• 제목/요약/키워드: tilt test

검색결과 248건 처리시간 0.026초

낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구 (A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle)

  • 김철주;강환국;김윤철
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

발레 바와 탄성밴드의 복합운동이 중년여성의 신체조성, 체력, 자세교정에 미치는 영향 (Effects of Ballet Bar and Elastic Band Exercise on Body Composition, Physical Fitness and Postural Correction in Middle-Aged Women)

  • 채지우;김현준
    • 대한통합의학회지
    • /
    • 제8권2호
    • /
    • pp.109-119
    • /
    • 2020
  • Purpose : The purpose of this study was to investigate the effects of a combined exercise program using a ballet bar and elastic bands on the body composition, physical strength, and postural correction of middle-aged women. Methods : The subjects were 28 middle-aged women with no ballet experience. They were divided into an experimental group (n=14; exercise group) and a control group (n=14; non-exercise group) through random sampling. The experimental group underwent an exercise program using a ballet bar and elastic bands for 50 minutes twice a week for 12 weeks, whereas the control group performed no exercise. The subjects in both group had their body composition, physical fitness, and postural angles measured before and after the intervention. A paired t-test was used to compare pre- and post-test values within each group, and a two-way repeated measures ANOVA was employed to compare pre- and post-test changes between the two groups. Results : Regarding body composition, statistically significant differences in BMI (p<.05), body fat percentage (p<.001), and muscle mass (p<.001) were observed between the two groups before and after the intervention. For physical fitness, the experimental group showed statistically significant increases in quick reflexes (p<.001), muscle endurance (p<.001), and muscle strength (p<.001). For postural correction, the experimental group exhibited statistically significant decreases in all variables: the head (p<.001), shoulder (p<.001), cervical tilt (p<.001), right-left pelvic tilt (p<.001), and anterior-posterior pelvic tilt (p<.001). Conclusion : A combined exercise program using a ballet bar and elastic bands had positive effects on the body composition, physical fitness, and postural correction of middle-aged women.

Comparing the Immediate Effectiveness of Lumbar Flexion and Extension Exercise With Regards to Pain, Range of Motion, Pelvic Tilt, and Functional Gait Ability in Patients With Lumbar Spinal Stenosis

  • Do, Hyun-ho;Chon, Seung-chul
    • 한국전문물리치료학회지
    • /
    • 제26권4호
    • /
    • pp.10-19
    • /
    • 2019
  • Background: In patients with lumbar spinal stenosis (LSS), lumbar flexion exercise (LFE) is considered a standard therapeutic exercise that widens the space between the spinal canal and intervertebral foramen. However, some researchers have reported that lumbar extension exercise (LEE) may improve lumbar pain and functional ability in patients with LSS. Although exercise intervention methods for patients with LSS have been widely applied in clinical settings, few studies have conducted comparative analysis of these exercise methods. Objects: This study aimed to compare the effects of LFE, LEE, and lumbar flexion combined with lumbar flexion-extension exercise (LFEE) on pain, range of motion (ROM), pelvic tilt angle, and functional gait ability in patients with LSS. Methods: A total of 30 patients with LSS, LFE (n1=10), LEE (n2=10), and LFEE (n3=10) were assigned to each of the three exercise groups. The numerical pain rating scale (NPRS), modified-modified schober test (MMST)-flexion, MMST-extension, pelvic tilt inclinometer, and 6-minute walking test (6MWT) were measured. Results: After the intervention, statistically significant differences were observed in the NPRS (p=.043), MMST-flexion (p<.001), MMST-extension (p<.001), and 6MWT (p=.005) between groups. According to the post hoc test, the NPRS was statistically significant difference between the LFEE and LEE groups (p=.034). The MMST-flexion was statistically significantly different between the LFE and LEE (p=.000), LFE and LFEE (p=.001), and LEE and LFEE (p=.001) groups. The MMST-extension was statistically significantly different between the LFE and LEE (p<.001), LFE and LFEE (p=.002), and LEE and LFEE (p=.008) groups. The 6MWT was statistically significantly different between the LFE and LFEE (p=.042) and the LEE and LFEE (p=.004) groups. Conclusion: This study suggested that LFEE was the most effective exercise for pain and functional gait ability in patients with LSS, LFE was the most effective exercise for lumbar flexion ROM, and LEE was the most effective exercise for lumbar extension ROM.

파킨슨병에서 기립저혈압과 인지 기능의 관계 (Orthostatic Hypotension and Cognitive Function in Parkinson's Disease)

  • 김수영;이주연;오응석;손은희;이애영
    • 대한신경과학회지
    • /
    • 제36권4호
    • /
    • pp.302-309
    • /
    • 2018
  • Background: Although orthostatic hypotension (OH) and cognitive impairment (CI) are common non- motor symptoms of Parkinson's disease (PD), the relationship between OH and CI remains to be clarified. This study was aimed to investigate the relationship between OH and CI in PD. Methods: We recruited 192 patients who were diagnosed as PD based on the UK Brain Bank diagnostic criteria. The Hoehn & Yahr stages were ranged I to III and patients underwent extensive clinical evaluation, including brain magnetic resonance imaging (MRI) for cerebral white matter hyperintensity (WMH), tilt table test, the Korean version of Montreal Cognitive Assessments and the Korean version of Mini-Mental Status Examination in one month from the first clinic visit. The participants were divided into two groups according to the presence of OH (OH+ vs. OH-) and cognitive function (cognitive normal, CN vs. CI), respectively. Results: Significant relationship between OH and cognitive function (p=0.04) was found in our patients. The patients with OH+ had higher risk of CI by 2.6 times than that of OH- patients. Maximum heart rate change during tilt table test was correlated with cognitive function and white matter changes, whereas blood pressure change during tilt table test showed no correlation with those parameters. Conclusions: There was significant relationship between OH and CI in PD. Therefore, PD patients with either symptom may need periodic evaluation and proper management for OH and cognitive functions.

머리 위치에 따른 사위도의 변화 (Head Posture-Induced Phoria Deviation)

  • 하은미;손정식;문병연;유동식
    • 한국안광학회지
    • /
    • 제15권2호
    • /
    • pp.155-160
    • /
    • 2010
  • 목적: 머리 위치에 따른 사위도 변화를 평가하고, 외안근의 불균형과 관련하여 좌 우안의 프리즘 량을 달리할 필요성을 확인하고자 하였다. 방법: 20~30세 남자 44명(88안), 여자 16명(32안)을 대상으로 차폐검사, 자각적 굴절검사, 사위검사 및 융합여력검사를 실시하였다. 머리기울임 검사, 얼굴돌림 검사에 따른 사위 변화량을 비교분석하기 위해 본 그래페를 이용하여 측정하였다. 결과: 머리기울임과 얼굴돌림에 따른 사위도 변화는 Morgan 표준의 수평사위 비정상군에서 유의한 차이를 보였고(p<0.05), 특히 근거리 Sheard 기준으로 수평사위 처방이 필요한 그룹에서 근거리 수평사위 변화량이 크게 나타났다(p<0.05). 수평사위 비정상군의 원거리 Sheard 기준으로 처방이 필요한 그룹과 필요하지 않은 그룹 모두 머리 위치에 따라 사위도 변화는 근거리일 경우 보다는 적었다. 결론: 수평사위 비정상군의 Sheard 기준 처방이 필요한 그룹에서 근거리 머리기울임, 얼굴돌림의 수평사위 변화량이 크게 나타났다. 따라서 근거리 사위에서 프리즘 처방을 해야 할 때 좌 우 외안근의 불균형의 존재를 확인하여 좌 우안에 프리즘량을 달리 처방할 필요성이 있는 것으로 본다.

스마트 무인기의 지상시험을 통한 비행제어 성능분석 (Assessment of Flight Control Performance based on the Ground Test Results of Smart UAV)

  • 강영신;박범진;유창선;김유신;구삼옥
    • 항공우주기술
    • /
    • 제9권1호
    • /
    • pp.1-8
    • /
    • 2010
  • 스마트무인기의 비행시험에 앞서 비행제어시스템을 포함한 전체 무인기 체계의 건전성을 검증하기위한 지상통합시험을 수행하였다. 지상통합시험은 비행체 인터페이스 시험, 비행체 HILS시험, 지상파워시험, 4자유도 치구시험, 안전줄 호버시험 순서로 진행되었으며, 각각의 시험을 통해 전체 무인기 시스템의 안전성을 입증하였다. 본 논문에서는 국내 최초로 개발된 틸트로터인 스마트무인기의 지상시험 절차와 각 시험에서 획득한 데이터 분석결과를 제시하였다. 지상시험 결과 비행제어시스템의 안전성이 충분히 입증되었으며, 비행시험이 수행가능하다고 판단되었다.

Assessment of cardiac function in syncopal children without organic causes

  • Kim, Heoungjin;Eun, Lucy Youngmin
    • Clinical and Experimental Pediatrics
    • /
    • 제64권11호
    • /
    • pp.582-587
    • /
    • 2021
  • Background: Syncope is a common problem in children and adolescents. However, a large proportion of syncope cases have no underlying cause. Purpose: This study aimed to identify the factors affecting the severity of syncope using tissue Doppler imaging (TDI). Methods: This retrospective study included 61 children and adolescents with syncope who underwent echocardiography. The head-up-tilt test (HUT) was performed when there was a more severe syncopal event. We compared the echocardiographic findings between the execute HUT and nonexecute HUT, negative HUT result and positive HUT result, and normal electrocardiogram (ECG) and abnormal ECG groups. Data were analyzed using an unpaired t test post hoc analysis. Results: In the execute and nonexecute HUT groups, the odds ratios were 0.55 for medial E/E' (P=0.040) and 0.64 for lateral E/E' (P=0.049). Comparison of the results of the decreased, normal, and increased groups for lateral E/E' revealed a significant difference in the execution HUT and nonexecute HUT groups (overall, P=0.004; decreased vs. increased, P=0.003; normal vs. increased, P=0.050). Conclusion: Medial E/E' and lateral E/E' were decreased in patients with severe syncopal events. These findings suggest that the presence of left ventricular diastolic deterioration may cause hypoperfusion even in the absence of organic causes and, consequently, increase syncope severity and frequency. The TDI measured by echocardiography can be used as an index to predict syncope recurrence and/or severity.

지능형 실내 위치전환 시스템의 동기제어 (Synchronizing control of intelligent indoor lift system)

  • 양호남;양현석;최용제;홍만복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.330-333
    • /
    • 2003
  • In this thesis. the application of the synchronizing control of the intelligent indoor lift system is showed. The separate axes of the indoor lift system are driven independently. PID controller, synchronous flexible logic compensating method and tilt sensor are applied to enhance the performance of the intelligent indoor lift system. the tilt sensor senses the horizontal error of the whole system. PID controller and synchronous flexible logic are used to compensate the synchronous errors of both the separate axes and whole system to be zero. Namely, using not the hardware coupling but the software algorithm. the indoor life system is operated without the error. Before applying the real system, the simulation using matlab testifies the possibility of the lift system. And the realization of the system is demonstrated with two DC servo motors. In the experiment test, flexible logic to compensate the synchronous error is chosen by the comparative method. the indoor lift system has to be considered the loading factor as the disturbance. Because the intelligent indoor lift system is developed to support the patients who don't change for themselves to move. finally, the system which considers the weight of the patient as the disturbance can carry the patients safely without synchronous and position error.

  • PDF

Head-up Tilt상태에서 심박변동과 자율신경활동 균형의 관계에 관한 연구 (A Study on Relationship between Heart Rate Variabilities and Autonomic Balance during Head-up Tilt)

  • 정기삼;신건수
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.37-44
    • /
    • 1997
  • In this paper, the power spectral analysis of heart rate variability(HRV) was performed to evaluate effects of orthostatic stress with head-up tiIt on autonomic nervous system(ANS) for 25 healthy male subjects(age : 24 $\pm$ 5 yr.) and a new method was proposed to assess the autonomic balance. The ECG and respiration signals were recorded at tiIt angles of $0^{\circ}$, $45^{\circ}$, $90^{\circ}$and $0^{\circ}$ successively for 10 minutes per each stage under the condition of frequency controlled respiration(0.25Hz). Heat rate(HR) gradually increased ils the angle increased Similarly, according to the increment of angle, normalized low frequency component(0.05-0.15Hz) gradually increased, whereas normalized high frequency component (0.20-0.30Hz) was reduce4 From these results it is speculated that orthostatic stress head-up tiLt, results in the prevalence of sympathetic tone in autonomic balance with the increment of sympathetic tone and the decrement of parasympathetic tone, which seems to meanthat autonomic nervous system plays a major role in compensating for disturbances of cardiovascular system due to it.

  • PDF

기울기 및 광센서를 이용한 자동차 헤드라이트 자동조절시스템 (Automotive Headlight Control System Using Tilt and Photo Sensors)

  • 김태웅
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.14-21
    • /
    • 2004
  • 본 논문에서는 평지, 오르막 및 내리막에서 야간 운전할 때에 생기는 눈부심에 대해 헤드라이트를 자동 조절하여 운전자가 안전하게 운전을 할 수 있는 알고리즘을 제안하였다. 먼저 광센서를 이용해 전방에 차량이 접근하는지의 유무를 판단하고 기울기센서로써 차량의 기울어진 정도를 계속적으로 판단하도록 하였다. 이러한 정보를 이용하여 헤드라이트를 조절하는 서보모터를 제어함으로써 현 운행환경조건에 맞도록 조절할 수 있도록 하였다. 본 논문에서 제안한 헤드라이트 자동조절시스템은 평지 및 경사로에서 실제로 측정한 조도량에 대한 데이터를 바탕으로 하여 제작되었고, 테스트 모델에 의해 얻은 실험결과를 통해 환경과 조건에 따라 제대로 작동하고 효과가 있음을 확인하였고, 따라서 본 알고리즘의 유효성을 증명하였다.