Fire Resistance of High Strength Concrete Columns with Tie Spacing (띠철근 간격에 따른 고강도 콘크리트 기둥의 내화 성능)

  • Park, Chan-Kyu;Lee, Seung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.393-396
    • /
    • 2008
  • This paper presents the experimental results on the fire performance of high strength concrete(HSC) column made with different tie spacing. Three HSC columns measuring 305${\times}$305mm in cross section were prepared to evaluate the effect of tie spacing with 150, 210, 300mm, respectively. Compressive strength was 69MPa at test. As a result, the fire performance of HSC columns was greatly influenced by tie spacing. The fire resistance increases with decreasing the tie spacing.

  • PDF

Confinement Effects of Reinforced Concrete Tied Columns (철근콘크리트 띠철근 기둥의 구속효과)

  • 왕성근;한범석;이희수;신성우;반병열
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.29-34
    • /
    • 2001
  • An experimental study was conducted to investigate the effectiveness of transverse reinforcement in reinforced concrete tied columns subjected to monotonically increasing axial compression. Eighteen large-scale columns(260$\times$260$\times$120mm) were fabricated to simulate similarly an actual structural members size. Effects of main variables such as the concrete compressive strength, the tie configuration, the transverse reinforcement ratio, the tie spacing, and the spatting of the concrete cover were studied in this research program.

  • PDF

Behavior of Rectangular Hollow Bridge Compression Section by Detail of Cross-tie (보강띠철근의 상세에 따른 중공 사각형 교각 압축부의 파괴 거동)

  • Lee, Jae Hoon;Kim, Ho Young;Kwahk, Im Jong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.1
    • /
    • pp.21-29
    • /
    • 2017
  • Purpose of this study is to investigate structural behavior of the rectangular hollow column with various transverse reinforcement details. Experimental variables are diameter, arrangement details and lateral spacing of cross tie. A total of 66 column specimens have been prepared and tested under axial compressive load. Test results showed that behaviors of column specimens were different depending on the cross tie details. Specimens with cross tie wrapping longitudinal steel and transverse steel have greater strength and ductility than specimens with cross tie wrapping the longitudinal steel.

Influence of Concrete Strength and Lateral Ties on Behavior of High-Strength Concrete Columns (고강도 콘크리트 기둥의 거동에 미치는 콘크리트 강도와 띠철근의 영향)

  • Lee, Young-Ho;Chung, Heon-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.2
    • /
    • pp.245-253
    • /
    • 2002
  • This study was focused on the effect of concrete strength and lateral ties of concrete columns using high-strength concrete. Thirty-six concrete columns with 20cm square cross-section were tested. Experimental parameters included the concrete strength, the distribution of longitudinal bars and the volumetric ratio, yield strength, spacing of lateral ties. From the experiments, we found that: 1) the increasing rate of the strength and ductility of concrete columns caused by confinement of lateral ties was decreasing, as the concrete strength increased. 2) The high volumetric ratio and the reduction of tie spacing had a tendency to enhance the strength and improve the ductility. 3) The high-strength concrete columns required high volumetric ratio of lateral ties to maintain the proper strength and ductility. It was observed that the current AIK design code to specify the maximum tie spacing of high-strength concrete columns led to the poor strength and ductility for seismic design.

Bow-tie Mode Lasing in a Grooved Rectangular Semiconductor Microcavity

  • Moon, Hee-Jong;Hyun, Kyung-Sook
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.162-165
    • /
    • 2012
  • Bow-tie modes were proposed in a grooved rectangular resonator and their lasing characteristics were investigated in semiconductor microcavities. The observed spacing between two adjacent lasing peaks from the grooved cavity was reduced compared to that of 4-bounce whispering gallery modes (WGMs) from the same-sized simple rectangular cavity due to increased round-trip path length of the bow-tie modes. The lasing spectra of bow-tie modes obtained from two adjacent corners showed highly correlated patterns while those of 4-bounce WGMs did not.

Design of Compact Log-Periodic Half-Bow-tie Dipole Array Antenna for UWB Band (UWB 대역 소형 대수-주기 반-보우타이 다이폴 배열 안테나 설계)

  • Yeo, Junho;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.81-82
    • /
    • 2016
  • In this paper, a design method for a compact log-periodic half-bow-tie dipole array antenna for an operation in UWB band is studied. The proposed antenna is miniaturized by using half-bow-tie shaped dipole elements instead of strip-type dipole elements, which are commonly used in general log-periodic dipole array antenna, and by reducing the element spacing. The effects of the flare angle of the half-bow-tie elements and the element spacing on input reflection coefficient and realized gain characteristics of the proposed log-periodic antenna are analyzed. The optimized antenna is designed on FR4 substrate, and it operates in the frequency band of 3.05-13.96 GHz for a VSWR < 2, which assures the operation in the UWB band.

  • PDF

Influence of Concrete Strength and Lateral Ties on Behavior of High-Strength Concrete Columns Subjected to Eccentric Compressive Load (편심 압축력을 받는 고강도 콘크리트 기둥의 거동에 미치는 띠철근 및 콘크리트 강도의 영향)

  • Lee, Young Ho;Chung, Heon Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.95-104
    • /
    • 2007
  • This study was focused on the effect of concrete strength and lateral ties of concrete columns subjected to eccentric compressive loads. The twenty-four concrete columns with $200mm{\times}200mm$ square cross-section were tested. The main variables were concrete strength, spacing and configuration of lateral ties, and eccentricity ratios. From the experiment, the followings were investigated ; 1) In all cases, it was observed that the increase of concrete compressive strength led to the decrease of ductility. Also, as the eccentricity ratios increased, the effect of ductility enhancement by lateral ties decreased. 2) As the ties spacing decreased from 100mm to 30mm, the magnitude of axial load acting on the concrete column showed an enhancement of 1.1~1.2 times and the descending curve after a peak moment presented a smooth decline. 3) The high-strength concrete columns required a design of lateral ties to increase the volumetric ratios and density of tie spacing to sustain a proper strength and ductility. Accordingly, regardless of concrete strength, the current AIK design code to specify the maximum tie spacing of concrete columns was proven to lead to the poor strength and ductility for seismic design. Therefore, it is necessary to develop a new seismic design code that connects volumetric ratios and tie spacing of concrete columns with concrete strength.

Development of Corner-Supported Auto Climbing Formwork System (강합성코어벽을 활용한 코너지지형 거푸집시스템 개발)

  • Hong, Geon-ho;Shim, Woo-Kyung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.7
    • /
    • pp.171-178
    • /
    • 2019
  • Auto Climbing Formwork System (ACS) for construction of high-rise building is a construction method for automatically lifting the formwork system supported by the anchor on the pre-constructed concrete wall. It has excellent construction speed and quality, but it has the possibility of structural failure depending on the quality of concrete and also has low economical efficiency due to the use of foreign technology. In order to overcome these problems, this study conducted an optimum design for the development of a new concept of Corner Supported Auto Climbing System (CS-ACS) in conjunction with the development of corner steel-reinforced concrete core wall system. For the design the formwork system, the basic module and structural member compositions were planned, and the structural analysis program was used to analyze the optimum member's cross section and spacing. As a result, the horizontal displacement and the stress of the horizontal members were influenced by the spacing more than the cross-section of the member. On the other hand, vertical members did not affect the displacement and stress of the formwork system. The form tie was very effective in controlling the displacement when adjusting the spacing of the horizontal members, but when the spacing of the form tie is more than 1,500mm, it is analyzed that form tie is yielding in basic module. When the span of the formwork system is more than 30m, it is analyzed that the basic module needs to be changed because of the increase of overall displacement.

Miniaturized LPDA Antenna for Portable Direction Finding Applications

  • Yeo, Jun-Ho;Lee, Jong-Ig
    • ETRI Journal
    • /
    • v.34 no.1
    • /
    • pp.118-121
    • /
    • 2012
  • In this letter, a miniaturized log-periodic dipole array (LPDA) antenna operating from 1 GHz to 6 GHz is proposed for portable direction finding applications. To reduce the lateral size of an LPDA antenna, bow-tie elements and a top-loading technique are utilized and spacing factor is decreased to reduce the spacing between the LPDA elements. The proposed miniaturized LPDA antenna has the measured gain and front-to-back ratio ranging from 1.2 dBi to 3 dBi and from 7 dB to 22 dB, respectively.

Pullout Test of Headed Reinforcement 2: Deep Embedment

  • Choi, Dong Uk;Shin, InYong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1091-1096
    • /
    • 2003
  • Pullout tests of single headed bars using plain concrete blocks indicate that the embedment depth of $10d_b$ is in general required for the headed bars to develop pullout strength equivalent to 125% of bar yield strength. In this experimental study, test results of multiple headed bars installed in reinforced concrete column sections are presented. Test variables included embedment depth, column main reinforcement ratio, and spacing of column ties. 2D29 bars were pulled out at one time from normal strength concrete. Test results indicated that the embedment depths, column tie spacings, and column main reinforcement ratios all influenced the pullout strengths of the headed bars. When the embedment depth was not sufficient, narrow tie spacings especially resulted in increased pullout strengths of the headed bars. Test results also indicated that the embedment depth of 15㏈ was sufficient for the closely spaced two headed bars (head-to-head spacing =$6d_b$) to develop pullout strength equivalent to 125% of the bar yield strength.

  • PDF