• Title/Summary/Keyword: thermal response test

Search Result 235, Processing Time 0.03 seconds

A Study of Borehole Thermal Behavior with 1-Dimensional Model;Field Test Analysis included (1차원 모델에 의한 보어홀 열거동 해석 및 현지측정)

  • Kim, Dae-Ki;Woo, Joung-Son;Ro, Jeong-Geun;Lee, Se-Kyoun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.550-554
    • /
    • 2007
  • A one-dimensional heat transfer model coupled with parameter estimation is developed in this study to predict the effective thermal conductivities of soil formation and borehole resistances from in situ field test data. In this application a new method of using initial ignoring time(IIT) obtained from error estimation is tried and turned out to be successful in determining soil thermal conductivities. The validity of this model is accomplished through comparison of the predicted temperature profiles of the model with the data from laboratory scale experimental setting. Eleven test boreholes were constructed in Ochang, Chungcheong Buk Do, and thermal response test was carried out with each borehole. The results of the in situ tests were analyzed with our 1-D numerical model and compared with the results of line source method. The comparison shows that the thermal properties from line source method is a little lower (${\sim}95%$)than those from numerical method. The reason of such result seems to be the lower thermal conductivity of grout material, which is not counted in line source method.

  • PDF

Thermal Conductivity Estimate of Ground Using Energy Piles (PHC 에너지 파일을 이용한 지반의 열전도도 산정)

  • Yoon, Seok;Go, Gyu-Hyun;Park, Hyun-Ku;Park, Skhan;Lee, Seung-Rae;Cho, Kyung-Jin;Song, Chi-Yong
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.8 no.4
    • /
    • pp.8-16
    • /
    • 2012
  • The use of energy pile foundation has been increased for economic utilization of geothermal energy. This paper describes an experimental and numerical study on thermal response tests (TRTs) using W and 3U-shaped ground heat exchangers (GHEs) in precast-high strength concrete (PHC) energy piles. Ground thermal conductivity and borehole thermal resistance were measured and compared with those numerical analysis. W-shpaed GHE showed higher heat transfer behavior than 3U-shaped one because of different conditions such as pile size and volume of grout. That is, ground thermal conductivity using W-shaped GHE was higher than that of 3U shaped GHE, and borehole thermal resistance vice versa. The relative error of borehole resistance values between numerical and analytical solution was less than 5%.

An Analysis on the Bleeding Effect of SCW Ground Heat Exchanger using Thermal Response Test Data (열응답시험 데이터를 이용한 SCW형 지중열교환기 블리딩 효과 분석)

  • Chang, Keun-Sun;Kim, Min-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.512-520
    • /
    • 2020
  • Recently, the applications of the standing column well (SCW) ground heat exchanger (GHX) have increased significantly in Korea as a heat transfer mechanism of ground source heat pump systems (GSHP) because of its high heat capacity and efficiency. Among the various design and operating parameters, bleeding was found to be the most important parameter for improving the thermal performance, such as ground thermal conductivity and borehole thermal resistance. In this study, a bleeding analysis model was developed using the thermal response test data, and the effects of bleeding rates and bleeding locations on the thermal performance of anSCW were investigated. The results show that, when the ground water flows into the top of anSCW, the time variation of circulating water temperature decreased with increasing bleeding rate, and the ground thermal conductivity increases by as much as 179% with a 30% bleeding rate. When the ground water flows into the bottom of the SCW, the circulating water temperatures become almost constant after the increase in the beginning time because the circulating water exchanges heat with the ground structure before mixing with the ground water at the bottom.

Thermal characteristics of energy textile by performing in-situ thermal response test (현장 열응답시험을 통한 에너지 텍스타일의 열적 거동 평가)

  • Lee, Chulho;Yoon, Sangbong;Han, Eunseon;Jeoung, Jae-Hyeung;Choi, Hangseok
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.167.2-167.2
    • /
    • 2010
  • 본 연구에서는 지열 에너지원으로써 터널 내부 벽면의 항온성을 이용하여 터널 외벽에 텍스타일 형태의 열교환기를 설치하고 열적 거동을 평가하였다. 터널의 라이닝 부분에서는 여러 가지 요인에 의해 지하수가 터널 내부로 유입하게 되므로 지하수의 유무에 대한 열적 거동 및 유동액의 순환 속도에 따른 영향, 열교환 파이프 배열 형태에 따른 영향을 현장 시험 시공과 현장 열응답시험을 통하여 평가하고자 하였다. 또한 3-D 유한체적해석 프로그램(FLUENT)을 이용하여 숏크리트와 라이닝의 열전도도를 고려한 열교환기의 성능을 분석하였다. 수치해석 결과 열교환 파이프 주변에 지하수의 흐름이 존재할 경우 열전달이 상대적으로 더 원활히 이루어졌으며 순환속도가 빠를 때 보다 느릴수록 효율이 높게 나타났다. 또한, 파이프의 간격이 넓을수록, 파이프의 길이가 길수록 효율이 높게 나타났다. 라이닝 및 숏크리트의 열전도도가 증가함에 따라 에너지 텍스타일의 열전달 효율이 높게 나타났다. 현장 시험을 통해 비슷한 길이의 파이프가 사용된 경우, 파이프 배열 형태에 따라 수평형보다는 수직형 배열의 효율이 높게 측정되었다.

  • PDF

A Study on Characteristics of Effective Thermal Conductivity of a horizontal Close-Loop Ground Heat Exchanger using in In-situ Thermal Response Test method (현장열응답 시험을 통한 수평형 지중열교환기의 지중열전도도 특성 연구)

  • Kim, Min-Jun;Choi, Choong-Hyun;Woo, Jeong-Tae;Chang, Keun-Sun;Choi, Youn-Sung;Lee, Hyun-Su;Kim, Ju-Houng
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.122.1-122.1
    • /
    • 2010
  • 수평형 지중열교환기의 지중온도 및 지중열전도도를 분석하기 위해서 경기테크노파크 화단에 수평형 지중열교환기를 설치하였다. 수평형 지중열교환기는 수평 길이 50m, 폭 2.7m, 깊이 2m에 파이프 규격 30mm, 파이프 길이 400m 1본을 매설하였다. 2009년 7월부터 2010년 5월까지 총 7회에 걸쳐 현장열응답방식을 이용하여 지중열전도도를 측정하였다. 측정결과를 분석해보면 수평형 지중열교환기의 지중온도는 계절적인 영향을 많이 받았으며, 지중열전도도는 계절적인 요인과는 무관하게 $1.51{\pm}0.1W/mk$ 범위에서 잘 일치함을 보였다. 이러한 결과로서 수평형 지중열교환기의 현장열응답시험은 현장설치 조건을 모두 반영한 결과를 도출할 수 있을 것으로 판단된다.

  • PDF

Numerical Analysis for Thermal Response of Silica Phenolic in Solid Rocket Motor (고체 로켓 추진기관에서 실리카/페놀릭 열반응 해석 연구)

  • Seo, Sangkyu;Hahm, Heecheol;Kang, Yoongoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2017.05a
    • /
    • pp.521-528
    • /
    • 2017
  • In this paper, the numerical analysis for heat conduction of silica/phenolic composite material, which is used for solid rocket nozzle liner or insulator, was conducted. 1-D Finite Difference Method for the analysis of silica/phenolic during the firing of solid rocket motor was used to calculate the heat conduction considering the surface ablation and the thermal decomposition. The boundary condition at the nozzle wall took into account the convective heat transfer, which was obtained by integration equation. The numerical results of the surface ablation and char depth were compared with the results of test motor that is TPEM-10. It was found that the result of calculation is favorably agreed with the thermal response of test motor.

  • PDF

Numerical Analysis for Thermal Response of Silica Phenolic in Solid Rocket Motor (고체 로켓 추진기관에서 실리카/페놀릭 열반응 해석 연구)

  • Seo, Sangkyu;Hahm, Heecheol;Kang, Yoongoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.76-84
    • /
    • 2018
  • In this paper, the numerical analysis for heat conduction of silica/phenolic composite material, used for solid rocket nozzle liners or insulators, is conducted. A 1-dimensional finite difference method for the analysis of silica/phenolic during the firing of a solid rocket motor is used to calculate heat conduction, considering surface ablation and thermal decomposition. The boundary condition at the nozzle wall, considering the convective heat transfer, is obtained via integration equations. The numerical results of the surface ablation and char depth are compared with the results of a TPEM-10 test motor, finding that the result of calculation agrees with the thermal response of the test motor.

A Study of Analgesic Effect of Twirling Acupuncture on Pain Model of the Formalin Test Using the Infrared Thermal Image Processing (적외선 영상 처리를 통한 Formalin Test 통증 모델에서의 염전 침자극 효과에 대한 연구)

  • Ryu, Jae-kwan;Lee, Soon-geul;Rhim, Sung-soo;Lee, Jae-dong;Min, Byung-il;Ryu, Un-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.2
    • /
    • pp.223-233
    • /
    • 2004
  • Objective: As a manual accupucture method, the twirling-needle treatment has been known more effective in relieving pain than the conventional simple accupuncture treatment. Finding a proper treatment condition is difficult because of the lack of a quantative measurement of the alleviation of pain made by acupuncture. In this research, the authors propose the use of infrared thermal images in a formalin test to quantatively verify the effect of twirling. Methods: After injecting 10%~20% formalin into the tail of rats, the infrared thermal images(ITI) have been obtained to estimate the thermal distribution caused by inflammation. The authors propose a processing method to measure the thermal distribution from the thermal images obtained from the infrared camera as a pain model of the formalin test. Results: The pain model obtained from the infrared thermal image has two phases. The first phase, which is a transient period, is the initial 20 minutes when the pain is developed after the formalin injection. The second phase, which is a steady state, is where the development of pain lasts for 60 minutes or more after the first stage. This characteristic of the proposed model based on ITI is consistent with that of the pain model reported by other researchers whose works are based on the time-course of flinching and licking/biting, following a different concentration of formalin. It is noticed that the response of the thermal distribution obtained from ITI shows very high correlation to the behavioral response in the formalin test performed by Kazuhiro Okuda and four others5). In addition, the authors propose an ITI method to determine the pain-reducing effect of the acupuncture. The thermal distribution obtained from the experiment shows that there is significant pain reducing effect made by the twirling-needle method.

  • PDF

Non-destructive Leakage Location Analysis Method in Substrate Behavior Response Testing of Waterproofing Membrane Systems using Thermal Emission Camera

  • Oh, Kyu-Hwan;Jiang, Bo;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.11a
    • /
    • pp.47-48
    • /
    • 2017
  • The substrate behavior response testing outlined in KS F 2622 evaluates the leakage cause of waterproofing membrane systems when subjected to the concrete joint load behaviors by removing the waterproofing layer after testing, relying mostly on visual observation and subjective analysis. A non-destructive leakage cause and failure type analysis method is proposed currently in this study by the means of detecting leakage paths using thermal emission imaging systems. Test specimens are placed in varying temperature conditions after the concrete joint movement testing and are scanned using the thermal emission camera to determine the location and dimension of the adhesion failure/leakage path beneath the waterproofing membranes.

  • PDF