• 제목/요약/키워드: thermal modeling

검색결과 974건 처리시간 0.041초

환경영향평가와 사후환경조사의 비교에 관한 연구 - 태안화력발전소 사례분석 - (The Study on the Improvement of Environmental Assessment Method through Analysis of Environmental Investigation Results of Taean Thermal Power Plant)

  • 전상기;이성철
    • 환경영향평가
    • /
    • 제9권1호
    • /
    • pp.61-74
    • /
    • 2000
  • This study compares the results of environmental impact assessment with the results of post-environmental investigation, using the case of Taean thermal power plant construction. The atmospheric and water qualities were not greatly changed before and after the construction of the power plant. However, the site of the highest concentration predicted by the atmospheric quality modeling in environmental impact assessment was different from that after operation of 4 power plants. There was also a difference in the diffusion range of thermal discharge water between the measured result(1km) and the predicted value(1.5km) with the model. Thus, environmental impact evaluation should be based on long-term (more than a year) environmental monitoring data. For the modeling of atmospheric quality and numerical thermal discharge water diffusion, appropriate models for each plant should be selected and the numerical modeling should be accompanied by computer simulation, wind tunnel test, etc. Moreover, environmental evaluation should focus more on the degree of impact on surroundings than the prediction of changes in surroundings caused by operation of plants.

  • PDF

실측과 컴퓨터 모델링을 통한 미기후 요소 및 인간 열환경지수의 차이 비교 분석 (Comparison of Differences on Microclimatic Factors and Human Thermal Sensation between in situ Measurement and Computer Modeling)

  • 박수국;공학양;강훈
    • Ecology and Resilient Infrastructure
    • /
    • 제7권1호
    • /
    • pp.43-52
    • /
    • 2020
  • 본 연구는 컴퓨터 모델링의 결과를 실측자료 보정없이 이용하였을 때의 문제점을 조사하기 위해, 작은 도시공원을 대상으로 실측자료와 컴퓨터 모델링 결과를 비교 분석하여 보았다. 컴퓨터 모델링 결과는 실측자료에 비해 미기후 요소인 기온과 풍속에서는 과소예측을 보였으며, 상대습도와 평균복사온도에서는 과대예측을 하는 것으로 나타났다. 그 차이는 인간 열환경지수인 PMV와 UTCI에서 최대 2.3 PMV와 4℃ UTCI의 차이를 보였다. 그러므로, 인간 열환경지수 (열쾌적성) 연구에서 컴퓨터 모델링을 이용할 때는 반드시 실측자료를 이용한 결과보정 과정을 거쳐 도시와 조경계획 및 디자인에 적용되어야 할 것이다.

열상장비의 포화 현상에 대한 시스템 모델링 (System-Level Saturation Modeling of Thermal Imager)

  • 한승오;박승만
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.698-702
    • /
    • 2016
  • Thermal imager is now regarded as one of the key observation devices for ISR activities and getting important more and more. As other detectors, however, the thermal detectors also have maximum input and therefore they will be saturated if the input IR energy exceeds the allowed range. The saturation in the thermal detector makes it impossible to distinguish the target from background, as a result, the thermal imager does not perform its own mission anymore. In order to get an insight related with the image saturation, this paper develops a saturation model for a thermal imaging system, not a thermal detector. The proposed modeling starts from analyzing the specification of a thermal imager. Coupled with the characteristic parameters of the object, the saturation model can be used to predict the distance on which the detector is saturated. The proposed saturation model prove its validity by applying it for the case of observing a flash-bang.

대단위발전소의 대기오염물질 확산에 관한 모델링 및 평가에 관한 연구 (Modeling and Evaluation on the Dispersion of Air Pollutants in the Large Scale Thermal Power Plant)

  • 전상기;이성철
    • 환경영향평가
    • /
    • 제6권2호
    • /
    • pp.81-92
    • /
    • 1997
  • This paper presents the results from the comparison analysis and evaluation between the air pollutant dispersion modeling results and the observation data in the area within a 10 km radius from the Boryong thermal power plants. The observation data used in this study were the air pollutant concentrations which had been continuously measured from 8 locations around the Boryong power plants by TMS(tele-monitoring system) for 3 months from September to November, 1996. The short-term and long-term predictions were carried out using ISC3 model and LPDM(Lagrangian Panicle Dispersion Model). The results of ISC3 modeling in a short-term showed highly as 0.7 in a correlation coefficient, but in a long-term showed just 0.54. On the other hand, LPDM showed 0.78 in a correlation coefficient for a long-term, but in a short-term showed highly value than the observation concentrations.

  • PDF

Unsteady heat exchange at the dry spent nuclear fuel storage

  • Alyokhina, Svitlana;Kostikov, Andrii
    • Nuclear Engineering and Technology
    • /
    • 제49권7호
    • /
    • pp.1457-1462
    • /
    • 2017
  • Unsteady thermal processes in storage containers with spent nuclear fuel were modeled. The daily fluctuations of outer ambient temperatures were taken into account. The modeling approach, which is based on the solving of conjugate and inverse heat transfer problems, was verified by comparison of measured and calculated temperatures in outer channels. The time delays in the reaching of maximal temperatures for each spent fuel assembly were calculated. Results of numerical investigations show that daily fluctuation of outer temperatures does not have a large influence on the maximal temperatures of stored spent fuel, so that fluctuation can be neglected and only daily average temperature should be considered for safety estimation using the "best estimation" approach.

Magnetic and Thermal Evaluation of a Magnetic Tunneling Junction Current Sensor Package

  • Rhod, Eduardo;Peter, Celso;Hasenkamp, Willyan;Grion, Agner
    • 마이크로전자및패키징학회지
    • /
    • 제23권4호
    • /
    • pp.49-55
    • /
    • 2016
  • Nowadays there are magnetic sensors in a wide variety of equipment such as computers, cars, airplanes, medical and industrial instruments. In many of these applications the magnetic sensors offer safe and non-invasive means of detection and are more reliable than other technologies. The electric current in a conductor generates a magnetic field detected by this type of sensor. This work aims to define a package dedicated to an electrical current sensor using a MTJ (Magnetic Tunnel Junction) as a sensing device. Four different proposals of packaging, three variations of the chip on board (CoB) package type and one variation of the thin small outline package (TSOP) were analyzed by COMSOL modeling software by simulating a brad range of current injection. The results obtained from the thermal and magnetic analysis has proven to be very important for package improvements, specially for heat dissipation performance.

다공성 모델링을 이용한 평행류 열교환기의 열.유동 해석 (Heat and Flow Analysis of a Parallel Flow Heat Exchanger Using Porous Modeling)

  • 정길완;이관수
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1784-1792
    • /
    • 2001
  • Numerical analysis on a parallel flow heat exchanger(PFHE) is performed using 2 dimensional turbulent porous modeling. This modeling can consider three-dimensional configuration of passage (flat tube with micro-channels), and the stability and accuracy of numerical results are improved. The geometrical parameters(e.g., the position of separators, inlet/outlet, and porosity of passages of a PFHE) are varied in order to examine the flow and thermal characteristics and flow distribution of the single phase multiple passages system. The flow non-uniformities along the paths of the PFHE are observed to evaluate the thermal performance of the heat exchanger. The location of inlet affects the heat transfer, and the location of outlet affects the pressure drop. The porosity with the optimum thermal performance is around 0.53.

임펄스 착자요크 시스템의 온도특성에 관한 연구 (Temperature Characteristics of Impulsed Magnetizing Fixture System)

  • 백수현;맹인재;김용;김필수;함중걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1098-1100
    • /
    • 1993
  • In this paper, We found the thermal characterstic of impulsed magnetizing fixture system through the SPICE modeling and investigated the applied possibility in application aspects. As the detailed thermal characteristic of magnetizing fixure can be obtained, the efficient design of the magnetizing fixture which produce desired magnet will be possible using our thermal modeling. The purpose of this work is to compute the temperature increasing for different magnetizing conditions. The method uses multi-lumped model with equivalent thermal resistance and thermal capacitance. The model ing and experimental results are in close agreement.

  • PDF

ICA based Thermal Source Extraction and Thermal Distortion Compensation for Machine Tools

  • Lee, Dong-Soo;Park, Jin-Young;Park, Doo-Hyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.91.2-91
    • /
    • 2002
  • $\textbullet$ Machine tools $\textbullet$ Thermal distortion compensation $\textbullet$ Independent component analysis $\textbullet$ Temperature variable reduction $\textbullet$ Thermal distortion modeling $\textbullet$ Hardware Implementation $\textbullet$ Experiments

  • PDF

수분 흡수가 단열재의 열전도계수에 미치는 영향에 관한 연구 (A Study on the Effects of Water Absorption on the Thermal Conductivity of Insulation Materials)

  • 유성연;김태호
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.119-125
    • /
    • 2013
  • IInsulation material is generally used for preventing heat loss from heat transport fluids, and water absorption severely reduces the insulation property. The purpose of this study is to evaluate the amount of water absorption supplied by the pouring method and spraying method, to investigate the effects of water absorption on the thermal conductivity of an insulation material, and modeling the relation between water absorption and thermal conductivity. E-glass, a kind of glass fiber, and HYPERLITE, mainly composed of pearlite, are selected, to compare hygroscopic and insulation properties. E-glass is found to have much higher water absorptivity, compared to HYPERLITE. The thermal conductivity of the water-absorbed E-glass is increased by more than 150%, compared to that of no absorption, while variation of the thermal conductivity of HYPERLITE with water absorption is insignificant. A three-stage model of water absorption for thermal conductivity is developed, and the modeling results are found to be in good agreement with the experimental data.