• 제목/요약/키워드: three phase ratio

검색결과 493건 처리시간 0.027초

3상 PWM AC-AC 부스트 컨버터의 DSP 기반 전류 프로그램 제어 (DSP-based Current Programmed Control of Three Phase PWM AC-AC Boost Converter)

  • 최남섭;이옥룡
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권1호
    • /
    • pp.27-32
    • /
    • 2006
  • In this paper, a new scheme of current programmed control for three phase PWM AC-AC converter is presented. Compared to duty-ratio voltage control, current programmed control has several advantages such as reduction of system order, inherent current protection and robust output. By considering only the magnitude components, a similar scheme in the DC-DC converter can be extended to the three phase PWM AC-AC converter. The proposed current programmed control will be well adopted into various converter topologies though three phase PWM AC-AC boost converter is treated as an example. The converter analysis is carried out by applying the vector DQ transformation to obtain physical insight into the converter operation and to establish some important characteristic equations for control purpose. The experiment results show the validity of the proposed scheme.

스케일 변화에 따른 NREL PHASE VI 풍력터빈의 성능해석 (PERFORMANCE ANALYSIS OF NREL PHASE VI WIND TURBINES UNDER VARIOUS SCALE CONDITIONS)

  • 박영민;장병희
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.155-158
    • /
    • 2006
  • In the present paper, the scale effects of two-dimensional airfoil and three-dimensional wind turbine were investigated by using FLUENT software. For two dimensional analysis, flow around S809 airfoil with various Reynolds No. and Mach No. conditions were simulated. For three dimensional analysis, scaled NREL Phase VI wind turbine models from 6% to 1,600% were simulated under the same tip speed ratio condition. Finally, aerodynamic comparisons between two-dimensional flow and three dimensional wind turbine flow are made for the feasibility study of scale effect corrections. Currently, KARI(Korea Aerospace Research Institute) is preparing for the wind tunnel test of 12% NREL Phase VI wind turbine and the performance analysis of the scaled NREL wind turbine model will be validated by the wind tunnel test.

  • PDF

단위 역률을 갖는 직접 시비율 변조방식 3상 매트릭스 컨버터의 제어 및 동작 특성 (Control and Operating Characteristics of Three-Phase Matrix Converter with Unity Power Factor by Direct Duty-Ratio Modulation Method)

  • 이옥룡;최남섭;한병문
    • 전력전자학회논문지
    • /
    • 제14권2호
    • /
    • pp.142-149
    • /
    • 2009
  • 본 논문은 단위 역률을 갖도록 직접 시비율 펄스폭 변조 방식으로 제어되는 3상 매트릭스 컨버터의 평형 및 불평형 부하시의 동작 특성을 고찰한다. 시스템의 해석으로부터 얻어진 중요하고 유용한 사실을 정리하면 다음과 같다. (1) 단위 역률 제어 알고리즘은 부하측의 변수에 의해서가 아니라 입력전압에 의하여 정해진다. (2) 평형 3상 부하가 리액티브 부하인 경우만 아니라면 입력측 역률을 1로 만들 수 있다. (3) 불평형 선형부하의 경우, 매트릭스 컨버터의 등가입력 특성은 비선형저항과 같다. (4) 입력 주파수와 출력 주파수가 특정한 관계를 가질 때, 입력측의 각상은 동일한 평균전력 분담률을 갖는다. 해석의 타당성과 유효성은 시뮬레이션과 실험결과를 통하여 검증하였다.

삼상일체화된 자속구속형 SFCL의 사고종류에 따른 소자들의 퀜치 특성 (Quench Characteristics of HTSC Elements according to fault types in Integrated Three-Phase)

  • 박충렬;이종화;박식;두호익;임성훈;최효상;한병성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.960-962
    • /
    • 2005
  • In this paper, we investigated the quench characteristics of high-Tc superconducting(HTSC) elements in the integrated three-phase flux-lock type superconducting fault current limiter(SFCL) according to fault types such as the single-line-to-ground fault, the double-line-to-ground fault, the line-to-line fault and the triple-line-to-ground fault. The integrated three-phase flux-lock type SFCL is an upgrade version of single-phase flux-lock type SFCL. The structure of the integrated three-phase flux-lock type SFCL consisted of a three-phase flux-lock reactor wound on an iron core with the ratio of the same turn between coil 1 and coil 2 in each phase. When the SFCL is under the normal condition, the flux generated in the iron core is zero because the flux generated between two coils of each single phase is canceled out. Therefore, the SFCL's impedance is zero, and the SFCL has negligible influence on the power system. However, if a fault occurs in any single one of three phases, the flux generated in the iron core is not zero any more. The flux makes HTSC elements of all phases to quench irrespective of the fault type, which reduces the current in fault phase as well as the current of sound phase. It was obtained that the fault current limiting characteristics of the suggested SFCL were dependent on the quench characteristics of HTSC elements in all three phases.

  • PDF

Comparison of PWM Strategies for Three-Phase Current-fed DC/DC Converters

  • Cha, Han-Ju;Choi, Soon-Ho;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제8권4호
    • /
    • pp.363-370
    • /
    • 2008
  • In this paper, three kinds of PWM strategies for a three-phase current-fed dc/dc converter are proposed and compared in terms of losses and voltage transfer ratio. Each PWM strategy is described graphically and their switching losses are analyzed. With the proposed PWM C strategy, one turn-off switching of each bridge switch is eliminated to reduce switching losses under the same switching frequency. In addition, RMS current through the bridge switches is lowered by using parallel connection between two bridge switches and thus, conduction losses of the switches are reduced. Further, copper losses of the transformer are decreased due to the reduced RMS current of each transformer's winding. Therefore, total losses are minimized and the efficiency of the converter is improved by using the proposed PWM C strategy. Digital signal processor (DSP: TI320LF2407) and a field-programmable gate array (FPGA: EPM7128) board are used to generate PWM patterns for three-phase bridge and clamp MOSFETs. A 500W prototype converter is built and its experimental results verify the validity of the proposed PWM strategies.

정류방식에 따른 진단용 X-선 장치의 출력비교 (A Comparative Study on Output of Four Type Diagnostic X-ray Equipments)

  • 김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF

가변속 구동을 위한 단상 유도전동기의 벡터제어 (Vector Control of Single Phase Induction Motor for Variable Speed Drive)

  • 이득기;이경주;정종진;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1260-1263
    • /
    • 2000
  • Vector control of a single phase induction machine(SPIM) is usually employed by mechanical methods than electrical ones. The disadvantage of a SPIM has large noise at the starting. Using auxiliary winding which is only utilized for starting, the SPIM can be controlled with the vector control method. Regarding a auxiliary winding one phase, the SPIM is analyzed by the unsymmetrical two phase motor and phase transformation is unnecessary such as three phase IM. Including a auxiliary winding, SPIM is modeled by mathematical getting by component of turns ratio with main to auxiliary winding. It will be take with complicated resultant formula, by comparison to symmetrical three phase TM. For using the vector control theory, it must be decoupled of rotor flux and torque component. stator current is controlled and decoupled. This paper presents a variable-speed control system of SPIM, which to decoupled with flux and torque component and to use machine equivalent circuit referred to rotor, conventionally three phase IM by similar method.

  • PDF

쇄교자속비를 이용한 변압기 보호 알고리즘 (A Transformer protective Relaying Algorithm Based on Increment of Flux Linkages)

  • 강용철;이병은;김은숙;원성호;임의재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.53-55
    • /
    • 2003
  • This paper propose a transformer protective relaying algorithm based on the increment of flux linkages (RIFL) of the Primary and secondary windings. The RIFL is equal to the turn ratio for all operating conditions except an internal faults. For a single-phase transformer and three-phase Y-Y transformer, the increments of flux linkages are calculated and their ratios are compared with the turn ratio. For a three-phase Y-$\triangle$ transformer, the difference of the increments of flux linkages are calculated to use the line currents instead of the delta winding currents, which are practically unavailable. Their ratios are compared with the turn ratio. The results of various tests show that the algorithm successfully discriminates internal faults from normal operation conditions such as magnetic inrush and overexcitation. The algorithm can not only detect internal winding faults, but reduce the relay's operating time.

  • PDF

비점성 정체 유동 응고 문제에 대한 이론적 해석 (A theoretical analysis on the inviscid stagnation-flow solidification problem)

  • 유주식
    • 설비공학논문집
    • /
    • 제12권1호
    • /
    • pp.1-11
    • /
    • 2000
  • This study investigates the problem of phase change from liquid to solid in the inviscid stagnation flow. The solution of dimensionless governing equations is determined by the three dimensionless parameters of (temperature ratio/conductivity ratio), Stefan number, and diffusi-vity ratio. The solution at the initial stage of freezing is obtained by expanding it in powers of time, and the final equilibrium state is determined from the steady-state governing equations. The equilibrium state is dependent on (temperature ratio/conductivity ratio), but is independent of Stefan number and diffusivity ratio. The effect of fluid flow on the pure conduction problem can be clearly seen from the solution of the initial stage and the final equilibrium state, and the characteristics of the solidification process for all the dimensionless parameters are elucidated.

  • PDF

다중 3상 PWM 정류기의 해석 (The Analysis of The Three Phase Rectifier)

  • 신대호;윤경섭;조정구;권우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.242-245
    • /
    • 1995
  • In this paper the multiple three rectifiers for the power factor correction are proposed, analyzed and designed. The multiple three phase rectifiers draw sinusoidal ac currents from the ac voltage sources with nearly unity input power factor and operate with PWM making the control circuit simple and system cost low. Outstandingly it reduces the rated power capacity of devices and the input filter size by reducing input current ripples. Moreover design rules can be obtained from input and output current equations. With the proposed rules, input power factor and output power capacity are determined approximately. Finally these design rules are verified with computer simulations.

  • PDF