• Title/Summary/Keyword: thermal power

Search Result 4,996, Processing Time 0.033 seconds

Low Temperature Thermal Oxidation using ECR Oxygen Plasma (ECR 산소 플라즈마를 이용한 저온 열산화)

  • 이정열;강석원;이진우;한철희;김충기
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.68-77
    • /
    • 1995
  • Characteristics of electron cyclotron resonance (ECR) plasma thermal oxide grown at low-temperature have been investigated. The effects of several process parameters such as substrate temperature, microwave power, gas flow rate, and process pressure on the growth rate of the oxide have been also investigated. It was found that the plasma density, reactive ion species, is strongly related to the growth rate of ECR plasma oxied. It was also found that the plasma density increases with microwave power while it decreases with decreasing O2 flow rate. The oxidation time dependence of the oxide thichness showed parabolic characteristics. Considering ECR plasma thermal oxidation at low-temperature, the linear as well as parabolic rate constants calculated from fitting data by using the Deal-Grove model was very large in comparison with conventional thermal oxidation. The ECR plasma oxide grown on (100) crystalline-Si wafer exhibited good electrical characteristics which are comparable to those of thermal oxide: fixed oxide charge(N$_{ff}$)= 7${\times}10^{10}cm^{-2}$, interface state density(N$_{it}$)=4${\times}10^[10}cm^{-2}eV^{-1}$, and breakdown field > 8MV/cm.

  • PDF

Thermal Expansion Measurement of Turbine and Main Steam Piping by Using Strain Gages in Power Plants (스트레인게이지를 활용한 발전소 터빈 및 주증기 배관의 열팽창 측정)

  • Na, Sang-Soo;Chung, Jae-Won;Bong, Suk-Kun;Jun, Dong-Ki;Kim, Yun-Suk
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.886-891
    • /
    • 2000
  • One of the domestic co-generation plants have undergone excessive vibration problems of turbine attributed to external force for years. The root cause of turbine vibration may be shan alignment problem which sometimes is changed by thermal expansion and external farce, even if turbine technicians perfectly performed it. To evaluate the alignment condition from plant start-up to full load, a strain measurement of turbine and main steam piping subjected to thermal loading is monitored by using strain gages. The strain gages are bonded on both bearing housing adjusting bolts and pipe stoppers which. installed in the x-direction of left-side main steam piping near the turbine inlet in order to monitor closely the effect of turbine under thermal deformation of turbine casing and main steam piping during plant full load. Also in situ load of constant support hangers in main steam piping system is measured by strain gages and its results are used to rebalance the hanger rod load. Consequently, the experimental stress analysis by using strain gages turns out to be very useful tool to diagnose the trouble and failures of not only to stationary components but to rotating machinery in power plants.

  • PDF

Thermal Characteristic Analysis of Induction Motors for Machine Tool Spindle for Motion Error Prediction (운동오차 예측을 위한 공작기계 스핀들용 유도전동기의 발열량 해석)

  • Seong, Ki-Hyun;Cho, Han-Wook;Hwang, Jooho;Shim, Jongyoub
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.2
    • /
    • pp.141-147
    • /
    • 2015
  • This paper deals with thermal characteristic analysis of induction motors for machine tool spindle for motion error prediction. Firstly, the inverse design of general induction motors for machine tool spindle has been performed by design principles. Characteristics considering VVVF inverter of induction motors were analyzed. Secondary, power loss and thermal characteristics of induction motors analyzed by equivalent thermal resistance model from Motor-CAD S/W. To develop a second-order fitted power-loss distribution model for the constant-torque operating range of the induction motor, we employed the design of experiment and response surface methodology techniques. Finally, the analysis results were experimentally verified, and the validity of the proposed analysis method was confirmed.

A Thermodynamic Analysis on the Performance with turning Diesel Cycle into Diesel-Atkinson Cycle (디젤기관의 아트킨슨 사이클화에 따른 제반성능의 열역학적 해석)

  • 노기철;정양주;이종태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.1-11
    • /
    • 2004
  • In order to recognize thermal efficiency and power improvement in case that diesel cycle is turned into diesel-atkinson cycle, the fuel-air diesel-atkinson cycle considered gas exchange process is analyzed non-dimensionally and thermodynamically. As a result, in case of diesel-atkinson cycle, as expansion ratio is increased, thermal efficiency and mean effective pressure is increased and it has maximum value at Rec=1. When diesel cycle is turned into diesel-atkinson cycle by late intake valve closing timing, thermal efficiency and power is decreased because of the decline of effective compression ratio and intake airflow, but it could be compensated by increase of compression ratio or super-charged. In case compression ratio is compensated, Rec appears 1 around 100$^{\circ}$ ABDC, and it is expected that thermal efficiency is enhanced by 14.3% compared with conventional diesel cycle. In case compression ratio and intake airflow are compensated simultaneously, super-charged pressure is demanded 2.06bar at Rec=1 and it is more efficient when only compression ratio is compensated in the view point of thermal efficiency.

A Study on Thermal Performance of an Impinging Cooling Module for High Power LEDs (고출력 LED에 적용한 분사냉각모듈의 열성능에 관한 연구)

  • Lee, Dong Myung;Park, Sang Hee;Kim, Dongjoo;Kim, Kyoungjin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.13-19
    • /
    • 2012
  • Thermal performance of an impinging cooling module for 150 W class high power LEDs have been investigated numerically and experimentally. Parametric studies were performed to compare the effect of several design parameters such as nozzle number, nozzle spacing, coolant flow rate, and impinging distance. The experiments were also carried out in order to validate the numerical results and the comparison between the experimental and numerical results showed good agreement. It is found that the overall thermal resistance of impinging cooling module strongly depends on the nozzle number, nozzle spacing, flow rate, and impinging distance. This results showed the optimized operating condition when number of nozzles is 25, nozzles spacing is 4mm, flow rate is 2.70 lpm, distance between nozzles and impinging surface is 2 mm.

Performance Evaluation of Heat Sink for Cooling of LED Projector (LED 프로젝터 방열용 히트싱크의 성능평가)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Jeon, Dong-Soon;Kim, Seon-Chang;Son, Kwang-Eun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1167-1171
    • /
    • 2008
  • The flow and thermal performance of the skiving and louver fin type heat sinks for the cooling system of the small LED projector were experimentally evaluated. A small fan tester based on AMCA standards was used to control and measure the air flow rate into the heat sink. Three heat blocks were used to simulate the heat and light sources(red, green and blue) of the small LED projector. We measured the pressure drop, temperatures and input power at the specific air flow rate and discussed those results. As a result, it is found that the louver fin type heat sink has higher pressure drop and lower thermal resistance than the skiving type. From the comparison of the temperature of the heat block between skiving and louver fin type, the louver fin type heat sink was found to be more suitable for cooling the high power heat source than skiving type. The thermal performance of the fan-sink(louver fin type) system was discussed with the picture taken by a thermal video.

  • PDF

The Unsteady 2-D Numerical Analysis in a Horizontal Pipe with Thermal Stratification Phenomena (열성층현상이 존재하는 수평배관내에서의 비정상 2차원 수치해석)

  • Youm, Hag-Ki;Park, Man-Heung;Kim, Sang-Nung
    • Nuclear Engineering and Technology
    • /
    • v.28 no.1
    • /
    • pp.27-35
    • /
    • 1996
  • In this paper, an unsteady analytical model for the thermal stratification in the pressurizer surge line of PWR plant has been proposed to investigate the temperature profile, flow characteristics, and thermal stress in the pipe. In this model, the interface level, between hot and cold fluid, is assumed to be a function of time while the other models had developed for time independent or steady state. The dimensionless governing equations are solved by using a SIMPLE (Semi-Implicit Method for Pressure Linked Equations) algorithm. The analysis result for an example shows that the maximum dimensionless temperature difference is about 0.78 between hot and cold sections of pipe wall and the maximum thermal stress by thermal stratification is calculated about 276 MPa at the dimensionless time 27.0 under given conditions.

  • PDF

Experimental Study on the Thermal Effect of BIPV Modules Depending on the Ventilation Type of PV Module Backside (후면 환기조건에 따른 건물외피용 태양광발전(BIPV) 모듈의 열적 영향에 관한 실험연구)

  • Yoon, Jong-Ho;Kim, Jae-Ung
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.81-89
    • /
    • 2006
  • Building integrated photovoltaic (BIPV) system operates as a multi-functional building construction material. They not only produce electricity, but also are building integral components such as facade, roof, window and shading device. On the other hands lots of architectural considerations should be reflected such as Installation position, shading, temperature effect and so on. As PV modules function like building envelope in BIPV, combined thermal and PV performance should be simultaneously evaluated This study is on the combined thermal and PV performance evaluation of BIPV modules. The purpose of this study is to investigate a temperature effect of PV module depending on the ventilation type of PV module backside. Test cell experiment was performed to identify the thermal and power effect of PV modules. Measurement results on the correlation of temperature and power generation were obtained. Those results can be utilized for the development of optimal BIPV installation details in the very early design stage.

State of the Art and Research Trends on Electrode Materials of Thermal Batteries (열전지 기술 현황과 전극재료 개발 동향)

  • Kang, Seung-Ho;Park, Byung-Jun;Im, Chae-Nam;Cho, Sung-Baek;Cheong, Hae-Won;Yi, Junsin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.765-770
    • /
    • 2015
  • Thermal batteries are heat-activated primary reserve power sources that use inorganic salt as electrolytes and specially designed to meet extremely long or environmentally severe storage requirements. They are primarily used to deliver high power for relatively short periods in such applications as fuzes, missiles, ordnance and other military applications. In this paper, we describe a general overview and research trends on electrode materials for thermal batteries.

Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera (Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.