• Title/Summary/Keyword: three-dimensions

Search Result 1,908, Processing Time 0.032 seconds

The Effect of Chinemys reevesii Gray Pharmacopuncture for Women with Knee Osteoarthritis (구판(龜板)약침이 여성의 퇴행성 슬관절염에 미치는 영향)

  • Shin, So Yeon;Seo, Dong Kyun;Kim, Shin Young;Seo, Jong Cheol;Seo, Yeon Ju;Lee, Yoon Joo;Bin, Chang Hyun;Jung, Taek Gun;Song, Chun Ho;Yoon, Hyun Min;Kim, Cheol Hong;Jang, Kyung Jeon
    • Journal of Acupuncture Research
    • /
    • v.32 no.3
    • /
    • pp.163-173
    • /
    • 2015
  • Objectives : The aim of this study is to determine whether Chinemys reevesii Gray pharmacopuncture is a clinically effective treatment for women with knee osteoarthritis. Methods : Female patients with knee osteoarthritis were recruited from May $1^{st}$, 2014 to April $15^{th}$, 2015 at the Department of Acupuncture & Moxibustion Medicine of Dong-Eui University Korean Medical Hospital. Patients were randomly assigned to two groups. 4.0 ml of Chinemys reevesii Gray pharmacopuncture was injected at acupuncture points of the experimental group(n = 24) twice a week for three weeks. The control group(n = 24) received 5 % dextrose injections in order to identically stimulate the same acupuncture points of $ST_{35}$, $ST_{34}$, $SP_9$, $SP_{10}$, $GB_{34}$, $LR_8$, $EX-LE_4$, and $EX-LE_2$. The Short-Form McGill Pain Questionnaire(SF-MPQ), the Korean Western Ontario and McMaster Universities Osteoarthritis Index(KWOMAC), and the European Quality of Life-5 Dimensions(EQ-5D) were recorded to evaluate treatment efficacy at first visit, after two weeks and four weeks from the initial visit. Results : 40 patients completed the trial. The experimental group showed more significant improvement than the control group in the scores of SF-MPQ, KWOMAC, and EQ-5D. However, there was no significant difference between groups in a few of the assessment scales. Conclusions : Chinemys reevesii Gray pharmacopuncture can be an effective treatment in control of pain, improvement in function and health-related quality of life for women with knee osteoarthritis.

Mandibular Clinical Arch Forms in Koreans with Normal Occlusions (한국인 정상교합자의 하악 치열궁 형태)

  • Yun, Young-Kuk;Kook, Yoon-Ah;Kim, Seong-Hoon;Mo, Sung-Seo;Cha, Kyung-Suk;Kim, Jong-Ghee;Tae, Ki-Chul
    • The korean journal of orthodontics
    • /
    • v.34 no.6 s.107
    • /
    • pp.481-487
    • /
    • 2004
  • The purpose of this study was to clarify morphologic characteristics between mandibular clinical arch forms in Koreans with normal occlusions. The study included data from 102 Koreans. The most facial portion of 13 proximal contact areas was digitized from photocopied images of the mandibular dental arches. Clinical bracket points were calculated for each tooth based on mandibular tooth thickness data. Four linear and two proportional measurements were taken. The dental arches were classified into ovoid, square and tapered forms. The frequency distributions of the three mandibular arch form classifications were determined and compared between male and female subjects. No significant differences in arch form size were found between the sexes. However, there were a few differences in molar width. It was useful to classify mandibular clinical arch forms present in normal occlusion samples into ovoid, square and tapered categories. The frequency of the ovoid form was the highest, and that of the square form was the second highest. The tapered arch form was found in less than 10 percent of subjects. No significant differences in their frequency distributions and dimensions were shown between males and females.

Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography (Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가)

  • Hong, Jong-Hyun;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

A Theoretical Review of Research on Entrepreneurial Orientation (기업가적 지향성에 대한 이론적 동향 연구)

  • Yoon, Hyun Joong
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.10 no.5
    • /
    • pp.45-62
    • /
    • 2015
  • Entrepreneurial Orientation (EO hereafter) can be described as firm level entrepreneurial tendencies. Initially Miller(1983) clarifies the construct of EO, and defines an "entrepreneurial firm as one that engages in product marketing innovation, undertakes somewhat risky ventures, and is first to come up with proactive innovations, beating competitors to the punch". After Miller (1983), Covin & Slevin(1989) adopted EO as a uni-dimensional construct, and insisted that these three dimensions can be combined into a single scale. Since Covin & Slevin(1991), researchers including Lumpkin & Dess(1996) have explored the usefulness of EO. However not many attempts have been tried to summarize the results of previous empirical researches, and to suggest future research directions. To examine and find implications, current study classified the effects of EO as 1) main and mediating effects, 2) moderating effect, 3) other effects, and provide theoretical and empirical validation of EO, which suggested by Miller(2011). After analyzing research results published in major international and Korean journals in each research domain, current paper summarizes and evaluates previous research results, and then suggests research directions for the future. In doing so, we hope to provide some theoretical and practical insight for management of small and medium sized firms.

  • PDF

A Study on the Classification of Constructed-Response Items in Geography Education: In Case of 4th Grade Items of the NAEP (지리과 서답형 문항의 주요 유형에 관한 연구 -NAEP의 지리과 4학년 문항을 사례로-)

  • Jang, Eui-Sun
    • Journal of the Korean Geographical Society
    • /
    • v.47 no.6
    • /
    • pp.934-954
    • /
    • 2012
  • Constructed-response items are useful to estimate a higher-order thinking abilities such as sense of place, graphicacy, and geographical imaginations which are aimed by geography education. This study aims to identify the conception of the constructed-response items, to classify those feasible items in geography education, and to propose some comments and suggestions for development and application in Korea. The author tries to classify the constructed-response items by analyzing the NAEP items in the formal aspect and the aspect of cognitive dimension respectively. In the formal aspect, they are classified as 'question-standalone' type and 'material-presenting' type. In the aspect of cognitive dimension, they are classified into three types as 'knowledge-requirement', 'understanding-requirement', and 'applying-requirement'. Some comments and suggestions are as follows. First, it is necessary to develope the constructed-response items that coherent to both content and cognitive dimensions. Second, it is required for students who take an examination to use a great variety of graphics, photos, thematic maps related to geography. Third, we need to inquire the rubric, grade, process to scoring because they are vital to success of the constructed-response items.

  • PDF

The First Photometric Study of NSVS 1461538: A New W-subtype Contact Binary with a Low Mass Ratio and Moderate Fill-out Factor

  • Kim, Hyoun-Woo;Kim, Chun-Hwey;Song, Mi-Hwa;Jeong, Min-Ji;Kim, Hye-Young
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.185-196
    • /
    • 2016
  • New multiband BVRI light curves of NSVS 1461538 were obtained as a byproduct during the photometric observations of our program star PV Cas for three years from 2011 to 2013. The light curves indicate characteristics of a typical W-subtype W UMa eclipsing system, displaying a flat bottom at primary eclipse and the O'Connell effect, rather than those of an Algol/b Lyrae eclipsing variable classified by the northern sky variability survey (NSVS). A total of 35 times of minimum lights were determined from our observations (20 timings) and the SuperWASP measurements (15 ones). A period study with all the timings shows that the orbital period may vary in a sinusoidal manner with a period of about 5.6 yr and a small semi-amplitude of about 0.008 day. The cyclical period variation can be interpreted as a light-time effect due to a tertiary body with a minimum mass of 0.71 M. Simultaneous analysis of the multiband light curves using the 2003 version of the Wilson-Devinney binary model shows that NSVS 1461538 is a genuine W-subtype W UMa contact binary with the hotter primary component being less massive and the system shows a low mass ratio of q(mc/mh)=3.51, a high orbital inclination of 88.7°, a moderate fill-out factor of 30 %, and a temperature difference of ΔT=412 K. The O'Connell effect can be similarly explained by cool spots on either the hotter primary star or the cool secondary star. A small third-light corresponding to about 5 % and 2 % of the total systemic light in the B and V bandpasses, respectively, supports the third-body hypothesis proposed by the period study. Preliminary absolute dimensions of the system were derived and used to look into its evolutionary status with other W UMa binaries in the mass-radius and mass-luminosity diagrams. A possible evolution scenario of the system was also discussed in the context of the mass vs mass ratio diagram.

Anthropometric Analysis of the Mouth in Koreans (한국인 입에 대한 생체계측학적 연구)

  • Kim, Soon Heum;Kim, Na Yeon;Lee, Soo Hyang;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il;Lee, Jeong Yong;Song, Wu Chul;Koh, Ki Seok
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.139-146
    • /
    • 2008
  • Purpose: The objective of this study is anthropometric analysis of mouth and lower face of Korean. The relationship of soft-tissue to underlying bony structures determine the overall aesthetics of the face. The goal of aesthetic surgery of the face is to achieve the ideal normal and enhance the aging face. The purpose of present study was to determine the change of the morphology of the mouth and lower face based on soft-tissue landmarks according to age group to facilitate prediction during aesthetic surgery. Methods: The standardized photographs of 2,018 healthy volunteers(18 to 79 years of age; 1,070 males, 948 females) were investigated. Age groups were classified into young, middle-aged, and elderly groups. Five and seven items were measured on frontal and lateral view photographs, respectively. Individual dimensions were compared in the three age groups and between males and females. Results: The width of mouth is 4.5 times larger than that of philtrum. Most of measured data decreased with age. However, woman's lip width of the mouth somewhat increased from the young to elderly. The width of lower face is 2.5 times larger than mouth in young age group and increased slightly from the young to middle-aged and thereafter slightly decreased to elderly group. Upper lip was more higher than lower lip and male lip was more higher than female. But male and female lip height is similar at old age. Conclusion: Most of Koreans showed prominent lower face because of the development or protrusion of the mandible. And the descent of soft-tissue around the mouth was one of the significant characteristics of senile change. The posterior retrusion of the subnasal was an another characteristic. This study will help to elucidate the age-related dimensional differences of the human being and to provide useful information for clinical applications in oral and aesthetic surgery.

The Effect of the Plasma Treatment on PLGA Scaffold for Adhesion and Chondrogenic Differentiation of Human Adipose-derived Stromal Cells (인체지방유래 간질세포의 부착 및 연골분화유도를 위한 PLGA 지지체의 플라즈마 처리 효과)

  • Dong, Chun Ji;Jun, Young Joon;Cho, Hyun Mi;Oh, Deuk Young;Han, Dong Keun;Rhie, Jong Won;Ahn, Sang Tae
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.46-52
    • /
    • 2006
  • High-density micromass culture was needed to take three dimensions culture with ASCs(adipose derived stromal cells) and chondrogenesis. However, the synthetic polymer has hydrophobic character and low affinity to cells and other biomolecules. Therefore, the surface modification without changes of physical and chemical properties is necessary for more suitable condition to cells and biomolecules. This study was performed to investigate the effect of surface modification of poly (lactic-co-glycolic acid)(PLGA) scaffold by plasma treatment (P(+)) on the adhesion, proliferation and chondrogenesis of ASCs, and not plasma treatment (P(-)). ASCs were isolated from human subcutaneous adipose tissue obtained by lipectomy and liposuction. At 1 hour 30 minutes and 3days after cell seeding onto the P(-) group and the P(+) group, total DNA amount of attached and proliferated ASCs markedly increased in the P(+) group (p < 0.05). The changes of the actin under confocal microscope were done for evaluation of cellular affinity, at 1 hour 30 minutes, the shape of the cells was spherical form in all group. At 3rd day, the shape of the cells was fiber network form and finely arranged in P(+) group rather than in P(-) group. RT-PCR analysis of cartilage-specific type II collagen and link protein were expressed in 1, 2 weeks of induction. Amount of Glycoaminoglycan (GAG) markedly increased in P(+) group(p < 0.05). In a week, extracellular matrix was not observed in the Alcian blue and Safranin O staining. However in 2 weeks, it was observed that sulfated proteoglycan increased in P(+) group rather than in P(-) group. In conclusion, we recognized that plasma treatment of PLGA scaffold could increase the hydrophilic property of cells, and provide suitable environment for high-density micromass culture to chondrogenesis

The Last Phase of Life.Life Completion.Palliative Care Model (생의 마지막 단계.삶의 완결.완화간호 모델)

  • Kim, Dal-Sook
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.3
    • /
    • pp.115-121
    • /
    • 2009
  • Despite a recent increased nation's attention given to improving end-life care, we professionals need to be more critical and reflective on our realities surrounding hospice palliative care. The aim of this paper is to suggest that palliative care models can be used for patients/families in the last phase of life and examine whether they are appropriate for caring them in congruence with philosophy of hospice. The hospice experience model (HEM) of Eagan & Labyak and the developmental model of Byock are introduced and examined for their congruence with philosophy of hospice in applying to clinical practice. The HEM as a patient/family value-directed end of life care model emphasizes three principles; unique experience of patient/family, interactions/relationships among multiple dimensions of personhood and between family, and personal growth and development in the face of suffering through a life-completion. The developmental model stipulates dying as the last stage of living, a stage of life cycle in which patients/family may have growth through life-completion in multidimensional relationships of personhood. The model includes the developmental landmarks and tasks for life-completion as the framework to guide a means of professionals' to recognize their opportunity to grow. The landmarks and tasks include worldly and social affair, individual relationships, intrapersonal, and transcendent dimension. The models could work as appropriate palliative care models for patients/families in the last stage of living. The professionals need to be encouraged to apply the models to end of life care setting.

  • PDF

Deformation Monitoring of a Structure Using Kinematic GPS Surveying Technology (Kinematic GPS 측량기법에 의한 구조물의 변형 모니터링)

  • 이진덕
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.16 no.1
    • /
    • pp.27-40
    • /
    • 1998
  • This paper addresses the suitability of GPS positioning technology to monitoring deformation and movement of structures. The first part of the study is an empirical quantitative study of the repeatability of GPS observations and the second part is a performance evaluation of kinematic GPS, which requires only a few minutes per a point, for monitoring deformation of an engineering structure. On the test network for monitoring of a earth am, four observations have been conducted repeatedly on different seasons and water levels. The reference network was observed in static mode, and monitoring points were observed respectively in rapid-static mode as well as in kinematic mode in each epoch and then the results were compared with those obtained by conventional surveying techniques. The repeatability of baseline vectors to better than average 7 mm in three dimensions was achieved in base line observations between reference points and also the unclosure of reference networks showed the range of 4 ppm to 27 ppm. Compared with conventional surveying techniques, the kinematic approach showed the differences of 3∼4 m in slope distances which were observed from reference points to monitoring points, and showed the differences of 4∼8 m in height. It was ascertained that the kinematic GPS technology provides an efficient alternative to deformation monitoring by conventional means which are capable of detecting movements in the order of 5 mm.

  • PDF