• 제목/요약/키워드: three-phase PWM inverter

검색결과 238건 처리시간 0.025초

마이크로 프로세서에 의한 영구자석동기 전동기의 구동 (Microprocessor Based Permanent Magnet Synchronous Motor Drive)

  • Yoon, Byung-Do
    • 대한전기학회논문지
    • /
    • 제35권12호
    • /
    • pp.541-554
    • /
    • 1986
  • This paper presents the results of driving performance analysis of permanent magnet synchronous motor using a microprocessor based control system. The system consists of three phase power transistor inverters, three phase controlled rectifier, three central processing units, and sensors. The three CPUs are, respectively, used to generate PWM control signals for the inverter generating three phase sine wave, to generate the gate control signals for firing the converter, and to supervise other two CPUs. The supervisor is used to compute PI control algtorithm to three phase reference sine wave for the inverter. It is also used to maintain a constant voltage frequency ratio for the converter operating as a constant torque controller. The inverter CPU retrieves precomputed PWM patterns from look up tables because of computation speed limitations found in almost available microprocessors. The converter CPU also retrieves precomputed gate control patterns from another look-up tables. For protecting the control ststem from any damage by extraordinary over currents, the supervisor receives the data from current sensor, CT, and break down the CB to isolate the circuits from source. A resolver has a good performance characteristics of overall speed range, especially on low speed range. Therefor the speed control accuracy is impoved. The microprocessor based PM synchronous motor control system, thus, has many advantages such as constant torque characteristics, improvement of wave, limitation on extraordinary over currents, improvement of speed control accuracy, and fast response speed control using multi-CPU and look-up tables.

  • PDF

철도차량 추진시스템을 위한 FLI(Five-leg Inverter)의 성능 분석 (Performance Analysis of a Five-leg Inverter for the Train Propulsion System)

  • 임영설;신덕호;이준석;이교범
    • 한국철도학회논문집
    • /
    • 제20권1호
    • /
    • pp.43-54
    • /
    • 2017
  • 본 논문에서는 철도차량 추진시스템을 위한 3-레그 인버터와 5-레그 인버터의 성능을 비교/분석하고 철도차량에 5-레그 인버터를 적용함에 있어 최적의 동작 조건을 제시한다. 5-레그 인버터는 두 대의 3-레그 인버터에 비해 2개의 스위치가 감소되며, 하나의 제어보드로 두 대의 3상 전동기를 독립적으로 제어할 수 있다. 이로 인해 두 대의 3-레그 인버터를 이용할 경우보다 시스템의 비용 감소와 소형화가 가능하다. 본 논문에서는 먼저 도시철도 차량에서 사용중인 유도전동기 제어 기법과 PWM 방법을 분석한다. 다음으로 5-레그 인버터의 기본 동작과 특징을 분석한다. 이러한 분석을 바탕으로 동일한 유도전동기 제어 기법과 PWM 방법을 3-레그 인버터와 5-레그 인버터에 적용했을 때 유도전동기의 속도와 토크 특성을 비교하고 분석한다.

Modified Unipolar Carrier-Based PWM Strategy for Three-Level Neutral-Point-Clamped Voltage Source Inverters

  • Srirattanawichaikul, Watcharin;Premrudeepreechacharn, Suttichai;Kumsuwan, Yuttana
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.489-500
    • /
    • 2014
  • This paper presents a simple modified unipolar carrier-based pulsewidth modulation (CB-PWM) strategy for the three-level neutral-point-clamped (NPC) voltage source inverter (VSI). Analytical expressions for the relationship between modulation reference signals and output voltages are derived. The proposed modulation technique for the three-level NPC VSI includes the maximum and minimum of the three-phase sinusoidal reference voltages with zero-sequence voltage injection concept. The proposed modified CB-PWM strategy incorporates a novel method that requires only of one triangular carrier wave for generate the gating pulses in three-level NPC VSI. It has the advantages of being simplifying the algorithm with no need of complex two/multi-carrier pulsewidth modulation or space vector modulation (SVM) and it's also simple to implement. The possibility of the proposed CB-PWM technique has been verified though computer simulation and experimental results.

3상 계통연계 태양광발전시스템의 운전특성 (Control Characteristics of Three-Phase Utility Interactive Phovotovoltaic Power Generation System)

  • 김영철;정명웅;서기영;이현우;우준인
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.536-543
    • /
    • 2000
  • The photovoltaic power generation system has a great future as clean energy instead of fossil fuel which has many environmental problems such as exhausted gas or air pollution. In a utility interactive photovoltaic generation system, a three-phase inverter is used for the connection between the photovoltaic array and the utility. This paper present a three phase inverter for photovoltaic power system with current controller, voltage controller, PLL Control system and the Phase detector of Interactive Voltage by using dq transformation. The proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor.

  • PDF

PWM 인버터와 PWM 정류기에서 공간벡터변조 (Space Vector Modulation in PWM Inverters and PWM Rectifiers)

  • 권봉환;김한태
    • 대한전기학회논문지
    • /
    • 제41권7호
    • /
    • pp.742-752
    • /
    • 1992
  • In this paper, a space vector concept is generalized for PWM(pulse-width modulated) inverters and PWM rectifiers with current link and voltage link respectively. Through representing three-phase variables as a space vector, we propose space vector modulations for PWM voltage and current source inverters, and PWM rectifiers with current link and voltage link. For these types, switching states of the switches are systematically analyzed from tables. It is shown in three-phase PWM rectifiers that power factor of the line current and output dc voltage can be controlled arbitrarily. The PWM rectifier with current link is also given as an example system.

  • PDF

DSP320F240을 이용한 PWM-Inverter구동 시스템에서의 전도노이즈 저감을 위한 스위칭 기법 (A Switching Technique for Common Mode Voltage Reduction of PWM-Inverter System using the DSP320F240)

  • 박현석;박규현;김이훈;한성용;원충연;김영렬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.355-359
    • /
    • 2002
  • Much attention has been given to EMI effects created in variable speed ac drive system. Zero switching states of inverter control invoke large common mode voltage. This paper focuses on the switching techniques to mitigate common mode voltage. This paper proposes a common-mode voltage reduction method based on sinusoidal pulse width modulation in three phase PWM inverter system. By using three carriers wave displaced by 120 degrees, it is possible to eliminate a common mode voltage pulse In one control period. Simulation and experimental results show that common mode voltages In the proposed technique are reduced more than conventional technique.

  • PDF

VSI-PWM 인버터의 고주파 영향을 최소화하기 위한 새로운 Optimal PWM 방식 (New Optimal PWM Scheme for Minimizing the Harmonic Effects of VSI-PWM Inverter)

  • 이윤종;이일형;정동화
    • 한국통신학회논문지
    • /
    • 제15권11호
    • /
    • pp.886-897
    • /
    • 1990
  • 본 논문은 PWM 패턴의 연적 펄스폭 사이에서 정의된 선형관계에 기초한 새로운 optimal PWM 방식을 제시하였다. 새로운 PWM 방식에서 펄스폭 계산은 MW와 CW의 방정식에 의존하지않고 수행할 수 있다. 이 방식에 의해 마이크로프로세서로 제어되는 인버터를 위한 PWM 패턴은 패턴의 연적 펄스폭에서 최적 증분치를 얻으므로서 쉽게 구성할 수 있다. 더구나, PWM 인버터의 출력에서 고조도레벨은 본 PWM패턴이 최소 THD를 기초로 선정되기 때문에 항상 적다. 본 방식을 1(HP), 삼상 유도전동기에 적용시켜 종래의 regular PWM 방식과 비교해 보았다. 계산 및 실험의 결과에서 새로운 optiaml PWM 방식이 VSI-PWM 인버터에서 고조도를 최소화하기 위한 효과적인 일반화 연구임을 보였다.

  • PDF

전압형 PWM 컴버터를 이용한 3상 능동 전력 필터에 관한 연구 (A Study on The Three-Phase Active Power Filter Using Voltage-Source PWM Converter)

  • 박민호;김한성;최규하;이제필
    • 대한전기학회논문지
    • /
    • 제38권5호
    • /
    • pp.370-379
    • /
    • 1989
  • 본 논문은 전압형 PWM컨버터를 이용한 3상 능동전력 필터에 관해 연구하였다. 능동 필터는 6-펄스정류기의 입력측에 나타나는 고조파를 제거함과 동시에 무효전력을 보상하며, 3상 PMW인버터와 커패시티로 구성된다. 보상전류를 가급젓 현존하는 전류에 가깝게 발생시키고 필터의 속응성을 개선하고자 히스테리시스 제어기법을 사용하였고 이에 관한 제어회로는 간단히 구성될 수 있다. 그결과 교류입력측 전류는 정현파로 보상되고 역율 또한 거의 1로 개선할 수 있었다.

NTV 식별과정 없는 멀티레벨 인버터의 신속한 공간벡터 PWM 변조기법

  • 오진석;이종호;진선호;곽준호;조관준;김종도
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.253-254
    • /
    • 2006
  • this paper suggest a new space vector PWM modulation method with short processing time which does not need idenfication of nearest three vectors(NTV) and duty calculation for each vector. The suggested PWM method makes mean value of phase voltage to be same as reference during every modulation period by use of a triangle in small hexagon on multi-level vector space. This paper described the suggested modulation method can be successfully applied to the space vector modulation use of multi-level inverter by computer simulations and experiments.

  • PDF

새로운 공간벡터 Random Position PWM기법 (A New Space Vector Random Position PWM Scheme)

  • 김회근;임영철;나석환;정영국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.168-174
    • /
    • 2001
  • In this paper, a new space vector RPPWM (Random Position PWM) is proposed. In the proposed RPPWM, each of three phase pulses is located randomly in each switching interval. Based on the space vector modulation technique, the duty ratio of the pulses is calculated. Along with the randomization of the PWM pulses, we can obtain the effects of spread spectra of voltage, current as in the case of randomly changed switching frequency. To verify the validity of the proposed RPPWM, simulation study was tried using Matlab/simulink. The main model described in Simulink block diagrams includes the space vector modulation block, pulse position randomization block, inverter block, 3 phase induction motor block, and so on. By the simulation study, the harmonics of the output voltage, and the current of inverter are predicted in different PWM methods- SVPWM, LLPWM, proposed RPPWM.

  • PDF