• 제목/요약/키워드: thromboembolic coils

검색결과 6건 처리시간 0.017초

Types of Thromboembolic Complications in Coil Embolization for Intracerebral Aneurysms and Management

  • Kim, Hong-Ki;Hwang, Sung-Kyun;Kim, Sung-Hak
    • Journal of Korean Neurosurgical Society
    • /
    • 제46권3호
    • /
    • pp.226-231
    • /
    • 2009
  • Objective : We describe our clinical experiences and outcomes in patients who had thromboembolic complications occurring during endovascular treatment of intracerebral aneurysms with a review of the literature. The types of thromboembolic complications were divided and the treatment modalities for each type were described. Methods : Between August 2004 and March 2009 we performed endovascular embolization with Guglielmi detachable coils for 173 patients with 189 cerebral aneurysms, including ruptured and unruptured aneurysms at our hospital. Sixty-eight patients were males and 105 patients were females. The age of patients ranged from 22-82 years (average, 58.8 years). We retrospectively evaluated this group with regard to complication rates and outcomes. The types of thromboembolic complications were classified into the following three categories: mechanical obstruction, distal embolic stroke, and stent-induced complications, which corresponded to types I, II, and III, respectively. A comparison of the clinical results was made for each type of complication. Results : Only eight patients had a thromboembolic complication during or after a procedure (4.6%). Of the eight patients, two had a mechanical obstruction as the causative factor; the other three patients had distal embolic stroke as the causative factor. The remaining three patients had stent-induced complications. In cases of mechanical obstruction, recanalization occurred due to the use of intra-arterial thrombolytic agents in one of two patients. Nevertheless, a poor prognosis was seen. In the cases of stent-induced complications, in one of three patients in whom a thrombus developed following stent insertion, a middle cerebral artery territory infarct developed with a poor prognosis despite the use of wiring and an intra-arterial thrombolytic agent. In the cases of distal embolic stroke, all three patients achieved good results following the use of antiplatelet agents. Conclusion : Treatment for thromboemboic complications due to mechanical obstruction and stent-induced complications include antiplatelet and intra-arterial thrombolytic agents; however, this cannot guarantee a sufficient extent of effectiveness. Therefore, active treatments, such as balloon angioplasty, stent insertion, and clot extraction, are helpful.

Thromboembolic Events Associated with Electrolytic Detachment of Guglielmi Detachable Coils and Target Coils : Comparison with Use of Diffusion-Weighted MR Imaging

  • Kim, Myeong Jin;Lim, Yong Cheol;Oh, Se-Yang;Kim, Byung Moon;Kim, Bum-Soo;Shin, Yong Sam
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권1호
    • /
    • pp.19-24
    • /
    • 2013
  • Objective : The purpose of this study was to retrospectively evaluate and compare the incidence of diffusion-weighted image (DWI) lesions between the Guglielmi detachable coil (GDC) and the Target coil for treating unruptured intracranial aneurysm. Methods : From 2010 to 2011, consecutive 222 patients with an intracranial aneurysm underwent coil embolization. Inclusion criterias were : 1) unruptured intracranial aneurysm, 2) one or more GDC or Target coils used with or without other coils, 3) DWI examination within 24 hours after coiling, and 4) coiling performed without a balloon or stent. Results : Ninety patients (92 cases) met the inclusion criteria. DWI lesions were detected in 55 (61.1%) of 90 patients. In the GDC group (n=44), DWI lesions were detected in 31 (70.5%). The average number of DWI lesions was $5.0{\pm}8.7$ (mean${\pm}$SD; range, 1-40) in aneurysm-related territory. In the Target coil group (n=48), DWI lesions were detected in 24 (50.0%). The number of DWI lesion was $2.1{\pm}5.4$ (range, 1-32) in aneurysm-related territory. There was no significant correlation between a number of coils and DWI lesions. No significant differences were also observed in the number of DWI lesions in each group. Conclusion : The GDC and Target coils, which have an electrolytic detachable system, showed no differences in the incidence of DWI lesion.

Angiographic Follow-up Result of Cerebral Aneurysms Treated with Coils Covered with Polyglycolic-Polylactic Acid Copolymer

  • Kim, In-Cheol;Chun, Young-Il;Park, Cheol-Wan;Park, Chan-Woo;Lee, Uhn
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권4호
    • /
    • pp.286-291
    • /
    • 2006
  • Objective : We evaluate the effect of the copolymer-coated coils on immediate occlusion of the aneurysm, preventing rupture, and decreasing compaction or re-growth. Methods : Thirty-five aneurysms treated between September 2003 and December 2004 using Matrix detachable coil were reviewed. Study population consisted of 12 men and 23 women ranging in age from 34 to 75 years[mean, 55.1 years]. Twenty-two aneurysms were ruptured and 23 aneurysms were located in the anterior circulation. Follow-up angiography was obtained in 16 patients after 6 months from the procedure. Results : Initial complete occlusion was achieved in 17 aneurysms[48.6%], and the others remained as a residual neck in 8 aneurysms[22.8%] and residual sac in 10 aneurysms[28.6%]. Among these incompletely occluded aneurysms, 7 aneurysms were performed follow-up angiography. And 6 of them converted into complete occlusion. In the other hands, among 17 aneurysms achieved complete occlusion initially, 9 aneurysms were performed follow-up angiography. Recurrence due to coil compaction occurred in one aneurysm and the others maintained complete occlusion. There was one mortality case due to thromboembolic complication. Conclusion : In spite of difficulty in achieving complete occlusion with Matrix coil system, there is no rupture or re-rupture during follow-up period. Follow-up angiography shows many conversions of residual sac into complete occlusion. Embolization using Matrix coil system is safe and effective, but the effects of PGLA copolymer need further investigation.

Delayed Monocular Blindness after Coil Embolization of Large Paraclinoid Aneurysm

  • Han, Jae-Sung;Kim, Tae-Hun;Oh, Jae-Sang;Yoon, Seok-Mann
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • 제20권4호
    • /
    • pp.241-247
    • /
    • 2018
  • Treatment of paraclinoid aneurysms weather by surgery, or endovascular embolization has a risk of visual loss due to optic neuropathy, or diplopia due to cranial nerve palsies. Visual complications occur immediately after the clipping, whereas they can occur variable time after endovascular coiling. Recently, endovascular coiling for paraclinoid aneurysm is regarded as a safe and feasible treatment. But it still has risks of acute thromboembolic complication, or cranial nerve palsies. A 45-year-old woman was referred from local hospital to our hospital due to ruptured large ICA dorsal wall aneurysm. A total of 12 coils (195 cm) were used for obliteration of aneurysm. Postoperative diffusion weighted image showed no abnormal signal intensity lesion and magnetic resonance angiography demonstrated no sign of vasospasm, or vessel narrowing. But, she complained visual problem 23 days after coil embolization. Ophthalmologist confirmed the left optic disc atrophy on fundoscopy. Although steroid was started, but monocular blindness did not recover completely. The endovascular embolization of paraclinoid aneurysm, especially projecting superiorly with large irregular shape, has the risk of progressive visual loss because of the proximity to optic nerve.

동맥관 개존증 개에서 색전 코일의 중재적 시술 후 발생한 폐성 고혈압 (Pulmonary Hypertension in a Dog after Embolic Coil Placement for Interventional Occlusion of Patent Ductus Arteriosus)

  • 이바른;김지윤;현창백
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.507-510
    • /
    • 2014
  • 8개월령 암컷 포메라니안 개가 심잡음과 심비대를 주호소로 내원하였다. 검사결과 좌-우단락 동맥관 개존증과 중등도의 심부전 (ISACHC II) 으로 진단되었다. 잔존 동맥관은 우측 대퇴동맥을 통한 $5mm{\times}3loops$ 코일 색전술을 통해 성공적으로 치료되었다. 2개월 후 환축은 현저한 저혈압과 심한 설사, 흉수가 차는 증상으로 다시 내원하였다. 검사 결과 심각한 폐성고혈압과 삼첨판 역류가 발견되었다. Sildenafil (3 mg/kg, PO, TID) 을 투여함으로써 임상증상은 조절되었으나, 코일빠짐과 보호자의 부적절한 투약으로 인해 환축은 폐사하였다. 부검 결과 폐성고혈압의 원인은 비정상적인 위치로 빠진 색전 코일에 의한 것으로 밝혀졌다. 토이 품종에서 PDA의 치료를 위해 색전 코일이 널리 사용되고 있지만, 장착된 코일이 빠질 위험을 줄이기 위해서는 PDA의 크기와 형태에 대한 한층 더 세심한 평가가 필요하다.

Comparison of Long-Term Angiographic Results of Wide-Necked Intracranial Aneurysms : Endovascular Treatment with Single-Microcatheter Coiling, Double-Microcatheter Coiling, and Stent-Assisted Coiling

  • Kim, Hyun Sik;Cho, Byung Moon;Yoo, Chan Jong;Choi, Dae Han;Hyun, Dong Keun;Shim, Yu Shik;Song, Joon Ho;Oh, Jae Keun;Ahn, Jun Hyong;Kim, Ji Hee;Chang, In Bok
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.751-762
    • /
    • 2021
  • Objective : Endovascular treatment of intracranial aneurysms is challenging in case of wide-necked aneurysms because coils are prone to herniate into the parent artery, causing thromboembolic events or vessel occlusion. This study aims to compare long-term angiographic results of wide-necked aneurysms treated by stent-assisted, double-microcatheter, or single-microcatheter groups. Methods : Between January 2003 and October 2016, 108 aneurysms that were treated with endovascular coil embolization with a neck size wider than 4 mm and a follow-up period of more than 3 years were selected. We performed coil embolization with single-microcatheter, double-microcatheter, and stent-assisted techniques. Angiographic results were evaluated using the Raymond-Roy occlusion classification (RROC). All medical and angiographic records were reviewed retrospectively. Results : Clinical and angiographic analyses were conducted in 108 wide-necked aneurysms. The immediate post-procedural results revealed RROC class I (complete occlusion) in 66 cases (61.1%), class II (residual neck) in 36 cases (33.3%), and class III (residual sac) in six cases (5.6%). The final follow-up results revealed class I in 48 cases (44.4%), class II in 49 cases (45.4%), and class III in 11 cases (10.2%). Of a total of 45 (41.6%) radiologic recurrences, there were 21 cases (19.4%) of major recurrence that required additional treatment, and 24 cases (22.2%) of minor recurrence. The final follow-up angiographic results showed statistically significant differences between the stent-assisted group and the others (p<0.01). Conclusion : Long-term follow-up angiography demonstrated that the stent-assisted technique had a better complete occlusion rate than the other two techniques.