• 제목/요약/키워드: thermopile

검색결과 63건 처리시간 0.026초

3-5 $\mu m$ 적외선 흡수체를 가진 전면 건식 식각된 서모파일과 NDIR $CO_2$ 가스 센서의 응용 (A Front-side Dry-Etched Thermopile Detector with 3-5 $\mu m$ Infrared Absorber and Its Application to Novel NDIR $CO_2$ Gas Sensors)

  • 유금표;김시동;최우석;;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1470-1471
    • /
    • 2008
  • We present a front-side micromachined thermopile with high sensitivity in the 3-5${\mu}m$ window, and discuss its application to a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. The micromachined thermopile shows a measured sensitivity of 30 mV/W and a $D^*$ of $0.3{\times}10^8cm^{\surd}Hz/W$. Using this newly fabricated thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

열전대를 이용한 미세 열유속 센서의 제작 및 평가 (Fabrication and evaluation of a micro heat flux sensor using thermopile)

  • 김정훈;김범석;조형희;김용준
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1210-1213
    • /
    • 2005
  • Micro heat flux sensor is used in various industries to measure heat flux. In this study, a micro heat flux sensor is fabricated using the MEMS (Micro Electro Mechanical Systems) techniques. The fabricated sensor is composed in thermopile for sensor and SU-8 for thermal resistance layer. The new method of fabrication SU-8 is proposed in this study. The sensitivity is $44\;\mu{V/(W/cm^2)}$ at steady state and Reynolds number is 91322.

  • PDF

일사계 교정기법에 관한 연구 (A Study on the Calibration Techniques for Thermopile Pyranometer)

  • 조덕기;강용혁
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.161-166
    • /
    • 2008
  • The major purpose of this paper is to develop an uncertainty estimate for the calibration of thermopile instruments used to measure solar radiation parameters. We briefly describe the solar radiation parameters most often measured, instrumentation, reference standards, and calibration techniques. The bulk of the paper describes elemental sources of error and their magnitude. We then apply a standard error analysis methodology to combine these elemental error estimates into a statement of total uncertainty for the instrument calibration factor. Our results allow one to evaluate the accuracy of a radiometric measurement using thermopile instrumentation in the light of the application, such as engineering test evaluation or for validation of theoretical models.

  • PDF

일사계 교정을 위한 불확실성 분석에 관한 연구 (A Study on the Uncertainty Analysis for Thermopile Pyranometer Calibrations)

  • 조덕기;전일수;전명석;강용혁;오정무
    • 한국태양에너지학회 논문집
    • /
    • 제21권3호
    • /
    • pp.25-32
    • /
    • 2001
  • The major purpose of this paper is to develop an uncertainty estimate for the calibration of thermopile instruments used to measure solar radiation parameters. We briefly describe the solar radiation parameters most often measured, instrumentation, reference standards, and calibration techniques. The bulk of the paper describes elemental sources of error and their magnitude. We then apply a standard error analysis methodology to combine these elemental error estimates into a statement of total uncertainty for the instrument calibration factor. Our results allow one to evaluate the accuracy of a radiometric measurement using thermopile instrumentation in the light of the application, such as engineering test evaluation or for validation of theoretical models.

  • PDF

써모파일 센서를 이용한 NDIR CO2 가스검출기의 개발 (Development of NDIR CO2 Gas Detector Using Thermopile Sensor)

  • 조시형;박찬원
    • 산업기술연구
    • /
    • 제32권A호
    • /
    • pp.35-38
    • /
    • 2012
  • We present a novel non-dispersive infrared (NDIR) $CO_2$ gas sensor with a light source emitting collimated light. Using this thermopile, we also have successfully developed a small, sensitive NDIR $CO_2$ detector module for accurate air quality monitoring systems in energy-saving building and automotive applications. The novel sample cavity comprising specular reflectors around the light bulb is configured to uniformly emit collimated light into the entrance aperture of the cavity in order to enhance the sensitivity of NDIR $CO_2$ detector.

  • PDF

서모파일 어레이 센서를 이용한 무선 인체 감지 시스템 설계 (Implementation of Wireless Human Movement Detection System using Thermopile Array Sensor)

  • 이민구;박용국;정경권
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 추계학술대회
    • /
    • pp.857-860
    • /
    • 2014
  • 본 논문에서는 서모파일 어레이 센서를 이용한 무선 인체 감지 시스템을 제안한다. 제안한 시스템은 천정에 센서를 부착하여 온도 분포라고 불리는 공간의 온도를 측정한다. 시스템은 $4{\times}4$ 픽셀의 온도 분포를 측정하여 인체의 움직임을 추출할 수 있도록 분석된다. 실험 결과에서 제안한 시스템은 인체 움직임을 성공적으로 감지하였다.

  • PDF

Thermopile과 삽입된 $SnO_2$ catalyst를 이용한 NOx 센서 (A NOx gas sensor based on thennopile and embedded tin oxide catalyst)

  • 이충일;윤승일;김용준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1829-1832
    • /
    • 2008
  • This paper reports a novel gas sensing method by using a thermoelectric device, thermopile in this case, with an embedded tin oxide catalyst. By using a thin catalyst film, the response time and recovery time were remarkably improved. The fabricated gas sensor was characterized through detecting NOx gas with various concentrations.

  • PDF

Evaluation of Body Movement during Sleep with a Thermopile, Wavelets and Neuro-fuzzy Reasoning

  • Yoon, Young-Ro;Shin, Jae-Woo;Lee, Hyun-Sook;Jose C.Principe
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권1호
    • /
    • pp.5-10
    • /
    • 2004
  • 체동은 수면 분석에 있어서 중요한 변수중의 하나이다. 본 연구에서는 수면 중에 발생하는 체동을 비접촉 방식으로 검출하기 위하여 4채널의 써모파일 검출기를 구현하였으며, 써모파일 센서를 이용한 방식의 체통 검출 가능성을 확인하기 위해 열적외선 카메라를 통해 획득한 영상을 써모파일의 수학적 모델에 적용하였다 합성된 체동 신호는 Haar 웨이브렛을 이용하여 변환함으로써 체통이 발생한 시점과 움직임의 크기를 상체 및 하체로 나누어 순간 체동을 검출하였다. 또한 뉴로-퍼지 알고리즘인 ANFIS를 이용하여 발생한 체동이 상체만 움직인 것인지 또는 하체만 움직인 것인지 또는 몸 전체가 움직인 것인지에 대한 부위별 체동을 검출하였고, 총 3명의 피험자에 대해 60분간의 데이터를 획득하여 실험한 결과 순간 체동과 부위별 체통에 대해 각각 평균 96.3%와 39.2% 의 검출률을 나타냈다.