• 제목/요약/키워드: three dimensional measurement

검색결과 1,022건 처리시간 0.029초

Fast Estimation of Three-dimensional Spatial Light Intensity Distribution at the User Position of an Autostereoscopic 3D Display by Combining the Data of Two-dimensional Spatial Light Intensity Distributions

  • Hyungki Hong
    • Current Optics and Photonics
    • /
    • 제8권3호
    • /
    • pp.307-312
    • /
    • 2024
  • Measuring the three-dimensional (3D) spatial light intensity distribution of an autostereoscopic multiview 3D display at the user position is time-consuming, as luminance has to be measured at different positions around the user position. This study investigates a method to quickly estimate the 3D distribution at the user position. For this purpose, a measurement setup using a white semitransparent diffusing screen or a two-dimensional (2D) spatial sensor was devised to measure the 2D light intensity distribution at the user position. Furthermore, the 3D spatial light intensity distribution at the user position was estimated from these 2D distributions at different viewing distances. From the estimated 3D distribution, the characteristics of autostereoscopic 3D display performance can be derived and the candidate positions for further accurate measurement can be quickly determined.

3차원 영상처리를 이용한 안면마비 평가시스템 개발 (Development of Facial Palsy Grading System with Three Dimensional Image Processing)

  • 장민;신상훈
    • 재활복지공학회논문지
    • /
    • 제9권2호
    • /
    • pp.129-135
    • /
    • 2015
  • 본 연구에서는 3차원 영상처리와 노팅험 스케일을 이용하여 안면마비 평가 시스템을 개발하였다. 시스템은 측정부, 영상처리부, 연산부, 그리고 안면마비 평가 및 출력부로 구성되어 있다. 두 개의 웹캠을 사용하여 안면부의 8곳에 부착된 마커의 3차원 위치를 계산하였으며, 이를 이용하여 노팅험 스케일을 계산하고 화면에 보여준다. 피험자의 자세변화와 측정방식이 노팅험 스케일에 미치는 영향을 조사하였다. 측정방식은 2차원과 3차원을 비교하였으며, 피험자자세는 정면응시와 $11^{\circ}$ 측면응시를 비교하였다. 측면응시한 피험자를 2차원 방식으로 측정한 경우의 오차가 가장 컸다. 3차원 측정방식이 피험자의 자세변화에 따른 오차에 가장 덜 민감하였다.

  • PDF

디지털 화상처리를 이용한 유동장의 비접촉 3차원 고속류 계측법의 개발 (Developemet of noncontact velocity tracking algorithm for 3-dimensional high speed flows using digital image processing technique)

  • 도덕희
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권2호
    • /
    • pp.259-269
    • /
    • 1999
  • A new algorithm for measuring 3-D velocity components of high speed flows were developed using a digital image processing technique. The measuring system consists of three CCD cameras an optical instrument called AOM a digital image grabber and a host computer. The images of mov-ing particles arranged spatially on a rotation plate are taken by two or three CCD cameras and are recorderd onto the image grabber or a video tape recoder. The three-dimensionl velocity com-ponents of the particles are automatically obtained by the developed algorithm In order to verify the validity of this technique three-dimensional velocity data sets obtained from a computer simu-lation of a backward facing step flow were used as test data for the algorithm. an uncertainty analysis associated with the present algorithm is systematically evaluated, The present technique is proved to be used as a tookl for the measurement of unsteady three-dimensional fluid flows.

  • PDF

레이저 비전을 이용한 3차원 측정 시스템 구현 (Development of a 3-Dimensional Measurement System using Laser Vision)

  • 권효근;천영석;서영수;노영식
    • 전기학회논문지
    • /
    • 제56권5호
    • /
    • pp.973-979
    • /
    • 2007
  • A laser vision system is developed to measure the three-dimensional feature of an object. This system consists of two low cost cameras and a cross laser. One camera and a cross laser are used to measure a plane equation of an object. Using this information, the other camera measures a hole size of an object. The proposed system provides 0.05 mm accuracy measurement systems with relatively low cost.

Volumetric Interferometry Using Spherical Wave Interference for Three-dimensional Coordinate Metrology

  • Rhee, Hyug-Gyo;Chu, Ji-Young;Kim, Seung-Woo
    • Journal of the Optical Society of Korea
    • /
    • 제5권4호
    • /
    • pp.140-145
    • /
    • 2001
  • We present a new method of volumetric interferometer, which is intended to measure the three-dimensional coordinates of a moving object in a simultaneous way with a single optical setup. The method is based on the principles of phase-measuring interferometry with phase shifting. Two diffraction point sources, which are made of the polished ends of single-mode optical fibers are embedded on the object. Two spherical wavefronts emanate from the diffraction point sources and interfere with each other within the measurement volume. One wavefront is phase-shifted by elongating the corresponding fiber using a PZT extender. A CCD array sensor fixed at the stationary measurement station detects the resulting interference field. The measured phases are then related to the three-dimensional location of the object with a set of non-liner equations of Euclidean distance, from which the complete set of three-dimensional spatial coordinates of the object is determined through rigorous numerical computation based upon the least square error minimization.

3차원 음향 인텐시티 프로브의 고주파 영역 감도 보상 연구 (A Study on the Sensitivity Compensation of Three-dimensional Acoustic Intensity Probe in the Higher Frequency Range)

  • 김석재;;김천덕
    • 한국음향학회지
    • /
    • 제13권5호
    • /
    • pp.40-50
    • /
    • 1994
  • 본 논문에서는 3차원 음향 인텐시티 프로브의 고주파 영역에서 발생하는 감도 저하 현상을 보정하는 방법에 대해 연구하였다. 고주파 영역에서 측정오차는 음향 인텐시티 프로브를 구성하는 마이크로폰으로 수음한 신호들의 위상차로 인하여 발생한다. 이 오차는 마이크로폰 사이의 간격보다 측정대상 음향신호의 파장일 작을 경우, 즉 신호의 주파수가 높을수록 크게 발생한다. 이 연구에서는 두개의 마이크로폰으로 구성된 1차원 프로브의 보정법들을 제안하여 그 유효성을 컴퓨터 수치계산으로 검토하였다. 음향 인텐시티 프로브를 구성하는 마이크로폰 사이의 위상차를 음원의 추정된 방향으로 보정하는 방법이 가장 유용하였으며, 이를 3차원 프로브에 적용하여 임의의 방향으로 전파하는 음원에 대해 컴퓨터 수치계산으로 검증하였다. 그 결과, 4개의 마이크로폰을 60mm 간격으로 구성한 3차원 프로브로 1dB 이하의 정밀한 측정이 가능한 주파수 범위가 약 1.2kHz 이였던 것을 제안한 보정방법을 적용한 후, 약 2.8kHz까지 감도가 향상됨이 확인되어 제안한 보정법의 유효성이 증명되었다.

  • PDF

PMP 형상 측정법의 열 변위 보정에 관한 연구 (A Study on the Compensation of Thermal Errors for Phase Measuring Profilometry)

  • 김기승;박윤창
    • 한국산학기술학회논문지
    • /
    • 제20권6호
    • /
    • pp.598-603
    • /
    • 2019
  • 삼차원 형상 측정 기술은 다양한 산업에서 활용하고 있는 기술이다. 그 중, 광 삼각법에 기초한 광학식 삼차원 형상 측정 기술들은 매일 공장에서 오랜 시간 동안 대량의 삼차원 형상 측정을 하고, 미세한 측정 또한 요구되는 반도체 생산품 검사 분야에서 주로 사용된다. 이러한 광 삼각법 기반의 삼차원 측정 장비들의 구성 요소인 광원과 구동 회로는 장시간 작동하게 되면 발열이 나타나게 되고 장시간 작동하며 주변의 온도가 일정하지 않은 상황에 노출되기도 하여 온도로 인한 측정 오차가 발생하게 된다. 본 논문에서는 장시간 반복해서 사용하는 PMP(Phase Measuring Profilometry) 형상 측정법에서의 열 변위 보정에 관한 방법을 제안하였다. PMP 형상 측정법 기반의 삼차원 형상 측정 장치를 구현하여 10시간에 걸쳐 물체의 높이와 주변 온도를 측정하는 실험을 진행하였고, 측정된 온도와 높이 값을 이용하여 단순 선형 회귀 분석을 하여 회귀직선을 얻었다. 이 회귀직선을 이용하여 온도에 따른 높이 측정값의 오차를 보정하게 되면 정상적인 측정값에서의 오차 값이 139.88 um(Micrometer) 에서 13.12 um로 보정되는 것을 확인하였다.

3차원 인텐시티 프로브의 근거리 음장 측정에서의 오차 수치해석 (Numerical analysis for nearfield measurement error in a three-dimensional intensity probe.)

  • 김석재;지석근;;김천덕
    • 한국음향학회지
    • /
    • 제13권3호
    • /
    • pp.41-50
    • /
    • 1994
  • 이 연구에서는 3차원 음향 인텐시티를 동시에 측정할 수 있는 프로브를 이용하여 음향 인텐시티를 측정할 때 필연적으로 발생하는 오차를 컴퓨터의 수치계산으로 검토하였다. 이 3차원 음향 인텐시티 프로브는 Suzuki등에 의해 제안된 4개의 마이크로폰으로 구성된 것이고, 수치계산에서는 이상적인 점음원과 유한 크기를 가지는 면음원에 대해서 프로브의 각 축방향 및 임의의 방향에 대한 측정오차를 근거리 음장에서 분석하였다. 그 결과, 점음원의 경우 측정거리가 프로브를 구성하는 마이크로폰 사이의 간격보다 약 2.5배 이상 떨어진 거리에서 오차 1dB 이하의 정밀한 측정을 할 수 있었고, 유한 크기의 면음원의 경우, 면음원의 한 변의 길이가 0.02m이상일 때 근거리 음장의 측정오차가 크게 감소하기 시작하여, 한 변의 길이가 0.2m일 때 측정거리가 마이크로폰 사이의 간격보다 0.67배로 근접하여 측정하여도 1dB 이하의 정밀한 측정이 가능한 것으로 평가되어 이 프로브의 근거리 음장 측정의 유효성이 확인되었다.

  • PDF

인체측정용 3차원 스캐너 제작 (Development of Three Dimensional Scanner for Anthropometric Measurement)

  • 김민효;남윤자
    • 대한인간공학회지
    • /
    • 제20권3호
    • /
    • pp.77-88
    • /
    • 2001
  • A three dimensional body scanner for anthropomentric measurement has been developed. In this study, the slit laser beam projection method followed by digital image processing was used to provide accurate spatial data with the typical optical triangulation method to overcome the many difficulties in traditional in accurate and time-consuming tactic measurement method using rulers and gauges. Compared with other commercialized scanners. this system can obtain a relatively wide range of data at a much lower cost by the specially designed scanning process such as the simultaneous acquisition of vertical and horizontal body cross-section profiles.

  • PDF