• 제목/요약/키워드: three-electrode system

검색결과 194건 처리시간 0.036초

AFM팁/강유전박막/전극 시스템에서의 스위칭 영역의 형성 (Formation of Switching Zones in an AFM Tip/Ferroelectric Thin Film/BE System)

  • 김상주;신준호;김윤재
    • 대한기계학회논문집A
    • /
    • 제27권6호
    • /
    • pp.849-856
    • /
    • 2003
  • A three-dimensional constitutive model for polarization switching in ferroelectric materials is used to predict the formation of switching zones in an atomic force microscopy(AFM) tip/ferroelectric thin film/bottom electrode system via finite element simulation. Initially the ferrolectric film is poled upward and the bottom electrode is grounded. A strong dc field is imposed on a fixed point of the top surface of the film through the AFM tip. A small switching zone with downward polarization is nucleated and grows with time. It is found that initially the shape of the switched zone is that of a bulgy dagger, but later turn to the shape of a reversed cup with the lower part wider than the upper part. It can also be concluded that the size of switching zones increases with the period of applied electric potential. The present results are qualitatively consistent with experimental observations.

트리거 진공 스위치 개발 (Development of Triggered Vacuum Switch (TVS))

  • 박성수;한영진;이병준;김상희;남상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2126-2128
    • /
    • 2000
  • A TVS(triggered vacuum switch) use in high-power, high-current, and high-frequency conversion and switching circuits. The TVS has a six-gap trapezoidal rod electrode system. The electrode system consists of three cathode and anode rods which are made with OFHC. The trigger unit of the TVS is located at the cathode base center. To obtain a wide variety of characteristics this paper describes the results of tests.

  • PDF

부분방전에 의한 음향신호의 검출과 위치추정에 관한 연구 (A Study on the Detection of Acoustic Signal Produced by Partial Discharges in Insulation Oil and its Positioning)

  • 길경석;박대원;김일권;최수연;박찬용
    • 한국전기전자재료학회논문지
    • /
    • 제20권10호
    • /
    • pp.907-911
    • /
    • 2007
  • This paper dealt with the frequency spectrum analysis of acoustic signal produced by partial discharge (PD) in insulation oil and the positioning of PD occurrence to apply in diagnosis of oil insulated transformers. Three types of electrode system ; the needle-plane, the plane-plane, and the wire-wire structure were assembled to simulate partial discharges in oil insulated transformers. A low-noise amplifier and a decoupling circuit were designed to detect acoustic signal with high sensitivity The frequency spectrum of the acoustic signal were 50 kHz ${\sim}$ 260 kHz in the needle-plane, 50 kHz ${\sim}$ 250 kHz in the plane-plane, and 45 kHz${\sim}$195 kHz in the wire-wire electrode system. Their peak frequencies were 145 kHz, 130 kHz and 114 kHz, respectively The position of PD occurrence was calculated by the time difference of arrival (TOA) using three acoustic emission (AE) sensors, and we could find the position within the error of 1 % in the experimental apparatus.

휴대형 각성도 측정 및 분석 시스템 (Portable arousal measurement and analysis system)

  • 고한우;김연호;김철중;이건기
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.60-64
    • /
    • 1996
  • This paper describes the development of portable arousal measurement and analysis system. Skin impedance change which responds the change of arousal level was detected by the three electrode constant current method and separated into two components (SIR, SIL). Relationship between Nz, IRI and arousal level was studied and Criteria of arousal level control was decided by the sleep study.

  • PDF

ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템 (The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal)

  • 김정도;김갑진;정기수;이정환;안진호;이상국
    • 정보처리학회논문지A
    • /
    • 제17A권3호
    • /
    • pp.145-152
    • /
    • 2010
  • 대부분의 모바일 웨어러블 헬스케어 모니터링 의류 시스템은 생체신호를 측정할 수 있는 센서와 데이터 취득과 무선 통신 및 제어를 담당하는 회로부, 이들을 내장하는 의복으로 구성된다. 기존의 의복형 헬스케어 시스템은 센서를 의복에 장시간 내장하기가 어렵고, 피부 접촉 시 시간에 따라 저항 값이 변화하기 때문에 장기적인 생체 신호 모니터링이 쉽지 않으며, 센서 전극과 회로 사이에 존재하는 신호선의 물리적 장애 요인도 가지고 있다. 본 연구에서는 이러한 문제점들을 해결하기 위하여, PVDF에 PEDOT 재료를 코팅하여 만든 패브릭 나노웹 ECG 전극과 PVDF 필름을 사용한 호흡 센서를 $10\;{\mu}m$ 두께의 디지털 실을 이용하여 사용자의 의류와 일체화하였다. 탈부착이 가능한 무선 블루투스(Bluetooth) 내장 스테이션과 디지털실로 기존 의류와 일체화한 생체 신호 측정용 의류 제작을 통해, 휴대폰에서 손쉽게 심전도(ECG)와 맥박신호를 표시 할 수 있었다.

직류전기장에 의한 기포의 변형과 이탈에 관한 연구 (A Study on the Bubble Deformation and Departure Under DC Electric Field)

  • 권영철;김무환;강인석;김석준
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1518-1528
    • /
    • 1995
  • The deformation and departure processes of a bubble attached to the wall are studied experimentally and numerically to understand the phenomena of the nucleate boiling heat transfer enhancement under DC electric field. An air-bubble is injected in a dielectric liquid with different electric fields generated by changing three types of electrode system (Type 1,2 and 3) in the bubble generator. Experimental variables are the electric field strength and the distance and the shape of the electrodes under DC electric field. From experimental results, it is observed that the bubble under Dc electric field is elongated in the same direction as the electric field and the contact angle increases. For the parallel plate electrode which generates a uniform electric field, bubble departure volume doesn't seem to decrease within our experimental range. However, when a needle is raised a few millimeters from the lower electrode to make a nonuniform electric field around the needle, bubble departure volume decreases continuously with the increase of an applied voltage. The reduction effect of bubble departure volume is the most effective under a strong nonuniform electric field generated with Type 3. As the nonuniformity of the electric field due to the shape of a electrode increases, the terminal velocity and the acceleration of a bubble increase largely. For the comparison with visualization results, the deformation of a bubble attached to the electrode is carried out by a numerical method. Numerical results show good agreement qualitatively with experimental results.

폐 플로랄 폼을 이용한 슈퍼커패시터용 다공성 탄소 폼 제조 및 전기화학 성능 평가 (Preparation and Electrochemical Characterization of Porous Carbon Foam from Waste Floral Foam for Supercapacitors)

  • 이병민;박진주;박상원;윤제문;최재학
    • 한국재료학회지
    • /
    • 제32권9호
    • /
    • pp.369-378
    • /
    • 2022
  • The recycling of solid waste materials to fabricate carbon-based electrode materials is of great interest for low-cost green supercapacitors. In this study, porous carbon foam (PCF) was prepared from waste floral foam (WFF) as an electrode material for supercapacitors. WFF was directly carbonized at various temperatures of 600, 800, and 1,000 ℃ under an inert atmosphere. The WFF-derived PCF (C-WFF) was found to have a specific surface area of 458.99 m2/g with multi-modal pore structures. The supercapacitive behavior of the prepared C-WFF was evaluated using a three-electrode system in a 6 M KOH aqueous electrolyte. As a result, the prepared C-WFF as an active material showed a high specific capacitance of 206 F/g at 1 A/g, a rate capability of 36.4 % at 20 A/g, a specific power density of 2,500 W/kg at an energy density of 2.68 Wh/kg, and a cycle stability of 99.96 % at 20 A/g after 10,000 cycles. These results indicate that the C-WFF prepared from WFF could be a promising candidate as an electrode material for high-performance green supercapacitors.

Investigation of Water Safety in Non-treated Drinking Water with Trace Toxic Metals

  • Ly, Suw Young;Kim, Dae Hong;Lee, Ga Eun
    • Toxicological Research
    • /
    • 제29권3호
    • /
    • pp.211-215
    • /
    • 2013
  • The trace toxic metal copper was assayed using mercury immobilized on a carbon nanotube electrode (MCW), with a graphite counter and a reference electrode. In this study, a macro-scale convection motor was interfaced with a MCW three-electrode system, in which a handmade MCW was optimized using cyclic- and square-wave stripping voltammetry. An analytical electrolyte for tap water was used instead of an expensive acid or base ionic solution. Under these conditions, optimum parameters were 0.09 V amplitude, 40 Hz frequency, 0.01 V incremental potential, and a 60-s accumulation time. A diagnostic working curve was obtained from 50.0 to 350 ${\mu}g/L$. At a constant Cu(II) concentration of 10.0 ${\mu}g/L$, the statistical relative standard deviation was 1.78% (RSD, n = 15), the analytical accumulation time was only 60 s, and the analytical detection limit approached 4.6 ${\mu}g/L$ (signal/noise = 3). The results were applied to non-treated drinking water. The content of the analyzed copper using 9.0 and 4.0 ${\mu}g/L$ standards were 8.68 ${\mu}g/L$ and 3.96 ${\mu}g/L$; statistical values $R^2$ = 0.9987 and $R^2$ = 0.9534, respectively. This method is applicable to biological diagnostics or food surveys.

4-Octyl-4'-(5-carboxy-pentamethylene-oxy)azobenzene과 Dilauroyl-L-${\alpha}$- Phosphayidylcholine의 혼합 LB막의 전기화학적 특성 (Electrochemical Properties of Langmuir-Blodgett Films of 4-Octyl-4'-(5-carboxy-pentamethylene-oxy)azobenzene and Dilauroyl-L-${\alpha}$-Phosphayidylcholine Mixture)

  • 김범준;민병철;박근호
    • 한국응용과학기술학회지
    • /
    • 제19권1호
    • /
    • pp.49-55
    • /
    • 2002
  • We carried out this experiment to observe electrochemical properties for LB films of phospholipid(Dilauroyl-L-${\alpha}$-Phosphayidylcholine) and 4-octyl-4'-(5-carboxypentamethylene-oxy)azobenzene mixture by the cyclic voltammetry. LB films of 8A5H and 8A5H-DLPC(1:1, 2:1) were deposited by using the Langmuir-Blodgett method on the ITO glass. We determined electrochemical measurement by using cyclic voltammetry with a three-electrode system, An Ag/AgCl reference elect rode, a platinum wire counter electrode and LB film-coated ITO working electrode measured in 0.1, 0.5, and 1.0 mol/L $NaClO_{4}$ solution. A measuring range was reduced from initial potential to -1350 mV, continuously oxidized to 1650 mV and measured to the initial point. The scan rate were 50, 100, 150 and 200 mV/s. As a result, LB films of 8A5H 8A5H-DLPC appeared irreversible process caused by only the oxidation current from the cyclic voltammogram.

포도당 센서의 제작을 위한 고정화 방법의 전기화학적 결정 (Electrochemical Determination of Immobilization Technique for Glucose Sensor Fabrication)

  • 정태훈;홍석인;노봉수;정용섭;윤정원;김태진
    • KSBB Journal
    • /
    • 제13권1호
    • /
    • pp.52-57
    • /
    • 1998
  • The present work proposes a simple electrochemical method applicable to any immobilization processes of oxidase using a Clark type oxygen electrode as a base transducer. The present work suggests an optimal immobilization technique among three different methods of glucose oxidase(GOD) onto one side of $37[\mu}$mthick blend membranes, composed o 80% of cellulose triacetate and 20% of polycaprolactone, on the basis of the maximum Michaelis-Menten parameter(Vm) determined by either steady state or transient analyses. The electrode system was made of disk type gold cathode(4mm diameter) and Ag/AgCl anode. One side of the blend membrane was in contact with the cathode surface while the other side was immobilized with GOD either in covalent-bond or cross-linked forms, the latter being covered by $25{\mu}$m thick dialysis membrane of cellulose acetate. The resultant current density was on-line monitored by a potentiostat while glucose level was varied from 1 to 20 mM. The present study shows that direct cross-linking of GOD with glutaraldehyde was mostly preferred for fabrication of glucose sensor, on the basis of resultant kinetic parameters from either steady state or transient analyses.

  • PDF