• 제목/요약/키워드: thickness of wall

Search Result 1,571, Processing Time 0.029 seconds

Finite Element Analysis of the Monoleaflet Polymer to Minimize Stress and Displacement (응력 및 변위를 최소화하기 위한 단엽식 고분자 판막의 유한 요소 해석)

  • 한근조;안성찬
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.85-92
    • /
    • 1996
  • A monoleaflet polymer artificial heart valve which showed the remarkable improvement in pressure drop compared with other types of artificial valve was designed to minimize the deflection in vertical direction and the displacement of the valve tip in horizontal direction obtained by using finite element method as the location of the supporting members of the valve frame changed stress distribution change was also studied on each model generated by changing the distance between the frame and supporting members. It was found that by using the valve tip horizontal displacement the minimum valve thickness could be obtained in order to prevent the gap between the valve tip and the frame wall.

  • PDF

Evaluation of blood clot, platelet-rich plasma, and platelet-rich fibrin-mediated regenerative endodontic procedures in teeth with periapical pathology: a CBCT study

  • Swati Markandey;Haridas Das Adhikari
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.4
    • /
    • pp.41.1-41.20
    • /
    • 2022
  • Objectives: This study compared the clinical and radiological outcomes of regenerative endodontic procedures (REPs) using blood clots (BCs), platelet-rich plasma (PRP), and platelet-rich fibrin (PRF) through intraoral periapical radiography (IOPAR) and cone-beam computed tomography (CBCT). Materials and Methods: Forty-five single-rooted necrotic teeth with periapical pathology were randomly allocated to receive BC, PRP, or PRF as an individual scaffold. Outcomes were evaluated in 35 teeth in 23 patients with a follow-up period of 12-24 months through qualitative IOPAR scoring and quantitative CBCT measurements. Healing of periapical lesions and in immature teeth, changes in the apical foramen diameter (AFD), root wall thickness (RWT), and root length (RL) were assessed. A p value less than 0.05 was considered to indicate statistical significance. Results: All teeth were asymptomatic except 1 in the PRP group. Periapical lesion healing was seen in all except 2 teeth in the BC group and 3 in the PRP group. Both IOPAR and CBCT revealed no significant differences in bone healing or changes in AFD, RWT, and RL among the 3 groups. A positive pulp sensibility response to the cold test was seen in 2 teeth in the BC group, but none to the electric pulp test. Intracanal calcification (ICC) was evident in more teeth in the BC group than in the PRP and PRF groups, and was also significantly higher in immature teeth. Conclusions: Our results revealed that BC, PRP, and PRF have similar potential as scaffolds in REPs, and ICC may be a concern for long-term outcomes.

Effect of Dietary Lipids and Guar Gum on Lipid Metabolism in Ovariectomized Rats (식이지방의 종류와 Guar Gum의 첨가가 난소절제한 흰쥐의 지질대사에 미치는 영향)

  • 안혜선
    • Journal of Nutrition and Health
    • /
    • v.30 no.10
    • /
    • pp.1123-1131
    • /
    • 1997
  • This study examined the effect of dietary lipids and guar gum on lipid metabolism in ovariectomized rats. The experimental animals received ovarietomy (OVX). Lipids sources were divided into 3 groups (soybean oil(SB), beef tallow(BT)) and fish oil(FO)) and guar gum was supplemented to each lipid diet (SBG, BTG, FOG). Experimental diets were fed to therats for 16 weeks. Serum triglyceride (TG) levels were higher in the BT group and lower in the FO group as compared to the SB group .Serum total cholesterol (Tc) and HDL-C levels were lower in the FO group as compared to the SB group. Serum LDL-C and phospholipid levels were lower in the FO group as compared to the SB group. Serum lipids levels were lowered by guar gum supplement. Serum SFA(saturated fatty acids) contents were not significantly influenced by dietary lipids and guar gum. Serum MUFA(monounsaturated fatty acids) contents were the lowest in the SB group. Fecal weight was highest in the beef tallow group and lowest in the fish oil group. Fecal weight was increased by guar gum supplement in all lipid groups. Total bile acid content in feces was increased by guar gum supplement in the soybean oil and beef tallow groups. The endothelial cells of the beef tallow group changed from a flat shape to distorted round and enlarged shapes. The subendothelial layer was the thickness the thickest in the beef tallow group ; the interspace between elastic lamina was widened and elastic lamina was straightened and partly disrupted . The fish oil group showed more porminient endothelial cells and subendothelial layer. Internal elastic membrane and elastic lamina exhibited regularly wavy shapes. Guar gum supplement showed positive effects in all lipids groups. Based on the above results , it is suggested that beef tallow increased serum TG levels and injured the wall of the aorta. On the other hand, fish oil , which decreased serum lipid levels, has a positive effect on the walls of the aorta. Guar gum protects the aorta from injury by reducing the serum lipid levels. Therefore, it is suggested that soybean oil and beef tallow consumed with guar gum is beneficial.

  • PDF

Development of Leak and Vibration Monitoring System for High Pressure Steam Pipe by Using a Camera (카메라를 이용한 고압 증기 배관 누설/진동 감시시스템 개발)

  • Jeon, Hyeong-Seop;Suh, Jang-Su;Chae, Gyung-Sun;Son, Ki-Sung;Kim, Se-Oh;Lee, Nam-Hee
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.6
    • /
    • pp.496-503
    • /
    • 2016
  • Leakages at plant structures of power and petrochemistry plants have led to casualties and economic losses. These leakages are caused by fatigue failure of pipelines and their wall thickness. Vibration measurement methods for plant pipelines mainly use acceleration and laser sensors. These sensors are difficult to install and operate and thus lead to an increase in operational cost especially for wide area surveillance. Recently, measurements of leak and vibration displacements using cameras have attracted the interest of many researchers. This method has advantages such as simple installation, long distance monitoring, and wide area surveillance. Therefore, in this paper, we have developed a system that can measure the leakage and vibrational displacement by using a camera. Furthermore, the developed system was verified with experimental data.

AUTOMATIC MULTITORCH WELDING SYSTEM WITH HIGH SPEED

  • Moon, H.S;Kim, J.S.;Jung, M.Y.;Kweon, H.J.;Kim, H.S.;Youn, J.G.
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.320-323
    • /
    • 2002
  • This paper presents a new generation of system for pressure vessel and shipbuilding. Typical pressure vessel and ship building weld joint preparations are either traditional V, butt, fillet grooves or have narrow or semi narrow gap profiles. The fillet and U groove are prevalently used in heavy industries and shipbuilding to melt and join the parts. Since the wall thickness can be up to 6" or greater, welds must be made in many layers, each layer containing several passes. However, the welding time for the conventional processes such as SAW(Submerged Arc Welding) and FCAW(Flux Cored Arc Welding) can be many hours. Although SAW and FCAW are normally a mechanized process, pressure vessel and ship structures welding up to now have usually been controlled by a full time operator. The operator has typically been responsible for positioning each individual weld run, for setting weld process parameters, for maintaining flux and wire levels, for removing slag and so on. The aim of the system is to develop a high speed welding system with multitorch for increasing the production speed on the line and to remove the need for the operator so that the system can run automatically for the complete multi-torch multi-layer weld. To achieve this, a laser vision sensor, a rotating torch and an image processing algorithm have been made. Also, the multitorch welding system can be applicable for the fine grained steel because of the high welding speed and lower heat input compare to a conventional welding process.

  • PDF

CT Follow-Up of Postoperative Bronchopleural Fistula: Risk Factors for Progression to Chronic Complicated Infection (수술 후 기관지 흉막루의 전산화단층촬영 추적 검사: 만성 복합성 감염 진행의 위험인자 분석)

  • Ji-Yeon Han;Ki-Nam Lee;Yoo Sang Yoon;Jihyun Lee;Hongyeul Lee;Seok Jin Choi;Hye Jung Choo;Jin Wook Baek;Young Jin Heo;Gi Won Shin;Jinyoung Park;Dasom Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.1
    • /
    • pp.128-138
    • /
    • 2021
  • Purpose We evaluated the risk factors for progression to chronic complicated bronchopleural fistula (BPF) after pulmonary resection using follow-up CT. Materials and Methods We retrospectively reviewed 45 cases with BPF that had undergone pulmonary resection during 2010-2018. We compared the clinical and radiological characteristics of those with complicated BPF (n = 24) and those without complicated (sterilized) BPF (n = 21). The clinical and radiological risk factors for progression to chronic complicated BPF were examined by logistic regression analysis. Results The thickness of the pleural cavity wall (p = 0.022), the size of the pleural cavity (p = 0.029), and the size increase of BPF on follow-up (p = 0.012) were significantly different between the two groups. The risk factors for progression to chronic complicated BPF were age > 70 years (odds ratio, 6.43; 95% confidence interval, 1.2-33.7), the thickness of the cavity wall > 5 mm (odds ratio, 52.5; 95% confidence interval, 5.1-545.4), and an increase in the size of the pleural cavity on follow-up CT (odds ratio, 12.5; 95% confidence interval, 2.1-73.5), only in the univariate analysis. Conclusion The risk factors for progression to chronic complicated BPF can be evaluated using follow-up CT.

A Development of Tapered Metallic Microneedle Array for Bio-medical Application (생체의학에 적용 가능한 테이퍼형태의 금속성 마이코로니들 어레이의 개발)

  • Che Woo Seong;Lee Jeong-Bong;Kim Kabseog;Kim Kyunghwan;Jin Byung-Uk
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.59-66
    • /
    • 2004
  • This paper presents a novel fabrication process for a tapered hollow metallic microneedle array using backside exposure of SU-8, and analytic solutions of critical buckling of a tapered hollow microneedle. An SU-8 meta was formed on a Pyrex glass substrate and another SU-8 layer, which was spun on top of the SU-8 mesa, was exposed through the backside of the glass substrate. An array of SU-8 tapered pillar structures. with angles in the range of $3.1^{\circ}{\sim}5^{\circ}$ was formed on top of the SU-8 mesa. Conformal electrodeposition of metal was carried out followed by a mechanical polishing using a pianarizing polymeric layer. All organic layers were then removed to create a metallic hollow microneedle array with a fluidic reservoir on the backside. Both $200{\mu}m\;and\;400{\mu}m$ tall, 10 by 10 arrays of metallic microneedles with inner diameters of the tip in the range of $33.6{\sim}101\;{\mu}m$ and wall thickness of $10{\mu}m\;-\;20{\mu}m$ were fabricated. Analytic solutions of the critical buckling of arbitrary-angled truncated cone-shaped columns are also presented. It was found that a single $400{\mu}m$ tall hollow cylindrical microneedle made of electroplated nickel with a wall thickness of $20{\mu}m$, a tapered angle of $3.08^{\circ}$ and a tip inner diameter of $33.6{\mu}m$ has a critical buckling force of 1.8 N. This analytic solution can be used for square or rectangular cross-sectioned column structures with proper modifications.

  • PDF

CT-Derived Deep Learning-Based Quantification of Body Composition Associated with Disease Severity in Chronic Obstructive Pulmonary Disease (CT 기반 딥러닝을 이용한 만성 폐쇄성 폐질환의 체성분 정량화와 질병 중증도)

  • Jae Eun Song;So Hyeon Bak;Myoung-Nam Lim;Eun Ju Lee;Yoon Ki Cha;Hyun Jung Yoon;Woo Jin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.5
    • /
    • pp.1123-1133
    • /
    • 2023
  • Purpose Our study aimed to evaluate the association between automated quantified body composition on CT and pulmonary function or quantitative lung features in patients with chronic obstructive pulmonary disease (COPD). Materials and Methods A total of 290 patients with COPD were enrolled in this study. The volume of muscle and subcutaneous fat, area of muscle and subcutaneous fat at T12, and bone attenuation at T12 were obtained from chest CT using a deep learning-based body segmentation algorithm. Parametric response mapping-derived emphysema (PRMemph), PRM-derived functional small airway disease (PRMfSAD), and airway wall thickness (AWT)-Pi10 were quantitatively assessed. The association between body composition and outcomes was evaluated using Pearson's correlation analysis. Results The volume and area of muscle and subcutaneous fat were negatively associated with PRMemph and PRMfSAD (p < 0.05). Bone density at T12 was negatively associated with PRMemph (r = -0.1828, p = 0.002). The volume and area of subcutaneous fat and bone density at T12 were positively correlated with AWT-Pi10 (r = 0.1287, p = 0.030; r = 0.1668, p = 0.005; r = 0.1279, p = 0.031). However, muscle volume was negatively correlated with the AWT-Pi10 (r = -0.1966, p = 0.001). Muscle volume was significantly associated with pulmonary function (p < 0.001). Conclusion Body composition, automatically assessed using chest CT, is associated with the phenotype and severity of COPD.

Multi-element Ultrasound Applicator for the Treatment of Cancer in Uterus and Cervix (자궁암 치료용 다채널 초음파 온열치료기)

  • Lee Rena
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.16-23
    • /
    • 2005
  • The objective of this study was to construct multi-element ultrasound applicators for the treatment of gynecologic cancer with high dose rate brachytherapy. For the treatment of uterus, piezo-ceramic crystal transducer (PZT -5A) with outer diameter of 4 mm, wall thickness of 1.3 mm, and length of 24.5 mm was selected. For the treatment of cervix or vagina, it should be possible to insert the applicator into the vagina. Thus, a cylindrical PZT -8 material with outer diameter of 24.5 mm, wall thickness of 1.3 mm, and length of 15.2 mm was selected. The operating frequencies determined by vector impedance measurement were 3.2 MHz for the PZT 5A cylinder (OD=4 mm) and 1.7 MHz for the PZT -8 cylinder (OD: 24.5 mm). The ratios of generated acoustic output power to applied electric power were 33% and 61% for the tandem type crystal and the cylinder type crystal, respectively. The radiated acoustic pressure fields from both transducers were calculated using a Matlab code and measured in water using hydrophone. There was good agreement between measured and calculated acoustic pressure field distribution. For a tandem type transducer, the calculated acoustic pressure field decreased from 0.023 MPa at 10 mm to 0.010 Mpa at 30 mm, the reduction of 57%. For the cylinder type transducer which will be used for the treatment of vagina showed 78% reduction at 15 mm and 66% at 25 mm as compared to values at 5 mm from the surface. Based on the characteristics of the transducers, this study demonstrated the possibility of using the crystals as a heating source. Finally, a 3-element and 4-element prototype applicators were constructed. The 3-element applicator is 75 mm long and 4 mm thick and will be used for the treatment of uterus. The 4-element applicator is 61 mm long and 24.5 mm thick and will be used for the treatment of vagina. Using these applicators, it is possible to generate enough power to increase temperature to therapeutic level.

  • PDF

Clinical Courses of Cavitary Lesions in Pulmonary Tuberculosis (처음 진단시 발견된 공동성병변의 경과)

  • Park, Seung-Kyu;Choi, In-Hwan;Song, Sun-Dae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.323-330
    • /
    • 1996
  • Objective : Cavitary lesion in pulmonary tuberculosis sometimes makes problems in the course of treatment. Especially, retreatment cases tend to respond poorly to current antituberculosis agents. So, authors tried to render a guideline for clinical approach toward cavitary lesions in pulmonary tuberculosis. Methods : Retrospective analysis of 33 pulmonary tuberculosis patients with cavitary lesions was made. All the patients had got treatment at National Masan Tuberculosis Hospital from Jan. 1995 to Aug. 1995. Results: The ratio between male and female was 10:1. Age distribution was 69.7% in 3rd and 4th decades. The locations of cavitary lesion were 60.6% in right upper lung field and 36.4% in left upper lung field. In the extent of disease, there were 12 cases(36.4%) in moderate advanced and 21 cases in far advanced. Cavitary lesions were closed in 5 eases and remained in 28 eases. In the cases of closed cavity, it was happened within $10.6{\pm}4.72$ months after they took treatment, the size of cavity was $35.5{\pm}17.1$ in long diameter, $27.0{\pm}12.2$ in short diameter and $4.6{\pm}2.1\;mm$ in wall thickness. In the cases of remained cavity, the size of cavity was $31.9{\pm}12.3$ in long diameter, $21.0{\pm}9.8$ in short diameter and $5.04{\pm}2.0\;mm$ in wall thickness. In terms of negative conversion, it took $3.8{\pm}2.17$ months in the case of closed cavity but it was happened within 5 months for only 4 patients in the case of remained cavity. In the point of past medication history, there was none in closed cavities but there were none in 1 case, once in 3 cases, two times in 9 cases and more than three times in 13 cases among remained cavitary lesions. Conclusion : In the retreatment cases of pulmonary tuberculosis with cavitary lesions, they tend to respond poorly to current antituberculosis agents. So, if the lesions are localized, operative intervention may be a proper method as adjunctive treatment.

  • PDF