• Title/Summary/Keyword: thermal power

Search Result 4,970, Processing Time 0.035 seconds

Study on the Rankine Cycle using Ammonia-Water Mixture as Working Fluid for Use of Low-Temperature Waste Heat (저온폐열 활용을 위한 암모니아-물 혼합물을 작업유체로 하는 랭킨사이클에 관한 연구)

  • Kim, Kyoung-Hoon;Kim, Se-Woong;Ko, Hyung-Jong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.6
    • /
    • pp.570-579
    • /
    • 2010
  • Since the temperature of waste heat source is relatively low, it is difficult to maintain high level of efficiency in power generation when the waste heat recovery is employed in the system. In an effort to improve the thermal efficiency and power output, use of ammonia-water mixture as a working fluid in the power cycle becomes a viable option. In this work, the performance of ammonia-water mixture based Rankine cycle is thoroughly investigated in order to maximize the power generation from the low temperature waste heat. In analyzing the power cycle, several key system parameters such as mass fraction of ammonia in the mixture and turbine inlet pressure are studied to examine their effects on the system performance. The results of the cycle analysis find a substantial increase both in power output and thermal efficiency if the fraction of ammonia increases in the working fluid.

Study on the Multi-measuring Method for Evaluation of Internal Leak of Power Plant Valve (발전용 밸브누설 평가를 위한 다중계측 연구)

  • Lee, S.G.;Park, S.K.;Park, J.H.;Kim, K.H.;Kim, Y.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.35-40
    • /
    • 2007
  • Leak would happen because of the damage of high temperature and high-pressure valve in nuclear power plant. condition based prevention maintenance is essential by using the suitable method based on local condition. Energy loss prevention can prevent from an accurate test, Local actually and ability. The methods of test for high energy fluid leak at present are analysis of ${\Delta}T$, AE(Acoustic Emission) analysis, and thermal image. The result for test of secondary system in nuclear power plant Unit reveals that the AE occurred clearly in leakage situation, but thermal image didn't occur. It is identified that leak is occurred when the orifice located front and back of valve operates. It shows that making a impatient judgment by using the single method if it is leakage is containing uncertainty. So we think that using the Multi-Measuring method is more sound judgment than single-measuring method.

  • PDF

Power Cable Ampacity and Influential Factors Analysis under Operation

  • Tong, Qiang;Qi, Jianping;Wang, Yanling;Liang, Likai;Meng, Xiangxing;Zhang, Qiang
    • Journal of Information Processing Systems
    • /
    • v.14 no.5
    • /
    • pp.1136-1149
    • /
    • 2018
  • With the increasing of urban electricity demand, making the most use of the power cable carrying capacity has become an important task in power grid system. Contrary to the rated ampacity obtained under extremely conservative conditions, this paper presents the various steady value of cable ampacity by using the changing surrounding parameters under operation, which is based on cable ampacity calculation equation under the IEC-60287 standard. To some degree, the cable ampacity analysis of actual surroundings improves the transmission capacity of cables. This paper reveals the factors that influence cable ampacity such as insulating layer thickness, allowable long-term conductor temperature, the ambient temperature, soil thermal resistance coefficient, and so on, then gives the class of the influence of these parameters on the ampacity, which plays a great role in accurately calculating the real-time ampacity and improving the utilization rate of cable in the complex external environment condition. Furthermore, the transient thermal rating of the cable is analyzed in this paper, and temperature variation of the conductor under different overload conditions is discussed, which provides effective information for the operation and control of the system.

Phytoplankton Community in Adjacent Waters of Ulchin Nuclear Power Plant

  • Choi, Hyu Chang;Kang, Yeon Shik;Jeon, In Sung
    • Korean Journal of Environmental Biology
    • /
    • v.22 no.3
    • /
    • pp.426-437
    • /
    • 2004
  • To understand the phytoplankton community in adjacent waters of Ulchin nuclear power plant (UNPP), abundance and the size fractionated $chl-\alpha$ concentrations were evaluated through seasonal interval sampling from April 2003 to February 2004. A total of 211 different phytoplankton species was observed and mean abundance of phytoplankton in each study period ranged from 244,286 to 1,221,779 cells $L^{-1}$. The contributions of microplankton $(>20\mu{m})$ to total phytoplankton abundance ranged from 42.5 to 83.6% (average 66.1%) and those of nanoplankton $(>20\mu{m})$ ranged from 16.4 to 57.5% (average 33.9%). Total chl-$\alpha$ concentrations of phytoplankton ranged from 0.52 to $2.26\mu{g}\;L^{-1}$. The contribution of chl-$\alpha$ concentrations of microplankton was higher than that of nano- and picoplankton through the study period with exception of July 2008. The results of abundances and $chl-\alpha$ concentrations suggest that microplankton has an important role in adjacent waters of UNPP. The diminution of abundances and $chl-\alpha$ concentrations of phytoplankton was observed after passage through the cooling water system, but it was gradually recovered by mixing with the ambient waters. Our results suggested that the influence of thermal discharges on phytoplankton should be restricted within narrow limits around outlet area of thermal effluents.

Desulfurization Characteristics for Anthracite Coal Power Plant by Increasing Bituminous Coal Fuel (국내 무연탄 발전소 역청탄 사용시 탈황 특성 연구)

  • Kim, Jeong-You;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.4 no.4
    • /
    • pp.71-77
    • /
    • 2008
  • The sulfur oxides is one of important materials to come about air pollution at thermal plant consuming fossil fuel. The several flue gas desulfurization equipments are installed and operated to decrease sulfur oxides. The flue gas desulfurization of our thermal plant is designed for optimizing flue gas desulfurization technical development and research by Korea Electric Power Research Institute. We operate this desulfurization equipment. Now, our country imports nearly 97 percentage of the energy source and competes with the world for the energy because of the sudden rise of raw materials cost. The fuel cost decrease of power plants is the most important factor of the operation. The fuel used in the experiment is the domestic anthracite from Kangwon Taeback and the bituminous coal from Taldinsky Mine in Russia. This Study is experimental investigations of desulfurization characteristics for domestic anthracite power plant by increasing bituminous coal. We surveyed possible parameters and conducted the performance about desulfurization equipment in Yong Dong thermal power plant.

  • PDF

Thermal Discharge Effects on the Species Composition and Community Structure of Macrobenthos in Rocky Intertidal Zone Around the Taean Thermoelectric Power Plant, Korea (태안화력발전소 주변 암반조간대에 서식하는 대형저서동물의 종조성 및 군집구조에 미치는 온배수의 영향)

  • Jung, Yun-Hwan;Kim, Hyung June;Park, Heung-Sik
    • Ocean and Polar Research
    • /
    • v.40 no.2
    • /
    • pp.59-67
    • /
    • 2018
  • This study was conducted to understand the distribution and changes of macrobenthos on rocky intertidal areas around Taean thermoelectric power plant, Also, the purpose of this study was to produce a base-line data on the changes in water temperature due to the operation of the power plant and to understand its thermal impact on the macrobenthic community on intertidal rocky bottoms. A field survey was seasonally conducted at 3 rocky intertidal sites around the Taean thermal power plant. There was no seasonal difference in the community parameters such as number of species, mean density, biomass and species diversity during the study period. The major dominant species were Chthamalus challenger, Littorina brevicula, Crassostrea gigas. In comparison with previous study, thermal discharge in the study area did not significantly affect the distribution of dominant species. The structure of the macrobenthic community revealed that there were showed 3 different faunal groups depending on the difference in the mean density of major dominant species. The result of SIMPER analyses to determine which species were the main contributors to the differences between each community, C. challenger, Lottia spp. And Mytilus galloprovincialis, etc., revealed that there was showed a significant difference between each group. The abundance of M. galloprovincialis, showed a significant difference between faunal groups.

A Standard Guide to Physical Oceanographic Survey of the Effect of Thermal Discharge from a Nuclear Power Plant (원자력발전소 온배수 영향 해양물리분야 조사의 표준지침)

  • Lee, Jae-Hak;Ro, Young-Jae;Cho, Yang-Ki
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.12 no.1
    • /
    • pp.43-49
    • /
    • 2007
  • The methods of physical oceanographic surveys to examine the effect of thermal discharge from nuclear power plants in Korea have been reviewed and a standard guide to the survey is proposed. It is desirable that in situ observation and numerical thermal diffusion modeling are conducted simultaneously to describe the variation in temperature distribution affected by thermal discharge from a power plant because any observation or numerical modeling alone has limits to do so quantitatively. It is suggested that the field observation must be based on the concept of heat budget modeling considering all artificial and natural heat sources/sinks around the power plant. Any results from numerical modeling must reach to a certain statistical significance level to use for a standard temperature distribution. In addition, the development of standard numerical codes is proposed to improve the problems shown in the past numerical circulation and diffusion modelling.

Effect of CNTs on Electrical Properties and Thermal Expansion of Semi-conductive Compounds for EHV Power Cables

  • Jae-Gyu Han;Jae-Shik Lee;Dong-Hak Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.603-608
    • /
    • 2023
  • Carbon black with high purity and excellent conductivity is used as a conductive filler in the semiconductive compound for EHV (Extra High Voltage) power cables of 345 kV or higher. When carbon black and CNT (carbon nanotube) are applied together as a conductive filler of a semiconductive compound, stable electrical properties of the semiconductive compound can be maintained even though the amount of conductive filler is significantly reduced. In EHV power cables, since the semi-conductive layer is close to the conductor, stable electrical characteristics are required even under high-temperature conditions caused by heat generated from the conductor. In this study, the theoretical principle that a semiconductive compound applied with carbon black and CNT can maintain excellent electrical properties even under high-temperature conditions was studied. Basically, the conductive fillers dispersed in the matrix form an electrical network. The base polymer and the matrix of the composite, expands by heat under high temperature conditions. Because of this, the electrical network connected by the conductive fillers is weakened. In particular, since the conductive filler has high thermal conductivity, the semiconductive compound causes more thermal expansion. Therefore, the effect of CNT as a conductive filler on the thermal conductivity, thermal expansion coefficient, and volume resistivity of the semiconductive compound was studied. From this result, thermal expansion and composition of the electrical network under high temperature conditions are explained.

Analysis of mill & burner control at thermal power plant (발전소 MBC(Mill & Burner Control) 로직 분석)

  • Shin, Man-Su;Kim, Byeng-Cheol;Choe, In-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1662_1663
    • /
    • 2009
  • There are generator/turbine/boiler control system in the thermal power plant. By the way, the manufacturers are different each other in many cases. Therefore there were many difficulties in interface and maintenance of power plant. So, we have been developing the integration of all control system in a single manufacturer. Mill & burner control is analyzed in this paper.

  • PDF

Design of a decentralized multilevel control for thermal power plant (발전플랜트의 다단계 분산제어기 설계)

  • 이은호;김석우;김영철
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1217-1220
    • /
    • 1996
  • For the purpose of the good tracking to variable load demands of the thermal power plant, a decentralized multilevel control(DMC) scheme is presented. It is applied to the drum type boiler-turbine system which is simplified from Boryung T/P #1,2 model[4]. A linearized model is decomposed into three subsystems by means of linear transformation. Then the DMC based on such subsystem is designed. Simulation using Matlab-Simulink shows that the proposed algorithm works very well to the large step change of power demand.

  • PDF