• Title/Summary/Keyword: thermal limit

Search Result 501, Processing Time 0.022 seconds

A Study on the Thermo-flow Analysis of ISG (Integrated Starter and Generator) Driving Inverter (ISG 구동용 인버터의 열유동 해석에 관한 연구)

  • Kim, Dae Geon;Kim, Sung Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.5
    • /
    • pp.145-150
    • /
    • 2013
  • Recently, many vehicles have applied electric parts for saving fuel consumption and reducing levels of environmental pollution. ISG (integrated starter & generator) is one of main electric parts and can improve fuel efficiency by using idle stop & go function and regenerative braking system. However, if ISG driving inverter works under the continuously high load condition, it will make the performance and durability of the inverter decreased with rising temperature. In this study, we carried out the analysis on the fluid flow and thermal characteristics of the inverter. As a result, we found the MOSFET of the air cooled inverter was increased up to $116^{\circ}C$ over the limit temperature. On the other hand, the liquid cooled type inverter's MOSFET was decreased by about $17^{\circ}C$ compared to that of the air cooled inverter. Therefore, we verified the feasibility of the liquid cooled type using the present cooling structure.

Transient Analysis of the CANDU-9 480/SEU Reactor (CANDU-9 480/ SEU 원자로의 과도변화해석)

  • J. C. Shin;Park, J. H.;K. N. Han;H. C. Suk
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.687-700
    • /
    • 1995
  • The thermal-hydraulic transient analysis of the proposed CANDU-9 plant was peformed. Several major transients ore analyzed if they meet the heat transport system design requirements. The proposed heat transport system configuration and the preliminary sizes of system equipment are justified by analysis in terms of the fuel integrity and the high system pressure limit during transients. The compliance with AECB R-77 requirements for CANDU-9 reactor was estimated. The analysis results showed that for each postulated accident the peak pressure values in the reactor headers are within the acceptance criteria given in ASME code requirements and the fuel overheating is prevented. One pump start-up during the reactor start-up operation was analyzed to investigate the How reversal through the fuel channel, which is specific in the proposed CANDU-9 plant.

  • PDF

Experimental Study on the Performance of an Air-Cooling System for Telecommunication Equipment (통신장비용 공냉형 냉각시스템의 성능 특성에 대한 실험적 연구)

  • Jeon, Jong-Ug;Choi, Jong-Min;Heo, Jae-Hyeok;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.323-328
    • /
    • 2005
  • The objective of this study is to analyze the cooling performance of an air- cooling system for telecommunication equipment. Temperature variation and capacity were measured in an actual unit for telecommunication equipment. In addition, the cooling performance was measured by installing a silicon rubber heater as a heat source in a cabinet. The standard thermal load for telecommunication equipment was approximately 293 W, and the maximum temperature of the heated surface was $64.5^{\circ}C$. The average and maximum temperatures of the heated surface were proportional to the inlet air temperature. When the heat load increased from 293 W to 400 W, the maximum temperature of the heated surface was higher than $64.5^{\circ}C$ even though the inlet air temperature decreased from 25 to $11^{\circ}C$.

  • PDF

ACCURACY AND EFFICIENCY OF A COUPLED NEUTRONICS AND THERMAL HYDRAULICS MODEL

  • Pope, Michael A.;Mousseau, Vincent A.
    • Nuclear Engineering and Technology
    • /
    • v.41 no.7
    • /
    • pp.885-892
    • /
    • 2009
  • This manuscript will discuss a numerical method where the six equations of two-phase flow, the solid heat conduction equations, and the two equations that describe neutron diffusion and precursor concentration are solved together in a tightly coupled, nonlinear fashion for a simplified model of a nuclear reactor core. This approach has two important advantages. The first advantage is a higher level of accuracy. Because the equations are solved together in a single nonlinear system, the solution is more accurate than the traditional "operator split" approach where the two-phase flow equations are solved first, the heat conduction is solved second and the neutron diffusion is solved third, limiting the temporal accuracy to $1^{st}$ order because the nonlinear coupling between the physics is handled explicitly. The second advantage of the method described in this manuscript is that the time step control in the fully implicit system can be based on the timescale of the solution rather than a stability-based time step restriction like the material Courant limit required of operator-split methods. In this work, a pilot code was used which employs this tightly coupled, fully implicit method to simulate a reactor core. Results are presented from a simulated control rod movement which show $2^{nd}$ order accuracy in time. Also described in this paper is a simulated rod ejection demonstrating how the fastest timescale of the problem can change between the state variables of neutronics, conduction and two-phase flow during the course of a transient.

Zinc Oxide Wire-Like Thin Films as Nitrogen Monoxide Gas Sensor

  • Hung, Nguyen Le;Kim, Hyojin;Kim, Dojin
    • Korean Journal of Materials Research
    • /
    • v.25 no.7
    • /
    • pp.358-363
    • /
    • 2015
  • We present an excellent detection for nitrogen monoxide (NO) gas using polycrystalline ZnO wire-like films synthesized via a simple method combined with sputtering of Zn metallic films and subsequent thermal oxidation of the sputtered Zn nanowire films in dry air. Structural and morphological characterization revealed that it would be possible to synthesize polycrystalline hexagonal wurtzite ZnO films of a wire-like nanostructure with widths of 100-150 nm and lengths of several microns by controlling the sputtering conditions. It was found from the gas sensing measurements that the ZnO wire-like thin film gas sensor showed a significantly high response, with a maximum value of 29.2 for 2 ppm NO at $200^{\circ}C$, as well as a reversible fast response to NO with a very low detection limit of 50 ppb. In addition, the ZnO wire-like thin film gas sensor also displayed an NO-selective sensing response for NO, $O_2$, $H_2$, $NH_3$, and CO gases. Our results illustrate that polycrystalline ZnO wire-like thin films are potential sensing materials for the fabrication of NO-sensitive high-performance gas sensors.

Modification of Reference Temperature Program in Reactor Regulating System

  • Yu, Sung-Sik;Lee, Byung-Jin;Kim, Se-Chang;Cheong, Jong-Sik;Kim, Ji-In;Doo, Jin-Yong
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.404-410
    • /
    • 1998
  • In Yonggwang nuclear units 3 and 4 currently under commercial operation, the cold leg temperature was very close to the technical specification limit of 298$^{\circ}C$ during initial startup testing, which was caused by the higher-than-expected reactor coolant system flow. Accordingly, the reference temperature (Tref) program needed to be revised to allow more flexibility for plant operations. In this study, the method of a specific test performed at Yonggwang nuclear unit 4 to revise the Tref program was described and the test results were discussed. In addition, the modified Tref program was evaluated on its potential impacts on system performance and safety. The methods of changing the Tref program and the associated pressurizer level setpoint program were also explained. Finally, for Ulchin nuclear unit 3 and 4 currently under initial startup testing, the effects of reactor coolant system flow rate on the coolant temperature were evaluated from the thermal hydraulic standpoint and an optimum Tref program was recommended.

  • PDF

A Study on The Pulsating Combustion of Premixed Gas in a Tube with a Honeycomb (다공성 물질에 의한 예혼합기의 맥동연소에 관한 연구)

  • 권영필;이동훈;현길학
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.3
    • /
    • pp.676-684
    • /
    • 1990
  • This study is on the pulsating combustion of premixed gas in a Rijke type combustor made of a honeycomb flame holder in a tube. Modelling for the onset condition of the oscillation is made by the ratio of the acoustic power generation based on the analysis of heat transfer to the power loss due to the thermoviscous dissipation and radiation. Experiment is performed for the characteristics of acoustic, thermal and combustion. It is shown that the theoretical modelling for the oscillation may be used as a limit condition. And the combustion analysis for the acoustic power generation is needed for better prediction of the onset condition. Experimental result shows that, by pulsation, the flame length is shortened and the flame temperature is decreased with increase in the heat transfer coefficient. The NO$_{x}$ concentration in the exhaust gas is significantly reduced by pulsation and the concentration of unburned hydrocarbon shows a little increase.e.

Behavior of the Residual Stress on the Surfaces of 12Cr Steels Generated by Flame Hardening Process (화염경화 표면처리 공정에 의한 12Cr 강의 잔류응력 거동)

  • 이민구;김광호;김경호;김흥회
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.4
    • /
    • pp.226-233
    • /
    • 2004
  • The residual stresses on the surfaces of low carbon 12Cr steels used as a nuclear steam turbine blade material have been studied by controlling the flame hardening surface treatments. The temperature cycles on the surfaces of 12Cr steel were controlled precisely as a function of both the surface temperature and cooling rate. The final residual stress state generated by flame hardening was dominated by two opposite competitive contributions; one is tensile stress due to phase transformation and the other is compressive stress due to thermal contraction on cooling. The optimum processing temperatures required for the desirable residual stress and hardness were in the range of $850^{\circ}C$ to $960^{\circ}C$ on the basis of the specification of GE power engineering. It was also observed that the high residual tensile stress generated by flame hardening induced the cracks on the surfaces, especially across the prior austenite grain boundaries, and the material failure virtually, which might limit practical use of the surface engineered parts by flame hardening.

The Effective Heating Control Method of the Radiant Floor Heating System (바닥복사 난방공간의 효율적인 난방제어방법)

  • Cho, S.H.;Tae, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.3
    • /
    • pp.317-329
    • /
    • 1996
  • By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.

  • PDF

Assessment of Probabilistic Total Transfer Capability Considering Uncertainty of Weather (불확실한 날씨 상태를 고려한 확률론적 방법의 총 송전용량 평가)

  • Park Jin-Wook;Kim Kyu-Ho;Shin Dong-Jun;Song Kyung-Bin;Kim Jin-O
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.1
    • /
    • pp.45-51
    • /
    • 2006
  • This paper proposes a method to evaluate the Total Transfer Capability (TTC) by considering uncertainty of weather conditions. TTC is limited not only by the violation of system thermal and voltage limits, but also restricted by transient stability limit. Impact of the contingency on the power system performance could not be addressed in a deterministic way because of the random nature of the system equipment outage and the increase of outage probability according to the weather conditions. For these reasons, probabilistic approach is necessary to realize evaluation of the TTC. This method uses a sequential Monte Carlo simulation (MCS). In sequential simulation, the chronological behavior of the system is simulated by sampling sequence of the system operating states based on the probability distribution of the component state duration. Therefore, MCS is used to accomplish the probabilistic calculation of the TTC with consideration of the weather conditions.