• Title/Summary/Keyword: thermal distribution

Search Result 3,035, Processing Time 0.031 seconds

A study of the simulation of thermal distribution in an aquifer thermal energy storage utilization model (대수층 축열 에너지 활용 모델의 온도 분포 시뮬레이션 연구)

  • Shim, Byoung-Ohan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.697-700
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) system can be very cost-effective and renewable energy sources, depending on site-specific parameters and load characteristics. In order to develop an ATES system which has certain hydrogeological characteristics, understanding of the thermo hydraulic processes of an aquifer is necessary for a proper design of an aquifer heat storage system under given conditions. The thermo hydraulic transfer for heat storage is simulated using FEFLOW according to two sets of pumping and waste water reinjection scenarios of heat pump operation in a two layered confined aquifer. In the first set of model, the movement of the thermal front and groundwater level are simulated by changing the locations of injection and pumping well in seasonal cycle. However, in the second set of model the simulation is performed in the state of fixing the locations of pumping and injection well. After 365 days simulation period, the temperature distribution is dominated by injected water temperature and the distance from injection well. The small temperature change is appears on the surface compared to other slices of depth because the first layer has very low porosity and the transfer of thermal energy are sensitive at the porosity of each layer. The groundwater levels and temperature changes in injection and pumping wells are monitored to validate the effectiveness of the used heat pump operation method and the thermal interference between wells is analyzed.

  • PDF

Aanalysis the Structure of Heat Environment in Daegu Using Landsat-8 (Landsat-8을 활용한 대구시 열 환경구조 분석)

  • Kim, Jun Hyun;Choi, Jin Ho
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.4_1
    • /
    • pp.327-333
    • /
    • 2014
  • To improve thermal environments in urban area, the structural characteristic analysis of thermal environments of the certain area should be preceded to analyze and supplement its problems. With Landsat-8, we measured the centrality estimation, the distribution map, and the spatial statistical analysis of Daegu Metropolitan City in January and August, which of data applied in analyzing the structure of thermal environments following to its spatial property. The thermal infrared band of satellite images has been used to analyze the standard normal deviated scores, which extract the centrality, while the cluster map, based upon Local Local Moran's I, has composed for understanding the autocorrelation of local spatial within environment space structure. Understanding the distribution features as well as the pivot center of thermal environments with satellite images provides principle database for updating urban thermal environments' policies and plans; because those are reference materials that should have precedence over for diverse thermal environment policies.

Thermal buckling analysis of embedded graphene-oxide powder-reinforced nanocomposite plates

  • Ebrahimi, Farzad;Nouraei, Mostafa;Dabbagh, Ali;Rabczuk, Timon
    • Advances in nano research
    • /
    • v.7 no.5
    • /
    • pp.293-310
    • /
    • 2019
  • In this paper, thermal-buckling behavior of the functionally graded (FG) nanocomposite plates reinforced with graphene oxide powder (GOP) is studied under three types of thermal loading once the plate is supposed to be rested on a two-parameter elastic foundation. The effective material properties of the nanocomposite plate are considered to be graded continuously through the thickness according to the Halpin-Tsai micromechanical scheme. Four types of GOPs' distribution namely uniform (U), X, V and O, are considered in a comparative way in order to find out the most efficient model of GOPs' distribution for the purpose of improving the stability limit of the structure. The governing equations of the plate have been derived based on a refined higher-order shear deformation plate theory incorporated with Hamilton's principle and solved analytically via Navier's solution for a simply supported GOP reinforced (GOPR) nanocomposite plate. Some new results are obtained by applying different thermal loadings to the plate according to the GOPs' negative coefficient of thermal expansion and considering both Winkler-type and Pasternak-type foundation models. Besides, detailed parametric studies have been carried out to reveal the influences of the different types of thermal loading, weight fraction of GOP, aspect and length-to-thickness ratios, distribution type, elastic foundation constants and so on, on the critical buckling load of nanocomposite plates. Moreover, the effects of thermal loadings with various types of temperature rise are investigated comparatively according to the graphical results. It is explicitly shown that the buckling behavior of an FG nanocomposite plate is significantly influenced by these effects.

Thermal Fluid Flow Analysis for Temperature Characterization of Mold Transformer in Distribution Power System (배전용 몰드변압기의 온도특성 파악을 위한 열유동해석)

  • Kim, Ji-Ho;Lee, Jeong-Gun;Lee, Ki-Sik;Rhee, Wook;Lee, Hyang-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.6-11
    • /
    • 2013
  • In this paper, the temperature characteristics of mold transformer for the distribution power system have been analyzed by using computational fluid dynamics(CFD). The model has been modeled by coil, cores, insulating materials and frames about 3MVA grade mold transformer and analyzed the temperature distribution of the structure with a heat fluid. The fluid, which is incompressible ideal gas, is analyzed as a turbulent flow phenomenon on the assumption that it is natural cooling of transformer cooling system. Through this study, by examining the temperature distribution and hot-spot of the structure field of the mold transformer, cooling design and temperature distribution information, which are demanded for designing are estimated.

The Design and Performance Test of Mold Transformer for Outdoor Pole (50 kVA 주상용 몰드변압기의 설계 및 특성평가)

  • Cho, Han-Goo;Lee, Un-Yong;HwangBo, Kuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.132-137
    • /
    • 2002
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss. The life of transformer is significantly dependent on the thermal behavior in windings. To analyse winding temperature rise, many transformer designer have calculated temperature distribution and hot spot point by finite element method(FEM). Recently, numerical analyses of transformer are studied for optimum design, that is electric field analysis, magnetic field, potential vibration, thermal distribution and thermal stress. In this paper, the temperature distribution of 50 kVA pole mold transformer for power distribution are investigated by FEM program and the temperature rise test of designed mold transformer carried out and test result is analyzed compare to simulation data. In this result, the designed mold transformer is satisfied to limit value of temperature and the other property is good such as voltage ratio, winding resistance, no-load loss, load loss, impedance voltage and percent regulation.

  • PDF

Thermal Comfort Condition of Temperature and Humidity in Loess Interior Space

  • Kong, Sung-Hoon
    • Biomedical Science Letters
    • /
    • v.10 no.2
    • /
    • pp.129-135
    • /
    • 2004
  • The study was carried out through measuring the temperature and humidity of the indoor/outdoor space and the distribution of interior thermal condition, and investigating the effect of loess materials on human body. The purpose of this study is to analyze the change of dry bulb temperature and relative humidity and correlation of thermal reaction of human body with ASHRAE (American Society of Heating, Refrigerating and Air-conditioning) comfort chart in the loess interior space. In the view point of biomedical sciences, loess interior space provides optimum thermal conditions for human thermal sensation.

  • PDF

Thermal Stress Analysis of Ventilated Disc Brake (벤틸레이티드 디스크 브레이크의 열응력 해석)

  • Kim, Yang-Sul;An, Su-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.3
    • /
    • pp.25-29
    • /
    • 2008
  • In automotive disc brake system, friction heat is not uniformly distributed due to various reasons such as thermal expansion and imperfections in geometry. It is well known that thermoelastic distortion due to fictional heating affects the contact pressure distribution and can lead to thermoelastic instability, where the contact load is concentrated in one or more small regions on the brake disc surface. These regions then take very high temperatures and passage of hot spots moving under the brake pads can cause low frequency vibration called brake judder. This paper presents the FEM(finite element method) result for the temperature distribution of ventilated disc brake. A steady state two-dimensional model of disc brake system predicts the surface temperatures during a multi-stop driving schedule.

Temperature Distribution and Thermal Stresses of Infinite Plate due to Tandem Arc Welding (Tandem熔接으로 因한 溫度分布 및 熱應力)

  • Kim, Hyo-Chul;Lee, Jun-Yeol
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.14 no.3
    • /
    • pp.5-12
    • /
    • 1977
  • In shipyard production processes, lots of steel plates are assembled by welding. Some rectangular steel plates are buttwelded to build a large block in panel production lines. There are some advantages to take the tandem arc welding in butt joints of rectangular plates with respect to welding speed. Hence, the thermal stresses and the temperature distribution of the tandem arc welding are studied in this paper. The solutions in the case of the infinite plate with two instantaneous point heat sources have been obtained. And then the solutions have been extended to the case of two moving heat sources corresponding to the tandem arc welding with the aid of Duhamel's superposition integral. It was found that the temperature distribution was good agreement with the results of the experiments by Rosenthal and Park and the thermal stresses calculated were acceptable with respect to a physical phenomenon. These solutions are able to be applied to the problem such as a line heating.

  • PDF

Fatigue Life Analysis on Multi-Stacked Film Under Thermal and Residual Stresses (열응력과 잔류응력하의 다층박막의 피로수명 해석)

  • Park Jun-Hyub
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.4 s.235
    • /
    • pp.526-533
    • /
    • 2005
  • Reliability problem in inkjet printhead, one of MEMS devices, is also very important. To eject an ink drop, the temperature of heater must be high so that ink contacting with surface reaches above $280^{o}C$ on the instant. Its heater is embedded in the thin multi-layer in which several materials are deposited. MEMS processes are the main sources of residual stresses development. Residual stress is one of the factors reducing the reliability of MEMS devices. We measured residual stresses of single layers that consist of multilayer. FE analysis is performed using design of experiment(DOE). Transient analysis for heat transfer is performed to get a temperature distribution. And then static analysis is performed with the temperature distribution obtained by heat transfer analysis and the measured residual stresses to get a stress distribution in the structure. Although the residual stress is bigger than thermal stress, thermal stress is more influential on fatigue life.

A Study of defect distribution and profiles of MeV implanted phosphorus in silicon (실리콘에 MaV로 이온주입된 인의 결함분포와 profile에 관한 연구)

  • 정원채
    • Electrical & Electronic Materials
    • /
    • v.10 no.9
    • /
    • pp.881-888
    • /
    • 1997
  • This study demonstrats the profiles of phosphorus ions in silicon by MeV implantation(1∼3 MeV). Implanted profiles could be measured by SIMS(Cameca 4f) and compared with simulation results(TRIM program and analytical description method only using on Pearson function). The experimental result in the peak concentration region has a little bit deviation from simulation data. By RBS and Channeling measurements the defect distribution of implanted samples could be measured and spectrum are calibrated depth with RUMP simulation By XTEM measurement the thickness of defect zone also could be measured. Finally thermal annealing for the electrical activation of implanted ions carried out by RTA(rapid thermal annealing). The concentration-depth profiles after heat treatment was measured by SR(spreading resistance)-method.

  • PDF