• Title/Summary/Keyword: thermal stimulus

Search Result 43, Processing Time 0.025 seconds

Thermal Pain and Thermal Stimulus (열통과 열자극)

  • Kwak, Je-Hi;Kwak, Young-Sae
    • The Korean Journal of Physiology
    • /
    • v.7 no.1
    • /
    • pp.49-51
    • /
    • 1973
  • Denuded nerve fibers containing the node of Ranvier were prepared from the nerve innervating the gastrocnemius muscle of the frog. The effects of temperature rise of the medium surrounding the naked nerve fibers were studied upon the muscle response. A rise in temperature of the order of $50^{\circ}{\sim}90^{\circ}C$ was proved ineffective in the production of contractions in the muscle. It is thus concluded that the widespread concept that heating is one of the nerve stimuli is inadequate, and that thermal pain is the indirect effect of thermal stimuli. The authors' standpoint about thermal stimulus is that thermal stimulus or heating is one thing, cooling is another.

  • PDF

Effect of Pulse Magnetic Field Stimulus on Blood Flow using Digital Infrared Thermal Imaging (체열진단을 통한 펄스자기장 자극기의 혈류개선효과 고찰)

  • Lee, Hyun-Sook
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.5
    • /
    • pp.180-184
    • /
    • 2011
  • The changes in the blood flow in the peripheral vascular system under strong pulsed magnetic fields (pMF) were studied by digital infrared thermal imaging (DITI). After pMF stimulus temperatures in stimulated area were commonly increased in both groups of age and gender. In order to reduce heat generated from coil in pMF stimulus system plastic moldings were fabricated, so that certain distance was kept between stimulus system and the skin and to prevent direct contact to the skin. It is believed that skin temperature is increased by internal electromagnetic energy stimulated the peripheral vascular system by non-contact method.

Development of a Personal Compound Stimulus Device for Skin-care (개인용 피부미용 복합자극기 개발)

  • Lee, Jeon;Kim, Chi-Hyun;Chung, Geum-Hee
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • Recently, the market of skin-care device has been steadily growing up. In this paper, we tried to develop a personal compound stimulus device more competitive than existing products. As the compound stimulus, biochemical stimulus of herbal extraction fluid, thermal stimulus of plate-shaped carbon fiber heater, and optical stimulus of near infrared LED were selected. By some evaluation tests, the thermal stimulation part and the optical stimulation part were found to be developed properly. Additionally, the efficacy of the mixed stimulus of thermal and optical stimulation was tested in C2C12 mouse myoblast. Through RT-PCR analysis, it was found that, by the developed compound stimulus, the expression of collagen I mRNA and collagen III mRNA increased by 4.9 and 1.3 times respectively.

Comparison of Somatostatin and Morphine Action on the Responses of Wide Dynamic Range Cells in the Dorsal Horn to Peripheral Noxious Mechanical and Heat Stimulation in Cats

  • Jung, Sung-Jun;Choi, Young-In;Kim, Jun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.2
    • /
    • pp.155-163
    • /
    • 1998
  • The purpose of present study was to compare the effects of somatostatin (SOM) and morphine (Mor) on the responses of wide dynamic range (WDR) cells to peripheral noxious stimulation. Single neuronal activity was recorded with a carbon-filament electrode at the lumbosacral enlargement of cat spinal cord. After identifying WDR cells, their responses to peripheral noxious mechanical or thermal stimuli were characterized and the effects of SOM and Mor, applied either iontophoretically or intrathecally, were studied. In most cells SOM and Mor suppressed noxious stimulus-evoked WDR neuronal activity, though a few WDR neurons showed no change or were excited by SOM and Mor. Systemically applied naloxone, a non-specific opioid antagonist, always reversed the Mor induced suppression of neuronal activity evoked by noxious mechanical stimuli, but did not always reverse the suppression of neuronal activity elicited by SOM. The suppressive effect of Mor on thermal stimulus-evoked neuronal activity was partially reversed by naloxone, while that of SOM were not reversed at all. The above results suggest that both Mor and SOM exert an inhibitory effect on thermal and mechanical stimulus-evoked WDR neuronal activity in cat spinal dorsal horn, but the mechanisms are dependent upon the functional populations of dorsal horn nociceptive neurons.

  • PDF

Mild Cold Stimulus on Forehead of Healthy Men and Heart Rate Variability (이마의 냉각자극이 건강인의 심박 변이율에 미치는 영향에 대한 실험적 연구)

  • Kim Ki-Hwan;Park Kyung-Mo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1191-1194
    • /
    • 2005
  • The aim of this study was to investigate the change of Heart Rate Variability(HRV) that mild cold stimulus on the forehead of healthy men induces. 34 healthy male subjects participated in the experiments. On the first test series, 15 subjects were applied to the mild cold stimulus by the devise for cold stimulation. In the second test series, 10 subjects With heat Syndrome and 5 subjects With cold Syndrome were applied to the mild cold Stimulus. Aa a additional test, 4 subjects with cold syndrome were applied to the warm stimulus in the last test series. We analyzed the HRV through measuring electrocardiogram.(ECG). The result of this study is comparatively clear. In the first test series, mild cold stimulus made parasympathetic nervous system be activated. In the second test series, mild cold stimulus made parasympathetic nervous system be activated both in subjects with heat syndrome and subjects with cold syndrome, and heat syndrome shows more active parasympathetic nervous system rather than cold syndrome subjects do. In the last test series, 2 subjects with cold syndrome respond the mild cold stimulus. That means warm stimulus of cold condition subjects made parasympathetic nervous system active in 2 of 4 subjects. We found out that mild cold stimulus on forehead makes parasympathetic nervous system be activated in healthy male, and it can be interpreted that mild cold stimulus make healthy human be relaxed. Also, subjects have different fondness of thermal stimulus according to their Cold or Heat condition Preferences. Last test series shows that we need to investigate effect of the warm stimulus heat syndrome subjects.

Feasibility Study on the Use of the Thermal Sense as an Complementary Media for Pseudo-Aural Sense Display (유사 청감 재현 보조 매체로의 열감 활용 가능성 연구)

  • Oh, Hyun Suk;Kwak, Hyun Koo;Kim, Sung Mok;Cheong, Joono;Kim, Wheekuk;Choi, In Mook;Park, Yeon Kyu
    • Science of Emotion and Sensibility
    • /
    • v.15 no.4
    • /
    • pp.441-452
    • /
    • 2012
  • Recently, various researches have been attempted to effectively display pseudo-aural senses to the hearing-impaired or the deaf, using vibro-tactile stimulus as well as visual sense. Particularly, it is reported that as complementary senses to support the visual sense, tactile senses displayed by either speakers or vibration motors improve the reality sense significantly but do not nearly improve the emotional sense. Thus, in this study, the thermal sense is selected as another complementary sense to support the pseudo-aural sense display and it is investigated whether the thermal sense could generate a pseudo-aural sense or not. For this purpose, a thermal display module which could effectively display the desired thermal sense is implemented. Then, experiments have been conducted to subjects, which provide them with various types of stimuli combined with the aural, the vibrotactile, and the thermal stimuli along with the visual information. It can be confirmed, through statistical analysis on the data collected from experiments, that subjects could feel a pseudo-thermal sense closer to the real thermal sense which the normal subject feel from both the visual and the aural information, particularly either i) with the thermal stimulus along with the visual information or ii) with both the thermal and the vibrotactile stimuli along with the visual information than only with the visual information. Conclusively, it can be confirmed that the thermal stimulus applied to the skin of the subjects could play a role of effectively displaying pseudo-aural sense related to the thermal sense, as an complementary media for the pseudo-aural display.

  • PDF

The Difference of Grip Strength, Upper Limb Dexterity, and Hand Function according to Light Touch and Thermal Sensory Stimulus (촉각과 온각 자극에 따른 악력, 상지 기민성, 그리고 손 기능의 차이)

  • Rhee, Hyeon-Sook;Kim, Sung-Joong;Yu, Jae-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2644-2651
    • /
    • 2011
  • The purpose of this study was to investigate difference between grip strength, upper limb dexterity, and hand function according to touch and heat sensory stimulus. Forty healthy men were recruited. After obtaining subjects characteristics, examined grip strength, upper limb dexterity, and hand function, then we made touch sensory input using soft brush and tried the test again. Next day, we made thermal input using hot pack and did retest, too. The result showed significant differences appeared on every variable in grip strength and upper limb dexterity test (p<.001), and significant differences appeared on every variable except lifting small objects in hand function (p<.01). In conclusion, sensory input is to increase grip strength, upper limb dexterity, and hand function. The thermal sensory input has a tendency to increase grip strength, upper limb dexterity, and hand function than that of touch sensory input in effect of stimulus classification. The application of proper stimulus helps to facilitate upper limb and hand function in rehabilitation and in industrial field. So it is necessary to try more tests of frequency and intensity of stimulus.

Investigation of the Temperature Change and Quantity of Heat Stimulus of the Commercial Indirect Moxibustion (상용 간접구의 연소형태와 열자극량에 대한 연구)

  • Kwon, O-Sang;Lee, Sang-Hun;Cho, Sung-Jin;Choi, Kwang-Ho;Choi, Sun-Mi;Ryu, Yeon-Hee
    • Journal of Acupuncture Research
    • /
    • v.28 no.6
    • /
    • pp.139-147
    • /
    • 2011
  • Objectives : In this research, relatively the characteristic in the combustion according to the brands of the commercial indirect moxibustion is compared and the commercial indirect moxibustion is standardized and this result tries to be provided as necessary basic data. Methods : After adhering to the agarose gel surface in which the thermocouple is inserted, 6 kinds of commercial indirect moxibustion were burnt off and the burning behaviour of the commercial indirect device and heat quantity of stimulus was compared. Results : 1. The form of combustion did not have a difference in 6 kinds of commercial indirect moxibustion combustion. 2. As to the miximum temperature, 'Seoam' and 'Dongbang' was higher than 'Baekryoung' and 'Taeyang'. 3. It was long so that the highest temperature reaching time of 'Seoam' could note in comparison with the other brands. And the highest temperature reaching time of 'Baekryoung' was short to note in comparison with the other brands. 4. As to the quantity of heat stimulus, 'Seoam' was the biggest and 'Baekryoung' was the smallest. 5. The quantity of heat stimulus of 'Dongbang' was the most stable. Conclusions : In this research, relatively the form of combustion of 6 kinds of commercial indirect moxibustion and heat quantity of stimulus were compared. It desires to anticipate the result that it makes the skin.

Characteristics of Warm Acupuncture Reported in Experimental Studies: A Descriptive Narrative Review

  • Choi, Ji Won;Choi, Seo Young;Lee, Ji Sun;Yang, Gi Young
    • Journal of Acupuncture Research
    • /
    • v.36 no.3
    • /
    • pp.131-139
    • /
    • 2019
  • Background: This study aimed to investigate the correlation between heat transmission and intervention factors for warm acupuncture (such as features of acupuncture material and moxa, the treatment method, and clinical symptoms). Methods: Korean, English, Chinese and Japanese databases were analysed. Experimental studies that explored the association between thermal stimulation delivery and warm acupuncture intervention factors were included. The peak temperature, time to reach the peak temperature, and time of the effective stimulus, were set as the major parameters and analysed. Results: A total of 12 studies were included. Two studies were associated with the acupuncture needle material, 4 studies associated with the moxa mass, 1 study associated with the moxa density, 2 studies associated with the location of ignition, and 1 study associated with treatment environment were reviewed. The reporting quality of the 12 studies was low. Conclusion: This study provided limited information because of the heterogeneity of materials and parameters depending on each experiment. Further studies should clarify the correlation between heat transmission and intervention factors for warm acupuncture.

The Research of the HERO Test and Evaluation Technique (HERO 시험평가 기법 연구)

  • Shin, Seung-Je
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.76-83
    • /
    • 2007
  • This report presents the test technique using optic thermal sensor for the HERO evaluation of equipment installed EED. The calibration method of EED-thermal sensor assembly is explained by relation between the current in bridge wire and voltage in thermal sensor. And the HERO test and evaluation method is indicated based on MIL-STD-464A and MIL-STD-331C. The safety and reliability levels of EED-thermal sensor assembly are evaluated when exposed in the electromagnetic environment.