turbine blades. Dynamic Stall limits the speed of the helicopter and its manoeuvrability and limits the amount of power production of wind turbines. Extensive numerical as well as experimental investigations have been carried out recently to get detailed insight into the very complex flow structures of the Dynamic Stall process. Numerical codes have to be based on the full equations, i.e. the Navier-Stokes equations to cover the scope of the problems involved: Time dependent flow, unsteady flow separation, vortex development and shedding, compressibility effects, turbulence, transition and 3D-effects, etc. have to be taken into account. In addition to the numerical treatment of the Dynamic Stall problem suitable wind tunnel experiments are inevitable. Comparisons of experimental data with calculated results show us the state of the art and validity of the CFD-codes and the necessity to further improve calculation procedures. In the present paper the phenomenon of Dynamic Stall will be discussed first. This discussion is followed by comparisons of some recently obtained experimental and numerical results for an oscillating helicopter airfoil under Dynamic Stall conditions. From the knowledge base of the Dynamic Stall Problems, the next step can be envisaged: to control Dynamic Stall. The present discussion will address two different Dynamic Stall control methodologies: the Nose-Droop concept and the application of Leading Edge Vortex Generators (LEVoG's) as examples of active and passive control devices. It will be shown that experimental results are available but CFD-data are only of limited comparison. A lot of future work has to be done in CFD-code development to fill this gap. Here mainly 3D-effects as well as improvements of both turbulence and transition modelling are of major concern.

  • PDF

A Study of the Stall Keeper Behavior Characterictics in Urban Area ( I ) (도시생활에 있어서 노점상의 행태특성에 관한 연구( I ))

  • 김한수
    • Journal of the Korean housing association
    • /
    • v.8 no.2
    • /
    • pp.113-122
    • /
    • 1997
  • This study analyzes behavior characteristics of illegal urban stall keepers scattered in the metropolitan area and their effects to urban life. The main findings of this study are follows. First, the stall keepers are different in terms of 1) items 2) opening hour and 3) user characteristics depending on locational environment of market boundaries. Second, the stall keepers exit in any time and any place if demand exists. Third, the effects of stall keepers to urban life are twofold ; they facilitate urban life by providing cheap and various commodities/services and they bring about negative effects such as obstacle to traffic flows, waste generation, and so on.

  • PDF

An experimental study on rotating stall in vaneless diffuser of a centrifugal compressor (원심압축기 깃 없는 디퓨저에서의 선회실속에 관한 실험적 연구)

  • Sin, Yu-Hwan;Kim, Gwang-Ho;Son, Byeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.153-161
    • /
    • 1998
  • This study describes the results of the analysis of measured rotating stall signal in a centrifugal compressor with vaneless diffuser. Unsteady flow and rotating stall in vaneless diffuser were investigated by measuring of unsteady velocity fluctuation using hot-wire anemometer. Experiments were carried out in several impeller rotating speeds, at different radius ratios. Single hot -wire was used to study the characteristics of rotating stall. As a result, the abrupt rotating stall was detected at all measured impeller rotating speeds and the several flow coefficients which are less than 0.16. The number of the stall cell was one at all measured rotational speeds, and the rotating direction was the same as that of the impeller. As the flow rate decreased, the profile of the phase averaged radial velocity component with time changed from a sawtooth to a sine wave.

The analysis on centrifugal compressor rotating stall (원심압축기의 선회실속 분석)

  • Kim, Ji-Hwan;Kim, Kwang-Ho;Shin, You-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.834-839
    • /
    • 2003
  • In the present study, the performance characteristics and the number of stall cells during rotating stall of a centrifugal air compressor were experimentally investigated. If the flow coefficient is lower than 0.150, the static pressure at impeller inlet is higher than that at inlet duct And reverse flow is observed under these flow coefficient region. Maximum adiabatic efficiency is obtained for the tested compressor around flow coefficient 0.128, and it is independent of compressor rotating speed. The number of stall cells and their rotational speeds are distinctive features of the rotating stall phenomenon. The present study is mainly concerned with the number of stall cells and their rotational speeds. The interpretation method of visualization is based on the pressure distribution in the circumference pressure fields while plotting the pressure and its harmonics variations in time in polar coordinates.

  • PDF

Dynamic Stall Control Using Aerodynamic Sensitivity Analysis (민감도 해석을 이용한 동적실속 제어)

  • Ahn Tai-Sul;Kim Hyoung-Jin;Kim Chongam;Rho Oh-Hyun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.176-182
    • /
    • 2000
  • This paper presents methods for dynamic stall control utilizing an optimization approach. Unsteady aerodynamic sensitivity code is developed using a direct diffentiation method from a discrete two-dimensional unsteady compressible Navier-Stokes code including a two-equation turbulence model. Dynamic stall control is conducted by minimizing an objective function defined at an instant instead of integrating a response for a period of time. Unsteady sensitivity derivative of the objective function is calculated by the sensitivity code, and optimization is conducted using a linear line search method at every physical time level. Examples of dynamic stall control utilizing airfoils nose radius or maximum thickness variation show very satisfactory results.

  • PDF

Dynamic Stall Control Using Aerodynamic Sensitivity Analysis (민감도 해석을 이용한 동적실속 제어)

  • Ahn, Tai-Sul;Kim, Hyoung-Jin;Kim, Chong-Am;Rho, Oh-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.8
    • /
    • pp.10-20
    • /
    • 2002
  • The present paper investigates methods to control dynamic stall using an optimal approach. An unsteady aerodynamic sensitivity analysis code is developed by a direct differentiation method from a two-dimensional unsteady compressible Navier-Stokes solver including a two-equation turbulence model. Dynamic stall control is conducted by minimizing an objective function defined at an instant instead of integrating for a period of time. Unsteady sensitivity derivatives of the objective function are calculated by the sensitivity code, and optimization is carried out using a linear line search method at every physical time step. Numerous examples of dynamic stall control using control parameters such as nose radius, maximum thickness of airfoil, or suction show satisfactory results.

Apparatus for Measuring Fan Stall of Boiler for Power Station (화력발전용 보일러의 맥동 측정 장치)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1681-1684
    • /
    • 2014
  • In this paper, in the ventilation system of coal-fired power boilers can measure in real time the fan stall mechanism is all about. The fan stall guard system of boiler airing system of the class of 500MW capacity to protect fan. But because confidence is loosed and operation is influenced by frequent fault of fan stall guard system, confidence is improved by substituting DCS Logic for it.

Prediction of the Occurring Time of Stall for a Booster Fan in a Power Plant Combusting Low Quality Coal through Draft Loss (저품위탄 연소시 탈황용 승압송풍기 실속시점 예측)

  • Kim, Yeong-Gyun;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.8 no.4
    • /
    • pp.34-39
    • /
    • 2012
  • This study presents how low quality coal combustion affects the desulfurizer draft system by correlating of draft loss in a coal-fired thermal power plant and predicts the stall occurrence time of a booster fan. In case of low quality coal, a lot of coal is needed to generate equivalent output power, thereby the rating of increasing draft loss was faster than designed amount of coal. We surely confirmed that draft loss affects the specific energy of a booster fan strongly. On this basis, it is possible to predict the occurring time of stall for a booster fan from current operation specific energy to stall limit specific energy. This study suggests increasing speed of draft loss in each caloric value and the impact of specific energy at a booster fan, it expects to help safe operating in a thermal power plant.

  • PDF