• 제목/요약/키워드: thermal response

검색결과 1,162건 처리시간 0.087초

Recognition of Material Temperature Response Using Curve Fitting and Fuzzy Neural Network

  • Ryoo, Young-Jae;Kim, Seong-Hwan;Chang, Young-Hak;Lim, Yong-Cheol;Kim, Eui-Sun;Park, Jin-Kyn
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제3권2호
    • /
    • pp.133-138
    • /
    • 2001
  • This paper describes a system that can used to recognize an unknown material regardless of the change of ambient tem-perature using temperature response curve fitting and fuzzy neural network(FNN). There are some problems to realize the recogni-tion system using temperature response. It requires too many memories to store the vast temperature response data and it has to be filtered to remove noise which occurs in experiment. And the temperature response is influenced by the change of ambient tempera-ture. So, this paper proposes a practical method using curve fitting the remove above problems of memories and nose. And FNN is propose to overcome the problem caused by the change of ambient temperature. Using the FNN which is learned by temperature responses on fixed ambient temperature and known thermal conductivity, the thermal conductivity of the material can be inferred on various ambient temperature. So the material can be recognized by the thermal conductivity.

  • PDF

Environmental stress-related gene expression and blood physiological responses in olive flounder (Paralichthys olivaceus) exposed to osmotic and thermal stress

  • Choi, Cheol-Young
    • Animal cells and systems
    • /
    • 제14권1호
    • /
    • pp.17-23
    • /
    • 2010
  • We isolated warm temperature acclimation-related protein 65-kDa (Wap65) cDNA from the liver of olive flounder and investigated the mRNA expression of Wap65 and HSP70 in olive flounder exposed to osmotic (17.5, 8.75, and 4 psu) and thermal stress (25 and $30^{\circ}C$). The mRNA expression of Wap65 and HSP70 was increased by thermal stress. The mRNA expression of HSP70 was also increased by osmotic stress, whereas no significant change in Wap65 expression was detected. These results indicate that Wap65 mRNA expression occurs specifically in response to increases in water temperature, but not in response to osmotic stress. Plasma cortisol levels were also increased by osmotic and thermal stress. We also utilized the stress hormone cortisol to examine whether Wap65 expression is thermal-stress-specific. Cortisol treatment increased HSP70 mRNA expression in vitro, but had no significant effect on Wap65 mRNA expression. Thus, thermal stress, but not osmotic stress, induces Wap65 expression.

폴리이미드 표면에서의 열적 스트레스에 의한 TN셀의 잔류 DC 특성 연구 (Study on the residual DC characteristic of Twisted Nematic liquid Crystal Display on the Polyimide Surface by the Thermal Stress)

  • 배유한;김상훈;황정연;강형구;이휘원;김종환;김영환;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.451-452
    • /
    • 2005
  • In this study, the threshold voltage and the response time of thermal stressed TN-LCDs showed the same performances on none thermal stressed TN-LCDs. There was little change in TN cells. Also, while increasing thermal stress time, the transmittances of TN-LCDs on the rubbed PI surface were almost the same, But the thermal stability of TN cell was deteriorated.

  • PDF

지중 열교환 시스템을 위한 열-수리 파이프 요소의 개발 (Development of Thermal-Hydro Pipe Element for Ground Heat Exchange System)

  • 신호성;이승래
    • 한국지반공학회논문집
    • /
    • 제29권8호
    • /
    • pp.65-73
    • /
    • 2013
  • 지중 열교환 시스템은 지속적인 에너지 효율의 개선으로 공간 냉난방을 위한 친환경적 에너지 기술로 주목받고 있다. 지중에 매설된 파이프는 내부 유체 순환을 통하여 인접한 지반과 열적 상호작용으로부터 직접적인 열에너지 교환을 수행한다. 하지만, 파이프의 수치모델링에서 열-수리가 연관된 난류해석과 파이프의 긴 세장비에 의한 메쉬사이즈의 부적합성은 열교환 시스템의 적절한 수치해석을 어렵게 하고 있다. 본 논문에서는 파이프 내부 유체흐름에 대한 에너지 보존의 법칙을 적용하여 지배방정식을 유도하였으며, Galerkin수식화와 시간적분을 통하여 열-수리 연동일차원 파이프 요소를 개발하였다. 그리고 제안된 파이프 요소를 기 개발된 다공질 재료를 위한 열-수리-역학(Thermo-Hydro-Mechanical) 해석을 위한 유한요소 프로그램과 결합하였다. 개발된 요소를 이용한 수치해석 결과는 열응답 시험(Thermal Response Test) 결과로부터 주위지반의 유효 열전도도를 평가하기 위하여 사용하는 선형 열원 모델이 인접 파이프간의 열적상호작용과 파이프의 단부효과에 의하여 지반의 열전도도를 과다 평가하는 것으로 보여주었다. 따라서 열응답 시험 해석 결과에 대한 역해석을 적용하여 최적의 수렴성을 보여주는 변환행렬을 제시하였다.

압력파에 교란된 액적내부에서의 에너지 파동 및 반응 메커니즘 (Thermal Wave Transfer and Combustion Response of Droplet Perturbed by Acoustic Pressure)

  • 이길용;윤웅섭
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2005년도 제24회 춘계학술대회논문집
    • /
    • pp.183-188
    • /
    • 2005
  • 본 연구에서는 기상 압력파동에 구속된 액적 내부의 에너지 파동과 연소응답의 상관관계를 고찰하였다. SRK 상태방정식과 Flash 계산법에 기초한 1차원 액적 기화모델로 기상과 액상의 2상 시스템에 대한 수치해석을 수행하였다. n-Pentane 액적과 기체 질소를 대상으로 기상압력과 압력파동 구동주파수에 따른 에너지 파동의 전파특성을 분석하였다. 액적 내부 에너지 파동의 주파수가 낮을수록 액적 내부로의 에너지 전파가 용이하였으며 결과적으로 연소응답의 크기를 감소시키는 요인이 되었다.

  • PDF

가압경수로 주증기관 파단시 증기발생기 2차측 과도 열수력 응답에 미치는 오리피스형 유량제한기의 영향 (EFFECTS OF AN ORIFICE-TYPE FLOW RESTRICTOR ON THE TRANSIENT THERMAL-HYDRAULIC RESPONSE OF THE SECONDARY SIDE OF A PWR STEAM GENERATOR TO A MAIN STEAM LINE BREAK)

  • 조종철;민복기
    • 한국전산유체공학회지
    • /
    • 제20권3호
    • /
    • pp.87-93
    • /
    • 2015
  • In this study, a numerical analysis was performed to simulate the thermal-hydraulic response of the secondary side of a steam generator(SG) model equipped with an orifice-type SG outlet flow restrictor to a main steam line break(MSLB) at a pressurized water reactor(PWR) plant. The SG analysis model includes the SG upper steam space and the part of the main steam pipe between the SG outlet and the broken pipe end. By comparing the numerical calculation results for the present SG model to those obtained for a simple SG model having no flow restrictor, the effects of the flow restrictor on the thermal-hydraulic response of SG to the MSLB were investigated.

탄성내열재 배합 환경에 따른 내열 성능 변화에 관한 연구 (A Study on the Thermal Protection Performance of Elastomeric Insulators in Different Mixing Environments)

  • 김남조;서상규;강윤구;고청아
    • 한국추진공학회지
    • /
    • 제23권1호
    • /
    • pp.108-115
    • /
    • 2019
  • 고온 고압의 연소가스로부터 구조물을 보호하는 탄성내열재는 재료 조성 및 열환경 조건에 따라 열반응에 차이를 보인다. 본 논문에서는 탄성내열재의 배합 환경 변화에 따른 열반응 특성을 비교하였다. 탄성내열재의 내열 성능 시험은 내열고무성능평가장치(TPREM)를 이용하였으며, 연소실 압력 1,000 psig에서 연소가스속도를 각각 20 m/s과 100 m/s로 시험하였다. 연소실 압력-시간 선도, 재료 내부 온도-시간 선도, 탄성내열재 시편의 잔류 두께 및 열파괴두께를 획득하였다. 배합 환경에 따른 탄성내열재의 내열 성능은 유사하였다.

지하수 부존지역에서의 토질 및 암석 시료와 현장 열응답시험의 열전도도 비교 (Thermal Conductivity from an in-situ Thermal Response Test Compared with Soil and Rock Specimens under Groundwater-bearing Conditions)

  • 김진성;송성호;정교철
    • 지질공학
    • /
    • 제23권4호
    • /
    • pp.389-398
    • /
    • 2013
  • 국내에서 열물성에 관한 연구는 지역별, 암종별 열물성 파악을 위주로 진행되었으나, 지열냉난방시스템 설계 시에 실시하는 TRT (thermal response test)의 열전도도와 차이가 크게 나타남에 따라 본 연구에서는 지하수 부존량이 풍부한 지역에서 시료를 통한 열전도도와 TRT를 통한 열전도도를 비교하였다. 토양 시료의 열전도도는 1.32 W/m-K, 암석 시료의 열전도도는 2.88 W/m-K로 나타났으며, TRT로 측정된 열전도도는 3.13 W/m-K로 나타나 암석 시료보다 약 10% 정도 높게 나타났다. 연구지역은 지하수가 풍부하고 0.01의 수리경사를 가지고 있어 이 차이는 지하수 흐름에 의한 영향이라고 판단된다. 라인소스(line source) 이론에 따르면 TRT는 지반의 순수한 열전도도를 산정하는 것이 목적이므로, 국내 SCW (standing column well)형의 TRT는 라인소스 이론에 적합하지 않으며 지열냉난방시스템 설계 시에는 시료를 통한 열전도도값을 사용하는 것이 타당하다고 판단된다.

대류난방공간에서 온열쾌적조건의 분포상태 분석에 관한 연구 (Analysis of Thermal Comfort Factor′s Distribution in Convective Heating Space)

  • 공성훈
    • 한국주거학회논문집
    • /
    • 제6권1호
    • /
    • pp.31-37
    • /
    • 1995
  • The purpose of this study is to analyse the distribution of thermal sensation response and thermal environment condition in convective heating space. The contents of this study are as follows: 1)the spatial distributions of thermal conditions are measured 2)the thermal sensation vote of residents is taken in order to investigate the relation between thermal condition and human thermal sensation in sedentary condition 3)to analyse the distribution of subject's thermal sensation vote and thermal environment condition by two methods-regression method and graph method.

  • PDF

지중열전달특성 평가에 관한 해석 및 실험적 방법에 관한 연구 - 지중 열물성치 및 보어 홀 열 저항 평가 - (Study on Analytical and Empirical Methods for Assessing Geo-Heat Transfer Characteristics)

  • 박준언;백남춘
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.427-432
    • /
    • 2005
  • This study treats the advantage of in situ line source method measuring the heat transfer capacity of a borehole, using mobile equipment, to determine the thermal properties of the entire borehole system such as thermal conductivity, diffusiveity. volumetric heat capacity, and borehole thermal resistance. The results from the response test include not only the thermal properties of the ground and the borehole, but also conditions that are difficult to estimate, e,g. natural convection in the boreholes, asymmetry in the construction, etc. In this study, 1) theoretical in situ methods for assessing working fluid temperature variation in V-type PE tube have been introduced, and 2) TRTE(Thermal Response Test Equipment) has been built based on these kinds of theoretical in situ methods. Basically TRTE consists of a pump, a heater and temperature sensors for measuring the inlet and outlet temperatures of the borehole. In order to make equipment easily transportable it is set up on a small trailer. Since the response test takes above two days to execute, the test was fully automatic in recording measured data using Labview DAS(Data acquisition system) program. The test was demonstrated in the course of intensive research in this field through the one site at Ulsan city in Korea. From this kind of thermal properties test of borehole systems in situ, the design of the borehole system can be optimized regarding the total geological, hydro-geological and technical conditions at the location.

  • PDF