• Title/Summary/Keyword: thermal impact

Search Result 824, Processing Time 0.026 seconds

Observational Study of Thermal Characteristics by Distribution Ratio of Green Area at Urban in Summer Season (하절기 관측을 통한 도시의 지역별 공간녹지분포율에 따른 열환경 특성 연구)

  • Jung, Im-Soo;Choi, Dong-Ho;Lee, Bu-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.3
    • /
    • pp.8-16
    • /
    • 2011
  • The objective of this study is to analyze the characteristic of thermal environment in the summer season by conducting the field observation of temperature, relative humidity, and globe temperature in some parts of the city. Observation point was divided to a densely populated area, a residential area, a green area, a waterfront green area and a suburban district by the distribution ratio of green area. In this study, the correlation between maximum temperature and globe temperature, study on index for intensity of the tropical night and the temperature distribution characteristic of measurement points by the distribution ratio of green area were analyzed. The results of this study are as follows. (1) The difference between temperature and globe temperature by the distribution ratio of green area is confirmed. The difference of nighttime is more clearly that of daytime. (2) The average temperature and globe temperature of the densely populated area($29.2^{\circ}C$, $33.7^{\circ}C$) are higher than that of the waterfront green area($27.9^{\circ}C$, $32.0^{\circ}C$) by $1.3^{\circ}C$ and $1.7^{\circ}C$, respectively. (3) The number of tropical nights has different days of tropical nights by the distribution ratio of green area of 17days for the Daegu weather station, 14days for adensely populated area, 14days for a residential area, 6days for a green area, 2days for a waterfront green area, and 2days for a suburban district. (4) The results of the slope of trend line for the effects of the temperature on globe temperature change and the intercept for the size of the impact of radiant energy gained around by the analysis of the correlation between the maximum temperature and globe temperature can be utilized objective evaluation index of the each point's artificial effects.

Effect of Silane Coupling Agent on Physical Properties of Polypropylene (PP)/Kenaf Fiber (KF) Felt Composites (폴리프로필렌/케나프 섬유 펠트 복합체 물성에 대한 실란커플링제의 영향)

  • Ku, Sun Gyo;Kim, Yu Shin;Kim, Dong Won;Kim, Ki Sung;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.37-42
    • /
    • 2018
  • In order to increase the compatibility of polypropylene (PP) and kenaf fiber (KF) felt, PP/KF and PP/KF/polyurethane (PU) felt composites were prepared by treating KF with three kinds of silane coupling agents. The concentration of silane coupling agents was fixed at 1 wt%. The chemical reaction between KF and silane coupling agents was confirmed by the existence of Si-O-Si and Si-O-C functional group bands appeared on FT-IR and X-ray photoelectron spectra (XPS). Thermal properties of PP/KF composites were investigated by DSC and TGA, and the thermal stability of PP/KF composites with treated KF increased. Based on tensile, flexural and impact properties of PP/KF and PP/KF/PU composites, 1-2 wt% of (3-aminopropyl)triethoxysilane (APS) contents were the optimum formulation as a compatibilizer. The tensile and flexural strength of the felt composites treated with the silane coupling agents were improved. This is mainly due to the improvement in the compatibility between PP and KF, which was confirmed by SEM images of the fractured surfaces after tension tests.

Preparation and Properties of Flame Retardant Epoxy Resins Containing Phosphorous/Silicone Components (인/실리콘 함유 난연성 에폭시 수지의 제조 및 물성)

  • Kim, Chang-Heon;Ha, Do-Young;Lee, Young Hee;Lee, Dong-Jin;Kim, Han-Do
    • Clean Technology
    • /
    • v.23 no.4
    • /
    • pp.378-387
    • /
    • 2017
  • To obtain epoxy resin with permanently attached flame-retardant groups, phosphorus compound containing di-hydroxyl group [10-(2,5-dihydroxyphenyl)-9,10-dihydro-9-oxa-10-phospha phenanthrene-10-oxide, DOPO-HQ] and silicone compound containing di-hydroxyl group (polydimethylsiloxane, hydroxyl terminated, PDMS) were reacted with uncured epoxy prepolymer (diglycidyl ether of bisphenol A, DGEBA) and then cured using 4,4-diaminodiphenylmethane (DDM) as a crosslinking agent. The properties of the resulting epoxy materials were characterized using Fourier transform infrared (FTIR) spectrometer, differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), limiting oxygen index (LOI) test/vertical burning test (UL 94-V test), tensile properties test and impact test. This study examined the effect of phosphorus/silicone compound contents on the thermal/mechanical properties and flame retardancy of cured epoxy resins containing phosphorus and silicone compounds. It was found that the thermal/mechanical properties of epoxy resins containing phosphorus and silicone components were higher than those of simple epoxy resin. The flame-retardancy (LOI: 29.9 ~ 31.8% and UL 94-V: V-0) of all samples containing phosphorus compound and phosphrous compound/silicone compound was found to be passed the flame-retardant requirements (LOI: > 30%, UL 94-V: V-0) of LOI and vertical burning tests. However, the flame-retardancy (LOI: 21.4% and UL 94-V: no rating) of simple epoxy resin was found to be failed the flame-retardant requirements.

Feasibility study of a dedicated nuclear desalination system: Low-pressure Inherent heat sink Nuclear Desalination plant (LIND)

  • Kim, Ho Sik;NO, Hee Cheon;Jo, YuGwon;Wibisono, Andhika Feri;Park, Byung Ha;Choi, Jinyoung;Lee, Jeong Ik;Jeong, Yong Hoon;Cho, Nam Zin
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.293-305
    • /
    • 2015
  • In this paper, we suggest the conceptual design of a water-cooled reactor system for a low-pressure inherent heat sink nuclear desalination plant (LIND) that applies the safety-related design concepts of high temperature gas-cooled reactors to a water-cooled reactor for inherent and passive safety features. Through a scoping analysis, we found that the current LIND design satisfied several essential thermal-hydraulic and neutronic design requirements. In a thermal-hydraulic analysis using an analytical method based on the Wooton-Epstein correlation, we checked the possibility of safely removing decay heat through the steel containment even if all the active safety systems failed. In a neutronic analysis using the Monte Carlo N-particle transport code, we estimated a cycle length of approximately 6 years under 200 $MW_{th}$ and 4.5% enrichment. The very long cycle length and simple safety features minimize the burdens from the operation, maintenance, and spent-fuel management, with a positive impact on the economic feasibility. Finally, because a nuclear reactor should not be directly coupled to a desalination system to prevent the leakage of radioactive material into the desalinated water, three types of intermediate systems were studied: a steam producing system, a hot water system, and an organic Rankine cycle system.

The effect of seasonal thermal stress on milk production and milk compositions of Korean Holstein and Jersey cows

  • Lim, Dong-Hyun;Mayakrishnan, Vijayakumar;Ki, Kwang-Seok;Kim, Younghoon;Kim, Tae-Il
    • Animal Bioscience
    • /
    • v.34 no.4
    • /
    • pp.567-574
    • /
    • 2021
  • Objective: In this study we investigated the effect of seasonal thermal stress on milk production and milk compositions between Holstein and Jersey dairy cows under the temperate-climate in Korea. Methods: A total of 9 Holstein lactating dairy cows (2.0±0.11 parity) which had a daily milk yield of 29.77±0.45 kg, and days in milk of 111.2±10.29 were selected similarly at the beginning of the experiments in each season. Also, a total of 9 Jersey lactating dairy cows (1.7±0.12 parity) which had a daily milk yield of 20.01±0.43 kg, and days in milk of 114.0±9.74 were selected similarly at the beginning of the experiments. Results: Results showed that the average ambient temperature (℃) and temperature-humidity index (THI) were higher in summer, and were lower in winter (p<0.05). The average relative humidity (RH, %) was higher in autumn than that of other seasons (p<0.05). Milk production was significantly decreased (Holstein 29.02 kg/d and Jersey 19.75 kg/d) in autumn than in other seasons (Holstein 30.14 kg/d and Jersey 20.96 kg/d). However, the milk production was negatively correlated in Holstein cows, and positively correlated in Jersey cows with THI values increased from 16 to 80. In addition, milk yield was increased by 15% in Holstein cows and decreased by 11% in Jersey cows with the THI values increased from 16 to 20. The fat and protein content percentage was significantly higher in Jersey milk than in Holstein milk, furthermore the fat and protein content yield was higher in Jersey cow milk than that of Holstein cow's milk with all THIs. Conclusion: From the study results, we concluded that Jersey cows might be less adaptable to low temperature of the winter, and this would have a negative impact on dairy farmer income since Korea's milk price estimation system places a higher value on milk yield than on milk compositions or sanitary grades.

A field Study to Evaluate Cooling Effects of Green Facade under Different Irrigation Conditions - Focusing on modular green facade planted with Hedera helix L and Pachysandra terminalis - (관수조절에 의한 벽면녹화의 냉각효과 분석 연구- 아이비, 수호초를 식재한 모듈형 벽면녹화를 중심으로-)

  • Kim, Eun-Sub;Yun, Seok-Hwan;Piao, Zheng-gang;Jeon, Yoon-Ho;Kang, Hye-Won;Kim, Sang-Hyuck;Kim, Ji-Yeon;Lee, Young-Gu;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.6
    • /
    • pp.121-132
    • /
    • 2021
  • Green facade has a significant impact on building's energy performance by controlling the absorption of solar radiation and improving outdoor thermal comfort through shading and evapotranspiration. In particular, since high-density building does not enough green space, green facade, and rooftop greening using artificial ground plants are highly utilized. However, the level of cooling effect according to plant traits and irrigation control is different. Therefore, in this study, the cooling effect analyzed for a total of 4 cases by controlling the irrigation condition based on hedera and spurge. Although hedera under sufficient water had the highest cooling effect(-2℃~-4℃), had the lowest cooling effect under non-irrigation(+1.1℃~+4.4℃). In addition, hedera under sufficient water had cooling effect than hedera under non-irrigation(-1℃~-8.1℃) and in the case of spurge, it had cooling effect(-0.3℃~-7.8℃) more than non-irrigation. As a result of measuring the amount of transpiration according to the light intensity (PAR) and carbon dioxide concentration conditions, transpiration of hedera was higher than the spurge (respectively 0.63204mmolm-2s-1, 0.674367mmolm-2s-1). The difference in the cooling effect of the green facade under irrigation condition was significant. But the potential cooling effect of green facade according to plants species was different. Therefore, in order to maximize and continuously provide the cooling effect of green facade in urban areas, it is necessary to consider the characteristics of plants and the control of water supply through the irrigation system.

Numerical Study of Heat Flux and BOG in C-Type Liquefied Hydrogen Tank under Sloshing Excitation at the Saturated State (포화상태에 놓인 C-Type 액체수소 탱크의 슬로싱이 열 유속과 BOG에 미치는 변화의 수치적 분석)

  • Lee, Jin-Ho;Hwang, Se-Yun;Lee, Sung-Je;Lee, Jang Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.35 no.5
    • /
    • pp.299-308
    • /
    • 2022
  • This study was conducted to predict the tendency for heat exchange and boil-off gas (BOG) in a liquefied hydrogen tank under sloshing excitation. First, athe fluid domain excited by sloshing was modeled using a multiphase-thermal flow domain in which liquid hydrogen and hydrogen gas are in the saturated state. Both the the volume of fluid (VOF) and Eulerian-based multi-phase flow methods were applied to validate the accuracy of the pressure prediction. Second, it was indirectly shown that the fluid velocity prediction could be accurate by comparing the free surface and impact pressure from the computational fluid dynamics with those from the experimental results. Thereafter, the heat ingress from the external convective heat flux was reflected on the outer surfaces of the hydrogen tank. Eulerian-based multiphase-heat flow analysis was performed for a two-dimensional Type-C cylindrical hydrogen tank under rotational sloshing motion, and an inflation technique was applied to transform the fluid domain into a computational grid model. The heat exchange and heat flux in the hydrogen liquid-gas mixture were calculated throughout the analysis,, whereas the mass transfer and vaporization models were excluded to account for the pure heat exchange between the liquid and gas in the saturated state. In addition, forced convective heat transfer by sloshing on the inner wall of the tank was not reflected so that the heat exchange in the multiphase flow of liquid and gas could only be considered. Finally, the effect of sloshing on the amount of heat exchange between liquid and gas hydrogen was discussed. Considering the heat ingress into liquid hydrogen according to the presence/absence of a sloshing excitation, the amount of heat flux and BOG were discussed for each filling ratio.

Properties on the Strength of Polymer Concrete Using Nano MMT-UP Composite (나노 MMT-폴리머 복합체를 이용한 폴리머 콘크리트의 강도 특성)

  • Jo, Byung-Wan;Moon, Rin-Gon;Park, Seung-Kook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.761-766
    • /
    • 2006
  • Polymer composite are increasingly considered as structural components for use in civil engineering, on account of their enhanced strength-to-weight ratios. Unsaturated polyester (UP) resin have been widely used for the matrix of composites such as FRP and polymer composite, due to its excellent adhesive. Polymer nanocomposites are new class of composites derived from the nano scale inorganic particles with dimensions typically in the range of 1 to 1000 nm that are dispersed in the polymer matrix homogeneously. Owing to the high aspect ratio of the fillers, mechanical, thermal, flame, retardant and barrier properties are enhanced without significant loss of clarity, toughness or impact strength. To prepare the MMT (Montmorillonite)-UP exfoliated nanocomposites, UP was mixed with MMT at $60^{\circ}C$ for 3 hours by using pan mixer. XRD (X-ray diffraction) pattern of the composites and TEM (Transmission Electron Micrographs) showed that the interlayer spacing of the modified MMT were exfoliated in polymer matrix. The mechanical properties also supported these findings, since in general, tensile strength, modulus with modified MMT were higher than those of the composites with unmodified MMT. The thermal stability of MMT-UP nanocomposite is better than that of pure UP, and its glass transition temperature is higher than that of pure UP. The polymer concrete made with MMT-UP nanocomposite has better mechanical properties than of pure UP. Therefore, it is suggested that strength and elastic modulus of polymer concrete was found to be positively tensile strength and tensile modulus of the MMT-UP nanocomposites.

Change in the Concrete Strength of Forest Road Drainage Systems Caused by Forest Fires (산불로 인한 임도 배수시설의 콘크리트 강도 변화)

  • Ye Jun Choe;Jin-Seong Hwang;Young-In Hwang;Hyeon-Jun Jeon;Hyeong-Keun Kweon;Joon-Woo Lee
    • Journal of Korean Society of Forest Science
    • /
    • v.112 no.4
    • /
    • pp.451-458
    • /
    • 2023
  • As forest fires continue to increase in scale worldwide, the importance of forest roads in relation to forest fire prevention and suppression has become increasingly evident. To ensure effective functioning during a forest fire disaster, it is crucial to apply appropriate road planning and ensure roads' structural integrity. However, previous studies have predominantly focused on the impact of forest fires on firebreak efficacy and road placement, meaning that insufficient attention has been paid to ensuring the safety of these facilities. Therefore, this study sought to compare the strength of concrete facilities within areas damaged by forest fires over the past three years by using the rebound hammer test to identify signs of thermal degradation. The results revealed that concrete facilities damaged by forest fires exhibited significantly lower strength (15.6 MPa) when compared with undamaged facilities (18.0 MPa) (p<0.001), and this trend was consistent across all the target facilities. Consequently, it is recommended that safety assessment criteria for concrete forest road facilities be established to prevent secondary disasters following forest fire damage. Moreover, continuous monitoring and research involving indoor experiments are imperative in terms of enhancing the stability of forest road structures. It is expected that such research will lead to the development of more effective strategies for forest fire prevention and suppression.

Bending analysis of nano-Fe2O3 reinforced concrete slabs exposed to temperature fields and supported by viscoelastic foundation

  • Zouaoui R. Harrat;Mohammed Chatbi;Baghdad Krour;Sofiane Amziane;Mohamed Bachir Bouiadjra;Marijana Hadzima-Nyarko;Dorin Radu;Ercan Isik
    • Advances in concrete construction
    • /
    • v.17 no.2
    • /
    • pp.111-126
    • /
    • 2024
  • During the clinkering stages of cement production, the chemical composition of fine raw materials such as limestone and clay, which include iron oxide (Fe2O3), silicon dioxide (SiO2) and aluminum oxide (Al2O3), significantly influences the quality of the final product. Specifically, the chemical interaction of Fe2O3 with CaO, SiO2 and Al2O3 during clinkerisation plays a key role in determining the chemical reactivity and overall quality of the final cement, shaping the properties of the concrete produced. As an extension, this study aims to investigate the physical effects of incorporating nanosized Fe2O3 particles as fillers in concrete matrices, and their impact on concrete structures, namely slabs. To accurately model the reinforced concrete (RC) slabs, a refined trigonometric shear deformation theory (RTSDT) is used. Additionally, the stochastic Eshelby's homogenization approach is employed to determine the thermoelastic properties of nano-Fe2O3 infused concrete slabs. To ensure comprehensive coverage in the study, the RC slabs undergo various mechanical loads and are exposed to temperature fields to assess their thermo-mechanical performance. Furthermore, the slabs are assumed to rest on a three-parameter viscoelastic foundation, comprising the Winkler elastic springs, Pasternak shear layer and a damping parameter. The equilibrium governing equations of the system are derived using the principle of virtual work and subsequently solved using Navier's technique. The findings indicate that while ferric oxide nanoparticles enhance the mechanical properties of concrete against mechanical loading, they have less favorable effects on its performance against thermal exposure. However, the viscoelastic foundation contributes to mitigating these effects, improving the concrete's overall performance in both scenarios. These results highlight the trade-offs between mechanical and thermal performance when using Fe2O3 nanoparticles in concrete and underscore the importance of optimizing nanoparticle content and loading conditions to improve the structural performance of concrete structures.