• 제목/요약/키워드: three-phase dc-dc converter

검색결과 327건 처리시간 0.024초

하이브리드 3레벨 다출력 DC-DC 컨버터 (Multi Output Hybrid Three level DC-DC Converter)

  • 강철하;이하석;주종성;;김은수;이승민;김광섭
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 추계학술대회 논문집
    • /
    • pp.9-10
    • /
    • 2014
  • 최근 신재생에너지 및 전기자동차, 통신 IT 서버 전원 및 가전기기 등의 발전에 따라 고 전력밀도(High Power Density), 고 응답(Fast Transient Response) 및 고정밀(Tight Regulation) 출력제어를 위한 다 출력 절연형 DC/DC 컨버터가 개발 및 연구되고 있다. 본 논문에서는 개별적인 정밀제어를 요구하는 다 출력 DC-DC 컨버터에 대한 내용으로 위상천이(Phase-shift) DC-DC 컨버터와 LLC 공진컨버터 제어개념을 하나의 주회로를 사용하여 위상천이제어(Phase-shifted Modulation, PM)와 가변주파수제어(Variable Frequency Modulation, FM)를 통해서 개별적으로 정밀 제어할 수 있는 하이브리드 다 출력 3레벨 DC-DC 컨버터에 관한 내용이다.

  • PDF

A Single-Input Single-Output Approach by using Minor-Loop Voltage Feedback Compensation with Modified SPWM Technique for Three-Phase AC-DC Buck Converter

  • Alias, Azrita;Rahim, Nasrudin Abd.;Hussain, Mohamed Azlan
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.829-840
    • /
    • 2013
  • The modified sinusoidal pulse-width modulation (SPWM) is one of the PWM techniques used in three-phase AC-DC buck converters. The modified SPWM works without the current sensor (the converter is current sensorless), improves production of sinusoidal AC current, enables obtainment of near-unity power factor, and controls output voltage through modulation gain (ranging from 0 to 1). The main problem of the modified SPWM is the huge starting current and voltage (during transient) that results from a large step change from the reference voltage. When the load changes, the output voltage significantly drops (through switching losses and non-ideal converter elements). The single-input single-output (SISO) approach with minor-loop voltage feedback controller presented here overcomes this problem. This approach is created on a theoretical linear model and verified by discrete-model simulation on MATLAB/Simulink. The capability and effectiveness of the SISO approach in compensating start-up current/voltage and in achieving zero steady-state error were tested for transient cases with step-changed load and step-changed reference voltage for linear and non-linear loads. Tests were done to analyze the transient performance against various controller gains. An experiment prototype was also developed for verification.

3상 임베디드 Z-소스 인버터 (Three Phase Embedded Z-Source Inverter)

  • 오승열;김세진;정영국;임영철
    • 전력전자학회논문지
    • /
    • 제17권6호
    • /
    • pp.486-494
    • /
    • 2012
  • In this paper, we proposes the three-phase embedded Z-source inverter consisting of the three embedded Z-source converters and it's the output voltage control method. Each embedded Z-source converter can produce the bipolar output capacitor voltages according to duty ratio D such as single-phase PWM inverter. The output AC voltage of the proposed system is obtained as the difference in the output capacitor voltages of each converter, and the L-C output filter is not required. Because the output AC voltage can be stepped up and down, the boost DC converter in the conventional two-stage inverter is unnecessary. To confirm the validity of the proposed system, PSIM simulation and a DSP based experiment were performed under the condition of the input DC voltage 38V, load $100{\Omega}$, and switching frequency 30kHz. Each converter is connected by Y-connection for three-phase loads. In case that the output phase voltage is the same $38V_{peak}$ as the input DC voltage and is the 1.5 times($57V_{peak}$), the simulation and experimental results ; capacitor voltages, output phase voltages, output line voltages, inductor currents, and switch voltages were verified and discussed.

확장된 동작 영역을 갖는 3상 전압원 PWM 컨버터의 최적 제어 (Optimal Control of a Three-Phase Voltage-Source PWM Converter with an Expanded Operation Region)

  • 민동기;안성찬;현동석;최종률
    • 전력전자학회논문지
    • /
    • 제3권2호
    • /
    • pp.156-164
    • /
    • 1998
  • 3상 전압원 PWM 컨버터의 동작 영역을 동기 좌표계의 전류 벡터 평면에서 구분하고 그 특징을 설명하였다. 그 중 감역률 영역에서는 주어진 부하에 해당하는 입력 전류를 단위 역률로 제어하는 경우, 입력 전류는 왜곡되고 DC 링크 전압에는 맥동과 제어 오차가 발생하게 되어 주어진 부하 조건에서는 좋은 제어 성과를 얻을 수 없다. 본 논문에서는 이러한 문제점을 해결하는 최적 전류 벡터를 선정하는 방법을 제안하였다. 최적 전류 벡터의 선정으로 입력 전류를 가능한 최대 역률로서 정현적으로 제어하는 동시에 안정한 DC 링크 전압을 제어할 수 있게 하여 3상 전압원 PWM 컨버터의 동작 영역을 확장시킬 수 있다. 제안된 제어 방법을 실험을 통하여 증명하였다.

3상 능동클램프 하이브리드 정류형 DC-DC 컨버터 (Three-Phase DC-DC Converter with Active clamped hybrid Rectifier)

  • 한국인;최세완;김민국
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.150-151
    • /
    • 2010
  • 본 논문에서는 5kW급 연료전지 응용을 위한 3상 DC-DC 컨버터를 제안한다. 제안한 컨버터의 Delta-Wye 결선은 전압형의 가장 큰 단점인 변압기 턴비를 최소화 하였으며 클램프 스위치의 동작으로 전압 및 전류 공진을 감소시키고 순환전류를 리셋시켜 각 소자들의 전류정격을 줄였다. 기존 3상 Full-Bridge와 비교 분석을 수행하였으며 시뮬레이션을 통해 타당성을 검증하였다.

  • PDF

Model Predictive Control of Bidirectional AC-DC Converter for Energy Storage System

  • Akter, Md. Parvez;Mekhilef, Saad;Tan, Nadia Mei Lin;Akagi, Hirofumi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.165-175
    • /
    • 2015
  • Energy storage system has been widely applied in power distribution sectors as well as in renewable energy sources to ensure uninterruptible power supply. This paper presents a model predictive algorithm to control a bidirectional AC-DC converter, which is used in an energy storage system for power transferring between the three-phase AC voltage supply and energy storage devices. This model predictive control (MPC) algorithm utilizes the discrete behavior of the converter and predicts the future variables of the system by defining cost functions for all possible switching states. Subsequently, the switching state that corresponds to the minimum cost function is selected for the next sampling period for firing the switches of the AC-DC converter. The proposed model predictive control scheme of the AC-DC converter allows bidirectional power flow with instantaneous mode change capability and fast dynamic response. The performance of the MPC controlled bidirectional AC-DC converter is simulated with MATLAB/Simulink(R) and further verified with 3.0kW experimental prototypes. Both the simulation and experimental results show that, the AC-DC converter is operated with unity power factor, acceptable THD (3.3% during rectifier mode and 3.5% during inverter mode) level of AC current and very low DC voltage ripple. Moreover, an efficiency comparison is performed between the proposed MPC and conventional VOC-based PWM controller of the bidirectional AC-DC converter which ensures the effectiveness of MPC controller.

3상 전압형 PWM 컨버터의 전압 센서리스 제어 (Voltage Sensorless Control for Three-Phase Voltage Source PWM Converter)

  • 허태원;조광승;김영빈;서정기;조용길;우정인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2656-2658
    • /
    • 1999
  • This paper presents a control scheme for a three-phase PWM converter system without any voltage sensors. Two input currents and one load current are measured. In a general PWM converter system, the required AC input and DC output voltage values in order to control the converter are estimated using the differential equations of the converter from the measured input currents and load current values in the switch modes of the converter circuit. The PI controller is used as DC voltage controller and sinusoidal tracking controller which tracks directly AC input current is used as input current controller. The Proposed method is verified by simulations. This paper describes the estimation method and configuration of the controller, and discusses steady state and transient performances of the converter

  • PDF

가상 자속관측기를 이용한 3상 AC/DC PFC PWM 컨버터의 직접 전력 센서리스 제어 (Direct Power Sensorless Control of Three-Phase AC/DC PFC PWM Converter using Virtual Flux Observer)

  • 김영삼;권영안
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1442-1447
    • /
    • 2012
  • In this paper, direct power control system for three-phase PWM AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the Reduced-order flux observer using the actual currents and the command control voltage. The source voltage sensors are replaced by a flux estimator. The active and reactive powers estimation are performed based on the estimated flux and Phase anble. The proposed algorithm is verified through simulation and experiment.

역상분 추출을 사용한 DC마이크로그리드의 3상 4선식 방식의 인터링킹 컨버터 (DC microgrid three-phase four-wire interlinking converter using negative-sequence extraction)

  • 김미나;강진욱;김범준;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2019년도 전력전자학술대회
    • /
    • pp.118-120
    • /
    • 2019
  • 제안하는 논문은 3상 4선식 방식의 Interlinking Converter(ILC)를 사용하여 DC bus와 AC bus를 연계 한다. 역상분 성분은 정상분 성분과 다르게 전압 평형시 발생하지 않다가 전압 불평형시 발생하기 때문에 역상분을 추출하여 제어함으로써 불평형을 개선한다. Psim 시뮬레이션을 통해 본 논문의 타당성을 검증한다.

  • PDF

DC 48[V] 통신용 전원 장치의 특성 (Characteristics of DC 48[V] telecommunication power supply)

  • 정현태;조만철;윤영태;김주용;문상필;서기영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.902-904
    • /
    • 2005
  • The AC-DC converter, which has three-phase AC power as input and isolated DC power as output is used for the regulated DC power supply of the telecommunication power processing system for several kilowatt class applications. The conventional DC power supply for the telecommunication power system comprises a PWM rectifier with sine-wave shaping input current unity power factor and a DC/DC converter connected to the PWM converter, which obtains DC 48[V]. Since power passes through these two power stage converters, the conversion power loss is difficult to provide high efficiency. To resolve these problems, this paper presents a new PWM rectified as a 1-stage power conversion method. It simulation and experimental results as proved from a practical point of view that 92.1[%]of conversion efficiency and input current which can meet harmonics regulation of the Class-A in IEC61000-3-3 are achieved.

  • PDF