• 제목/요약/키워드: thermal discharge

검색결과 627건 처리시간 0.026초

Numerical Simulation of the Water Temperature in the Al-Zour Area of Kuwait

  • Lee, Myung Eun;Kim, Gunwoo
    • 해양환경안전학회지
    • /
    • 제25권3호
    • /
    • pp.334-343
    • /
    • 2019
  • The Al-Zour coastal area, located in southern Kuwait, is a region of concentrated industrial water use, seawater intake, and the outfall of existing power plants. The Al-Zour LNG import facility project is ongoing and there are two issues regarding the seawater temperature in this area that must be considered: variations in water temperature under local meteorology and an increase in water temperature due to the expansion of the thermal discharge of expanded power plant. MIKE 3 model was applied to simulate the water temperature from June to July, based on re-analysis data from the European Centre for Medium-Range Weather Forecasts (ECMWF) and the thermal discharge input from adjacent power plants. The annual water temperatures of two candidate locations of the seawater intake for the Al-Zour LNG re-gasification facility were measured in 2017 and compared to the numerical results. It was determined that the daily seawater temperature is mainly affected by thermal plume dispersion oscillating with the phase of the tidal currents. The regional meteorological conditions such as air temperature and tidal currents, also contributed a great deal to the prediction of seawater temperature.

원자력발전소의 온배수 배출해역에서 대형 저서동물 군집구조의 차이 (Difference in Macrobenthic Community Structures at Thermal Effluent Discharge Areas of Two Nuclear Power Plants in Korea)

  • 맹준호;김근용;김영윤;손명백;김진희;손민호
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권3호
    • /
    • pp.157-165
    • /
    • 2015
  • 본 연구는 고리원자력발전소와 신고리원자력발전소로부터 배출되는 온배수의 영향을 받는 해역에서 퇴적물 특성과 대형 저서동물의 군집구조를 조사하고 비교하였다. 두 배출해역의 퇴적물 특성들 중에서 모래와 펄, 유기물의 함량이 통계적으로 유의한 차이를 보였다. 대형 저서동물의 출현종과 개체 수는 고리원자력발전소보다 신고리원자력발전소의 배출해역에서 더 많았으며, 그 수는 이전의 다른 연구결과들과 유사한 수준이었다. 두 원자력발전소의 온배수 배출해역은 퇴적물 특성과 대형 저서동물의 출현종 수에서 유의한 차이를 보였다.

Investigation of Spark Discharge in Water as a Source of Mechanical Actuation

  • Taylor, Nathaniel D.;Fridman, Gregory;Fridman, Alexander;Dobrynin, Danil
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.258-258
    • /
    • 2014
  • Spark discharge in water generates shockwaves which have been utilized to generate mechanical actuation for potential use in pumping application. Discharge pulses of several microseconds generate shockwaves and vapor bubbles which subsequently displace the water for a period of milliseconds. Through the use of a sealed discharge chamber and metal bellow spring, the fluid motion can be used create an oscillating linear actuator. Continuous actuation of the bellow has been demonstrated through the use of high frequency spark discharge. Discharge in water forms a region of high electric field around the electrode tip which leads to the creation of a thermal plasma channel. This process produces fast thermal expansion, vapor and bubble generation, and a subsequent shockwave in the water which creates physical displacement of the water [1]. Previous work was been conducted to utilize the shockwave effect of spark discharge in water for the inactivation of bacteria, removal of mineral fouling, and the formation of sheet metal [2-4]. Pulses ranging from 25 to 40 kV and 600 to 900 A are generated inside of the chamber and the bellow motion is captured using a slow motion video camera. The maximum displacements measured are from 0.7 to 1.2 mm and show that there is a correlation between discharge energy input to the water and the displacement that is generated. Subsequent oscillations of the bellow are created by the spring force of the bellow and vapor in the chamber. Using microsecond shutter speed ICCD imaging, the development of the discharge bubble and spark can be observed and measured.

  • PDF

Non-thermal Plasma Discharge를 이용한 $NO_x$ 제거에 관한 연구 (A Study on the removal of $NO_x$ by using Non-thermal Plasma Discharge)

  • 안정언;이석현;정용원
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2001년도 추계학술대회 논문집
    • /
    • pp.419-420
    • /
    • 2001
  • 최근 산업설비 및 기타 시설에서 배출되는 유해가스의 배출허용 기준이 계속 강화되고 있으며 그 중에서도 NOx는 SOx와 함께 대기오염의 주된 원인으로 작용하고 있다. 국내에서도 이들 유해가스를 제거하기 위한 플라즈마 적용기술이 활발히 연구되었으며, 일부 기술은 상용화 단계에 있다. NOx 제거에 있어서 펄스 코로나 방전에 의한 전자의 생성은 유입되는 가스 및 공기에 충돌하여 반응성이 큰 다량의 이온, 원자 및 radical(N, O, OH, $O_3$등)을 생성한다. (중략)

  • PDF

원자력 발전소 온배수 피해역 산정을 위한 영향지수 시안 (Thermal Index for the Assessment of the Impacted Area by the Thermal Discharge from Nuclear Power Plant in Korea)

  • 노영재
    • 한국해양학회지:바다
    • /
    • 제12권1호
    • /
    • pp.35-42
    • /
    • 2007
  • 국내 원자력 발전소의 온배수 배출을 둘러싸고 제기된 각 종 수산업 피해 민원이 발생한지도 20년이 가까워 온다. 온배수에 의한 연안환경 및 수산업 피해를 보다 과학적이고 합리적으로 산정하기 위한 지침이 한국 해양학회, 수산학회 공동의 노력으로 마련되었다. 피해역 산정 방안을 보다 합리적으로 마련하기 위하여 기존의 특정 상승온도 기준을 탈피하고 환경과 생태계의 다양한 영향을 포괄적으로 고려할 수 있는 온배수 영향지수를 제안하였다. 이 영향지수는 UNEP(2002)의 권고안에 따른 지침을 수용하고, 현실성과 경제성 및 미래지향적 특성을 갖출 수 있다. 특정 원자력발전소 현장에 적용 가능한 영향지수의 구현을 위하여 예비 실험의 노력이 요구된다.

적외선방사카메라를 이용한 변압기 온도분포 모니터링 (Temperature Distribution Monitoring of Transformer Using IRR-Camera)

  • 이우선;정찬문;서용진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

전산해석을 통한 열증기압축기 설계와 실험적 검증 (Design of Thermal Vapor Compressor by Numerical Analysis and Experimental Verification)

  • 박일석;박상민;하지수
    • 한국유체기계학회 논문집
    • /
    • 제8권6호
    • /
    • pp.33-39
    • /
    • 2005
  • A thermal vapor compressor in which the subsonic/supersonic flow appears simultaneously, has been accurately designed through the CFD analysis for the various shape parameters such as the primary nozzle shape, converging duct shape, mixing tube diameter, and so on. The performance of the developed thermal vapor compressor has been experimentally verified to be installed in a Multi Effect Desalination(MED) plant as an important element. In this paper, the effects of each parameter are discussed on the basis of CFD results and the experimental results for various boundary conditions(motive pressure, suction pressure, and discharge pressure) are presented in compared with CFD results. The two results show a good agreement with each other within 2 % accuracy with regard to the entrainment ratio.

변압기 온도 변화특성 모니터링 (Temperature Distribution Monitoring of Transformer)

  • 이우선;정찬문;손동민;서용진;임장섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

화상처리를 이용한 방전와이어의 성능평가에 대한 연구 (A Study on the efficiency test of Electric Discharge Machine Wire using Image processing)

  • 배진한;이위로;유송민
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.117-122
    • /
    • 2002
  • Electrical discharge machining uses thermal energy from electrical discharge, while wire electrical discharge machining (WEDM) technology is widely used in conductive material machining. This paper proposes a method for evaluating the characteristics of wires in WEDM. In order to evaluate the wire processing performance, processing speed and roughness, straightness, corner processing have been assessed with precision experiment equipment and image processing including Laplacian filtering with various threshold levels.

  • PDF

SEBIM POSRV 방출배관계통의 수력학적 하중계산을 위한 RELAP5 / MOD3 분석 (RELAP5/MOD3 Analysis for Hydraulic Load Calculation of the SEBIM POSRV Discharge Riping System)

  • Han, Kee-Soo;Song, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제26권2호
    • /
    • pp.225-236
    • /
    • 1994
  • SEBIM 밸브 상부에 위치한 밀봉수의 급격한 방출은 밸브 후단의 방출배관계통에 큰 운동량과 관성력의 작용을 초래한다. 본 연구는 밸브개방시 방출배관계통의 후단에 발생하는 열수력학적 과도현상을 분석하기 위한 해석절차 및 해석결과를 다루고 있으며, 이 분석을 위해 RELAP5 /MOD3 를 사용하였다. RELAP5 /MOD3 분석을 위하여, 방출관 계통과 SEBIM 밸브의 개방특성 및 밀봉수 방출등의 적절한 모델방법이 제시되었다. 또한 접합부(junction)와 체적(volume)의 제어 플래그 (flag)에서 옵션(option)의 적절한 선택을 위하여 민감도분석도 수행되었다. 분석결과, SEBIM 밸브 방출배관계통의 밀봉수 방출에 따른 열수력학적 과도현상을 분석하는데 RELAP5 /MOD3가 적절히 사용될 수 있음을 알 수 있었다. 민감도 분석결과로부터, 밀봉수 방출해석을 위해서는 적절한 기하학적 압력분포를 가지는 완만한(smooth) 면적변화 및 비평형 옵션(option), 적절한 시간간격(time step)의 사용이 필수적인 것을 알 수 있었다.

  • PDF