• 제목/요약/키워드: three-phase dc-dc converter

검색결과 327건 처리시간 0.031초

Active Damping of LLCL Filters Using PR Control for Grid-Connected Three-Level T-Type Converters

  • Alemi, Payam;Jeong, Seon-Yeong;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.786-795
    • /
    • 2015
  • In this paper, an active damping control scheme for LLCL filters based on the PR (proportional-resonant) regulator is proposed for grid-connected three-level T-type PWM converter systems. The PR controller gives an infinite gain at the resonance frequency. As a result, the oscillation can be suppressed at that frequency. In order to improve the stability of the system in the case of grid impedance variations, online grid impedance estimation is applied. Simulation and experimental results have verified the effectiveness of the proposed scheme for three-phase T-type AC/DC PWM converters.

DSP-Based Direct Source Current Control for Three-Phase Four-Wire Power Coditioner

  • Jeong, C.Y.;Cho, J.G.;Baek, J.W.;Yoo, D.W.;Song, E.H.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.871-875
    • /
    • 1998
  • A DSP-based source current control for power conditioner is presented to compensate current harmonics and asymmetries of three-phase four-wire emergency generators caused by nonlinear and/or unbalanced loads. There-phase voltage type converter with split-dc-capacitor is adopted as the power circuit and a new direct source current control method is suggested, which simplifies the controller. The proposed control method shapes the generator current sinusoidally inphase with the voltage and allows the generator to supply maximum power even to single phase loads. An IGBT base lookVA prototype with the controller realized with a DSP (TMS320C32) is built and tested to verify the performance of the power conditioner.

  • PDF

모델 예측 제어 기반 Cascaded H-bridge 컨버터의 균일한 손실, 스위칭 주파수, 전력 분배를 위한 알고리즘 (An Algorithm for Even Distribution of Loss, Switching Frequency, Power of Model Predictive Control Based Cascaded H-bridge Multilevel Converter)

  • 김이김;곽상신
    • 전력전자학회논문지
    • /
    • 제20권5호
    • /
    • pp.448-455
    • /
    • 2015
  • A model predictive control (MPC) method without individual PWM has been recently researched to simplify and improve the control flexibility of a multilevel inverter. However, the input power of each H-bridge cell and the switching frequency of switching devices are unbalanced because of the use of a restricted switching state in the MPC method. This paper proposes a control method for balancing the switching patterns and cell power supplied from each isolated dc source of a cascaded H-bridge inverter. The supplied dc power from isolated dc sources of each H-bridge cells is balanced with the proposed cell balancing method. In addition, the switching frequency of each switching device of the CHB inverter becomes equal. A simulation and experimental results are presented with nine-level and five-level three-phase CHB inverter to validate the proposed balancing method.

시뮬레이터 컨버터에 의한 인버터 성능시험에 관한 연구 (A Study on the Inverter performance by Simulated Converter)

  • 조정민;조주현;김성남;이승환;오봉환;이훈구;김용주;한경희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.983-985
    • /
    • 2002
  • This paper is the machine that is able to estimate a new built power convertor in a production line. Generally, this machine test can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. But the proposal system is controlled to create some specific load characteristic needed for the test without any mechanical equipment. The suggested test stand consists only of a converter to be test and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. And then, to obtain a superior characteristic for dynamic reference used the feedforward control.

  • PDF

소프트 스위칭 3상 단일 스위치 승압형 컨버터 (Soft Switched Three-Phase Single Switch Boost-Type Converter)

  • 문상필;전찬욱;박성우;김대웅;김영문;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1166-1168
    • /
    • 2003
  • In most power electronic applications, the AC power input provided by the electronic utility needs to first converted to a DC voltage. Such conversion is accomplished by a diode rectifier due to its circuit simplicity and low cost. However, since diode rectifiers have some intrinsic problems such as low power factor and high harmonic distortion, a wide use of such rectifiers may cause noises, malfunction and heat damage in both electrical power systems and electrical machinery systems. This paper proposes soft switched three-phase single switch boost-type converter. The proposed circuit can perform Zero Voltage Switched(ZVS) without using any current and voltage sensors. For this circuit, both simulation and experiments have been performed. The results not only confirmed the ZVS but also indicated that, compared to the conventional hard switched converter, the prosed circuit can improve the efficiency as much as 1.7 to 4.7[%] while keeping the same high power factor and small harmonic distortion in their AC input.

  • PDF

On the Design of Power Supply System for Freight Train Reefer Container Based on Simulation

  • Kim, Joouk;Hwang, Sunwoo;Lee, Jae-Bum;Hwang, Jaemin;Chae, Uri
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제14권3호
    • /
    • pp.249-257
    • /
    • 2022
  • In recent years, if we order food by easily accessing the online market with our smartphone, we can receive the product in a fresh state at dawn the next day. Cold chain is an industry that can create high added value because it has both the characteristics of general logistics and sensitivity to temperature. Based on the electrical specifications derived from the reefer container capacity requirement investigation, we proved that power supply to up to 33 reefer containers can be made by using three additional auxiliary power supplies which are applied for freight trains in Korea. In this paper, we conducted a research on a design of power supply system for freight train reefer container based on simulation as a basic research necessary for low-temperature distribution and cold chain construction based on the reefer container railroad. Consequently, the simulation was conducted using the three-phase inverter diagram in PSIM and the SVPWM (3-harmonic injection method) control technique, and it was verified that the required power voltage was satisfied with 622Vdc, which is lower than the input voltage of general SPWM of 718Vdc. The details of this paper could be used as a foundational study for constructing cold chains based on a reefer container dedicated to freight trains in the future.

3상 Voltage Source Converter의 소신호 모델에 관한 연구 (A Study on Small-signal Model of Three-Phase Voltage Source Converter)

  • 금문환;김환용;한상규;노정욱;홍성수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.412-413
    • /
    • 2010
  • Voltage Source Converter(VSC)는 입력전류와 전압을 동상의 정현파로 제어할 수 있고, 전압을 승압하여 일정한 DC전압을 만들 수 있으며, 양방향 제어가 가능하다. 본 논문은 3상 VSC를 동기회전좌표계로 변환하여 등가회로로 모델링하고, VSC의 제어기와 소신호 등가모델을 제시한다. 시뮬레이션을 통해 회로해석과 소신호 등가모델의 타당성을 검증하였고, 실험결과를 통하여 제어기를 설계의 타당성을 증명하였다.

  • PDF

Control of Circulating Current in Modular Multilevel Converter under Unbalanced Voltage using Proportional-Resonant Controller

  • Quach, Ngoc-Thinh;Chae, Sang Heon;Kim, Eel-Hwan
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.143-144
    • /
    • 2016
  • The circulating current control within the phase legs is one of the main control objectives in a modular multilevel converter (MMC) under different operating conditions. This paper proposes a control strategy of circulating currents in the MMC under unbalanced voltage by using a proportional-resonant (PR) controller. Under the unbalanced voltage, the circulating currents in the MMC consists of three components such as positive-sequence, negative-sequence, and zero-sequence circulating currents. With the PR controller, all components of the circulating current will be directly controlled in the stationary reference frame without decomposing into positive- and negative-sequence components. Thus, the ripples in the circulating currents and the DC current are suppressed under the unbalanced voltage. The effectiveness of the proposed method is verified by simulation results based on PSCAD/EMTDC simulation program.

  • PDF

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.

추진인버터 시험을 위한 실시간 부하 시뮬레이터에 관한 연구 (Study on Real-Time Load Simulator for Testing Propulsion Inverter Test)

  • 김길동;신정렬;이우동;한석윤;박기준
    • 한국철도학회논문집
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 2004
  • A newly-built inverter has to undergo a series of stress tests in the final stage of production line. This can be achieved by connecting it to a dynamometer consisting of a three-phase machine joined by a rigid shaft to a DC load machine. The latter is controlled to create some specific load characteristic needed for the test. In this paper a test method is proposed, in which no mechanical equipment is needed. The suggested test stand consists only of a inverter to be tested and a simulator converter. Both devices are connected back-to-back on the AC-side via smoothing reactors. The simulator operates in real-time as an equivalent load circuit, so that the device under test will only notice the behaviour of a three-phase machine under consideration of the load. In oder to prove rightness of the suggested test method, the simulation and actural experiment carried out emulation for a 2.2kW induction motor.