• Title/Summary/Keyword: thermal cycling control

Search Result 22, Processing Time 0.024 seconds

THE EFFECTS OF THERMAL CYCLING ON THE BOND STRENGTH OF SELF-CURING RESIN (Thermal Cycling에 따른 자가중합 레진의 결합강도에 관한 연구)

  • Cho, Hye-Won;Ha, Jum-In
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.697-705
    • /
    • 1997
  • The purpose of this study was to evaluate the effects of two metal adhesive primers on the shear bond strengths of self-curing resin to Ni-Cr a]toy and the effects of 1000 thermal cycling on the durability of the bond. The two selected metal adhesive primers were Metal Primer II(G-C corp., Japan) and MR Bond(Tokuyama corp., Japan) and no treatment groups were used as control. All specimens were divided into two groups according to thermal cycling. In the group without thermal cycling, the specimens were stored in water for 24 hours. In the group with thermal cycling, the specimens were thermocycled 1000 times at temperature of $5^{\circ}C\;and\;55^{\circ}C$. Shear bond strengths were measured using the Universal testing machine(Zwick 145641, Germany) with a crosshead speed of 0.5 mm/min. The results were as follows: 1. MR Bond significantly improved the shear bond strength of resin to Ni-Cr alloy before and after thermal cycling. 2. There were no difference in the shear bond strength of resin to Ni-Cr alloy between Metal Primer II treated group and no treatment group. 3. Regardless of the type and the use of adhesive primers, there were tendency of decrease in shear bond strength with 1000 thermal cycling.

  • PDF

Thermal Cycling Control System Design for Polymerase Chain Reaction(PCR) Machine (중합효소연쇄반응 기기의 온도 사이클링 제어시스템 설계)

  • Kim Jong-Hae;Cho Yong-Seuk;Oh Do-Chang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.5
    • /
    • pp.419-424
    • /
    • 2006
  • In this study, a thermal control system which applied a Peltier device for the polymerase chain reaction(PCR) machine is to be designed. Here in order for it to easily follow the characteristics of the thermal cycle existing for gene amplification of the PCR sample, a PCR control board utilizing a thermal sensor, a Peltier, and a 8 bit microprocessor is made up. Especially a fuzzy type PD control algorithm is applied periodically in time response, and control system is implemented. For that matter, the characteristic data of subject system is obtained and analysed to begin with. Based on this analysed data, the proposed control algorithm is applied and an evaluation of the performance of the whole system take place through the PC.

Repair bond strength of composite resin to zirconia restorations after different thermal cycles

  • Cinar, Serkan;Kirmali, Omer
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.297-304
    • /
    • 2019
  • PURPOSE. This in vitro study investigated the repair bond strength of the zirconia ceramic after different aging conditions. MATERIALS AND METHODS. In order to imitate the failure modes of veneered zirconia restorations, veneer ceramic, zirconia, and veneer ceramic-zirconia specimens were prepared and were divided into 4 subgroups as: control ($37^{\circ}C$ distilled water for 24 hours ) and 3000, 6000, 12000 thermal cycling groups (n=15). Then, specimens were bonded to composite resin using a porcelain repair kit according to the manufacturer recommendation. The repair bond strength (RBS) test was performed using a universal testing machine (0.5 mm/min). Failure types were analyzed under a stereomicroscope. Two-way ANOVA and Bonferroni test were used for statistical analysis. RESULTS. The RBS values of zirconia specimens were statistically significant and higher than veneer ceramic and veneer ceramic-zirconia specimens in control, 3000 and 6000 thermal cycling groups (P<.05). When 12000 thermal cycles were applied, the highest value was found in zirconia specimens but there was no statistically significant difference between veneer ceramic and veneer ceramic-zirconia specimens (P>.05). Veneer ceramic specimens exhibited cohesive failure types, zirconia specimens exhibited adhesive failure types, and veneer ceramic-zirconia specimens exhibited predominately mixed failure types. CONCLUSION. Thermal cycling can adversely affect RBS of composite resin binded to level of fractured zirconia ceramics.

Cryogenic Thermal Cycling Test on IGRINS cross-disperser VPH Grating

  • Jeong, Hyeon-Ju;Lim, Ju-Hee;Lee, Sung-Hoo;Deen, Casey;Pak, Soo-Jong;Yuk, In-Soo;Jaffe, Daniel T.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.156-156
    • /
    • 2011
  • VPH (Volume Phase Hologram) grating is one of the transmission gratings and is known as its remarkable efficiency (>90%). It has two different densities of gelatins causing interference patterns. The VPH grating is favored in many astronomical instruments these days and also IGRINS, which is up coming near infrared high-resolution spectroscope expected to see the first light next year, uses the VPH grating as its cross-disperser. The infrared astronomical instruments operate at cryogenic temperature (~100K) in order to cut down thermal noise and the optical components of IGIRNS will be operated at 130K. The VPH grating is sandwiched in between fused silica or glass and glued together using optical adhesive. IGRINS is expected to go through 50 times of thermal cycling in 10 years including the performance test and this research is to check whether the physical characteristic such as the adhesion or dichromatic gelatin does not break and change from the several cryogenic thermal cycling. The two identical test gratings provided from Kaiser Optical System, Inc. are used in this test. One VPH grating is cooled down to 100K for 2 hours with maximum dT/dt = 5 and warmed up to the room temperature and another grating is kept stored in the room temperature and used as a control sample. In order to check the change, we inspected the grating with eyes and checked its efficiency and transmission at the room temperature every 10 cycling. From the 40 times of cryogenic temperature cool down cycling, the VPH grating showed no signs of change within the error compared to the control sample. We concluded the VPH grating is durable through several cryogenic thermal cycling.

  • PDF

A study on the shear bond strength between 3D printed resin and provisional resin after thermal cycling (3D 프린팅 레진과 임시 수복용 레진의 열순환 처리 후 전단결합강도에 관한 연구)

  • Yim, Ji-Hun;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.101-110
    • /
    • 2021
  • Purpose: In this study, we intended to study the change in bond strength according to the thermal cycling of provisional resin and 3D printed resin for making provisional restoration. Materials and Methods: Through DLP method, 3D printed resin powder was used to produce 3D printed resin samples. The samples were grouped into eight groups, according to types of provisional resin (PMMA, bis-acryl resin) which is to be bonded on the samples and numbers of thermal cycling (control, 2,000, 3,000, 5,000 cycles). Shear bond strength of the bonded samples was measured on the universal testing machine. Results: As the number of thermal cycling increased, the shear bond strength of PMMA and bis-acryl resin for 3D printed resins decreased except between 3,000 cycles and 5,000 cycles in PMMA groups. In the PMMA group, there were significant differences in shear bond strength between less number than 3,000 cycles (P < 0.05) and no significant differences between more number than 3,000 cycles (P > 0.05). In the bis-acryl resin group, there were significant differences in shear bond strength between control and 2,000 cycles, control and 3,000 cycles, and control and 5,000 cycles (P < 0.05), no significant difference between 2,000 and 3,000 cycles, between 3,000 and 5,000 cycles (P > 0.05). Conclusion: The shear bond strength between 3D printed resin and provisional resin tended to decrease after thermal cycling.

Change of phase transformation and bond strength of Y-TZP with various hydrofluoric acid etching

  • Mi-Kyung Yu;Eun-Jin Oh;Myung-Jin Lim;Kwang-Won Lee
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.54.1-54.10
    • /
    • 2021
  • Objectives: The purpose of this study was to quantify phase transformation after hydrofluoric acid (HF) etching at various concentrations on the surface of yttria-stabilized tetragonal zirconia polycrystal (Y-TZP), and to evaluate changes in bonding strength before and after thermal cycling. Materials and Methods: A group whose Y-TZP surface was treated with tribochemical silica abrasion (TS) was used as the control. Y-TZP specimens from each experimental group were etched with 5%, 10%, 20%, and 40% HF solutions at room temperature for 10 minutes. First, to quantify the phase transformation, Y-TZP specimens (n = 5) treated with TS, 5%, 10%, 20% and 40% HF solutions were subjected to X-ray diffraction. Second, to evaluate the change in bond strength before and after thermal cycling, zirconia primer and MDP-containing resin cement were sequentially applied to the Y-TZP specimen. After 5,000 thermal cycles for half of the Y-TZP specimens, shear bond strength was measured for all experimental groups (n = 10). Results: The monoclinic phase content in the 40% HF-treated group was higher than that of the 5%, 10%, and 20% HF-treated groups, but lower than that of TS-treated group (p < 0.05). The 40% HF-treated group showed significantly higher bonding strength than the TS, 5%, and 10% HF-treated groups, even after thermal cycling (p < 0.05). Conclusions: Through this experiment, the group treated with SiO2 containing air-borne abrasion on the Y-TZP surface showed higher phase transformation and higher reduction in bonding strength after thermal cycling compared to the group treated with high concentration HF.

Evaluation of the Vickers hardness on denture acrylic resins by glaze color (글레이즈 컬러를 적용한 의치상 레진의 비커스 경도 평가)

  • Yong-Woon Im
    • Journal of Technologic Dentistry
    • /
    • v.44 no.4
    • /
    • pp.111-117
    • /
    • 2022
  • Purpose: This study was conducted to compare the Vickers hardness on the denture acrylic resins using the glaze color system. Methods: The specimens (20×2 mm) were prepared by mixing according to the manufacturer's protocols through thermal polymerization and self-polymerization. The surface roughness was measured using a testing machine after water-soaking for 48 hours. For the Vickers hardness measurement, the completed specimen was soaked in water for 48 hours and then applied at 200 gf for 30 seconds. Was the specimen immersed after being soaked in water for 48 hours at temperatures of 5℃ and 55℃, respectively, for 30 seconds for the thermos-cycling treatment, and it was carried out 5,000 times. Results: Surface roughness was higher in the more glazing group than in the control group. A significant difference was observed in all groups, except for the Retec Don 2000 and Luciton 199 groups (p<0.05). As a result of measuring the Vickers hardness, the treatment by glaze color showed slightly lower but the thermo-cycling treatment group appeared higher than control group in all. Conclusion: Therefore, the glaze color was found to affect the surface roughness and showed a significant difference. The surface glaze color showed a very high Vickers hardness after the thermo-cycling treatment, indicating that the surface-strengthening effect is greater in the oral environment.

The effect of tooth brushing and thermal cycling on a luster change of ceromers finished with different methods

  • Cho, Lee-Ra;Yi, Yang-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.3
    • /
    • pp.336-347
    • /
    • 2000
  • Statement of problem. Luster loss in esthetic anterior ceromer restoration can occur and can be related with rough surface texture. Understanding durability of surface finishing methods like polishing and surface coating have critical importance. Purpose. This study evaluated the effect of tooth brushing and thermal cycling on surface luster of 3 ceromer systems (Artglass, Targis, Sculpture) treated with different surface finishing methods. Material and methods. Seventy-two samples were prepared: 12 for control group Z100, 12 for Artglass, 24 for Targis, and 24 for Sculpture. Half of the Targis and Sculpture were polished according to the manufacturer's recommendation. The rest of the samples were coated with staining and glazing solution for Targis and Sculpture, respectively. All specimens were subjected to 10,000 cycles between $5^{\circ}C\;and\;55^{\circ}C$ with 30 seconds dwell time. Tooth brushing abrasion tests were performed in a customized tooth brushing machine with 500g back and forth for 20,000 cycle. Luster comparisons were based on grading after direct observation, and light reflection area was measured with Image analysis software. Results. All materials showed an decrease in luster grade after thermal cycling and tooth brushing. The post-tooth brushing results revealed that the glazed Sculpture had greater mean luster grade than did any other groups. While, the stained Targis group showed greatest changes after tooth brushing (p < 0.05), polished Targis and Sculpture did not show significant changes. However, glazed Sculpture showed discretely fallen out glaze resin. Conclusion. From the results of this study, all of the ceromer specimens were much glossy than control composite group after tooth brushing. coatings used for Targis and Sculpture had not durability for long term use.

  • PDF

Development and Performance Validation of Thermal Control Subsystem for Earth Observation Small Satellite Flight Model (지구관측 소형위성 비행모델의 열제어계 개발 및 성능 검증)

  • Chang, Jin-Soo;Jeong, Yun-Hwang;Kim, Byung-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.12
    • /
    • pp.1222-1228
    • /
    • 2008
  • A small satellite, DubaiSat-1 FM(Flight Model), which is based on SI-200 standard bus platform and scheduled to be launched in 2008, is being developed by Satrec Initiative and EIAST(Emirates Institution for Advanced Science and Technology). The TCS(Thermal Control Subsystem) of DubaiSat-1 FM has been designed to mainly utilize passive thermal control in order to minimize power consumption, but the active control method using heaters has been applied to some critical parts. Also, thermal analysis has been performed for DubaiSat-1's mission orbit using a thermal analysis model. The thermal design is modified and optimized to satisfy the design temperature requirements for all parts according to the analysis result. The thermal control performance of DubaiSat-1 FM is verified by thermal vacuum space simulation, consisting of thermal cycling and thermal balance test. Also, to validate the thermal modeling of DubaiSat-1 FM, comparison of test results with analysis has been performed and model calibration has been completed.

Poly(Imide) Separator Functionalized by Melamine Phosphonic Acid for Regulating Structural and Thermal Stabilities of Lithiumion Batteries

  • Ye Jin Jeon;Juhwi Park;Taeeun Yim
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.365-372
    • /
    • 2024
  • As the energy density of lithium-ion batteries (LIBs) continues to increase, various separators are being developed to with the aim of improving the safety performance. Although poly(imide) (PI)-based separators are widely used, it is difficult to control their pore size and distribution, and this may further increase the risk associated. Herein, a melamine phosphonic acid (MP)-coated PI separator that can effectively control the pore structure of the substrate is suggested as a remedy. After the MP material is embedded into the PI separator with a simple one-step casting process, it effectively clogs the large pores of the PI separator, preventing the occurrence of internal short circuits during charging. It is anticipated that the MP material can also suppress rapid thermal runaway upon cycling due to its ability to reduce the internal temperature of the LIB cell caused by the desirable endothermic behavior around 300℃. According to experiments, the MP-coated PI separator not only decreases the thermal shrinkage rate better than commercial poly(ethylene) (PE) separators but also exhibits a desirable Gurley number (109.6 s/100 cc) and electrolyte uptake rate (240%), which is unique. The proposed separator is electrochemically stable in the range 0.0-5.0 V (vs. Li/Li+), which is the typical working potential of conventional electrode materials. In practice, the MP-coated PI separator exhibits stable cycling performance in a graphite-LiNi0.83Co0.10Mn0.07O2 full cell without an internal short circuit (retention: 90.3%).