• Title/Summary/Keyword: three-dimensional measuring instrument

Search Result 18, Processing Time 0.022 seconds

Product's quality improvement plane of parts for Injection Molding using Axiomatic approach (공리적 기법에 의한 품질 향상 방안)

  • Bae J.W.;Park H.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.355-356
    • /
    • 2006
  • This paper proposes an Molding error compensation method that improves accuracy with geometry information of injected parts using three-dimensional measuring instrument. a traditional mold design has been conducted by an experience-based trial and error, whereby generally the mold designer would decide the gate location and processing conditions. as a natural consequence, almost all creats inferior goods. It's just a process of trial and error and caught in a vicious circle. Due to this reason, this paper uses a three-dimensional measuring instrument, a commercial analysis package of injection molding(Moldflow, MPI) to analysis a state of flux. In addition to that axiomatic approach.

  • PDF

Developemet of noncontact velocity tracking algorithm for 3-dimensional high speed flows using digital image processing technique (디지털 화상처리를 이용한 유동장의 비접촉 3차원 고속류 계측법의 개발)

  • 도덕희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.259-269
    • /
    • 1999
  • A new algorithm for measuring 3-D velocity components of high speed flows were developed using a digital image processing technique. The measuring system consists of three CCD cameras an optical instrument called AOM a digital image grabber and a host computer. The images of mov-ing particles arranged spatially on a rotation plate are taken by two or three CCD cameras and are recorderd onto the image grabber or a video tape recoder. The three-dimensionl velocity com-ponents of the particles are automatically obtained by the developed algorithm In order to verify the validity of this technique three-dimensional velocity data sets obtained from a computer simu-lation of a backward facing step flow were used as test data for the algorithm. an uncertainty analysis associated with the present algorithm is systematically evaluated, The present technique is proved to be used as a tookl for the measurement of unsteady three-dimensional fluid flows.

  • PDF

Comparison of polymerization by time of light curing for dental 3D printing (치과 3D 프린팅용 광중합 시간에 따른 중합도 비교)

  • Kim, Dong-Yeon;Lee, Gwang-Young
    • Journal of Technologic Dentistry
    • /
    • v.44 no.3
    • /
    • pp.76-80
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the depth according to curing using photocurable resin for dental three-dimensional printing. Methods: A stainless mold with a height of 4 mm was prepared. Ultraviolet (UV) polymerization resin was injected into the mold. Photocuring was then performed for 5 minutes using a photopolymerizer, and the height was measured using a digital measuring instrument (first group). Second, light polymerization was also performed outside the mold for 5 minutes, and the height was measured using a digital measuring instrument. Third, light polymerization was further performed for 5 minutes, and the height was measured using a digital measuring instrument. Statistical analysis was performed with the Kruskal-Wallis test, which is a nonparametric test (α=0.05). Results: The third group had the largest measurement length, whereas the first group had the smallest. However, the difference between groups was not statistically significant (p>0.05). The color of the first group was different from that of the second and third groups. Conclusion: All of the 4-mm-thick photocured specimens had a curing reaction, but the part that was not directly irradiated with UV did not show its original color.

Development of 3 - Dimensional Ultrasonic Wind Direction Anemometer Measurement Technique Using Time Division Method (시분할 방식을 이용한 3차원 초음파 풍향풍속계 측정기술 개발)

  • Lee, Woo-Jin;Choi, Jae-Young;Kim, Kyung-Won;Yim, Jae-Hong
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.1
    • /
    • pp.66-72
    • /
    • 2017
  • The three dimensional ultrasonic anemometer was constructed to reduce the disadvantages of the two-dimensional anemometer and to be free from the use environment. Three pairs of transmitting and receiving ultrasonic sensors were designed to face each other at an angle of $45^{\circ}$ to the upper and lower surfaces at intervals of $120^{\circ}$. 200 kHz ultrasonic sensor Oscillation, transmission and reception, level detection, power supply circuit were designed and U, V, W wind speed vector components were obtained by measuring the time of first received ultrasonic pulse by transmitting pulse ultrasound. It is implemented as firmware in ARM Coretex-M3 processor so that horizontal and vertical wind direction and wind speed can be converted into digital signal by vector calculation. In this study, The three-dimensional ultrasonic anemometer can complement the disadvantages of the two-dimensional anemometer (mechanical and ultrasonic), and it is expected to gradually replace the two-dimensional anemometer due to its high utilization rate by collecting additional information such as vertical wind.

An Experimental Study on the Flow Pattern in the Vicinity of Pressure Measuring Hole of the Viscoelasitc Fluids (점탄성유체의 압력측정용 벽공부근의 유동모양에 관한 실험적 연구)

  • 김춘식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.4 no.1
    • /
    • pp.23-31
    • /
    • 1980
  • The fluid static pressure has been generally measured by means of a small hole leading to a measuring instrument. In case of viscoelastic fluids, however, it has been shown experimentally that a systematic error exists in measuring the static pressure by means of the small hole becuase viscoelasitc fluids have many properties that can not be observed in Newtonian fluids. In this paper, in order to examine the mechanism of the errors in measuring the static pressure of viscoelasitc fluids, flow patterns in the vicinity of static pressure measuring hole were photographically taken and observed graphically. The experiments to take photographs of flow patterns were performed by a parallel plate channel with the steady two-dimensional shear flow of viscoelastic fluids. Results of the experiment are classified as following three regions; (1) Arched symmetrical flow pattern region. (2) Asymmetrical flow pattern region. (3) Rectilinear symmetricl flow pattern region.

  • PDF

Measuring Perceived Depth For The Object Using 3D Content Depth Measuring Instrument (3D 콘텐츠 깊이 측정기를 이용한 오브젝트의 돌출거리 측정)

  • Han, Dong-Hee;Kang, Hang-Bong;Ki, Seok-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.9
    • /
    • pp.1109-1118
    • /
    • 2013
  • Recently, stereoscopic three-dimensional(S3D) movie and video are becoming globally popular. However, there are some people who could not perceive 3D depth information well. Traditional stereopsia test tools could not analyze the subject's perceived depth accurately. Therefore, it is necessary to have a test tool that accurately measures the degree of perceived depth of subjects. In this paper, we suggested a 3D content depth measuring instrument and produced suitable 3D contents for the instrument. We measured subjects' perceived depth of 3D foreground objects in terms of $+1^{\circ}$, $-1^{\circ}$, $-2^{\circ}$ binocular disparity and compared the measured values with the theoretical values. Measured values were slightly bigger than the theoretical values. Deviation between the measured values and theoretical values increased with extrusion distances.

Improvement in Productivity of Engine Clutch Female Flanges for Tank (전차용 엔진클러치 암플랜지 생산성 향상을 위한 연구)

  • Kim, Joong-Seon;Kwon, Dae-Kyu;Lee, Se-Han;Wang, Duck-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.3
    • /
    • pp.56-62
    • /
    • 2022
  • The tank engine clutch flange constitutes a tank on which the engine and transmission of the tank are mounted. The engine clutch flange is fabricated using a difficult-to-cut material that exhibits high strength and hardness. It is difficult to process and requires considerable processing expertise. In addition, the engine clutch flange for the tank requires high machining precision because it is a system in which the connection is detachable. Because it requires high processing precision, the measurement of products equally important as processing. However, productivity is low owing to the significant amount of time required to measure each product using a three-dimensional coordinate measuring machine. Hence, this study is conducted to improve the productivity of the female tank engine clutch flange. Dedicated hobs and jigs are designed and manufactured to convert the existing end-mill cutting processing into hobbing cutting processing. An engine clutch for the tanks is manufactured using the manufactured dedicated hob and jig, and the shortening time is verified by measuring the processing time. In addition, a jig for inspection is designed and manufactured to measure the precision of the product. To verify the inspected product, the product precision is measured using a contact-type three-dimensional coordinate measuring machine and a surface roughness measuring instrument. The study confirmed that the productivity of the engine clutch flange product for tanks can be improved by simplifying the process, reducing the processing time, and simplifying product inspection.

Roughness Measurement of Hole Processing Surface for Mold Steel Using White Light Interferometer (백색광간섭계를 이용한 금형용 강재 구멍가공면의 조도 측정)

  • Lee, Seung-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.73-79
    • /
    • 2013
  • In this study, NIMAX material has been processed using the three-dimensional measuring instrument and white light interferometer. they were tested to roundness and surface roughness and results are as follows: As for a cutting characteristic, it indicated that F4 showed a lower result than 2F showed due to the high hardness of the material and showed a good result when spindle rotation speed and tool feed were low. As for the measurement of roundness through 3-Dimensional measuring machine, it indicated that 4F showed a good result like the condition of cutting component and that roundness showed a good result when spindle rotation speed of 1,700 rpm and tool feed speed of 85 mm/min were applied. As for the surface roughness of processing surface, Surface roughness showed better 4F than 2F and conditions of spindle rotation speed 1,700 rpm, tool feed rate 55 mm/min showed good results in the Ra $0.4025{\mu}m$.

Position Detection Algorithms Using 3-Axial Accelerometer Sensor (3축 가속도 센서를 이용한 위치 검출 알고리즘)

  • Kim, Nam-Jin;Choi, Young-Hee;Choi, Lee-Kwon
    • Journal of Information Technology Services
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2011
  • In this paper, we consist of three dimensional acceleration sensor as a small-sized sensor module to acquire base technologies that need to estimate exhibition audience' moving distance. and that we developed algorism and device that can calculate acceleration in gravity direction with attaching it to people's body part without regard to three dimensional direction. By making use of the sensor module, we have to process the data that let it quantitatively process possible to measure people's walk and movement by computer system. We normalized sensor output data in the process of change from sensor module to acquisition of data, rectangular coordinates and single scalar acceleration value in gravity direction. Printed out sensor data attaching sensor module to people's body part is used for motion pattern detection after normalization, Motion sensor devised mode change algorism because it print data of other pattern according to attached position of body. For algorism design, we collected data occurring during walking about subject and we also defined occurring problem domain after analyzing the data. We settle defined problem domain and that we simulated the walking number measuring instrument with highly efficient in restricted environment.

Development and Evaluation of the Reliability and Validity of the VSSS-82 Korean Version for Measuring Satisfaction with Community-based Mental Health Services in Psychiatric Patients (지역사회정신보건서비스 이용자의 만족도 측정을 위한 한국어판 Verona Service Satisfaction Scale-82 (VSSS-82)의 개발 및 신뢰도와 타당도 평가)

  • Yoo, Weon-Seob;Moon, Ok-Ryun;Nam, Jung-Hyun;Shin, Young-Jeon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.34 no.3
    • /
    • pp.211-218
    • /
    • 2001
  • Objectives : To develop a Korean version of VSSS-82 for measuring the multi-dimensional satisfaction with community-based mental health services in psychiatric patients and to investigate both the reliability and validity of the Korean version. Methods : The VSSS-82 English version was translated and back-translated with some modification. Data from 68 psychosis patients using community-based mental health services in three Community Mental Health Centers (CMHCs) was collected through a personal interview survey regarding the satisfaction and suitability of service. Variability of satisfaction and internal consistency, discriminant validity, and concurrent validity of the VSSS-82 Korean version were evaluated. Results : A higher number of dissatisfied subjects and significant pairwise differences for the dimensions were found. The Crohnbach's alpha coefficient, a measure of internal consistency, ranged from 0.56(overall satisfaction) to 0.90(skills and behavior) and significant differences in satisfaction was found in patients by the self-rated suitability of service. Conclusions : The VSSS-82 Korean version is a reliable and valid instrument for measuring multi-dimensional satisfaction with community-based mental health service.

  • PDF