• 제목/요약/키워드: three phase ratio

검색결과 497건 처리시간 0.036초

A semi-analytical study for vibration analysis of damaged core laminated cylindrical shell with functionally graded CNTs reinforced face sheets resting on a two-parameter elastic foundation

  • Aseel J. Mohammed;Bassam A. Mohammed;Hatam K. Kadhom;Anmar Ghanim Taki;Vahid Tahouneh
    • Advances in nano research
    • /
    • 제17권4호
    • /
    • pp.301-313
    • /
    • 2024
  • The main objective of this paper is to study vibration of sandwich cylindrical shell with damaged core and FG face sheets resting on a two-parameter elastic foundation based on three-dimensional theory of elasticity. Three complicated equations of motion for the structure under consideration are semi-analytically solved by using generalized differential quadrature method. The structures are made of a damaged isotropic core and two external face sheets. These skins are strengthened at the nanoscale level by randomly oriented Carbon nanotubes (CNTs) and are reinforced at the microscale stage by oriented straight fibers. These reinforcing phases are included in a polymer matrix and a three-phase approach based on the Eshelby-Mori-Tanaka scheme and on the Halpin-Tsai approach, which is developed to compute the overall mechanical properties of the composite material. Several parametric analyses are carried out to investigate the mechanical behavior of these multi-layered structures depending on the damage features. A detailed parametric study is carried out in order to reveal the effects of different profiles of two-parameter elastic foundation modulus, different geometrical parameters such as the mid radius-to-thickness ratio, length-to-mean radius ratio and the thickness of face sheets on the vibrational characteristics of the damaged functionally graded sandwich cylindrical shell.

대용량 및 높은 입력전압에 적합한 새로운 Three Level DC/DC 컨버터 (A Novel Three Level DC/DC Converter for High power applications operating from High Input Voltage)

  • 한상규;오원식;문건우;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.317-322
    • /
    • 2003
  • A novel three-level DC/DC converter (TLC)for high power applications operating from high input voltage Is proposed. Its switch voltage stress can be ensured to be only one-half of the Input voltage. Nevertheless, since all input voltage is applied to the transformer primary side, it has good turns ratio. The driving method of each module is same as those of the conventional phase-shifted ZVS full bridge PWM converter (PSFB) and the zero-voltage-switching (ZVS) of the leading leg are achieved exactly in the same manner as that of the PSFB. Moreover, its three-level operation can considerably reduce the current ripple through the output inductor and it has no problems of the DC-link voltage unbalance. Therefore, it features a low voltage stress, high efficiency, low EMI, high power density, and small sized filter. To confirm the operation, validity, and features of the proposed circuit, experimental results from a 200W, 600V/DC-48V/DC prototype are presented.

  • PDF

Phytobiotics and Organic Acids As Potential Alternatives to the Use of Antibiotics in Nursery Pig Diets

  • Kommera, S.K.;Mateo, R.D.;Neher, F.J.;Kim, S.W.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제19권12호
    • /
    • pp.1784-1789
    • /
    • 2006
  • Two experiments were conducted to determine the effect of phytobiotics and organic acids on growth performance of nursery pigs as an alternative to antibiotics. Phytobiotics refer bioactive compounds from plant materials including essential oils and herbal extracts. In Exp. 1,144 pigs, weaned at 23.4${\pm}$0.3 d age, were allotted to three dietary treatments. Treatment diets were: 1) NC (no antibiotics and no phytobiotics); 2) PC (NC+carbadox, 50 mg/kg); and 3) PB (NC+phytobiotics; 0.1% PEP1000-$1^{(R)}$. Each treatment had six replicates with eight pigs per pen. Pigs were fed the experimental diets for 5 wks in 3 phases (phase 1 for 2 wk; phase 2 for 2 wk; phase 3 for 1 wk). In Exp. 2, 192 pigs, weaned at 19.2${\pm}$0.3 d age, were allotted to three dietary treatments: 1) NC; 2) PC; and 3) PBO (NC+phytobiotics; 0.2% or 0.1% PEP1000-$1^{(R)}$ and organic acids; 0.4% or 0.2% $Biotronic^{(R)}$for the phase 1 and 2, respectively) with eight replicates per treatment and eight pigs per pen. Pigs were fed the assigned diets for 5 wks in 2 phases (phase 1 for 2 wk; phase 2 for 3 wk). Body weights were measured at the beginning of the experiment and at the end of each week in both Exp. 1 and 2. Feed intake was measured at the end of each week in both Exp. 1 and 2. Diarrhea score was measured daily during the entire period for Exp. 1 and during the phase 1 for Exp. 2. In Exp. 1, the PC had a higher (p<0.05) overall ADG than the NC, but the overall ADG of the PB did not differ (p>0.05) from the NC or the PC. In Exp. 2, the overall ADG did not differ (p>0.05) among all the treatments during the entire experimental period. The overall ADFI and the overall gain:feed ratio did not differ (p>0.05) among all the treatments during the entire experimental period in both Exp. 1 and 2. The PC had a higher (p<0.05) overall diarrhea score (harder stools) than the NC and the PB in Exp. 1, and a higher (p<0.05) overall diarrhea score than the NC in Exp. 2. The overall diarrhea score of the PB and the PBO did not differ (p>0.05) from the NC or the PC in Exp. 1 and 2. Results from this study show that the growth of pigs fed the diets with phytobiotics or the combination of phytobiotics and organic acids did not differ from those both with antibiotics and without antibiotics when tested in an environmentally controlled research facility. Further experiments are required to study the growth performance in disease challenged conditions.

삼상 분리형 자속커플링 전류제한기의 턴 수의 따른 전류제한 특성 (Characteristics according to turn ratio of Separated Three-Phase Flux-Coupling Type Superconducting Fault Current Limiter(SFCL))

  • 김용진;두호익;두승규;김민주;이동혁;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.344-345
    • /
    • 2009
  • The flux-coupling type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In a normal condition, the flux generated from a primary coil is cancelled out by its structure and the zero resistance of the YBCO thin films. When a fault occurs, the resistance of the YBCO coated conductor was generated and the fault current was limited by the SFCL. In this paper, we investigated the fault current limiting characteristics according to turn ratio in the flux-coupling type SFCL. The experiment results that the fault current limiting characteristics was improved according to turn ratio.

  • PDF

열원 냉각용 루프 써모사이폰의 작동 특성 (Performance Characteristics of a Loop Thermosyphon for Heat Source Cooling)

  • 최두성;송태호
    • 대한기계학회논문집B
    • /
    • 제28권12호
    • /
    • pp.1475-1483
    • /
    • 2004
  • Loop thermosyphon(LTS) has many good characteristics such as low thermal resistance, no power consumption, noiseless operation and small size. To investigate the overall performance of LTS, we have performed various experiments varying three parameters: input power of the heater, working fluid(water, ethanol, FC3283) and filling ratio of the working fluid. At a combination of these parameters, temperature measurements are made at many locations of the LTS. The temperature difference between the evaporator and the condenser is used to obtain the thermal resistance. In addition, flow visualization using a high speed camera is carried out. The thermal resistance is not constant. It is lower at higher input power, which is one of the distinct merits of LTS. Flow instabilities are frequently observed when changing the working fluid, the input power and the filling ratio. The results show that the LTS can be readily put into practical use. Future practical application in electronic cooling is recommended.

발전소 굴뚝에서의 입자 분산에 대한 수치해석 (Numerical study of particle dispersion from a power plant chimney)

  • 심정보;유동현
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.173-182
    • /
    • 2017
  • An Eulerian-Lagrangin approach is used to compute particle dispersion from a power plant chimney. For air flow, three-dimensional incompressible filtered Navier-Stokes equations are solved with a subgrid-scale model by integrating the Newton's equation, while the dispersed phase is solved in a Lagrangian framework. The velocity ratios between crossflow and a jet of 0.455 and 0.727 are considered. Flow fields and particle distribution of both cases are evaluated and compared. When the velocity ratio is 0.455, it demonstrates a Kelvin-Helmholtz vortex structure above the chimney caused by the interaction between crossflow and a jet, whereas the other case shows flow structures at the top of the chimney collapsed by fast crossflow. Also, complex wake structures cause different particle distributions behind the chimney. The case with the velocity ratio of 0.727 demonstrates strong particle concentration at the vortical region, whereas the case with the velocity ratio of 0.455 shows more dispersive particle distribution. The simulation result shows similar tendency to the experimental result.

SF6 압력에 따른 결함별 부분 방전 펄스의 분포 분석 (Analysis on PD Pulse Distribution by Defects Depending on SF6 Pressure)

  • 김선재;조향은;정기우;길경석;김성욱
    • 한국전기전자재료학회논문지
    • /
    • 제28권1호
    • /
    • pp.40-45
    • /
    • 2015
  • Electrode systems: a protrusion on conductor (POC), a protrusion on enclosure (POE), a crack in epoxy plate and a free particle (FP) were fabricated to simulate insulation defects in a gas insulated switchgear (GIS). $SF_6$ gas was filled in the electrode systems by 3 bar and/or 5 bar, respectively. Partial discharge (PD) pulses were detected through a $50{\Omega}$ non-inductive resistor. A calibration test was carried out according to IEC 60270, and the sensitivity was 0.25 pC/mV. PD pulses were distributed in the phase of $50^{\circ}{\sim}135^{\circ}$ and over 95% of them existed in the phase of $55^{\circ}{\sim}120^{\circ}$ for the POC. PD pulses were distributed in the phase of $230^{\circ}{\sim}310^{\circ}$ and over 90% of them existed in phase of $220^{\circ}{\sim}300^{\circ}$ for the POE. PD pulses occurred in the phase of $40^{\circ}{\sim}60^{\circ}$ and $220^{\circ}{\sim}300^{\circ}$ for the crack, and pulse counts were 25% higher in negative polarity than in positive polarity. PD pulses were distributed in every phase unlike to other three electrode systems and the peak magnitude was measured at $118^{\circ}$ and $260^{\circ}$ for the FP. As described above, PD pulses were observed in positive polarity for the POC, in negative one for the POE, in both one for the crack and the FP. In conclusion, it is expected that the identification rate of defect type can be improved by considering the polarity ratio of PD pulses on the PRPDA method.

$Al_2O_3$$Y_2O_3$ 입자를 함유한 액상소결 SiC 재료의 특성 (Properties of Liquid Phase Sintered SiC Materials Containing $Al_2O_3$ and $Y_2O_3$ Particles)

  • 이상필;이문희;이진경
    • 한국해양공학회지
    • /
    • 제22권4호
    • /
    • pp.59-64
    • /
    • 2008
  • The mechanical properties of liquid phase sintered (LPS) SiC materials, with the addition of oxide powder, were investigated, in conjunction with a detailed analysis of their microstructures. LPS-SiC materials were fabricated at a temperature of 1820 $^{\circ}C$ under an argon atmosphere, using three different starting sizes of SiC particles. The sintering additive for the fabrication of the LPS-SiC materials was an $Al_2O_3-Y_2O_3$ mixture with a constant composition ratio ($Al_2O_3/Y_2O_3$: 1.5). The particle sizes of the commercial SiC powderswere 30 nm, 0.3 $\mu$m, and 3.0 $\mu$m. The flexural strength of the LPS-SiC materials was also examined at elevated temperatures. A decrease in the starting size of the SiC particles led to an increase in the flexural strength of the LPS-SiC materials, accompanying a highly dense morphology with the creation of a secondary phase. Such a secondary phase was identified as $Y_3Al_2(AlO_4)2$. The flexural strength of the LPS-SiC materials greatly decreased with an increase in the test temperature, due to the creation of a large amount of pores.

Investigation on seismic isolation retrofit of a historical masonry structure

  • Artar, Musa;Coban, Keziban;Yurdakul, Muhammet;Can, Omer;Yilmaz, Fatih;Yildiz, Mehmet B.
    • Earthquakes and Structures
    • /
    • 제16권4호
    • /
    • pp.501-512
    • /
    • 2019
  • In this study, seismic vulnerability assessment and seismic isolation retrofit of Bayburt Yakutiye Mosque is investigated. Bayburt Yakutiye Mosque was built in the early 19th century at about 30-meter distance to Coruh river in the center of Bayburt in Turkey. The walls of historical masonry structure were built with regional white and yellow stones and the domes of the mosque was built with masonry bricks. This study is completed in four basic phases. In first phase, experimental determination of the regional white stone used in the historical structure are investigated to determine mechanical properties as modulus of elasticity, poison ratio and compression strengths etc. The required information of the other materials such as masonry brick and the regional yellow stone are obtained from literature studies. In the second phase, three dimensional finite element model (FEM) of the historical masonry structure is prepared with 4738 shell elements and 24789 solid elements in SAP2000 software. In third phase, the vulnerability assessment of the historical mosque is researched under seismic loading such as Erzincan (13 March 1992), Kocaeli (17 August 1999) and Van (23 November 2011) earthquakes. In this phase, the locations where damage can occur are determined. In the final phase, rubber base isolators for seismic isolation retrofit is used in the macro model of historical masonry mosque to prevent the damage risk. The results of all analyses are comparatively evaluated in details and presented in tables and graphs. The results show that the application of rubber base isolators can prevent to occur the destructive effect of earthquakes.

푸시업플러스(Push-up plus) 운동 시 견갑골 익상 유무에 따른 어깨안정근의 근활성도 비교 (A Comparison of the Shoulder Stabilizer Muscle Activities During Push-up Plus Between Persons With and Without Winging Scapular)

  • 박준상;전혜선;권오윤
    • 한국전문물리치료학회지
    • /
    • 제14권2호
    • /
    • pp.44-52
    • /
    • 2007
  • This study was carried out to compare the muscle activities of the shoulder stabilizers between persons with and without winging scapular during push-up plus exercise (adds the scapular protraction to the general push-up exercise). For this study, eleven males with winging scapular and eleven healthy males were recruited. Surface electromyographic (EMG) activity was recorded from the serratus anterior, upper trapezius, lower trapezius, infraspinatus, and pectoralis major while the subjects performed the push-up plus. Each push-up plus was subdivided into three phases according to the elbow position which was measured using the 3-D motion analysis system: elbow flexion (EF), elbow extension (EE), and shoulder protraction phases (SP). Two-way repeated measure ANOVA (phase ${\times}$ group) were used for statistical analysis. There was significant phase by group interaction only on the EMG composition ratio of the serratus anterior (p>.05). The EMG composition ratio of the serratus anterior was significantly higher in SP than in either EF or EE however, it was not different between winging scapular and normal groups. For both groups, the EMG composition ratio of upper trapezius, lower trapezius, and pectoralis major was significantly different across the phases of push-up plus, but the infraspinatus EMG composition ratio was not. For both groups, in EF and EE phases, the EMG composition ratio of both pectoralis major and serratus anterior were relatively higher than that of other muscles. However, in both groups, the EMG composition ratio of the serratus anterior became much more predominant than that of the pectoralis major. In addition, infraspinatus activated greater than pectoralis major. These results showed that the push-up plus exercise is effective to selectively strengthen the serratus anterior for both individuals with and without winging scapular, but not equally effective for other shoulder stabilizers.

  • PDF