• Title/Summary/Keyword: thermal paper

Search Result 6,194, Processing Time 0.035 seconds

Effects of thermal aging on variations in paper color (강제열화에 따른 종이의 색상변화)

  • Kim, Sun-Kyung;Choi, Eun-Yeon;Lee, Yong-Kyu;Cho, Byoung-Uk
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2011.04a
    • /
    • pp.235-241
    • /
    • 2011
  • Effects of thermal aging on color variations of various papers were evaluated. With thermal aging, most of papers showed a special trend in $a^*$-$b^*$ plane: $a^*$ (red-green) values of the samples were reduced at beginning and after a turning point it was increased while $b^*$ (blue-yellow) was kept increased (yellowing of paper). In case of filter paper which consists of chemical pulps, the changes in $a^*$ value was occurred late compared with other samples. In case of the copy paper with optical brightening agent, the turning point in $a^*$ was not observed while a constant increase in $b^*$ was observed. In case of color paper, no specific trends in $a^*$-$b^*$ were found.

  • PDF

A study on the thermal deformation characteristics of steel plates due to multi-line heating

  • Lee, Joo-Sung;Lee, Sang-Hoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.1
    • /
    • pp.48-59
    • /
    • 2018
  • This paper is mainly concerned with developing the formulae of predicting thermal deformation of steel plate due to multi-line heating. By investigating the results of line heating test and numerical analysis, reasonable heat flux model has been defined. Formulae of predicting the transverse shrinkage and the angular distortion as the dominant thermal deformation types in plate forming by line heating have been derived based on the results of line heating test and numerical analysis with varying plate thickness, heating speed and distance between torches. This paper illustrates how the derived formulae are used in investigating the effect of multi-line heating upon the thermal deformation and how they can be used in defining the limit distance with that there is no interacted effect between torches. This paper ends with describing the extension of the present study.

Study on the Thermal Fastness of Fluorescent Whitening Agents (제지용 형광증백제의 열 견뢰도에 대한 연구)

  • Kim, Chul-Hwan;Lee, Ji-Young;Kim, Beong-Ho;Choi, Jae-Sung;Lim, Gi-Baek;Kim, Da-Mi
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • Fluorescent whitening agents (FWAs) are used extensively in the paper industry to improve the optical properties. FWAs are neither photochemically nor thermally stable, and thereby the papers containing FWAs can be damaged by external heat. We observed that the CIE whiteness, ISO brightness and fluorescence index of the commercial papers decreased with the thermal treatment and thought that the thermal fastness of FWAs was the main factor affecting the thermal stability of the papers. Thus, the model papers treated with three types of FWAs were manufactured respectively and the thermal stability of FWAs was identified by determining ${\Delta}$ CIE whiteness and ${\Delta}$ fluorescence index.

Dynamic Thermal Rating of Overhead Transmission Lines Based on GRAPES Numerical Weather Forecast

  • Yan, Hongbo;Wang, Yanling;Zhou, Xiaofeng;Liang, Likai;Yin, Zhijun;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • v.15 no.4
    • /
    • pp.724-736
    • /
    • 2019
  • Dynamic thermal rating technology can effectively improve the thermal load capacity of transmission lines. However, its availability is limited by the quantity and high cost of the hardware facilities. This paper proposes a new dynamic thermal rating technology based on global/regional assimilation and prediction system (GRAPES) and geographic information system (GIS). The paper will also explore the method of obtaining any point meteorological data along the transmission line by using GRAPES and GIS, and provide the strategy of extracting and decoding meteorological data. In this paper, the accuracy of numerical weather prediction was verified from the perspective of time and space. Also, the 750-kV transmission line in Shaanxi Province is considered as an example to analyze. The results of the study indicate that dynamic thermal rating based on GRAPES and GIS can fully excavate the line power potential without additional cost on hardware, which saves a lot of investment.

Thermal Response Analysis of a Low Thermal Drift Three-axis Accelerometer for High Temperature Environments

  • Ishida Makoto;Lee Kyung Il;Takao Hidekuni;Sawada Kazuaki;Seo Hee Don
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.872-875
    • /
    • 2004
  • In this paper, thermal response analysis of a temperature controlled three-axis accelerometer for high temperature environments with integrated micro-heaters and temperature sensors is investigated with finite element method (FEM) program, ANSYS and infrared thermal measurement systems. And availability to application fields from a viewpoint about short thermal response time is discussed. In this paper, the time of three-axis accelerometer for high temperatures becoming $300^{\circ}C$ by integrated micro-heaters and temperature sensors to reduce thermal drift characteristics was analyzed as a thermal response time of this device. The simulated thermal response time (time until SOI piezoresistors actually becomes $300^{\circ}C$) of three-axis accelerometer for high temperatures with ANSYS is about 0.6s, and measured result with infrared temperature measurement systems is about 0.64s. Experimental results using infrared thermal measurement systems agreed well with these theoretical results.

  • PDF

Nonlinear thermal post-buckling analysis of graphene platelets reinforced metal foams plates with initial geometrical imperfection

  • Yin-Ping Li;Gui-Lin She;Lei-Lei Gan;Hai-Bo Liu
    • Steel and Composite Structures
    • /
    • v.46 no.5
    • /
    • pp.649-658
    • /
    • 2023
  • Although some scholars have studied the thermal post-buckling of graphene platelets strengthened metal foams (GPLRMFs) plates, they have not considered the influence of initial geometrical imperfection. Inspired by this fact, the present paper studies the thermal post-buckling characteristics of GPLRMFs plates with initial geometrical imperfection. Three kinds of graphene platelets (GPLs) distribution patterns including three patterns have been considered. The governing equations are derived according to the first-order plate theory and solved with the help of the Galerkin method. According to the comparison with published paper, the accuracy and correctness of the present research are verified. In the end, the effects of material properties and initial geometrical imperfection on the thermal post-buckling response of the GPLRMFs plates are examined. It can be found that the presence of initial geometrical imperfection reduces the thermal post-buckling strength. In addition, the present study indicates that GPL-A pattern is best way to improve thermal post-buckling strength for GPLRMFs plates, and the presence of foams can improve the thermal post-buckling strength of GPLRMFs plates, the Foam- II and Foam- I patterns have the lowest and highest thermal post-buckling strength. Our research can provide guidance for the thermal stability analysis of GPLRMFs plates.

Prediction of Thermal Conductivity of Spun Carbon/Phenolic Composites (스펀 탄소/페놀 복합재의 열전도도 예측)

  • 서부호;조영준;강태진;윤재륜
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.48-51
    • /
    • 2002
  • This paper predicted the thermal conductivity of spun carbon/phenolic composites by the thermal resistance method. This method uses the analogy between the diffusion of heat and electrical charge. To verify the theoretical predictions, the thermal conductivity of spun carbon/phenolic composites was examined experimentally. The reported thermal conductivities of graphite/epoxy composite of a eight harness satin laminate was used of the comparison with the prediction values of the model and it was noticed that a good agreement has been found.

  • PDF

Estimation of Design Thermal Loads on PSC Box Girder Bridges by Statistical Extrapolation of Analytical Data (해석 데이터의 통계적 방법을 통한 PSC 박스거더교의 설계 온도 하중 추정)

  • 황의승;임창균;이영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.497-500
    • /
    • 2000
  • This paper describes the procedures to estimate for the design thermal loads on prestressed concrete box girder bridges on th basis of the extreme analysis of the temperature data obtained from long-term thermal analyses. Long-term thermal analyses using the environmental data for three years were conducted, and the extreme distributions of th thermal loads are then determined by the tail-equivalence method, and the thermal loads corresponding to selected return period are calculated. Finally, the results are compared to the specifications suggested in a current design code for thermal loads.

  • PDF

A Study on the Treatment of Paper Mill Wastewater with the Addition of High Thermal Microbial Inoculants (고온성 종균제를 이용한 제지폐수 처리)

  • 이성호;임택준;조준형
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.2
    • /
    • pp.54-60
    • /
    • 2002
  • The Wastewater of toilet paper mill recycling recovered milk carton was used as a raw material for this study. According to the actual mill conditions, hydraulic retention time was adjusted to 12 hours and F/M (Food/Micro-organism) ratio was adjusted to 0.23. Temperature of aeration basin was varied from 2$0^{\circ}C$ to 5$0^{\circ}C$. The change of Micro-organisms and removal efficiency of pollutant were investigated at the varied temperature of basin. Aeration basin using high thermal microbial inoculants showed more removal efficiency of SS, COD than aeration basin using conventional microbial inoculants at high temperature. Floc consolidation of aeration basin using high thermal microbial inoculants added sludge was better than that of sludge from aeration basin using conventional microbial inoculants.

Chemical Characteristics of Transformer Insulations by the Thermal Aging (변압기 절연물의 열화에 따른 화화적 특성)

  • Kim, Jae-Hoon;Lee, Won-Young;Lee, Byung-Sung;Lee, Sei-Hyun;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1912-1914
    • /
    • 2005
  • The electrical, chemical and mechanical characteristics in transformer insulations are changed due to thermal stress. It is known that characteristics of transformer insulations is deteriorated such as decrease of dielectric strength, deterioration of dielectric constant and tensile strength of paper as transformer oil and paper are aged by thermal stress. Furthermore, chemical characteristics of them are deteriorated as like increment of moisture contents and dissolved by-products in oil, etc. In this paper we have been investigated chemical characteristics of transformer by accelerated thermal aging. For this working we have made experimental test cell and aged at a temperature up to $140^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. For analysis we used Karl-Fisher titration method and high performance liquid chromatography (HPLC).

  • PDF