• 제목/요약/키워드: thermal degradation pattern

검색결과 15건 처리시간 0.028초

모델식품계에서 무산소 가열시 토코페롤의 열분해 패턴 (Thermal Degradation Pattern of Tocopherols on Heating without Oxygen in a Model Food System)

  • 정혜영
    • 한국식품영양학회지
    • /
    • 제11권6호
    • /
    • pp.635-639
    • /
    • 1998
  • The thermal degradation pattern of $\alpha$-, ${\gamma}$-and $\delta$-tocopherols in glycerol was investigated during heating at 100~25$0^{\circ}C$ for 5-60 min in the absence of oxyge. The tocopherols and thermally decomposed products were separated by HPLC with a reversed phase $\mu$-Bondapak C18-column. The degradation pattern of $\alpha$-tocopherol during the heating in the absence of oxygen was different from those of ${\gamma}$-and $\delta$-tocopherols. But the degradation patterns of ${\gamma}$-and $\delta$-tocopherols were similar to each other. The residual content of $\alpha$-tocopherol during the heating in the absence of oxygen decreased to the range 12~65% and those of ${\gamma}$-and $\delta$-tocopherols decreased to the range 4~96%. The thermal degradation of tocopherols in the absence of oxygen was less than that in the presence of oxygen.

  • PDF

적외선방사카메라를 이용한 변압기 온도분포 모니터링 (Temperature Distribution Monitoring of Transformer Using IRR-Camera)

  • 이우선;정찬문;서용진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.459-462
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of Power transformer is measured with partial temperature distribution in real time.

  • PDF

변압기 온도 변화특성 모니터링 (Temperature Distribution Monitoring of Transformer)

  • 이우선;정찬문;손동민;서용진;임장섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

Analysis of Alizarin Dye in Accelerated Degradation Conditions

  • Ahn, Cheunsoon
    • The International Journal of Costume Culture
    • /
    • 제7권1호
    • /
    • pp.40-47
    • /
    • 2004
  • The purpose of this research was to examine the degradation rate of alizarin in accelerated degradation conditions using the GC-MS quantitative analysis. Alizarin dye solution (2.5 x 10/sup -3/ M conc.) were kept in 150℃ oven for total of 7 days and the degradation rate was examined each day. 2.5 × 10/sup -4/M conc. alizarin dye solution was mixed with H₂O₂ according to [H₂O₂]/[dye] ratio 40 and were kept under 365㎚ UV for 2 hours, analyzed after 0, 30, 60, 90, 120min using the GC-MS. Gas chromatogram showed alizarin peak at 9.96 - 10.13 min. retention time range and residual peaks in the wide range from 9.6 to 11.1 min. Oven degradation exhibited an initial decrease in the amount of alizarin, which was followed by increasing amount in 4/sup th/ day. The decrease in the alizarin was significantly shown by the 7/sup th/ day. Same pattern was also observed in the H₂O₂/UV/O₂ degradation samples and was verified ed by the UV-VIS spectra. The differences in the amount of alizarin between 1/sup st/ day and 4/sup th/ day samples, 4/sup th/ day and 7/sup th/ day samples, and Control and 7/sup th/ day samples of the oven degradation were significant at alpha .20.

  • PDF

Enhanced Thermal Stability of a Novel Human Thrombopoietin Mutein under the Various Temperature Conditions

  • Kim, Tae-Soo;Ahn, Hye-Kyung;Lim, Seung-Wook;Hong, Yeon-Joo;Chung, Joo-Young;Koh, Yeo-Wook
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.237.2-237.2
    • /
    • 2003
  • DWP40458 is a novel human thrombopoietin mutein with two additional N-linked glycosylation site. The thermal stability of DWP40458 in both solution and lyophilized form was studied in the temperature range of 4-50$^{\circ}C$, compared with recombinant human TPO (rhTPO). When the aggregation or degradation pattern of DWP40458 and rhTPO solution was characterized by using SDS-PAGE, gel permeation chromatography (GPC) and reverse phase HPLC, it was found that thermostability of DWP40458 was significantly different to rhTPO in the temperature at 25, 40, 40, 50$^{\circ}C$. (omitted)

  • PDF

부분방전 패턴분석에 의한 고압유도전동기 무정전 진단기법 연구 (A study on the On-Line Diagnostic Technique of High Voltage Induction Motor by partial discharge Pattern Analysis)

  • 정영일;이은석;김덕근;임용배;김종서
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1685-1687
    • /
    • 2002
  • High voltage(H.V.) induction motors have been applied to various industrial applications. But aging and failure of induction motors are initiated by electrical, mechanical, thermal and chemical processes during manufacturing or in-service. These detects reduce locally the dielectric strength of the insulation. At such defects partial discharges can occur, which cause further degradation of the insulation and reduce the life time of the H.V induction motors. Consequently in this paper, we studied the partial discharge pattern analysis of H.V. induction motor for on-site applications.

  • PDF

가스분해 분석기법을 활용한 가스 전열 변압기의 상태 진단 연구 (A Study on the Condition Diagnosis for A Gas-insulated Transformer using Decomposition Gas Analysis)

  • 김아름;곽병섭;전태현;박현주
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.119-126
    • /
    • 2022
  • A growing number of gas-insulated transformers in underground power substations in urban areas are approaching 20 years of operation, the time when failures begin to occur. It is thus essential to prevent failure through accurate condition diagnosis of the given facility. Various solid insulation materials exist inside of the transformers, and the generated decomposition gas may differ for each gas-insulated equipment. In this study, a simulation system was designed to analyze the deterioration characteristics of SF6 decomposition gas and insulation materials under the conditions of partial discharge and thermal fault for diagnosis of gas-insulated transformers. Degradation characteristics of the insulation materials was determined using an automatic viscometer and FT-IR. The analysis results showed that the pattern of decomposition gas generation under partial discharge and thermal fault was different. In particular, acetaldehyde was detected under a thermal fault in all types of insulation, but not under partial discharge or an arc condition. In addition, in the case of insulation materials, deterioration of the insulation itself rapidly progressed as the experimental temperature increased. It was confirmed that it was possible to diagnose the internal discharge or thermal fault occurrence of the transformer through the ratio and type of decomposition gas generated in the gas-insulated transformer.

2차원 구조와 3차원 구조에 따른 멀티코어 프로세서의 온도 분석 (Thermal Pattern Comparison between 2D Multicore Processors and 3D Multicore Processors)

  • 최홍준;안진우;장형범;김종면;김철홍
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권9호
    • /
    • pp.1-10
    • /
    • 2011
  • 동작 주파수의 증가는 싱글코어 프로세서의 성능을 크게 향상시키는 반면 전력 소모 증가와 높은 온도로 인한 신뢰성 저하 문제를 유발하고 있다. 최근에는 싱글코어 프로세서의 한계점을 극복하기 위한 대안으로 멀티코어 프로세서가 주로 사용되고 있다. 하지만, 멀티코어 프로세서를 2차원 구조로 설계하는 경우에는 내부 연결망에서의 전송 지연 현상으로 인해 프로세서의 성능 향상이 제약을 받고 있다. 내부 연결망에서의 전송 지연을 줄이기 위한 방안으로 멀티코어 프로세서를 3차원 구조로 설계하는 연구가 최근 큰 주목을 받고 있다. 2차원 구조 멀티코어 프로세서와 비교하여 3차원 구조 멀티코어 프로세서는 성능 향상과 전력 소모 감소의 장점을 지닌 반면, 높은 전력 밀도로 인해 발생된 발열 문제가 프로세서의 신뢰성을 위협하는 문제가 되고 있다. 3차원 멀티코어 프로세서에서 발생되는 발열 문제에 대한 상세한 분석이 제공된다면, 프로세서의 신뢰성을 확보하기 위한 연구 진행에 큰 도움이 될 것으로 기대된다. 그러므로 본 논문에서는 3차원 멀티코어 프로세서의 온도에 밀접하게 연관된 요소인 작업량, 방열판과의 거리, 그리고 적층되는 다이의 개수와 온도 사이의 관계를 자세히 살펴보고 높은 온도가 프로세서의 성능에 미치는 영향 또한 분석하고자 한다. 특히, 2차원 구조 멀티코어 프로세서와 3차원 구조 멀티코어 프로세서에서의 온도 문제를 함께 분석함으로써, 온도 측면에서 효율적인 프로세서 설계를 위한 가이드라인을 제시하고자 한다.

Structural and thermal characteristics of photocrosslinked silk fibroin - PEG hydrogel

  • Jo, You-Young;Lee, Kwang-Gill;Bragg, John C.;Lin, Chien-Chi;Kweon, HaeYong
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제32권1호
    • /
    • pp.35-40
    • /
    • 2016
  • Hydrogels are crosslinked hydrophilic matrices for a variety of biomedical applications. Silk fibroin (SF), one of typical natural biomaterials, has been explored as base material for hydrogel. Photocrosslinked SF hydrogel containing poly(ethylene glycol) (PEG) was formulated through visible light initiated thiol-acrylate photopolymerization. The morphological, structural and thermal properties of SF - PEG hydrogel was investigated through scanning electron microscopy, X-ray diffractometry, thermogravimetry, and differential scanning calorimetry. The morphology of SF hydrogel showed dot and uneven surface with network cross-section. X-ray diffraction curves showed that the specific diffraction peaks of PEG were not changed by the intensity of the peaks were affected by sonication. Thermo-degradation behavior of SF - PEG hydrogel sonicated was significantly affected and became complex pattern compared to unsonicated ones. However, the melting endothermic temperature of SF - PEG hydrogel was not changed but the crystalline enthalpy was decreased by gelation and sonication.

신규(新規) 살충제(殺蟲劑)인 O, O, O-Diethyl-O-(1-phenyl-3-trifluoromethyl-5-pyrazoyl) thiophosphoric acid ester의 열(熱)에 의한 분해성(分解性) (Thermal Decomposition of A New Insecticide KH-502 [O, O-Diethyl O-(1-phenyl -3-trifluoromethy-5-pyrazoyl) thiophosphoric acid ester])

  • 조부연;한대성
    • 한국환경농학회지
    • /
    • 제11권3호
    • /
    • pp.225-234
    • /
    • 1992
  • Thermal decomposition was conducted to investigate the influence of the various factors on stability of a new insecticide, [O, O-Diethyl O-(1-phenyl-3-trifluoromethyl-5-pyrazoyl) thiophosphoric acid ester : KH-502], in view of those informations applicable for industrial exploitation. In the thermal decomposition experiment, KH-502 was, after mixing with Fe, Cu and adjustment of moisture and pH conditions, subjected to three temperatures, 25, 50, and $100^{\circ}C$. Results for stability, and degradation pattern of KH-502 from the above experiment can be summarized as follows: 1. Main products of the thermal decomposition when this was conducted in the closed system were identified as following five compounds:O, O, O-Triethylthiophosphoric acid(TEPA), 1-Phenyl-3-trifluoromethyl-5-ethoxypyrazole(PTMEP), 1-Phenyl-2-ethyl-3-trifluoromethyl-5-hydroxypyrazole(PETMHP), O, O-Diethyl O-(1-phenyl-3-trifluoromethyl-5-pyrazoyl)phosphoric acid ester(KH-502 oxo form), O, S-Diethyl O-(1-phenyl-3-trifluoromethyl-5-pyrazoyl)phospho rothiolate(S-ethyl KH-502). However, compounds such as oxo form and S-ethyl KH-502 were not identified when the thermal decomposition was proceeded in the open system. 2. KH-502 was stable at 25 and 50$^{\circ}C$, but it was decomposed at 100$^{\circ}C$ following the first-order kinetics at the early stages of decomposition. 3. Rate constants for the thermal decomposition of KH-502 at 100$^{\circ}C$ were in the orders of Cu powder addition 0.344>Cu plate addition 0.21>moisture addition 0.05>closed system=open system=iron addition=pH 5.5 adjustment 0.04>pH 8.5 adjustment 0.027 day$^{-1}$, representing KH-502 was decomposed fast at Cu powder treatment and slow at pH 8.5 adjustment. 4. Half-life for the thermal decomposition of KH-502 at 100$^{\circ}C$ was in the orders of Cu powder addition 2.02

  • PDF