• 제목/요약/키워드: three-phase inverter

검색결과 643건 처리시간 0.027초

보조 스위치를 이용한 3상 ZCS 인버터에 관한 연구 (A Study on the Three Phase Inverter using Auxiliary Switches)

  • 배진용;김용;백수현;최근수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.155-158
    • /
    • 2004
  • This paper proposes a soft-transition control strategy for a three phase ZCS(Zero Current Switching) inverter circuit. Each phase leg of inverter circuit consists of an LC resonant tank, two main switches, and two auxiliary switches. This paper presents design consideration via a study example of a three phase prototype inverter for motor drives. A simple device tester with zero current switching capability is proposed to select eligible auxiliary switches. The principle of operation, feature and design consideration is illustrated and verified through the experiment with a 2.2kW 5kHz IGBT based experimental circuit.

  • PDF

계통연계 태양광발전시스템의 제어기법 및 연계운전특성 (A control method and test results of utility interactive photovoltaic power generation systems)

  • 안교상;임희천;황인호;주형준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF

가변 노치필터에 의한 능동형 AC 전자부하의 3상 전류 불평형 저감 (Reduction of the Unbalanced Three Phase Input Current by Variable Notch Filter in Active AC Electronic Load)

  • 김도윤;이정효;이용석;정두용;정용채;원충연
    • 전력전자학회논문지
    • /
    • 제17권2호
    • /
    • pp.158-165
    • /
    • 2012
  • In this paper, the test bed using three-phase PWM converter connected with single phase inverter in series is set up to configure an active AC electric load. Since the two topologies, three-phase PWM converter and single-phase inverter, can be operated bidirectionally, the system not only re-generates surplus power to grid but also prevents power dissipation. However, the construction of system has a drawback. That is, ripple components two times of inverter operation frequency occur at DC-Link due to cascade connection, it can be cause of three phase unbalance Since the operational characteristic of the active AC electric load, the power frequency entered into the electric load can be varied, and the ripple of DC-Link is changed as well. In this paper, the three-phase PWM converter using a variable notch filter is proposed, and the reduction of three-phase current unbalance is presented. the validity of the proposed PWM converter using a variable notch filter is verified by the simulation and experimental results.

There-Phase Voltage-Source Soft-Switching Inverter with Auxiliary High Frequency Transformer Linked Power Regeneration Resonant Snubbers

  • Hattori, Hiroshi;Nakaoka, Mutsuo;Sakamoto, Kenji
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.153-158
    • /
    • 1998
  • In this paper, a prototype of the auxiliary resonant commutated snubber circuit(ARCS) with a high frequency transformer power regeneration loop is described for voltage source type sinewave inverter system. This is a new soft switching topology developed for three phase voltage source soft-switching inverter, active power filter and reactive power compensator has significant advantage of current rating reduction for auxiliary active switching devices. In addition, this paper presents a novel prototype of voltage-source soft switching space vector-modulated inverter with ARCS mentioned above, which is more suitable and acceptable for high-power utility interactive power conditioning, along with a digital control scheme. The steady-state operating analysis of ARCS has the remarkable features and the practical design procedure of this resonant snubber are illustrated on the basis of computer simulation analysis. The operating performance evaluations in the steady-state of this three phase voltage source soft switching inverter are discussed and compared with the three phase voltage source hard switching inverter.

  • PDF

A Novel Control Algorithm of a Three-phase Four-wire PV Inverter with Imbalance Load Compensation Function

  • Le, Dinh-Vuong;Kim, Chang-Soon;Go, Byeong-Soo;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1131-1137
    • /
    • 2018
  • In this paper, the authors suggest a new control algorithm for a three-phase four-wire photovoltaic (PV) inverter with imbalance load compensation function using conventional proportional-integral (PI) controllers. The maximum power of PV panel is calculated by the MPPT control loop. The reference varying signals of current controllers are transformed to two different rotating frames where they become constant signals. Then simple PI controllers are applied to achieve zero steady-state error of the controllers. The proposed control algorithm are modeled and simulated with imbalance load configuration to verify its performance. The simulation results show that the maximum PV power is transferred to the grid and the imbalance power is compensated successfully by the proposed control algorithm. The inverter has a fast response (~4 cycles) during the transient period. The proposed control algorithm can be effectively utilized to the three-phase four-wire inverter with imbalance load compensation function.

교류 전동기의 고효율 운전을 위한 3상 인버터의 입력전력 추정 기법 (Input Power Estimation Method of a Three-phase Inverter for High Efficiency Operation of an AC Motor)

  • 김도현;김상훈
    • 전력전자학회논문지
    • /
    • 제24권6호
    • /
    • pp.445-451
    • /
    • 2019
  • An input power estimation method of a three-phase inverter for the high-efficiency operation of AC motors is proposed. Measuring devices, such as DC link voltage and input current sensors, are required to obtain the input power of the inverter. In the proposed method, the input power of the inverter can be estimated without the input current sensor by using the phase current information of the AC motor and the switching pattern of the inverter. The proposed method is more robust to parameter error than conventional method. The validity of the input power estimation method is verified through experiments conducted on a 1 kW permanent-magnet synchronous motor drive system.

Field Oriented Control for Induction Motor Using Four Switch Three Phases Inverter

  • Tuyen, Nguyen D.;Hoang, Nguyen M.;Lee, Hong-Hee;Chun, Tae-Won
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.216-218
    • /
    • 2008
  • This paper presents a space vector pulse width modulation (SVPWM) technique for four-switch three-phase (4S3P) inverter topology. The method aims to apply Field Oriented Control (FOC) of Induction motor using 4S3P. The simulations are carried out and the experimental results are given to verify the feasibility of this method.

  • PDF

3상 멀티 레벨 인버터 구동 유도 전동기의 소음저감을 위한 3상 준 랜덤 캐리어 변조기법 (3-Phase Pseudo-Random Carrier Modulation Technique for the Acoustic Noise Reduction of the 3-Phase Multi-Level Inverter Based Motor)

  • 박진규;김종남;정영국;임영철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.742-745
    • /
    • 2005
  • This paper describes a simple pseudo-random carrier modulation technique for the acoustic noise reduction of the three phase multi-level inverter based motor drives. The proposed method generates a new pseudo-random carrier by randomly synthesizing a carrier with fixed frequency and a carrier with opposition phase. To confirm the validity of the proposed method, a 130v three-phase multi-level inverter was Implemented and tested. The experimental results show that the output line voltage and acoustic noise harmonics spectra of an inverter have broadening effect of harmonics, as only simple synthesis of fixed frequency carries.

  • PDF

3상 임베디드 Z-소스 인버터 (Three Phase Embedded Z-Source Inverter)

  • 오승열;김세진;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.486-494
    • /
    • 2012
  • In this paper, we proposes the three-phase embedded Z-source inverter consisting of the three embedded Z-source converters and it's the output voltage control method. Each embedded Z-source converter can produce the bipolar output capacitor voltages according to duty ratio D such as single-phase PWM inverter. The output AC voltage of the proposed system is obtained as the difference in the output capacitor voltages of each converter, and the L-C output filter is not required. Because the output AC voltage can be stepped up and down, the boost DC converter in the conventional two-stage inverter is unnecessary. To confirm the validity of the proposed system, PSIM simulation and a DSP based experiment were performed under the condition of the input DC voltage 38V, load $100{\Omega}$, and switching frequency 30kHz. Each converter is connected by Y-connection for three-phase loads. In case that the output phase voltage is the same $38V_{peak}$ as the input DC voltage and is the 1.5 times($57V_{peak}$), the simulation and experimental results ; capacitor voltages, output phase voltages, output line voltages, inductor currents, and switch voltages were verified and discussed.

3상 인버터의 계통 연계를 위한 동기화 방법론에 대한 연구 (A Study on the Synchronization Methodology for Grid-connection of Three Phase Inverter)

  • 임병석;이준성;웬황난;잔반탄;고윤석
    • 한국전자통신학회논문지
    • /
    • 제14권5호
    • /
    • pp.951-958
    • /
    • 2019
  • 분산 전원의 계통 연계를 위해서는 연계 전에 분산 전원 출력전압을 계통전압과 동기화시켜야 하는데, 전압의 크기, 위상 그리고 주파수를 일치시키는 문제이기 때문에 쉽지 않다. 본 연구에서는 3상 인버터의 계통 연계를 위한 벡터제어 기반의 동기화 알고리즘을 개발하였다. 하나의 3상 전압형 인버터를 설계, 제작하여 개발된 알고리즘의 유효성을 검증하였다. 3상 인버터의 주제어장치는 DSP 기반으로 개발되었고, 계통의 전기적인 레벨은 실험실에서 실험이 가능한 전기적 레벨로 하였다. 그리고 실험을 통하여 3상 인버터의 출력전압이 계통전압을 추종하여 동기화를 이루는 것을 보임으로서 제시된 알고리즘이 계통 연계를 위한 동기화 알고리즘으로 활용될 수 있음을 확인될 수 있었다.