• Title/Summary/Keyword: thermal response test

Search Result 235, Processing Time 0.024 seconds

Research for Development of Thermal Comfort Uniforms of Workers on a Low Temperature Storage (저온창고 작업자의 열적 쾌적성 증진을 위한 유니폼 조사 연구 - 대형 할인 마트 종사자를 대상으로 -)

  • Yoo, Hwa-Sook
    • Fashion & Textile Research Journal
    • /
    • v.12 no.4
    • /
    • pp.513-522
    • /
    • 2010
  • The aim of this study is to investigate the actual state for the development of the thermally comfortable uniform for workers on a low temperature storage. Observation, interview and survey were executed focusing on the environment, clothing, and human factors which have effects on the comfort of workers. Of 400 distributed, 253 questionnaires were analyzed through descriptives, frequency, ANOVA, t-test, multi-response analysis, correlation analysis with SPSS 12.0. The results are following. Coming and going between a selling area and cold storages, the workers showed to experience a big temperature gap. They indicated to feel cold on face and hands which were not covered by clothing and have got sick because of low temperature. The workers wanted the uniform made of functional fabrics, especially heat insulation fabrics. Female workers rather than male workers, the older, and the longer their working period were, the more uncomfortable they revealed to feel. The workers who works on the daily products part or mainly on the freezer appeared to feel cold more than any other workers. In conclusion, it was found that the uniform which consider steady state and unsteady state heat transfer together must be developed.

Development of a Drought Detection Indicator using MODIS Thermal Infrared Data

  • Park, Sun-Yurp
    • Korean Journal of Remote Sensing
    • /
    • v.20 no.1
    • /
    • pp.1-11
    • /
    • 2004
  • Based on surface energy balance climatology, surface temperatures should respond to drying conditions well before plant response. To test this hypothesis, land surface temperatures (LST) derived from MODIS data were analyzed to determine how the data were correlated with climatic water balance variables and NDVI anomalies during a growing season in Western and Central Kansas. Daily MODIS data were integrated into weekly composites so that each composite data set included the maximum temperature recorded at each pixel during each composite period. Time-integrated, or cumulative values of the LST deviation standardized with mean air temperatures had significantly high correlation coefficients with SM, AE/PE, and MD/PE, ranging from 0.65 to 0.89. The Standardized Thermal Index (STI) is proposed in this study to accomplish the objective. The STI, based on surface temperatures standardized with observed mean air temperatures, had significant temporal relationships with the hydroclimatological factors. STI classes in all the composite periods also had a strong correlation with NDVI declines during a drought episode. Results showed that, based on LST, air temperature observations, and water budget analysis, NDVI declines below normal could be predicted as early as 8 weeks in advance in this study area.

An Analysis of Power System Stability(PSS) Effect with 135MVA Hydro Generator (135MVA 수력 발전기의 전력 시스템 안정화 장치 적용 효과 분석)

  • Ok, Yeon-Ho;Lee, Eun-Woong;Byun, Ill-Hwan;Oh, Sueg-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1100-1104
    • /
    • 2009
  • As national power consumption every year increases, the power plant which is in the process of planning tries to establish high-capacity generator. The power system tends to become a large size. With the progress of electronic components, the control systems of the generator have been digitalized and rapid-response control system is possible. However, the minute frequency vibration of grid occurred with the effect of rapid-response control system. To solve these problem, PPS(Power System Stability) has been introduced since 2004, and it has being installed and applied to the thermal and nuclear power plant which are high-capacity, over 800MVA. However the minute frequency vibration is gradually changed to the bigger frequency vibration by fast-action control system, and this regional frequency fluctuation might be diffused wide area. Therefore, it is applied to the hydro generator which is small with fast-action governor system, and it is necessary to control the minute frequency vibration to prevent to diffuse. In this paper, the effect will be proved by establishing PSS on the Hydro-Generator which has both digital excitation and governor system for the first time in Korea.

Thermo-mechanical behavior of prestressed concrete box girder at hydration age

  • Zhang, Gang;Zhu, Meichun;He, Shuanhai;Hou, Wei
    • Computers and Concrete
    • /
    • v.20 no.5
    • /
    • pp.529-537
    • /
    • 2017
  • Excessively elevated temperature can lead to cracks in prestressed concrete (PC) continuous bridge with box girder on the pier top at cement hydration age. This paper presents a case study for evaluating the behavior of PC box girder during the early hydration age using a two-stage computational model, in the form of computer program ANSYS, namely, 3-D temperature evaluation and determination of mechanical response in PC box girders. A numerical model considering time-dependent wind speed and ambient temperature in ANSYS for tracing the thermal and mechanical response of box girder is developed. The predicted results were compared to show good agreement with the measured data from the PC box girder of the Zhaoshi Bridge in China. Then, based on the validated numerical model three parameters were incorporated to analyze the evolution of the temperature and stress within box girder caused by cement hydration heat. The results of case study indicate that the wind speed can change the degradation history of temperature and stress and reduce peak value of them. The initial casting temperature of concrete is the most significant parameter which controls cracking of PC box girder on pier top at cement hydration age. Increasing the curing temperature is detrimental to prevent cracking.

PULSE OXIMETER AS A DIAGNOSTIC TEST OF PULP VITALITY (Pulse Oximeter를 이용한 치수생활력측정)

  • Koo, Bon-Kyung;Lee, Jae-Ho;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.1
    • /
    • pp.103-107
    • /
    • 2000
  • Traditionally, EPT and thermal tests were used as diagnostic methods for pulp vitality test. The thermal and electrical stimulation tests are the methods to determine the vitality of a tooth based on its neuronal response. These have certain limitations, one of them is the difficulty of approaching the correct result in case of treatment of children. The reason is management problem caused by the unpleasant stimulation. Also, the response from patients are not objective, and false positive or false negative could be happened. Recently, laser doppler flowmetry and pulse oximeter which evaluate vascular integrity are introduced in an effort of overcoming to limitation of traditional methods. The principle of pulse oximeter is to and out level of oxygen saturation by ratio of the two pulses between emitted light and detected light penetrating them to the termination of body, such as ears or fingers. From this point of view, it can be applied to a tooth to determine its vitality. The objective of this study lies mainly on varifying pulse oximeter as a method of determining tooth vitality and providing basic data of its clinical implementation. The result of the research showed that level of oxygen saturation in vital teeth was average of 96.3% and 0.0% in pulpless teeth. As a comprehensive result, pulse oximeter could be an useful diagnostic equipment in determining of tooth vitality.

  • PDF

Heat Acclimatization in Hot Summer for Ten Weeks Suppress the Sensitivity of Sweating in Response to Iontophoretically-administered Acetylcholine

  • Lee, Jeong-Beom
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.12 no.6
    • /
    • pp.349-355
    • /
    • 2008
  • To determine the peripheral mechanisms involved in thermal sweating during the hot summers in July before acclimatization and after acclimatization in September, we evaluated the sweating response of healthy subjects (n=10) to acetylcholine (ACh), a primary neurotransmitter involved in peripheral sudomotor sensitivity. The quantitative sudomotor axon reflex test (QSART) measures sympathetic C fiber function after iontophoresed ACh evokes a measurable reliable sweat response. The QSART, at 2 mA for 5 min with 10% ACh, was applied to determine the directly activated (DIR) and axon reflex-mediated (AXR) sweating responses during ACh iontophoresis. The AXR sweat onset-time by the axon reflex was $1.50{\pm}0.32$ min and $1.84{\pm}0.46$ min before acclimatization in July and after acclimatization in September, respectively (p<0.01). The sweat volume of the AXR(l) [during 5 min 10% iontophoresis] by the axon reflex was $1.45{\pm}0.53\;mg/cm^2$ and $0.98{\pm}0.24\;mg/cm^2$ before acclimatization in July and after acclimatization in September, respectively (p<0.001). The sweat volume of the AXR(2) [during 5 min post-iontophoresis] by the axon reflex was $2.06{\pm}0.24\;mg/cm^2$ and $1.39{\pm}0.32\;mg/cm^2$ before and after acclimatization in July and September, respectively (p<0.001). The sweat volume of the DIR was $5.88{\pm}1.33\;mg/cm^2$ and $4.98{\pm}0.94\;mg/cm^2$ before and after acclimatization in July and September, respectively (p<0.01). These findings suggest that lower peripheral sudomotor responses of the ACh receptors are indicative of a blunted sympathetic nerve response to ACh during exposure to hot summer weather conditions.

Development of Nanomodified Snow-Melting Concrete Using Low-Temperature Phase-Change Material Impregnated Lightweight Aggregate (저온 상변화 물질 함침 경량골재를 이용한 나노 개질 융설 콘크리트 개발)

  • Kyoung, Joo-Hyun;Kim, Sean-Mi;Hu, Jong-Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.787-792
    • /
    • 2022
  • In winter, the excessive use of deicing salt deteriorates concrete pavement durability. To reduce the amount of deicing salt used, phase-change materials (PCMs) potentially offer an alternative way to melt snow through their latent heat storage characteristics. In this research, thermal energy storage concrete was developed by using PCM-impregnated expanded clay as 50 % replacement to normal aggregate by volume. In addition, to improve the thermal efficiency of PCM lightweight aggregate (PCM-LWA)-incorporated concrete, multi-walled carbon nanotubes (MWCNTs) were incorporated in proportions of 0.10 %, 0.15 %, and 0.20 % by binder weight. Compressive strength testing and programmed thermal cycling were performed to evaluate the mechanical and thermal responses of the PCM-LWA concrete. Results showed a significant strength reduction of 54 % due to the PCM-LWA; however, the thermal performance of the PCM-LWA concrete was greatly improved with the addition of MWCNTs. Thermal test results showed that 0.10 % MWCNT-incorporated concrete had high thermal fatigue resistance as well as uniform heat flow, whereas specimens with 0.15 % and 0.20 % MWCNT content had a reduced thermal response due to supercooling when the ambient temperature was varied between -5℃ and 10℃.

The Safety and Analgesic Effect of Datura Flos Pharmacopuncture in Sprague-Dawley Rats

  • Jun, Seungah;Lee, Yun Kyu;Lee, Bong Hyo;Kim, Jae Soo;Lee, Hyun-Jong
    • Journal of Acupuncture Research
    • /
    • v.36 no.3
    • /
    • pp.147-153
    • /
    • 2019
  • Background: The aim of this study was to investigate the safety and analgesic effects of Datura Flos pharmacopuncture (DFP). Methods: The analgesic effects of DFP were assessed using mechanical (hot plate), chemical (formalin test), and thermal (von Frey filament test) pain tests. Forty male Sprague Dawley rats were assigned randomly into DFP (75 mg/kg, 150 mg/kg), lidocaine 0.5%, or normal saline group for treatment on Kl3. Gross pathology, histopathology, biochemistry and hematology were performed. Results: In the hot plate test, DFP at a high dose (HDDFP; 150 mg/kg) produced a significant analgesic effect, at 10 and 20-minutes post injection (p < 0.01). Low dose DFP (LDDFP; 75 mg/kg) also showed an analgesic effect at 10 minutes post injection (p < 0.01). In the formalin test, HDDFP produced an analgesic effect, for 0-10 and 10-20 minutes (p < 0.01) post treatment, whereas LDDFP showed analgesic effects between 10-20 minutes (p < 0.05). In the von Frey filament test, DF-H produced an analgesic effect, 10 (p < 0.01) and 20 minutes post treatment (p < 0.05). LDDFP showed analgesic effect at 10 minutes (p < 0.05). In the acupuncture response test, HDDFP produced an analgesic effect at 10 minutes post treatment (p < 0.05). DF-H did not cause any anatomical changes to the liver or kidney and there were no abnormalities in biochemistry or hematology. Conclusion: DF-H was not toxic and provided short term analgesia, suggesting it may be useful in the management of pain.

Rotordynamic Performance Analysis and Operation Test of a Power Turbine for the Super critical CO2 Cycle Application (초임계 CO2 발전용 파워 터빈의 회전체 동역학 해석 및 구동 시험)

  • Lee, Donghyun;Kim, Byungok;Sun, Kyungho;Lim, Hyungsoo
    • Tribology and Lubricants
    • /
    • v.33 no.1
    • /
    • pp.9-14
    • /
    • 2017
  • This paper presents a rotordynamic analysis and the operation of a power turbine applied to a 250 kW super-critical $CO_2$ cycle. The power turbine consists of a turbine wheel and a shaft supported by two fluid film bearings. We use a tilting pad bearing for the power turbine owing to the high speed operation, and employ copper backing pads to improve the thermal management of the bearing. We conduct a rotordynamic analysis based on the design parameters of the power turbine. The dynamic coefficients of the tilting pad bearings were calculated based on the iso-thermal lubrication theory and turbine wheel was modeled as equivalent inertia. The predicted Cambell diagram showed that there are two critical speeds, namely the conical and bending critical speeds under the rated speed. However, the unbalance response prediction showed that vibration levels are controlled within 10 mm for all speed ranges owing to the high damping ratio of the modes. Additionally, the predicted logarithmic decrement indicates that there is no unstable mode. The power turbine uses compressed air at a temperature of $250^{\circ}C$ in its operation, and we monitor the shaft vibration and temperature of the lubricant during the test. In the steady state, we record a temperature rise of $40^{\circ}C$ between the inlet and outlet lubricant and the measured shaft vibration shows good agreement with the prediction.

Thermal-hydraulic Analysis of Operator Action Time on Coping Strategy of LUHS Event for OPR1000 (OPR1000형 원전의 최종열제거원 상실사고 대처전략 및 운전원 조치 시간에 따른 열수력 거동 분석)

  • Song, Jun Kyu
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.121-127
    • /
    • 2020
  • Since the Fukushima nuclear accident in 2011, the public were concerned about the safety of Nuclear Power Plants (NPPs) in extreme natural disaster situations, such as earthquakes, flooding, heavy rain and tsunami, have been increasing around the world. Accordingly, the Stress Test was conducted in Europe, Japan, Russia, and other countries by reassessing the safety and response capabilities of NPPs in extreme natural disaster situations that exceed the design basis. The extreme natural disaster can put the NPPs in beyond-design-basis conditions such as the loss of the power system and the ultimate heat sink. The behaviors and capabilities of NPPs with losing their essential safety functions should be measured to find and supplement weak areas in hardware, procedures and coping strategies. The Loss of Ultimate Heat Sink (LUHS) accident assumes impairment of the essential service water system accompanying the failure of the component cooling water system. In such conditions, residual heat removal and cooling of safety-relevant components are not possible for a long period of time. It is therefore very important to establish coping strategies considering all available equipment to mitigate the consequence of the LUHS accident and keep the NPPs safe. In this study, thermal hydraulic behavior of the LUHS event was analyzed using RELAP5/Mod3.3 code. We also performed the sensitivity analysis to identify the effects of the operator recovery actions and operation strategy for charging pumps on the results of the LUHS accident.