• Title/Summary/Keyword: thickness sensitivity

Search Result 656, Processing Time 0.025 seconds

Optimization of HDD Suspension Shape Using Sensitivity Analysis and Sequential Linear Proframing (감도해석 및 순차적 선형계획법을 이용한 HDD 서스펜션의 형상 최적화)

  • Hwang, Chang-Ho;Kim, Dong-Wook;Park, No-Cheol;Lee, Jongsoo;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.319.2-319
    • /
    • 2002
  • The main obstacle to high track density in HDD id the structural resonances of the suspension. The most critical mode is sway mode and second torsion mode, when a data is read and written. It is common fact that the effect of two modes is smaller when a thickness is bulky. But the stiffness of suspension is smaller, the slider can follow a disk better. Because these two fact are reciprocal, a compromise is needed. So we investigated another method to improve band width without changing of the thickness of suspension but with changing of the shape. (omitted)

  • PDF

Study on Comparison of Korean Industrial Standard and ASME BPV Code for Radiographic Examination (방사선투과시험(放射線透過試驗)에 있어서 KS와 ASME Code의 비교(比較)에 관(關)한 연구(硏究))

  • Kim, Jin-Koo;Park, Byung-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.4 no.2
    • /
    • pp.20-29
    • /
    • 1985
  • There are two basic concepts in industrial radiographic examination; one is a radio-graphic sensitivity, and the other is a acceptance criteria. The comparison of these main points are studied for KS Standard and ASME Boiler and Pressure Vessel Code. From the results of the experiment, higher radiographic sensitivity is required in KS Standard when the thickness of material to be examined is less than 20mm in single wall technique. The acceptance criteria for linear type indications are described on same concept in two standards, whereas the acceptance criteria for rounded indications of KS Standard which mainly depends upon the object thickness are more severe than those of ASME BPV Code.

  • PDF

GMR and Magnetization Study of Sputtered Permalloy/Cu Multilayer: The Influence of Temperature, Thickness and Number of Magnetic Layer

  • Lucinski, T.;Stobiecki, F.;Urbaniak, M.
    • Journal of Magnetics
    • /
    • v.4 no.1
    • /
    • pp.17-21
    • /
    • 1999
  • The GMR ($d_Cu$) oscillatory behaviour as well as the widths of first and the second antiferromagnetically coupled ranges of the Permalloy ($Py=Ni_{83}Fe_{17}$)/Cu multilayers have been found to be strongly affected not only by the presence of the superparamagnetic/paramagnetic entitles located at the Py/Cu interfaces but mainly by the existence of the magnetic bridges between Py layers. The effectiveness of the magnetic bridges has been found to be temperature dependent, leading to the temperature dependence of the remnant to saturation magnetization ratio ($M_R/M_S$). We have found that for Py/Cu multilayers with equal Py and Cu layer thicknesses a high field sensitivity of the GMR effect (0.4%/Oe) and negligible hysteresis can be achieved when the number of Py layers decreases from 100 to 6. Sensitivity can be further improved by increasing the Py layers thickness, but the hysterstic effect becomes more pronounced then.

  • PDF

Characteristics of Pd doped $SnO_2$ gas sensitive thin films (Pd이 도핑된 $SnO_2$ 박막 가스감지막의 특성)

  • Kim, Jin-Hae;Kim, Dae-Hyun;Lee, Yong-Sung;Kim, Jeong-Gyoo;Jeon, Choon-Bae;Park, Hyo-Derk;Park, Ki-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1779-1781
    • /
    • 2000
  • Pd doped $SnO_2$ thin film sensors were prepared on alumina substrate by rf magnetron sputtering method. The sensitivity of thin film was investigated by varying the heat-treatment temperature, film thickness and gas species. The thin film heat-treated at 600$^{\circ}C$ and film thickness of 5000${\AA}$ showed the highest sensitivity at an operating temperature of 400$^{\circ}C$.

  • PDF

Design studies for mandrel type fiber-hydrophones with FEM (FEM을 이용한 맨드랠(Mandrel) 형광- 음향 수중 청음기의 설계에 관한 연구)

  • Im, Jong-In;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3
    • /
    • pp.73-80
    • /
    • 1997
  • This paper describes structural optimization of optical fiber-wound mandrel hydrophones with Finite Element Method (FEM). The hydrophone is supposed to have operation frequency range of up to 10 kHz and show omni-directional sensitivity pattern at 5 kHz. Studied parameters are mandrel geometry, molding thickness, and material properties of constitutional parts of the hydrophone. Theoretical calculation result shows that pressure sensitivity of the hydrophone increased as either mandrel length or molding thickness gets larger. Also higher pressure sensitivity requires a mandrel or molding material with relatively low Youngs modulus or Poissons ratio. Hydrophone bandwidth increases either as the mandrel length becomes shorter or as the mandrel becomes harder. The omni-directional characteristic is improved as the mandrel length becomes shorter, at 5 kHz. With the above results, we determine the structure of an optical fiber-wound mandrel hydrophone which has the pressure sensitivity of $30 {\times} 10_{-7}$ Rad./Pa, operation frequency range of up to 10 kHz, and shows omni-directional sensitivity pattern at 5 kHz.

  • PDF

Study on Electrical Properties of X-ray Sensor Based on CsI:Na-Selenium Film

  • Park Ji-Koon;Kang Sang-Sik;Lee Dong-Gil;Choi Jang-Yong;Kim Jae-Hyung;Nam Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.4 no.3
    • /
    • pp.10-14
    • /
    • 2003
  • In this paper, we have introduced the x-ray detector built with a CsI:Na scintillation layer deposited on amorphous selenium. To determine the thickness of the CsI:Na layer, we have estimated the transmission spectra and the absorption of continuous x-rays in diagnostic range by using computer simulation (MCNP 4C). A x-ray detector with 65 ${\mu}m$-CsI:Na/30 ${\mu}m$-Se layer has been fabricated by a thermal evaporation technique. SEM and PL measurements have been performed. The dark current and x-ray sensitivity of the fabricated detector has been compared with that of the conventional a-Se detector with 100 ${\mu}m$ thickness. Experimental results show that both detectors exhibit a similar dark current, which was of a low value below $400 pA/cm^2$ at 10 V/${\mu}m$. However, the CsI:Na-Se detector indicates high x-ray sensitivity, roughly 1.3 times that of a conventional a-Se detector. Furthermore, a CsI:Na-Se detector with an aluminium reflective layer shows a 1.8 times higher x-ray sensitivity than an a-Se detector. The hybrid type detector proposed in this work exhibits a low dark current and high x-ray sensitivity, and, in particular, excellent linearity to the x-ray exposure dose.

Ultrasonographic evaluation of skin thickness in small breed dogs with hyperadrenocorticism

  • Heo, Seonghun;Hwang, Taesung;Lee, Hee Chun
    • Journal of Veterinary Science
    • /
    • v.19 no.6
    • /
    • pp.840-845
    • /
    • 2018
  • The purpose of this study was to propose a standard for differentiation between normal dogs and patients with hyperadrenocorticism (HAC) by measuring skin thickness via ultrasonography in small breed dogs. Significant changes in skin thickness of patients treated with prednisolone (PDS) or patients with HAC treated with trilostane were evaluated. Skin thickness was retrospectively measured on three abdominal digital images obtained from small breed dogs weighing < 15 kg that underwent abdominal ultrasonography. Mean skin thickness of normal dogs was $1.03{\pm}0.25mm$ (mean ${\pm}$ SD). Both the HAC and PDS groups showed significantly thinner skin than that in the normal group. Seven of the 10 HAC patients treated with trilostane had increased skin thickness. The area under the curve value of 0.807 was based on the receiver operating characteristics (ROC) curve for differentiating normal dogs from HAC patients. Sensitivity was 76% and specificity was 73% when skin thickness was less than the 0.83 mm cutoff value. In conclusion, measurement of skin thickness in small breed dogs by using ultrasonography is likely to provide clinical information useful in differentiating HAC patients from normal dogs. However, exposure to PDS, trilostane, and other conditions may have a significant effect on skin thickness.

Development of Mechanistic-Empirical Overlay Pavement Design Program (역학적-경험적 덧씌우기 포장 설계 프로그램 개발)

  • Baek, Cheol-Min;Yang, Sung-Lin;Park, Hee-Mun;Kang, Tae-Wook
    • International Journal of Highway Engineering
    • /
    • v.14 no.4
    • /
    • pp.19-28
    • /
    • 2012
  • PURPOSES : Recently, the mechanistic-empirical overlay pavement design program that is linked with Korea Pavement Research Program (KPRP) has been developed. This paper focused on establishing the framework and developing the program for the asphalt overlay design over the existing asphalt concrete pavement. METHODS : The overlay pavement design program developed in this study was investigated to assess the sensitivity to various pavement conditions, such as the damage level and thickness of existing layers. In addition, the actual overlay design on currently performing pavement was carried out as a practical example. RESULTS : From the sensitivity analysis, it was found that the thickness and damage level of existing asphalt layer mostly affect the overlay design results. In addition, under the same condition, the overlay pavement would better perform in cold region. From the overlay design with the actual condition, it is noted that the overlay thickness varies depending on the given condition. CONCLUSIONS : Based on various evaluations, it was concluded that the overlay design program developed in this study is a reliable and reasonable tool to be used in the actual pavement design.

Magnetoresistance Effect of Ta/NiFe/Cu/Co Pseudo Spin Valve Structure (Ta/NiFe/Cu/Co Pseudo 스핀밸브 구조의 자기저항 효과)

  • Joo, Ho-Wan;Choi, Jin-Hyup;Choi, Sang-Dae;Lee, Ky-Am
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.25-28
    • /
    • 2004
  • The dependence of sensitivity, MR ratio, coercivity (Hc) and switching fields as a function of thickness of each magnetic layers(Co, NiFe and Cu) were investigated in pseudo spin valves with a structure of Ta/NiFe/Cu/Co. As measured results dependence of the thickness of each magnetic layer, we obtained MR ratio of 7.26% for Ta(4 nm)/NiFe(7.5 nm)/Cu(3 nm)/Co(5 nm) pseudo spin valves. Also, we could control properties of magnetoresistance for independent magnetization courses of each magnetic layer. Especially, we found that we could control coercivity as constant MR ratio dependence of Co thickness.

Charge Transport Characteristics of a-Se based X-ray Detector (비정질 셀레늄 기반의 X선 검출 센서의 전하 수송 특성)

  • Kang, Sang-Sik;Cha, Byung-Youl;Jang, Gi-Won;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.375-378
    • /
    • 2002
  • There has recently been a great deal of interest in amorphous selenium for application of digital x-ray image sensor. The initial number of the electron-hole induced by interaction a-Se with x-ray photons and the collection efficiency to surface of generated charges are important parameters for x-ray sensitivity of the a-Se. Therefore, in this paper, we analyzed that thickness of a-Se film and electric field is affected on the initial number of electron-hole and the collection efficiency. The experimental value of x-ray induced charge about the various thickness and the electric field is compared with estimated absorbed energy through MCNP 4C code to analyze the mechanism x-ray induced signal of a-Se. The experimental results showed that the electric field depends on initial escape coefficient and the thickness depends on collection coefficient than escape efficient.

  • PDF