• Title/Summary/Keyword: thermal paper

Search Result 6,209, Processing Time 0.032 seconds

A Study on Wasteform Properties of Spent Salt Treated with Zeolite and SAP (염화염을 제올라이트와 SAP로 처리한 고화체의 특성연구)

  • Kim, Hwan-Young;Park, Hwan-Seo;Kang, Kweon-Ho;Ahn, Byung-Gil;Kim, In-Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.2
    • /
    • pp.99-105
    • /
    • 2010
  • This paper investigated the characteristics of wasteform containing a spent zeolite used as a separating agent of FPs for recycling LiCl waste which would be generated from pyrochemical process of spent PWR fuel. In this study, a conventional borosilicate and Ca-rich glass were used as a consolidating agent for spent zeolite and it's mixing ratio was changed in the range, $25{\sim}35wt%$. The leach rates of Cs and Sr had about $0.1{\sim}0.01g/m^2day$ and $0.001{\sim}0.0001g/m^2day$, respectively. The leach resistance of Cs increased with amount of SAP and it showed about 10 times higher in the Ca-rich glass wasteform than in the conventional borosilciate glass wasteform. The compressive strength of wasteform was affected with the amount of glass. Thermal expansion rate of containing 30wt% glass has relatively lower than others. Also, the melting temperature was little changed in given mixing ratio of glass.

Development of Tunnel-Environment Monitoring System and Its Installation III -Measurement in Solan Tunnel- (터널 환경 측정 시스템 개발 및 측정 III -솔안터널 측정결과 분석-)

  • Park, Won-Hee;Cho, Youngmin;Kwon, Tae-Soon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.637-644
    • /
    • 2016
  • This paper is a follow-up to previous papers entitled, "Development of Tunnel-Environment Monitoring System and Its Installation" I [1] and II [2]. The target tunnel of these studies is the Solan Tunnel, which is a loop-type, single-track, 16.7-km-long tunnel located in mountainous terrain and passing through the Baekdudaegan mountain range. It is an ordinary railway tunnel designed for both freight and passenger trains. We analyzed the environmental conditions of the tunnel using temperature and humidity data recorded over approximately one year. The data were recorded using the Tunnel Rough Environment Measuring System (TREMS), which measures environmental data in subway and high-speed train tunnels and is installed in three locations inside the tunnel. Previous studies analyzed environmental conditions inside tunnels located in or near a city, whereas the tunnel in this study is located in a mountainous area. The tunnel conditions were compared with those measured outside the tunnel for each month. Hourly changes during summer and winter periods were also analyzed, and the environmental conditions at different locations inside the tunnel were compared. The results are widely applicable in studies on the thermal environment and air quality of tunnels, as well as for computer analysis of tunnel airflow such as tunnel ventilation and fire simulations.

Optical System Design of Compact Head-Up Display(HUD) using Micro Display (마이크로 디스플레이를 이용한 소형 헤드업 디스플레이 광학계 설계)

  • Han, Dong-Jin;Kim, Hyun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.9
    • /
    • pp.6227-6235
    • /
    • 2015
  • The HUD has recently been downsized due to the development of micro display and LED technology as a see through information display device, gradually expands the application areas. In this paper, using a DLP micro display device designed a compact head-up display(HUD) optical system for biocular observation of the image exhibition area 5 inches. It was analyzed for each design element of the optical system in order to design a compacted HUD. DLP, projection optical system and concave image combiner were discussed the design approach and the characteristics. Through a connection structure analysis of each optical system, detailed design specifications were set up and designed the optical system in detail. Put a folded configuration in the form of a white diffuse reflector between the projection lens and concave image combiner was designed to be independent, respectively. Distance of the projected image is adjustable up to approximately 2m ~ infinity and observation distance is 1m. Resolution could be recognized by 1 ~ 2pixels in HD($1,280{\times}720pixels$) class, various characters and symbols could be read. In addition, color navigation map, daytime video camera and thermal imaging cameras can be displayed.

Effect of Fe on the High Temperature Oxidation of Ti-Al-Fe Alloys (Ti-Al-Fe계 합금의 고온산화거동에 미치는 Fe의 영향)

  • Yoon, Jang-Won;Hyun, Yong-Taek;Kim, Jeoung-Han;Yeom, Jong-Taek;Yoon, Seog-Young
    • Korean Journal of Materials Research
    • /
    • v.21 no.7
    • /
    • pp.357-363
    • /
    • 2011
  • In this paper, high temperature oxidation behavior of newly developed alloys, Ti-6Al-4Fe and Ti-6Al-1Fe, is examined. To understand the effect of Fe on the air oxidation behavior of the Ti-Al-Fe alloy system, thermal oxidation tests are carried out at $700^{\circ}C$ and $800^{\circ}C$ for 96 hours. Ti-6Al-4V alloy is also prepared and tested under the same conditions for comparison with the developed alloys. The oxidation resistance of the Ti-Al-Fe alloy system is superior to that of Ti-6Al-4V alloy. Ti-6Al-4V shows the worst oxidation resistance for all test conditions. This is not a result of the addition of Fe, but rather it is due to the elimination of V, which has deleterious effects on high temperature oxidation. The oxidation of the Ti-Al-Fe alloy system follows the parabolic rate law. At $700^{\circ}C$, Fe addition does not have a noticeable influence on the amount of weight gain of all specimens. However, at $800^{\circ}C$, Ti-6Al-4Fe alloy shows remarkable degradation compared to Ti-6Al-1Fe and Ti-6Al. It is discovered that the formation of $Al_2O_3$, a diffusion resistance layer, is remarkably hindered by a relative decrease of the ${\alpha}$ volume fraction. This is because Fe addition increases the volume fraction of ${\beta}$ phase within the Ti-6Al-xFe alloy system. Activities of Al, Ti, and Fe with respect to the formation of oxide layers are calculated and analyzed to explore the oxidation mechanism.

Geomechanical Stability of Underground Lined Rock Caverns (LRC) for Compressed Air Energy Storage (CAES) using Coupled Thermal-Hydraulic-Mechanical Analysis (열-수리-역학적 연계해석을 이용한 복공식 지하 압축공기에너지 저장공동의 역학적 안정성 평가)

  • Kim, Hyung-Mok;Rutqvist, Jonny;Ryu, Dong-Woo;Synn, Joong-Ho;Song, Won-Kyong
    • Tunnel and Underground Space
    • /
    • v.21 no.5
    • /
    • pp.394-405
    • /
    • 2011
  • In this paper, we applied coupled non-isothermal, multiphase fluid flow and geomechanical numerical modeling using TOUGH-FLAC coupled analysis to study the complex thermodynamic and geomechanical performance of underground lined rock caverns (LRC) for compressed air energy storage (CAES). Mechanical stress in concrete linings as well as pressure and temperature within a storage cavern were examined during initial and long-term operation of the storage cavern for CAES. Our geomechanical analysis showed that effective stresses could decrease due to air penetration pressure, and tangential tensile stress could develop in the linings as a result of the air pressure exerted on the inner surface of the lining, which would result in tensile fracturing. According to the simulation in which the tensile tangential stresses resulted in radial cracks, increment of linings' permeability and air leakage though the linings, tensile fracturing occurred at the top and at the side wall of the cavern, and the permeability could increase to $5.0{\times}10^{-13}m^2$ from initially prescribed $10{\times}10^{-20}m^2$. However, this air leakage was minor (about 0.02% of the daily air injection rate) and did not significantly impact the overall storage pressure that was kept constant thanks to sufficiently air tight surrounding rocks, which supports the validity of the concrete-lined underground caverns for CAES.

Design and Reliability Evaluation of 5-V output AC-DC Power Supply Module for Electronic Home Appliances (가전기기용 직류전원 모듈 설계 및 신뢰성 특성 해석)

  • Mo, Young-Sea;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.504-510
    • /
    • 2017
  • This paper presents an AC-DC power module design and evaluates its efficiency and reliability when used for electronics appliances. This power module consists of a PWM control IC, power MOSFETs, a transformer and several passive devices. The module was tested at an input voltage of 220V (RMS) (frequency 60 Hz). A test was conducted in order to evaluate the operation and power efficiency of the module, as well as the reliability of its protection functions, such as its over-current protection (OVP), overvoltage protection (OVP) and electromagnetic interference (EMI) properties. Especially, we evaluated the thermal shut-down protection (TSP) function in order to assure the operation of the module under high temperature conditions. The efficiency and reliability measurement results showed that at an output voltage of 5 V, the module had a ripple voltage of 200 mV, power efficiency of 73 % and maximum temperature of $80^{\circ}C$ and it had the ability to withstand a stimulus of high input voltage of 4.2 kV during 60 seconds.

Fabrication and Output Characteristics of an (18+1)×1 Polarization-maintaining Pump and Signal Combiner for a High-power Fiber Laser (고출력 광섬유 레이저용 (18+1)×1 편광유지 펌프 및 신호광 결합기 제작 및 출력 특성)

  • Lee, Sung Hun;Kim, Ki Hyuck;Yang, Hwan Seok;Cho, Seung Yong;Kim, Seon Ju;Park, Min Kyu;Lee, Jung Hwan
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.5
    • /
    • pp.187-192
    • /
    • 2019
  • In this paper a pump combiner, a key component of a high-power fiber laser, was fabricated, and its output characteristics measured using a high-power performance measuring instrument. The $(18+1){\times}1$ pump combiner consists of an optical-fiber bundle of one signal fiber and 18 pump fibers, an output optical fiber, and housing. The signal and output fibers were fabricated using polarization-maintaining optical fiber. By measuring the loss of signal light along the tapering length of the optical-fiber bundle, the tapering length was optimized to 18 mm. Signal-light insertion loss, pump-light transmittance, and polarization extinction ratio of the fabricated $(18+1){\times}1$ pump combiner were measured as 6.5%, 98.07%, and 18.0 dB respectively. The temperature distribution of the pump combiner, at a high power of 2 kW using 18 pump laser diodes, was measured and analyzed using a thermal-imaging camera.

Auto-Tracking Camera Gimbal for Power Line Inspection Drone and its Field Tests on 154 kV Transmission Lines (송전선로 자동추적 카메라 짐벌 및 154 kV 송전선로 현장시험)

  • Kim, Seok-Tae;Park, Joon-Young;Lee, Jae-Kyung;Ham, Ji-Wan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.3
    • /
    • pp.149-156
    • /
    • 2019
  • In the field of maintenance of power transmission lines, drones have been used for their patrol and inspection by KEPCO since 2017. This drone technology was originally developed by KEPCO Research Institute, and now workers from four regional offices of KEPCO have directly applied this technology to the drone patrol and inspection tasks. In the drone inspection system, a drone with an optical zooming camera and a thermal camera can fly automatically along the transmission lines by the ground control system developed by KEPCO Research Institute, but its camera gimbal has been remotely controlled by a field worker. Especially the drone patrol and inspection has been mainly applied for the transmission lines in the inaccessible areas such as regions with river-crossings, sea-crossings and mountains. There are often communication disruptions between the drone and its remote controller in such extreme fields of mountain areas with many barriers. This problem may cause the camera gimbal be out of control, even though the inspection drone flies along the flight path well. In addition, interference with the reception of real-time transmitted videos makes the field worker unable to operate it. To solve these problems, we have developed the auto-tracking camera gimbal system with deep learning method. The camera gimbal can track the transmission line automatically, even when the transmitted video on a remote controller is intermittently unavailable. To show the effectiveness of our camera gimbal system, its field test results will be presented in this paper.

Magnetoresistance Properties of Spin Valves Using MoN Underlayer (MoN 하지층을 이용한 스핀밸브의 자기저항 특성)

  • Kim, Ji-Won;Jo, Soon-Chul;Kim, Sang-Yoon;Ko, Hoon;Lee, Chang-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.5
    • /
    • pp.240-244
    • /
    • 2006
  • In this paper, magnetic properties and annealing behavior of spin valve structures using Mo(MoN) layers as underlayers were studied varying the thickness of the underlayers. The spin valve structure was consisted of Si substrate/$SiO_2(2,000{\AA})/Mo(MoN)(t{\AA})/NiFe(21\;{\AA})/CoFe(28\;{\AA})/Cu(22\;{\AA})/CoFe(18\;{\AA})/IrMn(65\;{\AA})/Ta(25\;{\AA})$. Also, MoN films were deposited on Si substrates and their thermal annealing behavior was analyzed. The resistivity of the MoN film increased as the $N_2$ gas flow rate was increased. After annealing at $600^{\circ}C$, XRD results did not show peaks of silicides. XPS results indicated MoN film deposited with 5 sccm of $N_2$ gas flow rate was more stable than the film deposited with 1 sccm of $N_2$ gas flow rate. The variations of MR ratio and magnetic exchange coupling fold were small for the spin valve structures using Mo(MoN) underlayers up to thickness of45 ${\AA}$. MR ratio of spin valves using MoN underlayers deposited with various $N_2$ gas flow rate was about 7.0% at RT and increased to about 7.5% after annealing at $220^{\circ}C$. Upon annealing at $300^{\circ}C$, the MR ratio decreased to about 3.5%. Variation of $N_2$ gas flow rate up to 5 sccm did not change the MR ratio and $H_{ex}$ appreciably.

Severe Accident Sequence Analysis - Part 1: Analysis of Postulated Core Meltdown Accident Initiated by Small Break LOCA in Kori-1 PWR Dry Containment (고리 1호기 소형파단 냉각제 상실사고에 의해 개시된 가상 노심용융 사고 해석)

  • Jong In Lee;Seung Hyuk Lee;Jin Soo Kim;Byung Hun Lee
    • Nuclear Engineering and Technology
    • /
    • v.16 no.3
    • /
    • pp.141-154
    • /
    • 1984
  • An analysis is presented of key phenomena and scenario which imply some general trends for beyond design-basis-accident in Kori-1 PWR dry containment. The study covers a wide range of severe accident sequences initiated by small break LOCA. The MARCH computer code, with KAERI modifications was used in this analysis. The major emphasis of the paper are two folds, 1) the phenomenologic understanding of severe accident and 2) a study of H2 combustion and debris/ water interactions in a specific small break LOCA for Kori-1 plant. The sensitivity studies for the specific plant data and thermal interaction modelings used in the SASA were performed. The results show that if hydrogen burning does occur at low concentration, the resulting peak pressure does not exceed the design value, while the lower concentration assumption results in repeated burning due to the continuing H$_2$ generation. For debris/water interaction, the particle size has no effect on the magnitude of peak pressure for the amount of water assumed to be in the reactor cavity. But, the occurrence of peak pressure is considerably delayed in case of using the dryout correlation. The peak containment pressure predicted from the hydrogen combustion and steam pressure spite during full core meltdown scenario does not present a severe threat to the containment integrity.

  • PDF