• 제목/요약/키워드: three dimensional scanner

검색결과 263건 처리시간 0.036초

Lower-body figure analysis of Chinese adult women

  • Cha, Sujoung
    • 복식문화연구
    • /
    • 제22권6호
    • /
    • pp.965-978
    • /
    • 2014
  • To determine the parameters to be considered when designing lower-body apparel, we analyzed the lower-body figures of adult women in their early 20s from Shanghai, China, using 3-dimensional whole body scanner. Thirty-nine lower-body-related measurements were used to analyze the figures of 210 Chinese women. Obesity and height of the lower body, length from waist to crotch, shape of abdomen, and leg bone length were analyzed. Factor analysis was performed and the results were classified into three clusters. The first cluster describes the obesity of the lower body, the second denotes small hip measurement, and the third describes slim and long legs. This is the first study to quantify figure analysis of the lower body of Chinese women using 3-dimensional body measurements. The findings of this study will provide concrete information regarding crotch width, crotch length, inseam, outseam, waist slope, etc., for designing trouser patterns for Chinese adult women.

소아 얼굴 연조직의 3차원 입체영상의 정확성 및 재현성 평가 (Accuracy and Precision of Three-dimensional Imaging System of Children's Facial Soft Tissue)

  • 최경화;김미선;이고은;남옥형;이효설;최성철;김광철
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.17-24
    • /
    • 2020
  • 이 연구의 목적은 소아 얼굴 연조직의 선형 길이를 비교하여 삼차원 입체영상의 정확성과 재현성을 평가하는 것이다. 연구는 7 - 12세 아동 15명을 대상으로 하였다. 환자의 안모에 23개의 계측 점을 표시하고, 전자 캘리퍼를 이용하여 16 개의 선형길이를 직접 2번 계측하였다. 3차원(3D) 스캐너를 이용하여 2개의3D 얼굴 영상을 만들었으며, 직접계측과 동일한 16개의 선형 길이를 계측하였다. 연구결과 정확성 평가에서 전체 평균 차이 값은 0.9 mm였다. 3D 영상의 재현성은 직접계측의 재현성과 거의 유사한 정도로 나타났다. 이에 따라 이 3D 영상장비는 소아에서 임상적으로 충분한 정확성과 재현성을 가지고 있었다. 3D 영상 시스템은 정확한 이미지를 위하여 대상의 협조가 필요하다. 소아의 정확한 3D영상을 얻기 위한 구체적인 지시사항을 바탕으로 촬영을 한다면, 이 3D 영상 장비는 향후 소아의 성장과 발달을 조사하고, 소아교정치료에서 결과를 평가하는데 유용하게 사용될 수 있을 것이다.

인공결석모형물의 부피와 하운스필드값 측정에 대한 전산화단층촬영기기의 타입과 빔 콜리메이션의 영향 (Effect of Different CT Scanner Types and Beam Collimations on Measurements of Three-Dimensional Volume and Hounsfield Units of Artificial Calculus Phantom)

  • 왕지환;이희천
    • 한국임상수의학회지
    • /
    • 제31권6호
    • /
    • pp.495-501
    • /
    • 2014
  • 본 연구는 다양한 전산화단층촬영기기와 촬영 프로토콜의 차이에 따른 모형물의 부피와 Hounsfield unit (HU) 수치의 차이를 평가하고 이 후 전산화단층촬영술을 이용하여 결석의 부피와 HU 수치를 포함한 다양한 인자들을 평가하고 이 중 체외충격파쇄석술에 의한 결석의 분쇄를 예측할 수 있는 인자를 찾고자 하였다. 다양한 직경의 100 HU 인공종양 5개를 (직경 3.0-12.0 mm) 이용하여 모형물을 만들었으며, 이 모형물의 부피와 HU 수치를 Siemens사의 2채널, GE사의 4채널과 64채널, 그리고 Philips사의 64채널 전산화단층촬영기기를 사용하여 평가하였다. 또한 각각의 전산화단층촬영기기에서 동일한 조건으로 collimation만 thin collimation과 thick collimation으로 변화를 주어 모형물을 촬영한 후 모형물의 부피와 HU 수치를 평가하였다. 평가자간 (inter-observer) 재현성을 평가하기 위해 3명의 수의영상의학 전공의가 연구에 참여하였으며 이중 한 명의 수의사가 평가자내 (intra-observer) 재현성을 평가하기 위해 모형물의 부피와 HU 수치를 2주 간격으로 총 3번 측정하였다. 부피의 평가자간 재현성과 평가자내 재현성은 k=0.9994, k=0.9969로 아주 우수하였으며, HU 수치의 평가자간 재현성과 평가자내 재현성 역시 k=0.9984, k=0.9655로 아주 우수하였다. 다양한 전산화단층촬영기기와 collimation 차이에 따른 부피와 HU 수치의 차이는 모두 통계학적으로 유의적인 차이를 나타내지 않았다. 그러나 부피의 경우 collimation이 얇을수록 부피의 정확도가 증가하는 경향을 보였다. 본 연구 결과를 토대로 향후 진행될 결석의 부피 및 HU 수치의 평가 시 전산화단층촬영기기의 차이에 따른 영향을 받지 않으리라 판단되어 Siemens사의 2채널 전산화단층촬영기기만을 사용하였으며, 비록 통계학적으로 유의적인 차이는 없었지만 부피의 정확도를 더 높이기 위하여 얇은 collimation을 사용하였다.

Evaluation of Knee Joint after Double-Bundle ACL Reconstruction with Three-Dimensional Isotropic MRI

  • Jung, Min ju;Jeong, Yu Mi;Lee, Beom Goo;Sim, Jae Ang;Choi, Hye-Young;Kim, Jeong Ho;Lee, Sheen-Woo
    • Investigative Magnetic Resonance Imaging
    • /
    • 제20권2호
    • /
    • pp.95-104
    • /
    • 2016
  • Purpose: To evaluate the knee joint after double-bundle anterior cruciate ligament (ACL) reconstruction with three-dimensional (3D) isotropic magnetic resonance (MR) image, and to directly compare the ACL graft findings on 3D MR with the clinical results. Materials and Methods: From January 2009 to December 2014, we retrospectively reviewed MRIs of 39 patients who had reconstructed ACL with double bundle technique. The subjects were examined using 3D isotropic proton-density sequence and routine two-dimensional (2D) sequence on 3.0T scanner. The MR images were qualitatively evaluated for the intraarticular curvature, graft tear, bony impingement, intraosseous tunnel cyst, and synovitis of anteromedial and posterolateral bundles (AMB, PLB). In addition anterior tibial translation, PCL angle, PCL ratio were quantitatively measured. KT arthrometric values were reviewed for anterior tibial translation as positive or negative. The second look arthroscopy results including tear and laxity were reviewed. Results: Significant correlations were found between an AMB tear on 3D-isotropic proton density MR images and arthroscopic proven AMB tear or laxity (P < 0.05). Also, a significant correlation was observed between increased PCL ratio on 3D isotropic MRI and the arthroscopic findings such as tear, laxities of grafts (P < 0.05). KT arthrometric results were found to be significantly correlated with AMB tears (P < 0.05) and tibial tunnel cysts (P < 0.05). Conclusion: An AMB tear on 3D-isotropic MRI was correlated with arthroscopic results qualitatively and quantitatively. 3D isotropic MRI findings can aid the evaluation of ACL grafts after double bundle reconstruction.

3차원 형상 계측에 의한 인대의 하반신 형태 파악 (The Analysis of the Lower Part of Dress Forms Using Three-Dimensional Measurement System)

  • 이명희;정희경
    • 한국생활과학회지
    • /
    • 제14권2호
    • /
    • pp.303-312
    • /
    • 2005
  • The purpose of this research is to analyze the lower part of dress forms with different sectional rotation-angles ($e.g.\;9^{\circ},\;15^{\circ},\;30^{\circ},\;45^{\circ}$) using three-dimensional measurement system and to investigate measurement properties for dress making. The dress forms used in this experiment were size 8 and six types: four from Korea and two from Japan. The instrument and tools for three-dimensional measurement was Whole Body 3D scanner (Exyma-WBS2H). The analysis program used in this experiment was Rapid Form 2004 PP1 (INUS technology, Inc, Korea). The measurement of dress forms was done three times with different sectional rotation-angles and its data were analyzed using SPSS WIN 10.0 Package. The following results were obtained: 1. With mean and standard deviation of each measured part, it was found out that the dress forms from two countries were different in size per each part. For example, the Japanese one was relatively large in middle hip and hip, compared to the Korean one. 2. The 3D analysis of the sectional rotation-angles revealed some differences between the two dress forms in sectional length per each part. 3. With cluster analysis results, it was found that there were definite differences among measurements per each part, especially in $30^{\circ}\;and\;45^{\circ}$ sections. 4. The proportion of the dress forms showed significant differences in the curvature between center and side section of the lower parts. In addition, the shapes on the horizontal section map of the four levels (waist, middle hip, hip, and bottom) were analyzed.

  • PDF

Anatomic Description of the Infraorbital Soft Tissues by Three-dimensional Scanning System

  • Peralta, Alonso Andres Hormazabal;Choi, You-Jin;Hu, Hyewon;Hu, Kyung-Seok;Kim, Hee-Jin
    • Journal of Korean Dental Science
    • /
    • 제14권2호
    • /
    • pp.101-109
    • /
    • 2021
  • Purpose: For minimally invasive procedures, three-dimensional (3D) anatomical knowledge of the structures of the face is essential. This study aimed to describe the thickness of the skin and subcutaneous tissue and depths of the facial muscles located in the infraorbital region using a 3D scanner to provide critical clinical anatomical guidelines for improving minimally invasive cosmetic procedures. Materials and Methods: The 3D scanning images of 38 Korean cadavers (22 males and 16 females; age range: 51~94 years at the time of death) were analyzed. Eight facial landmarks (P1~P8) were marked on the cadaveric faces. The images were scanned in three steps-undissected face, hemiface after skinning, and revealing the facial muscles. Student's t-test was used to identify significant differences. Result: The skin and subcutaneous tissue tended to become thicker from the upper to lower and medial to lateral aspects, and the muscles followed the same pattern as that of the most superficial located muscle and the deepest located muscles. No significant sex-related differences were found in the skin at any landmark. However, the muscles tended to be deeper in the female participants. Conclusion: The study data can serve as a basis for creating or enhancing clinical anatomy-based guidelines or improving procedures in the infraorbital region.

전신성 피부경화증 환자에서의 3차원 구강스캐너를 이용한 가철성 국소의치 제작 증례 (Fabrication of removable partial denture on scleroderma patient using 3-dimensional intraoral scanner)

  • 김웅규;한중석;윤형인;여인성
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.116-125
    • /
    • 2021
  • 디지털 치의학에서의 주요한 발전 중 하나인 3차원 구강스캐너는 최근 고정성 보철물에 널리 사용되고 있으며 가철성 보철물에서도 사용이 증가하고 있다. 전신성 피부경화증에 의한 안면부 연조직의 경화는 개구량 제한을 일으켜 치아상실을 야기하며 기존의 통상적인 보철 치료를 어렵게 한다. 본 증례에서는 디지털 치의학의 발전을 통한 3차원 구강스캐너를 이용하여 개구량 제한과 그에 따른 소구증을 가진 전신성 피부경화증 환자에서 3차원 구강구조를 광학인상 채득하고, 이를 바탕으로 3D 프린터를 이용한 임시의치 제작을 통해 3차원 구강스캐너를 통한 가철성 보철물 제작의 가능성을 확인하였다. 이후 최종 지대치 정리 후 최종 광학인상 채득하여 국소의치 금속구조물을 제작하였다. 금속구조물의 적합도는 임상적으로 만족스러웠으며 이후 최종 국소의치 제작, 장착하여 상실부위에 대한 수복을 진행, 임상적으로 만족스러운 결과를 얻을 수 있었다.

유방 MRI의 최대강도투사 기법에 의한 3차원 재구성 영상의 유용성 (The Value of Three-Dimensional Reconstructions of MRI Imaging using Maximum Intensity Projection Technique)

  • 조재환;이해각;홍인식;김현주;장현철;박철수;박태남
    • 디지털콘텐츠학회 논문지
    • /
    • 제12권2호
    • /
    • pp.157-164
    • /
    • 2011
  • 유방암중 관상피내암으로 진단 받은 환자를 대상으로 조영제 주입전, 후의 감산된 영상과 3차원 재구성된 영상을 정량적으로 비교 분석하여 재구성된 영상의 효과와 유용성을 고찰 해보고자 한다. 조직학적으로 관상피 내암으로 진단 받은 환자 20명을 대상으로 3.0T MR scanner를 이용하여 감산된 영상과 3차원 재구성한 영상을 획득하였다. 분석 결과 감산 영상과 재구성한 영상에서 신호대 잡음비는 병변, 유관조직, 지방조직에서 재구성한 영상에서 높은 신호대 잡음비를 보였으며 두 영상에서의 대조 도대 잡음비는 차이를 보이지 않았다.

치과용 스캐너 전용 석고를 이용하여 제작된 3차원 디지털 모형의 정확도 평가 (An evaluation of validity of three dimensional digital model fabricated by dental scannable stone)

  • 김기백;김수진;김재홍;김지환
    • 대한치과기공학회지
    • /
    • 제35권1호
    • /
    • pp.29-35
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the validity of digital models fabricated by dental scannable stone. Methods: Twenty same cases of stone models(maxillary full arch) were manufactured. Intercanine distance, intermolar distance, two dental arch lengths(right, left), two diagonal of dental arch lengths(right, left) were measured for comparison. Each of ten stone models were measured by digital vernier calipers and scanned by dental scanner. Ten digital models were measured by CAD program. The mean(SDs) values were compared by a Mann-Whitney U test(${\alpha}$=0.05). Results: No statistically significant differences between the two groups were found at intermolar distance, dental arch length(right)(p>0.05). However, intercanine distance, dental arch length(left) and two diagonal of dental arch lengths(right, left) were statistically significant(p<0.05). Conclusion: Stone models fabricated by dental scannable stone showed larger than digital models.

3차원 스캐닝을 활용한 사면의 안정성 평가 및 대책공법수립 (Establishment of remedial methods and evaluation of slope stability using 3D scanning)

  • 임은상;김범주;오석훈;임정열;김영경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.711-719
    • /
    • 2006
  • In this study, a 3D laser scanner is applied to evaluate of the stability of rock slope and to establish a adequate counter-method. From 3D scanning results, three dimensional digital data of rock slope is acquired, and then it is investigated for the engineering properties of discontinuities in rock mass. On the base of the result, we carry out the analysis of slope stability using the methods of the stereographic projection. In particular, the use of a 3D laser scanner is powerful about the slope on which person is difficult to approach because we can obtain the informations of discontinuities from the 3D digital data.

  • PDF