• Title/Summary/Keyword: thyroid imaging

Search Result 159, Processing Time 0.032 seconds

Should We Recommend Ultrasonography for an Incidental Thyroid Nodule on Additional Cervicothoracic Sagittal T2-Weighted Image of Lumbar Spine MRI?

  • Cho, Hee Woo;Park, Jin-Oh;Lee, Young Han;Chung, Soo Yoon;Suh, Jin-Suck
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.4
    • /
    • pp.224-230
    • /
    • 2015
  • Purpose: To determine whether we should recommend ultrasonography (US) for an incidental thyroid nodule identified by additional cervicothoracic sagittal T2-weighted image (C-T sag T2WI) of lumbar spine magnetic resonance imaging (MRI). Materials and Methods: A retrospective study of 61 patients who underwent both lumbar spine MRI and thyroid US between December 2011 and April 2015 was conducted. For all US-found thyroid nodules > 1 cm, investigators evaluated whether there was any correlation between thyroid nodule detectability by C-T sag T2WI and US features such as echogenicity, composition, or suspicion of malignancy. Results: Solid hypoechoic (2/4; 50%) or mixed echoic nodules (4/8; 50%) appeared to be found relatively more easily by C-T sag T2WI than more benign-looking solid isoechoic (1/4; 25%) or spongiform nodules (0/6; 0%). Among six nodules with ultrasonographic suspicion for malignancy, only one nodule was detected by C-T sag T2WI. Conclusion: If an incidental thyroid nodule is seen by C-T sag T2WI, it would be better to recommend thyroid US for identifying malignancy.

Diagnostic Performance of the Modified Korean Thyroid Imaging Reporting and Data System for Thyroid Malignancy: A Multicenter Validation Study

  • Sae Rom Chung;Hye Shin Ahn;Young Jun Choi;Ji Ye Lee;Roh-Eul Yoo;Yoo Jin Lee;Jee Young Kim;Jin Yong Sung;Ji-hoon Kim;Jung Hwan Baek
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1579-1586
    • /
    • 2021
  • Objective: To evaluate the diagnostic performance of the modified Korean Thyroid Imaging Reporting and Data System (K-TIRADS), and compare it with the 2016 version of K-TIRADS using the Thyroid Imaging Network of Korea. Materials and Methods: Between June and September 2015, 5708 thyroid nodules (≥ 1.0 cm) from 5081 consecutive patients who had undergone thyroid ultrasonography at 26 institutions were retrospectively evaluated. We used a biopsy size threshold of 2 cm for K-TIRADS 3 and 1 cm for K-TIRADS 4 (modified K-TIRADS 1) or 1.5 cm for K-TIRADS 4 (modified K-TIRADS 3). The modified K-TIRADS 2 subcategorized the K-TIRADS 4 into 4A and 4B, and the cutoff sizes for the biopsies were defined as 1 cm for K-TIRADS 4B and 1.5 cm for K-TIRADS 4A. The diagnostic performance and the rate of unnecessary biopsies of the modified K-TIRADS for detecting malignancy were compared with those of the 2016 K-TIRAD, which were stratified by nodule size (with a threshold of 2 cm). Results: A total of 1111 malignant nodules and 4597 benign nodules were included. The sensitivity, specificity, and unnecessary biopsy rate of the benign nodules were 94.9%, 24.4%, and 60.9% for the 2016 K-TIRADS; 91.0%, 39.7%, and 48.6% for the modified K-TIRADS 1; 84.9%, 45.9%, and 43.5% for the modified K-TIRADS 2; and 76.1%, 50.2%, and 40.1% for the modified K-TIRADS 3. For small nodules (1-2 cm), the diagnostic sensitivity of the modified K-TIRADS decreased by 5.2-25.6% and the rate of unnecessary biopsies reduced by 19.2-32.8% compared with those of the 2016 K-TIRADS (p < 0.001). For large nodules (> 2 cm), the modified K-TIRADSs maintained a very high sensitivity for detecting malignancy (98%). Conclusion: The modified K-TIRADSs significantly reduced the rate of unnecessary biopsies for small (1-2 cm) nodules while maintaining a very high sensitivity for malignancy for large (> 2 cm) nodules.

Management of Recurrent Thyroid Carcinoma with Negative Diagnostic Radioiodine Whole-Body Scan (진단적 방사성옥소 전신스캔이 음성인 갑상선 재발암의 진료)

  • Chung, June-Key
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.117-124
    • /
    • 2001
  • Serum thyroglobulin measurement and I-131 whole-body scintigraphy (WBS) are well-established methods for the detection of recurrence in the follow-up of patients with thyroid carcinoma. However, inconsistent results are observed frequently, and these two methods are not always able to detect recurrence. In some patients, serum thyroglobulin level is elevated but the WBS is negative, because the recurrent tumor is too small and below the sensitivity of the diagnostic scan, or there is a dissociation between thyroglobulin synthesis and the iodine frapping mechanism. In such cases, various nuclear imaging methods including Tl-201 Tc-99m-sestamibi, and F-18-FDG PET can be used besides anatomical imaging methods. Among them, FDG PET localizes recurrent lesions in WBS-negative thyroid carcinoma with high accuracy. Several studies have suggested that empirical high-dose I-131 therapy resulted in a high rate of visualization in post-therapy scans with evidence of subsequent improvement. An important question is when to operate on patients with recurrent tumor. We believe that surgical removal is the best means of treatment for patients with localized persistent tumor, despite the high-dose I-131 therapy. with tumor in thyroid remnant, and with isolated recurrence in the lymph node, lung or bone. In addition, we recommend palliative resection of locally unresectable mass with subsequent treatment with high-dose I-131 therapy. Before I-131 therapy, the evaluation of sodium-iodide symporter expression in thyroid carcinoma can predict iodine uptake. Retinoic acid is known to induce redifferentiation, and to enhance I-131 uptake in thyroid carcinoma. Retinoic acid therapy may represent an alternative approach before high-dose I-131 therapy.

  • PDF

Papillary Thyroid Microcarcinoma Presenting as Neck Masses (경부 종물로 발현된 유두 미세 갑상선암)

  • Kim Young-Mo;Park Sun-Ki;Shin Jun-Sun;Jeon Yong-Sun;Han Chang-Jun;Cho Jung-Il
    • Korean Journal of Head & Neck Oncology
    • /
    • v.18 no.1
    • /
    • pp.65-70
    • /
    • 2002
  • Background and Objectives: Recently the tenn 'papillary microcarcinoma' has been proposed to designate carcinoma of 10 mm or less in diameter. In some cases, cervical lymph node metastasis preceding the occurrence of the primary tumor may be the first and sole manifestation of the disease. The objective of this study is to assess the clinical features of cervical metastasis in papillary microcarcinoma of thyroid glands. Materials and Methods: 9 cases with papillary microcarcinoma with neck metastasis were analyzed retrospectively. 5 cases are men and 4 are women. All patients complained of painless, movable neck mass. The symptom had been present from 1 month to 36 months. We reviewed clinical history, imaging studies, the results of fine needle aspiration, the surgical method, the pathologic results. Results: In 9 cases, no abnormalities of the thyroid gland were shown by imaging studies and thyroid scan. 3 cases were diagnosed by fine needle aspiration cytology. the others were not. Total thyroidectomy and neck dissection were performed in 9 cases and then pathology reports showed 2 case of multiple, 2 case of contralateral single and 5 cases of unilateral single thyroid microcarcinoma. They have no recurrence during follow-up period. Conclusions: Cervical metastasis from papillary microcarcinoma is variable clinical manifestation. The diagnosis of cervical metastasis from papillary microcarcinoma should be considered in patient with neck mass. We recommend total thyroidectomy with neck dissection and postoperative radioactive iodine ablation therapy in neck metastasis from papillary thyroid microcarcinoma.

Thyroid Hemiagenesis Associated with Papillary Thyroid Carcinoma : Report of a Case and Review of the Literature (갑상선 편측형성부전에 동반된 유두 갑상선암 1예)

  • Lee, Yong-Sang;Yun, Ji-Sup;Jeong, Jong-Ju;Nam, Kee-Hyun;Chung, Woong-Youn;Park, Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.2
    • /
    • pp.161-164
    • /
    • 2007
  • Thyroid hemiagenesis is a rare anomaly, which is the result of failure of embryologic development of a lobe of thyroid gland. It is more frequently found in the left lobe and in female patients. We, herein, report an extremely rare case of thyroid hemiagenesis associated with papillary thyroid carcinoma. A 69-year-old female presented with an incidentally discovered thyroid nodule in the right thyroid during a routine medical check-up. Ultrasonography(US) and computed tomography(CT) disclosed $0.7{\times}0.5cm\;and\;2.8{\times}2.2cm$ sized nodules in the right thyroid. The left thyroid, however, was not seen in the imaging studies of US and CT. Fine-needle aspiration of the small and large nodules showed papillary thyroid carcinoma and adenomatous hyperplasia, respectively. The patient underwent a right total thyroidectomy with central compartment node dissection. The operative findings and histologic examination confirmed the absence of the left thyroid associated with papillary thyroid carcinoma and ademonatous hyperplasia of the right thyroid.

Scientific Publications on Thyroid Ultrasound between 2001 and 2020: Differences in Research Characteristics by Disciplines

  • Won Chul Shin;Chae Woon Lee;Jiyeon Ha;Kyoung Ja Lim;Young Lan Seo;Eun Joo Yun;Dae Young Yoon
    • Korean Journal of Radiology
    • /
    • v.23 no.8
    • /
    • pp.835-845
    • /
    • 2022
  • Objective: To analyze the characteristics and trends of scientific publications on thyroid ultrasound (US) from 2001 to 2020, specifically examining the differences among disciplines. Materials and Methods: The MEDLINE database was searched for scientific articles on thyroid US published between 2001 and 2020 using the PubMed online service. The evaluated parameters included year of publication, type of document, topic, funding, first author's specialty, journal name, subject category, impact factor, and quartile ranking of the publishing journal, country, and language. Relationships between the first author's specialty (radiology, internal medicine, surgery, otorhinolaryngology, and miscellaneous) and other parameters were analyzed. Results: A total of 2917 thyroid US publications were published between 2001 and 2020, which followed an exponential growth pattern, with an annual growth rate of 11.6%. Radiology produced the most publications (n = 1290, 44.2%), followed by internal medicine (n = 716, 24.5%), surgery (n = 409, 14.0%), and otorhinolaryngology (n = 171, 5.9%). Otorhinolaryngology and internal medicine published significantly more case reports than radiology (p < 0.001, each). Radiology published a significantly higher proportion of publications on imaging diagnosis (p < 0.001 for all) and a significantly lower proportion of publications on biopsy (p < 0.001 for all) than the other disciplines. Publications produced by radiology authors were less frequently published in Q1 journals than those from other disciplines (p < 0.005 for internal medicine and miscellaneous disciplines and < 0.01 for surgery and otorhinolaryngology). China contributed the greatest number of publications (n = 622, 21.3%), followed by South Korea (n = 478, 16.4%) and the United States (n = 468, 16.0%). Conclusion: Radiology produced the most publications for thyroid US than any other discipline. Radiology authors published more notably on imaging diagnosis compared to other topics and in journals with lower impact factors compared to authors in other disciplines.

Dual Lingual Thyroid Mimicking Mono-ectopic Thyroid in the Anterior View of Tc-99m Sodium Pertechnetate Thyroid Scan (전면 영상에서 하나로 오인된 두개의 설갑상전종)

  • Chong, A-Ri;Jeong, Shin-Young;Kwon, Seong-Young;Seo, Young-Soon;Ha, Jung-Min;Oh, Jong-Ryool;Bom, Hee-Seung;Song, Ho-Chun;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.485-487
    • /
    • 2008
  • Ectopic thyroid is not common disease and double ectopic thyroid is rare. Until January of 2008, dual ectopic thyroid has been reported only 23 cases in international literatures. Tc-99m sodium pertechnetate scan is playing an important role in the diagnosis of ectopic thyroid. In most of the cases, dual lingual thyroid tissues could be detected as two radiotracer uptake foci. We report a case of dual lingual thyroid mimicking mono-lingual thyroid in the anterior view of thyroid scan. Lateral view helped in this case to detect the dual lingual thyroid. With lateral view, the anatomical position and relationship could be examined in more detail.

A New Radiation-Shielding Device for Restraining Veterinary Patients

  • Songyi Kim;Minju Lee;Miju Oh;Yooyoung Lee;Jiyoung Ban;Jiwoon Park;Sojin Kim;Uhjin Kim;Jaepung Han;Dongwoo Chang
    • Journal of Veterinary Clinics
    • /
    • v.40 no.6
    • /
    • pp.429-437
    • /
    • 2023
  • In veterinary medicine, most radiographic images are obtained by restraining patients, inevitably exposing the restrainer to secondary scattered radiation. Radiation exposure can result in stochastic reactions such as cancer and genetic effects, as well as deterministic reactions such as skin burns, cataracts, and bone marrow suppression. Radiation-shielding equipment, including aprons, thyroid shields, eyewear, and gloves, can reduce radiation exposure. However, the risk of radiation exposure to the upper arms, face, and back remains, and lead aprons and thyroid shields are heavy, restricting movement. We designed a new radiation-shielding system and compared its shielding ability with those of conventional radiation-shielding systems. We hypothesized that the new shielding system would have a wider radiation-shielding range and similar shielding ability. The radiation exposure dose differed significantly between the conventional and new shielding systems in the forehead, chin, and bilateral upper arm areas (p < 0.001). When both systems were used together, the radiation-shielding ability was better than when only one system was used at all anatomical locations (p < 0.01). This study suggests that the new radiation-shielding system is essential and convenient for veterinary radiation workers because it is a step closer to radiation safety in veterinary radiography.

The absorbed doses from each exposure program of the Orthopos$\textregistered$ panoramic machine (Orthopos$\textregistered$ 파노라마방사선촬영기의 각종 프로그램에 따른 흡수선량)

  • Choi Soon-Chul;Lee Sul-Mi
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.215-219
    • /
    • 2001
  • Purpose: The objective of this study was to estimate the radiation absorbed doses in certain critical organs in the head and neck region with 16 imaging programs available on the Orthopos/sup (R)/ panoramic machine. Materials and Methods: A Rando phantom and LiF TLD chips were used for dosimetry. The absorbed doses were measured at the thyroid gland, the submandibular gland, the parotid gland, the mouth floor. the maxillary sinus, the brain, the mandibular body, the mandibular ramus. the 2nd cervical spine and the skin over TMJ area. Results : The overall absorbed doses with imaging programs available on the Orthopos/sup (R)/ panoramic machine were much less than that of standard program (program 1) except program 8, 11, and 16. Generally, the absorbed doses to the bone marrow of the mandibular ramus and the parotid gland were high, but the absorbed doses to the bone marrow in the mandibular body, brain, maxillary sinus, and, especially, the thyroid gland were very low. Conclusion : The modified imaging programs available on the Orthopos/sup (R)/ panoramic machine can be effectively used in aspect of radiation protection.

  • PDF

Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria

  • Younghee Yim;Dong Gyu Na;Eun Ju Ha;Jung Hwan Baek;Jin Yong Sung;Ji-hoon Kim;Won-Jin Moon
    • Korean Journal of Radiology
    • /
    • v.21 no.1
    • /
    • pp.108-116
    • /
    • 2020
  • Objective: To investigate the concordance of three international guidelines: the Korean Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by ultrasonography (US) and the diagnostic performance of simulated size criteria for malignant biopsies. Materials and Methods: A total of 2586 thyroid nodules (≥ 1 cm) were collected from two multicenter study datasets. The classifications of the thyroid nodules were based on three different guidelines according to US categories for malignancy risk, and the concordance rate between the different guidelines was calculated for the classified nodules. In addition, the diagnostic performance of criteria related to four different simulated biopsy sizes was evaluated. Results: The concordance rate of nodules classified as high- or intermediate-suspicion was high (84.1-100%), but low-suspicion or mildly-suspicious nodules exhibited relatively low concordance (63.8-83.8%) between the three guidelines. The differences in sensitivity, specificity, and accuracy between the guidelines were 0.7-19.8%, 0-40.9%, and 0.1-30.5%, respectively, when the original biopsy criteria were applied. The differences decreased to 0-5.9%, 0-10.9%, and 0.1-8.2%, respectively, when simulated, similar biopsy size criteria were applied. The unnecessary biopsy rate calculated with the original criteria (0-33.8%), decreased with the simulated biopsy size criteria (0-8.7%). Conclusion: We found a high concordance between the three guidelines for high- or intermediate-suspicion nodules, and the diagnostic performance of the biopsy criteria was approximately equivalent for each simulated size criterion. The difference in diagnostic performance between the three guidelines is mostly influenced by the various size thresholds for biopsies.