• 제목/요약/키워드: thermoelectric cooler

검색결과 42건 처리시간 0.023초

열전냉각 모듈을 이용한 국소 냉각에 관한 연구 (A Study on the Hot Spot Cooling Using Thermoelectric Cooler)

  • 김욱중;이공훈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.640-645
    • /
    • 2007
  • An experimental apparatus to show the hot spot cooling of an IC chip using a thermoelectric cooler is developed. The spot heating in very small area is achieved by the applying CO$_2$ laser source and temperatures are measured using miniature thermocouples. The active effects of thermoelectric cooler on the hot spot cooling system such as rapid heat spreading in the chip and lowering the peak temperature around the hot spot region are investigated. The experimental results are simulated numerically using the TAS program, which the performance characteristics such as Seebeck coefficient, electrical resistance and thermal conductivity of the thermoelectric cooler are searched by trial and error. Good agreements are obtained between numerical and experimental results if the appropriate performance data of the thermoelectric cooler are given.

  • PDF

마이크로 열전냉각기의 열성능에 대한 열전소자 두께의 영향 (Effect of the Thermoelectric Element Thickness on the Thermal Performance of the Thermoelectric Micro-Cooler)

  • 이공훈;김욱중
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.211-217
    • /
    • 2006
  • The three-dimensional numerical analysis has been carried out to figure out the effect of the thermoelectric element thickness on the thermal performance of the thermo-electric micro-cooler. The small-size and column-type thermoelectric cooler is considered. It is known that tellurium compounds currently have the highest cooling performance around the room temperature. Thus, in the present study, $Bi_{2}Te_{3}$ and $Sb_{2}Te_{3}$ are selected as the n- and p-type thermoelectric materials, respectively. The thermoelectric leg considered is less than $20{\mu}m$ thick. The thickness of the leg may affect the thermal and electrical transport through the interfaces between the leg and metal conductors. The effect of the thermoelectric element thickness on the thermal performance of the cooler has been investigated with parameters such as the temperature difference, the current, and the cooling power.

박막형 열전 소자를 이용한 Chip-on-Board(COB) 냉각 장치의 설계 (A Design of Thin Film Thermoelectric Cooler for Chip-on-Board(COB) Assembly)

  • 유정호;이현주;김남재;김시호
    • 전기학회논문지
    • /
    • 제59권9호
    • /
    • pp.1615-1620
    • /
    • 2010
  • A thin film thermoelectric cooler for COB direct assembly was proposed and the COB cooler structure was modeled by electrical equivalent circuit by using SPICE model of thermoelectric devices. The embedded cooler attached between the die chip and metal plate can offer the possibility of thin film active cooling for the COB direct assembly. We proposed a driving method of TEC by using pulse width modulation technique. The optimum power to the TEC is simulated by using a SPICE model of thermoelectric device and passive components representing thermal resistance and capacitance. The measured and simulated results offer the possibility of thin film active cooling for the COB direct assembly.

열전 냉각기의 모델링 및 열전달 해석에 대한 연구 (A Study about the Modelling of Thermoelectric Cooler and the Thermal Transfer Analysis)

  • 고윤석
    • 한국전자통신학회논문지
    • /
    • 제9권11호
    • /
    • pp.1291-1296
    • /
    • 2014
  • 열전 냉각기는 냉온 정밀온도제어가 가능하고, 소형화 및 경량화가 가능할 뿐만 아니라 기계적인 진동이 없어 신뢰성을 높일 수 있다는 장점 때문에 다양한 분야에 적용이 시도되고 있다. 하지만 열적 모델링 및 해석이 요구되기 때문에 적용분야에 최적한 열전 냉각기를 설계하는 것은 쉽지 않다. 따라서 본 연구에서는 SINDA/FLUINT 해석법을 이용하여 열전 냉각기 모델링과 크기 결정 문제 그리고 열적해석 등을 연구함으로서 열전 냉각기의 적용을 위한 기반기술을 확립하고자 한다.

열전 냉각기의 최적 설계를 위한 열전달 해석 (Heat Transfer Analysis for Optimum Design of a Thermoelectric Cooler)

  • 김제익;박찬형;강용태;최창균
    • 설비공학논문집
    • /
    • 제15권11호
    • /
    • pp.889-894
    • /
    • 2003
  • The objectives of this study are to present a proper mathematical model for a thermoelectric cooler equipped with the spacer and to investigate the effect of its geometries by heat transfer analysis. In order to enhance the efficiency of the thermoelectric cooler, the spacer is inserted between TEM (thermoelectric module) and cold plate. The theoretical results show that the COP (coefficient of performance) increases nonlinearly as high as 0.63 with increasing the depth of spacer and the depth of TEM and with decreasing the area of insulator.

열전 냉각기를 포함하는 볼로미터 패키지의 SPICE 등가 모델링 (SPICE-Compatible Modeling of a Microbolometer Package Including Thermoelectric Cooler)

  • 한창석;박승만;김남환;한승오
    • 센서학회지
    • /
    • 제22권1호
    • /
    • pp.44-48
    • /
    • 2013
  • For a successful commercialization of microbolometer, it is required to develop a robust package including thermal stabilizing mechanism. In order to regulate the temperature within some operating range, thermoelectric cooler is generally used but it's not easy to model the whole package due to the coupled physics nature of thermoelectric cooler. In this paper, SPICE-compatible modeling methodology of a microbolometer package is presented, whose steady-state results matched well with FEM results at the maximum difference of 5.95%. Although the time constant difference was considerable as 15.7%, it can be offset by the quite short simulation time compared to FEM simulation. The developed model was also proven to be useful for designing the thermal stabilizer through parametric and transient analyses under the various working conditions.

열전 냉각기가 집적된 레이저 다이오드 (Design and Fabrication of Laser Diode Integrated with Peltier Cooler)

  • 이상일;박정호
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.159-165
    • /
    • 1995
  • A double-heterostructure mesa-stripe-geometry laser diode integrated with thermoelectric Peltier cooler has been designed and fabricated. Epi-layers have been grown by metal organic chemical vapor deposition(MOCVD) method. Peltier cooling effect has been measured for devices with a mesa width of 14$\mu$m and a cavity length of 380$\mu$m. The effects of thermoelectric cooling could be shown by measuring the optical output of the laser with the increase of the current in the thermoelectric cooler. While the input courrent of the laser was maintained at 250mA, the optical output was decreased from 4.8mW to 3.8mW due to heating, but with the thermoelectric cooler on the optical output power was recovered by more than 40%. The results show that the complicated cooling device is not needed since the cooling can be achevied by the developement of the fabrication processing.

  • PDF

상용차용 캐빈냉방기의 전산 열유동 해석 (Computational Thermal Flow Analysis of a Cabin Cooler for a Commercial Vehicle)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.17-23
    • /
    • 2012
  • The steady three-dimensional computational thermal flow analysis using standard k-${\varepsilon}$ turbulence model was carried out to investigate the heat transfer characteristics of a cabin cooler for a commercial vehicle. The heat exchanging method of this cabin cooler is to use the cooling effect of a thermoelectric module. In view of the results so far achieved, the air system resistance of a cabin cooler is about 12.4 Pa as a static pressure, and then the operating point of a cross-flow fan considering in this study is formed in the comparatively low flowrate region. The air temperature difference obtained from the cold part of an thermoelectric module is about $26^{\circ}C$, and the cooling water temperature difference obtained from the hot part of an thermoelectric module is about $3.5^{\circ}C$.

열전박막을 이용한 마이크로 냉각소자 제작 (Fabrication of a Micro Cooler using Thermoelectric Thin Film)

  • 한승우;최현주;김병일;김병민;김동호;김욱중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회A
    • /
    • pp.1459-1462
    • /
    • 2007
  • In general a thermoelectric cooler (TEC) consists of a series of P type and N type thermoelectric materials sandwiched between two wafers. When a DC current passes through these materials, three different effects take place; Peltier effect, Joule heating effect and heat transfer by conduction due to temperature difference between hot and cold plates. In this study we have developed a micro TEC using $Bi_2Te_3$ (N type) and $Bi_{0.5}Sb_{1.5}Te_3$ (P type) thin films. In order to improve that performance of a micro TEC, we made 10 um height TE legs using special PR only for lift-off. We measured COP (coefficient of performance) and temperature difference between hot and cold connectors with current.

  • PDF

Transient cooling operation of multistage thermoelectric cooler (TEC)

  • Park, Jiho;Jeong, Sangkwon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제23권3호
    • /
    • pp.55-59
    • /
    • 2021
  • A thermoelectric cooler (TEC) is promising as an alternative refrigeration technology for the sake of its inherent advantages; no-moving parts and refrigerant-free in its operation. Due to the compactness, reliability and excellence in temperature stability, TECs have been widely used for small cooling devices. In recent years, thermoelectric devices have been attractive technologies that not only serve the needs of cooling and heating applications but also meet the demand for energy by recycling waste heat. In this research paper, multistage TEC is proposed as a concept of demonstrating the idea of transient cooling technology. The key idea of transient cooling is to harnesses the thermal mass installed at the interfacial level of the stages. By storing heat temporally at the thermal mass, the multistage TEC can readily reach lower temperatures than that by a steady-state operation. The multistage TEC consists of four different sizes of thermoelectric modules and they are operated with an optimized current. Once the cold-part of the uppermost stage is reached at the no-load temperature, the current is successively supplied to the lower stages with a certain time interval; 25, 50 and 75 seconds. The results show the temperatures that can be ultimately reached at the cold-side of the lowermost stage are 197, 182 and 237 K, respectively. It can be concluded that the timing or total amount of the current fed to each thermoelectric module is the key parameter to determine the no-load temperature.