• Title/Summary/Keyword: thermal conditions

Search Result 4,621, Processing Time 0.031 seconds

Thermal Comfort Condition of Temperature and Humidity in Loess Interior Space

  • Kong, Sung-Hoon
    • Biomedical Science Letters
    • /
    • v.10 no.2
    • /
    • pp.129-135
    • /
    • 2004
  • The study was carried out through measuring the temperature and humidity of the indoor/outdoor space and the distribution of interior thermal condition, and investigating the effect of loess materials on human body. The purpose of this study is to analyze the change of dry bulb temperature and relative humidity and correlation of thermal reaction of human body with ASHRAE (American Society of Heating, Refrigerating and Air-conditioning) comfort chart in the loess interior space. In the view point of biomedical sciences, loess interior space provides optimum thermal conditions for human thermal sensation.

  • PDF

Experiments on Thermal Conductivity of Concrete (콘크리트의 열전도율에 관한 실험적 연구)

  • 김진근;전상은;양은익;김국한;조명석;방기성
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.946-951
    • /
    • 1998
  • In order to calculate the thermal stresses of massive concrete structures in non-steady state conditions the thermal properties of the materials have to be well known. Structural materials such as concrete, rock and soil are heterogeneous, damp and porous so that measurements of their thermal properties by conventional methods would result in large errors. In this study, thermal conductivity was measured by the device, QTM-D3 which is usually used in Japan. Variables are chosen as age, water content, temperature, aggregate content, S/A ratio and type of cementitious materials. Finally a model for thermal conductivity was proposed.

  • PDF

Effects of Thermal Pretreatment Temperature on the Solubilization Characteristics of Dairy Manure for Dry Anaerobic Digestion

  • Ahn, Heekwon;Lee, Seunghun;Kim, Eunjong;Lee, Jaehee;Sung, Yongjoo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.2
    • /
    • pp.127-132
    • /
    • 2014
  • The effect of thermal pretreatment conditions on hydrolysis characteristics of dairy manure and sawdust mixtures has been evaluated. Thermal pretreatment temperature varied between 35 and $120^{\circ}C$ and the period of the treatment changed between 30 and 1440min (24h). As thermal pretreatment temperature and duration increased, organic material solublization rates were improved. Maximum solubilizations of chemical oxygen demand (SCOD), carbohydrates, and volatile fatty acids(VFAs) were observed when dairy manure treated for one day at $120^{\circ}C$. Although one day treatment duration at $120^{\circ}C$ showed the highest SCOD, soluble carbohydrates, and VFAs concentration, its hydrolysis rate was only about 12%. The results reveal that the thermal pretreatment conditions tried in this study are not enough to solubilize the organic matter contained in dairy manure and sawdust mixtures. In order to maximize hydrolysis performance, the further research needs to determine the factors influences on organic material solubilization in addition to thermal pretreatment temperature and duration.

Human Solar Heat Load and Thermal Comfort in an Outdoor Environment (건축외부공간에 있어서 인체의 일사열부하(日射熱負荷) 및 열적(熱的) 쾌적성(快適性)에 관한 실험적 연구)

  • Jeong, Chang-Won;Yoon, In
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.1 no.2
    • /
    • pp.65-74
    • /
    • 1998
  • The purpose of this paper is to investigate the mount of relief of human solar heat load and thermal comfort in outdoor environment in summer, Six different types of sites, T garden and its neighboring area in Japan, were selected as the experiment sites. The experiments were conducted from 22 to 29 August, 1994 to find the relationship between climatic conditions and human responses, Climatic conditions, subjects's thermal sensation and skin temperature were measured. Radiant heat exchange on the human body was estimated on the basis of the measured air and surface temperature and solar radiation. Thermal index Operative Temperature and New Effective Temperature was modified with the effect of the radiant heat exchange. Human thermal comfort and skin temperature is affected by the solar radiation and the sky factor in an outdoor environment. The effect of tree shade was verified on thermal comfort, The mount of relief of human solar heat load is relation to the existence of shade a solar radiation and the sky factor. The urban garden is one of the effective design element in an urban environmental planning.

  • PDF

Electrical Property Evaluation of Printed Copper Nano-Ink Annealed with Infrared-Lamp Rapid Thermal Process (적외선 램프를 이용하여 소결한 구리 나노잉크의 전기적 특성 평가에 관한 연구)

  • Han, Hyun-Suk;Kim, Changkyu;Yang, Seung-Jin;Kim, Yoon-Hyun
    • Korean Journal of Materials Research
    • /
    • v.26 no.4
    • /
    • pp.216-221
    • /
    • 2016
  • A sintering process for copper based films using a rapid thermal process with infrared lamps is proposed to improve the electrical properties. Compared with films produced by conventional thermal sintering, the microstructure of the copper based films contained fewer internal and interfacial pores and larger grains after the rapid thermal process. This high-density microstructure is due to the high heating rate, which causes the abrupt decomposition of the organic shell at higher temperatures than is the case for the low heating rate; the high heating rate also induces densification of the copper based films. In order to confirm the effect of the rapid thermal process on copper nanoink, copper based films were prepared under varying of conditions such as the sintering temperature, time, and heating rate. As a result, the resistivity of the copper based films showed no significant changes at high temperature ($300^{\circ}C$) according to the sintering conditions. On the other hand, at low temperatures, the resistivity of the copper based films depended on the heating rate of the rapid thermal process.

Numerical Study on the Thermal Entrance Effect in Miniature Thermal Conductivity Detectors (소형 Thermal Conductivity Detector의 입구열전달 거동에 대한 수치해석)

  • Kim, U-Seung;Kim, Yeong-Min;Chen, Kuan;Cheon, Won-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.439-447
    • /
    • 2002
  • The microchannel flow in miniature TCDs (thermal conductivity detectors) is investigated numerically. The solutions based on the boundary layer approximation are not very accurate in the region of the duct inlet for low Reynolds numbers. In this study, two-dimensional Navier-Stokes equations are considered to analyze the gas flow in a miniature TCD. Effects of channel size, inlet and boundary conditions on the heat transfer rate are examined. When the gas stream is not preheated, the distances for a miniature TCD to reach the conduction-dominant region for duct flow are found to be approximately two and three times the thermal entry length for duct flow with constant properties, respectively, leer constant wall temperature and constant wall heat flux boundary conditions. If the gas temperature at the channel inlet is close to the mean gas temperature in the conduction-dominant region, the entrance region is much shorter compared to other cases considered in this study.

Thermal Instability and Heat Transfer Correlations of Laminar Flow over Isothermal Horizontal Flat Plate (등온 수평 평판 위를 지나는 층류유동 의 열적 불안전성 및 열전달 상관관계)

  • 박병완;유정열;최창균;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.5
    • /
    • pp.613-620
    • /
    • 1985
  • An analysis on the thermal instability of horizontal Blasius flow in the form of longitudinal vortices has been carried out by introducing the 3-dimensional spatial dependence of the disturbance quantities. The stability problem has been simplified significantly by considering the limiting case of infinite Prandtl number and by skilfully replacing the boundary conditions at infinity with the interface conditions at the edge of the thermal boundary layer (or by simply confining the thermal disturbances in the thermal boundary layer). The advantage of this approach is that the critical values marking the onset of thermal instability can be readily obtained as solutions of the eigenvalues problems formulated by a 6*6(or a 5*5) determinant. Present analysis provides reasonable explanations on the existing experimental and theoretical data. Especially, the heat transfer correlation based on the present analysis agrees well with the existing experimental data.

Studies on the Thermal Resistant Spore of Bacillus coagulance(Part I Sporulating Conditions of the Thermal Resistant spore) (Bacillus coagulance 의 내열성포자에 관한 연구 (제일보) 생육ㆍ내열성및 포자형성에 미치는 단양조건)

  • 유주현;최규봉;이정치;윤원영
    • Microbiology and Biotechnology Letters
    • /
    • v.5 no.1
    • /
    • pp.5-12
    • /
    • 1977
  • As a basic study for the application of the spore-tearing lactic acid bacteria to foods, the effects of the sporulating conditions on the growth and sporogenesis were studied were observed. The results obtained are as follow. 1. All carbohydrates added to sporulation media except dextrin decreased the sporulation rate and the thermal resistance of spores. Dextrin stimulated the growth, however, there in no effect on the thermal resistance. 2. As nitrogen source, the protein hydrolysates such as peptone, casamino acid were effective to obtain were spores of the increased thermal resistance. 3. Ca$\^$++/, Mn$\^$++/ of the metal ions added to casamino acid containing medium validly increased the total growth, sporulation rate and thermal resistance. Its optimum concentration was 40 ppm each. 4. Biotin of vitamines had an effect on the total growth, sporulation and thermal resistance of spores. Its optimum concentration was 30${\gamma}$/ml. 5. The resistant spores required the adequate maturation period, more than 36 hours, sufficient aeration. and optimum temperature, 37∼45$^{\circ}C$.

  • PDF

Partial Discharge Diagnosis of Thermal Degradated PVC Cable (열열화된 PVC 케이블의 부분방전 진단)

  • Song, Ki-Tae;Lee, Sung-Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.3
    • /
    • pp.208-214
    • /
    • 2011
  • In this thesis, the partial discharge according to applied voltage and variations of cross-sectional area and length of the conductor related to general condition for using cable was measured in order to study degradation diagnosis for 2-Core cable of the PVC insulator used in industrial fields for other safety installations. Also the thermal degradation conditions under various installation circumstances of cables were studied by assuming degradation conditions with each different degradation rate (50%, 67%, 100%) such as variation in degradated temperature, thermal exposure time, normal state, partially degradated state and overall degradated state for thermal degradation diagnosis. The quantity of electric discharge (V-Q) according to applied voltage was measured for measurement of inception voltage and extinction voltage. The quantity of electric discharge and the number of electric discharge (Q-N) were measured with applied voltage kept constantly. In addition, pictures were taken using SEM (scanning electron microscope) to compare the surface of external insulator to degradated state of internal insulator according to thermal degradation temperature and also compare the surface of external insulator to degradated surface state of internal insulator according exposure time of cables to thermal stress.

Characteristics of Black Ice Using Thermal Imaging Camera (열화상카메라를 이용한 블랙아이스 특성 연구)

  • Kim, Seung-Jun;Yoon, Won-Sub;Kim, Yeon-Kyu
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.6_2
    • /
    • pp.873-882
    • /
    • 2021
  • In this study, a study was conducted to develop a system for predicting/responding to black ice occurring on roads in winter. Tests conditions were studied by making models of cement concrete pavement and asphalt concrete pavement. In order to freeze water on the manufactured model package, an tests was conducted at a temperature below zero using a freezer, and the freezing process was photographed using a thermal imaging camera. Black ice is generated when water is present on the road surface and the temperature is below freezing or the road surface temperature is below the dew point temperature. Under sub-zero conditions, the pavement, water, and ice were classified with a thermal imaging camera. As a result of the tests, it was possible to distinguish with a thermal imaging camera at a temperature below freezing in the same freezer due to the difference in the emissivity of the packaging, water, and ice. In the process of changing from water to ice during the tests, it was analyzed that ice and water were clearly distinguished by the thermal imaging camera due to the difference in emissivity and reflectance, so black ice could be predicted using the thermal imaging camera.