Study on Effective Point of Measurement for Parallel Plate Type ionization Chamber with Different Spacing (평행평판형 이온함의 두 전극간의 간격 변화에 따른 유효측정점에 관한 연구)

  • 신교철;윤형근
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this work, EPM (effective point of measurement) of parallel plate ionization chamber with three different spacing were investigated. If the plate separation is less than 2 mm one generally assumes that the effective point of measurement is just behind the front window of the parallel plate ionization chamber. For chamber with relatively large separation, such as the ones used for very accurate exposure measurements, this assumption breaks down and the EPM depends on plate separation and thickness of the front window. For parallel plate chambers, conventional theoretical analyses suggest that the EPM is the inner front wall and that it shifts towards the geometric centre of the chamber as the plate separation increases. The PP-IC (parallel plate ionization chamber) is fabricated using acrylic plate for the chamber medium and printed circuit board for electrical configuration. The various sizes of the sensitive volumes designed so far are 0.9, 1.9, and 3.1 cc. The gap between two electrodes ranges from 3, 6, and 10mm. Also the charge-to-voltage converter is designed to collect the electrons produced in the ionization chamber cavity. As the result of our experiment, the EPM shift was within 0.6 mm in photon beams and 0.4 mm to 2.5 mm in electron beams for the plate separation of 6 mm and 10 mm. EPM shifts towards the geometric center of the chamber as the plate separation increases.

  • PDF

Occurrence and Chemical Composition of Minerals from the Pallancata Ag Mine, Peru (페루 Pallancata 은 광산에서 산출되는 광물들의 산상 및 화학조성)

  • Yoo, Bong Chul;Acosta, Jorge
    • Journal of the Mineralogical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.87-102
    • /
    • 2019
  • Pallancata Ag mine is located at the Ayacucho region 520 km southeast of Lima. The geology of mine area consists of mainly Cenozoic volcanic-intrusive rocks, which are composed of tuff, andesitic lava, andesitic tuff, pyroclastic flow, volcano clasts, rhyolite and quartz monzonite. This mine have about 100 quartz veins in tuff filling regional faults orienting NW, NE and EW directions. The Ag grades in quartz veins are from 40 to 1,000 g/t. Quartz veins vary from 0.1 m to 25 m in thickness and extend to about 3,000 m in strike length. Quartz veins show following textures including zonation, cavity, massive, breccia, crustiform, colloform and comb textures. Wallrock alteration features including silicification, sericitization, pyritization, chloritization and argillitization are obvious. The quartz veins contain calcite, chalcedony, adularia, fluorite, rutile, zircon, apatite, Fe oxide, REE mineral, Cr oxide, Al-Si-O mineral, pyrite, sphalerite, chalcopyrite, galena, electrum, proustite-pyrargyrite, pearceite-polybasite and acanthite. The temperature and sulfur fugacity ($f_{s2}$) of the Ag mineralization estimated from the mineral assemblages and mineral compositions are ranging from 118 to $222^{\circ}C$ and from $10^{-20.8}$ to $10^{-13.2}atm$, respectively. The relatively low temperature and sulfur-oxygen fugacities in the hydrothermal fluids during the Ag mineralization in Pallancata might be due to cooling and/or boiling of Ag-bearing fluids by mixing of meteoric water in the relatively shallow hydrothermal environment. The hydrothermal condition may be corresponding to an intermediate sulfidation epithermal mineralization.

Lodging Related Traits of Rice Plants as Affected by ′KIM -112′ Application (KIM-112 처리가 벼 도복관련형질에 미치는 영향)

  • Choi, Chung-Don;Kim, Soon-Chul;Lee, Soo-Kwan
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.35 no.3
    • /
    • pp.218-223
    • /
    • 1990
  • This experiment was carried out to obtain basic information on the lodging characteristics and yield components of rice plants by new anti-lodging reagent 'KIM-112' (3%, Wp) application at 30 days before heading (DBH) to 5 DBH under two dosage levels (lg 2g, a. i. /10a) at the Yeongnam Crop Experiment Station in 1989. Culm length was shortened by 10-17% at 1g, a. i. /10a and by 16-23% at 2g of KIM -112 applications. The shortening effect of internode was different by dosages and application times: 2g treatment was greater effect than 19 and early application resulted in shortening of lower internode while this was upper internode at the late application. There were positive correlation between culm length and lodging index, the 1st and the 4th internode lengths had on important effect to lodging index. Thickness of culm wall, culm diameter and weight of basal part of culm were not affected by KIM-112 application. However anti-lodging characters improved by increasing the breaking weight and by decreasing the moment. Lodging index was related to breaking weight, moment and weight of panicle. Heading date by KIM-112 application was delayed one to four days and number of grains per panicle was decreased by shortened panicle length as compared with untreated control, but yield capacity was high a little because of improvement ripening ratio by no lodging.

  • PDF

Nonlinear Finite Element Analysis of the Reinforced Concrete Panel using High-Strength Reinforcing Bar (고강도 철근을 사용한 철근콘크리트 패널의 비선형 유한요소해석)

  • Cheon, Ju-Hyun;Seong, Dae-Jung;Cho, Hong-Jae;Cho, Jae-Yeol;Shin, Hyun-Mock
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.5
    • /
    • pp.481-488
    • /
    • 2015
  • The purpose of this study is to provide analytical method to reasonably predict the overall behavior up to destruction of reinforced concrete panel specimens using high-strength reinforcing bar. A total of 12 specimens of reinforced concrete panels with a wall thickness one-third the size of the actual nuclear containment structures under various loading conditions and design parameters were selected and the analysis was performed using a non-linear finite element analysis program (RCAHEST) was developed by the authors. The mean and coefficient of variation for shear strength at cracking point and maximum shear strength from the experiment and analysis results was predicted 1.03 and 12%, 0.97 and 9%, respectively. For the shear strain at the maximum shear strength from the experiment and analysis results was predicted 0.96 and 30%, respectively. Based on the results, the analysis program that was applied newly modified constitutive equation in this study is judged as having a relatively high reliability for the analysis results.

Mixture of Extracts of Cynanchum wilfordii and Phlomis umbrosa Turcz. Does Not Have an Estrogenic Effect in Ovariectomized Rats (백수오와 한속단 추출물의 비에스트로젠 효과에 관한 연구)

  • Han, Song-Hee;Lee, Tae-Hee;Jang, Ja-Young;Song, Hyun-Kyung;Hong, Sang-Keun;Kim, Yu-Ri;Han, Beom-Seok
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.5
    • /
    • pp.667-672
    • /
    • 2015
  • Cynanchum wilfordii and Phlomis umbrosa Turcz. are known to contain isoflavone, a representative phytoestrogen. This study was performed to determine whether the extract mixture of C. wilfordii and P. umbrosa Turcz. would induce an estrogenic effect in ovariectomized rats. The extracts were administered to the ovariectomized rats at 30, 60, 120 mg/kg per day for 4 weeks, respectively. They showed no estrogenic effect, which was indicated by the decrease in uterus wall thickness as well as the increase in body weight and the level of cholesterol and triglyceride. The extracts also had no effect on the concentrations of estrogen and growth hormone in the serum. However, the increase in alkaline phosphatase activity, which leads to protection against the bone loss caused by ovariectomy, was noted on administration of the extract. Therefore, it seemed that the extracts of C. wilfordii and P. umbrosa Turcz. had no estrogenic effect in rats.

The Design and Protective Capacity Assessment of the Prefabricated PC Arch Ammo Magazines (아치형 조립식 PC 탄약고 설계 및 방호성능 평가)

  • Park, Jang-Kweon;Lim, Chul-Won;Ryu, Dong-Woo;Son, Ki-Young;Baek, Jong-Hyuk;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.6
    • /
    • pp.615-621
    • /
    • 2014
  • This study suggests the design and assembly drawing of the prefabricated precast concrete arch ammo magazines using the numerical analysis as well as the explosion verification test. The protective capacity of the proposed magazines is identified with the maximum support rotation angles measured by explosion verification tests according to the U.S. Unified Facility Criteria 3-340-02. Using numerical analysis, it is examined that oval-type members are better than the semi-circle ones in terms of protective capacity. Based on this numerical results, the design and assemble drawing for the prefabricated precast concrete arch ammo magazine are developed. It is identified that the structure constructed by invented design and assembly drawing has enough protective capacity against blast pressure caused by 133.75kg TNT explosion. The detonation point cannot be open due to the military security. In sum, it could be concluded that the ammo magazine proposed in this study has reliable protective capacity with enough redundancy. The redundancy means that there are more economic design approach with reducing the curved wall thickness.

Economic Evaluation on Geosynthetic Reinforced Abutment for Railways (토목섬유로 보강된 철도교대의 경제성 평가)

  • Kim, Dae Sang;Kim, Ung-Jin;Sung, Keun-Yeol;Kim, Hak-Mo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.508-517
    • /
    • 2018
  • This study evaluated the construction costs of 11 design cases to decrease the horizontal forces applied to an abutment. They include two kinds of abutment types, which are used to improve the backfill materials for reversed T-shaped abutment and geosynthehtic reinforced abutment for railways (RAR). In the first economic analysis, the internal friction angles of the backfill materials were increased from ${\Phi}=35^{\circ}$ to ${\Phi}=40^{\circ}$ and $50^{\circ}$ for a reversed T-shaped abutment. The second analysis examined cases with the design of a geosynthehtic RAR. When the friction angles were $40^{\circ}$ or $50^{\circ}$ after improvement of the backfill material, the reduction in the construction cost of the abutment was not as large (2.0-3.9%), even though the horizontal forces on the abutment were decreased by 18-48%. However, in the case of applying the RAR, a maximum cost reduction of 30% was achieved by decreasing the horizontal force to zero. The cost reduction results from the decreased wall thickness, base slab size, and the number of pile foundations for the abutment, as well as changing the material.

Crack Growth Analysis due to PWSCC in Dissimilar Metal Butt Weld for Reactor Piping Considering Hydrostatic and Normal Operating Conditions (수압시험 및 정상운전 하중을 고려한 원자로 배관 이종금속 맞대기 용접부 응력부식균열 성장 해석)

  • Lee, Hwee-Sueng;Huh, Nam-Su;Lee, Seung-Gun;Park, Heung-Bae;Lee, Sung-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.1
    • /
    • pp.47-54
    • /
    • 2013
  • This study investigates the crack growth behavior due to primary water stress corrosion cracking (PWSCC) in the dissimilar metal butt weld of a reactor piping using Alloy 82/182. First, detailed finite element stress analyses were performed to predict the stress distribution of the dissimilar metal butt weld in which the hydrostatic and the normal operating loads as well as the weld residual stresses were considered to evaluate the stress redistribution due to mechanical loadings. Based on the stress distributions along the wall thickness of the dissimilar metal butt weld, the crack growth behavior of the postulated axial and circumferential cracks were predicted, from which the crack growth diagram due to PWSCC was proposed. The present results can be applied to predict the crack growth rate in the dissimilar metal butt weld of reactor piping due to PWSCC.

Optimum Seeding Rate of Water Seeded Rice on Corrugated Paddy Surface in East Coastal Area (동해안 지역에서 벼 요철골 담수직파시 적정 파종량)

  • Lee, Jeom-Sig;Park, Sung-Tae;Lee, Kee-Yeong;Shin, Sang-Uk;Kim, Soon-Chul
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.5
    • /
    • pp.522-527
    • /
    • 1997
  • To find out the optimum seeding rate in corrugated water seeded rice, field experiment was carried out at Yeongdeog Substation of the National Yeongnam Agricultural Experiment Station for two years, 1994 and 1995. A rice cultivar Donghaebyeo, was seeded on May 15 with five seeding rate from 3kg /10a to 7kg /10a. The number of seedling stand per unit area was curvilinearly increased with seeding rate. In characteristics of rice plant associated with lodging, the plant height, fresh weight per tiller, Culm wall thickness and ratio of gravity center were not significantly different among seeding rates, but the breaking strength of 4th internode was slightly decreased with increasing seeding rate and thus, lodging index was generally greater at higher seeding rate than lower seeding rate. Field lodging was observed at 1~3 degree in seeding rate of 5~7kg /10a. Panicle number per unit area was generally increase with increase of seeding rate, while ratio of ripened grain was decreased with increase of spikelet number. Milled rice yield was curvilinearly increased with seeding rate. The optimum seeding rate in the highest rice yield was 4.8kg /10a in 1994, and 4.3kg /a in 1995, respectively.

  • PDF

Verification of the Radiation Shielding Analysis of Shipping Cask Using Deterministic and Probabilistic Methods (결정론적인 방법과 확률론적인 방법을 이용한 수송용기 방사선차폐해석의 비교 및 검증)

  • Yoon, Jeong-Hyoung;Lee, In-Koo;Bang, Kyoung-Sik;Choi, Byoung-Il;Kim, Chong-Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • In this study, to set-up the calculation method of radiation shielding of the KSC-4 shipping cask which is being used for spent fuel transportation, the pre-existing two calculation methods, deterministic and probabilistic methods were tested. For the first, the DOT4.2 computer code adopting the deterministic theory was applied for the calculation of effective neutron shielding under assumption of continuous wall thickness of the cask. To verify the first results, the probabilistic theory was used as an alternate calculation. In this case MCNP4A computer code adopting the probabilitic theory was used. And same approximation was obtained from the two different shielding calculations. From the results, it could be confirmed that the design and calculation method used for the radiation shielding of the KSC-4 was adequate and sufficiently safe to meet the design and QA requirements of 10CFR71 Appendix H.

  • PDF