• Title/Summary/Keyword: thermal conditions

Search Result 4,621, Processing Time 0.031 seconds

CORE THERMAL HYDRAULIC BEHAVIOR DURING THE REFLOOD PHASE OF COLD-LEG LBLOCA EXPERIMENTS USING THE ATLAS TEST FACILITY

  • Cho, Seok;Park, Hyun-Sik;Choi, Ki-Yong;Kang, Kyoung-Ho;Baek, Won-Pil;Kim, Yeon-Sik
    • Nuclear Engineering and Technology
    • /
    • v.41 no.10
    • /
    • pp.1263-1274
    • /
    • 2009
  • Several experimental tests to simulate a reflood phase of a cold-leg LBLOCA of the APR1400 have been performed using the ATLAS facility. This paper describes the related experimental results with respect to the thermal-hydraulic behavior in the core and the system-core interactions during the reflood phase of the cold-leg LBLOCA conditions. The present descriptions will be focused on the LB-CL-09, LB-CL-11, LB-CL-14, and LB-CL-15 tests performed using the ATLAS. The LB-CL-09 is an integral effect test with conservative boundary condition; the LB-CL-11 and -14 are integral effect tests with realistic boundary conditions, and the LB-CL-15 is a separated effect test. The objectives of these tests are to investigate the thermal-hydraulic behavior during an entire reflood phase and to provide reliable experimental data for validating the LBLOCA analysis methodology for the APR1400. The initial and boundary conditions were obtained by applying scaling ratios to the MARS simulation results for the LBLOCA scenario of the APR1400. The ECC water flow rate from the safety injection tanks and the decay heat were simulated from the start of the reflood phase. The simulated core power was controlled to be 1.2 times that of the ANS-73 decay heat curve for LB-CL-09 and 1.02 times that of the ANS-79 decay curve for LB-CL-11, -14, and -15. The simulated ECC water flow rate from the high pressure safety injection pump was 0.32 kg/s. The present experimental data showed that the cladding temperature behavior is closely related to the collapsed water level in the core and the downcomer.

On the thermal buckling response of FG Beams using a logarithmic HSDT and Ritz method

  • Kadda Bouhadjeb;Abdelhakim Kaci;Fouad Bourada;Abdelmoumen Anis Bousahla;Abdelouahed Tounsi;Mohammed A. Al-Osta;S.R. Mahmoud;Farouk Yahia Addou
    • Geomechanics and Engineering
    • /
    • v.37 no.5
    • /
    • pp.453-465
    • /
    • 2024
  • This paper presents a logarithmic shear deformation theory to study the thermal buckling response of power-law FG one-dimensional structures in thermal conditions with different boundary conditions. It is assumed that the functionally graded material and thermal properties are supposed to vary smoothly according to a contentious function across the vertical direction of the beams. A P-FG type function is employed to describe the volume fraction of material and thermal properties of the graded (1D) beam. The Ritz model is employed to solve the thermal buckling problems in immovable boundary conditions. The outcomes of the stability analysis of FG beams with temperature-dependent and independent properties are presented. The effects of the thermal loading are considered with three forms of rising: nonlinear, linear and uniform. Numerical results are obtained employing the present logarithmic theory and are verified by comparisons with the other models to check the accuracy of the developed theory. A parametric study was conducted to investigate the effects of various parameters on the critical thermal stability of P-FG beams. These parameters included support type, temperature fields, material distributions, side-to-thickness ratios, and temperature dependency.

Estimation of C(t) -Integral Under Transient Creep Conditions for a Cracked Pipe Subjected to Combined Mechanical and Thermal Loads Depending on Loading Conditions (열응력 및 기계응력이 작용하는 균열배관의 하중조건에 따른 천이 크리프 조건 C(t)-적분 평가)

  • Oh, Chang-Young;Song, Tae-Kwang;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.6
    • /
    • pp.609-617
    • /
    • 2011
  • There is a trend towards the progressive use of higher operating temperatures and stresses to achieve improved efficiencies in power-generation equipment. It is important to perform the crack assessment under hightemperature and high-pressure conditions. The C(t)-integral is a key parameter in crack assessment for transient creep states. The estimation of the C(t)-integral is complex when considering the mechanical and thermal loads simultaneously. In this paper, we study estimation of C(t)-integral under combined mechanical and thermal load depending on loading conditions.

Development of Numerical Analysis Technique of Thermal Flows for Experiment of Combined Weapon Systems (복합무기체계 실험을 위한 열유동 수치해석 기법 개발)

  • Kim, Sung-Dae;Tyoo, Seong-Tyoul;Baek, Sang-Hwa;Lee, Jeong-Yong;Park, So-Jin;Kim, Chul-Ju;Ko, Han-Seo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.397-400
    • /
    • 2008
  • A numerical analysis has been performed in this study to predict thermal behaviors of combined weapon systems in a large environmental tester. Also, temperature distributions of the materials of the system have been measured for the experimental conditions. The calculated thermal flow characteristics and the measured temperature distributions of the materials for the weapon systems have been analyzed to prepare for field tests in the environmental tester. The boundary conditions of the analysis are composed of inlet and outlet conditions of the environmental tester with various pressures and the limit of low temperature of -25$^{\circ}$C. The soaking time of the system in the environmental tester has been obtained by developed programs in this study to carry out the experiment in the predicted conditions.

  • PDF

Thermal buckling response of functionally graded sandwich plates with clamped boundary conditions

  • Abdelhak, Zohra;Hadji, Lazreg;Daouadji, T. Hassaine;Adda Bedia, E.A.
    • Smart Structures and Systems
    • /
    • v.18 no.2
    • /
    • pp.267-291
    • /
    • 2016
  • In this research work, an exact analytical solution for thermal buckling analysis of functionally graded material (FGM) sandwich plates with clamped boundary condition subjected to uniform, linear, and non-linear temperature rises across the thickness direction is developed. Unlike any other theory, the number of unknown functions involved is only four, as against five in case of other shear deformation theories. The theory accounts for parabolic distribution of the transverse shear strains, and satisfies the zero traction boundary conditions on the surfaces of the plate without using shear correction factor. A power law distribution is used to describe the variation of volume fraction of material compositions. Equilibrium and stability equations are derived based on the present refined theory. The non-linear governing equations are solved for plates subjected to simply supported and clamped boundary conditions. The thermal loads are assumed to be uniform, linear and non-linear distribution through-the-thickness. The effects of aspect and thickness ratios, gradient index, on the critical buckling are all discussed.

Evaluation of Thermal Comfort during Sleeping in Summer - Part III : About Indoor Air Temperatures Rise - (여름철 수면시 온열쾌적감 평가 - 제3보 : 실내온도 상승에 관하여 -)

  • Kim Dong-Gyu;Kum Jong-Soo;Kim Se-Hwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.535-540
    • /
    • 2006
  • This study was performed In evaluate sleep efficiencies and conditions for comfortable sleep based on the analysis of Physiological signals under variations in thermal conditions. Five female subjects who have similar life cycle and sleep patterns were participated for the sleep experiment. It was checked whether they had a good sleep before the night of experiment. EEGs were obtained from C3-A2 and C4-A1 electrode sites and EOGs were acquired from LOC (left outer canthus) and ROC (right outer canthus) for REM sleep detection. Sleep stages were classified, then TST (total sleep time), SWS (slow wave sleep) latency and SWS/TST were calculated for the evaluation of sleep efficiencies on thermal conditions. TST was defined as an amount of time from sleep stage 1 to wakeup. SWS latency was from light off time to sleep stage 3 and percentage of SWS over TST was calculated for the evaluation of sleep quality and comfort sleep under thermal conditions. As result, the condition which raise a room temperature provided comfortable sleep.

Lead bromide crystal growth from the melt and characterization: the effects of nonlinear thermal boundary conditions on convection during physical vapor crystal growth of mercurous bromide

  • Geug-Tae Kim;Moo Hyun Kwon
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.14 no.4
    • /
    • pp.160-168
    • /
    • 2004
  • We investigate the effects of solutal convection on the crystal growth rate in a horizontal configuration for diffusive-convection conditions and purely diffusion conditions achievable in a low gravity environment for a nonlinear thermal gradient. It is concluded that the solutally-driven convection due to the disparity in the molecular weights of the component A $(Hg_2Br_2)$ and B (CO) is stronger than thermally-driven convection for both the nonlinear and the linear thermal profiles, corresponding to $Gr_t= 8.5{\times}10^3,\; Gr_s = 1.05{\times}10^5$. For both solutal and thermal convection processes, the growth rates for the linear thermal profile (conducting walls) are greater than for the nonlinear case. With the temperature humps, there are found to be observed in undersaturation for diffusive-convection processes ranging from $D_{AB}$ = 0.087 to 0.87. For the vertical configurations, the diffusion mode is so much dominated that the growth rate and interfacial distribution is nearly regardless of the gravitational accelerations. Also, the diffusion mode is predominant over the convection for the gravity levels less than 0.1 $g_0$ for the horizontally oriented configuration.

Heat Characteristics Analysis of Radiator for PCB-Board (PCB-BOARD의 방열기 발열특성 해석)

  • Jang, Sung-Cheol;Kweon, Min-Su;Han, Soo-Min
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.20-26
    • /
    • 2016
  • For power electronic devices, the thermal energy density per unit volume has seen a rapid increase in recent years, owing to the miniaturization and dense integration of electronic components, as well as the continuous development in performance and function. This research examined the validity and reliability of a thermal safety model for managing the heating conditions of TRIAC electronic components. Among the electronic components of a PCB, these can be considered as a heat source. Using the model, the heating conditions of TRIAC components were maintained at their design target levels in the process of developing an LMT motor drive board. In addition, the heating characteristics of the entire PCB were analyzed to verify its thermal safety. Finally, the reliability and validity of the thermal safety model for maintaining the heating conditions of the TRIAC electronic elements at adequate levels was verified using a numerical analysis method.

A Study on the Temperature Reduction Effect of Street Green Area (도로변 가로녹지 유형이 기상에 미치는 영향)

  • Kim, Jeong-Ho;Choi, Won-Jun;Yoon, Yong-Han
    • Journal of Environmental Science International
    • /
    • v.26 no.12
    • /
    • pp.1363-1374
    • /
    • 2017
  • Global climate change caused by industrialization has caused abnormal weather conditions such as urban temperatures and tropical nights, urban heat waves, heat waves, and heavy rains. Therefore, the study tried to analyze climate conditions and weather conditions in the streets and analyze climate factors and meteorological factors that lead to inconvenience to citizens. In the case of trees, the overall temperature, surface temperature, solar irradiance, and net radiation were measured low, and the temperature was lower in the Pedestrian road than in roads. The dry bulb temperature, the black bulb temperature, and the wet bulb temperature for the thermal evaluation showed the same tendency. In the case of thermal evaluation, there was a similar tendency to temperature in WBGT, MRT, and UTCI, and varied differences between types. Although the correlation between the meteorological environment and the thermal environment showed a statistically significant significance, the difference between the measured items was not significant. The study found that the trees were generally pleasant to weather and thermal climate in the form of trees, and the differences were mostly documented.

Thermal-hydraulic 0D/3D coupling in OpenFOAM: Validation and application in nuclear installations

  • Santiago F. Corzo ;Dario M. Godino ;Alirio J. Sarache Pina;Norberto M. Nigro ;Damian E. Ramajo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.5
    • /
    • pp.1911-1923
    • /
    • 2023
  • The nuclear safety assessment involving large transient simulations is forcing the community to develop methods for coupling thermal-hydraulics and neutronic codes and three-dimensional (3D) Computational Fluid Dynamics (CFD) codes. In this paper a set of dynamic boundary conditions are implemented in OpenFOAM in order to apply zero-dimensional (0D) approaches coupling with 3D thermal-hydraulic simulation in a single framework. This boundary conditions are applied to model pipelines, tanks, pumps, and heat exchangers. On a first stage, four tests are perform in order to assess the implementations. The results are compared with experimental data, full 3D CFD, and system code simulations, finding a general good agreement. The semi-implicit implementation nature of these boundary conditions has shown robustness and accuracy for large time steps. Finally, an application case, consisting of a simplified open pool with a cooling external circuit is solved to remark the capability of the tool to simulate thermal hydraulic systems commonly found in nuclear installations.