• 제목/요약/키워드: thermal bridge

검색결과 297건 처리시간 0.022초

Anorthite의 합성 및 그 특성에 관한 연구 (A Study on the Synthesis of Anorthite and its Characteristics.)

  • 백용혁;이종권
    • 한국세라믹학회지
    • /
    • 제20권2호
    • /
    • pp.153-160
    • /
    • 1983
  • This study was carried out to research the change of mineral phases and the characteristics(apparent specific gra-vity water absorption firing shrinkage modulus of rupture thermal expansion and specific dielectric constant) of the sintered bodies manufactured by kaolin and limestone. Samples were composed of the same theoretical composition as it of anorthite and fired up to 145$0^{\circ}C$ Investigated the change and micro-structure of the mineral phases by XRD and SEM the characterisdtics of the sintered bodies by TMA Automatic Capacitance Bridge and etc. The results were as follow. 1. Reactions of sintering are occurred between 860-95$0^{\circ}C$ and 1200-138$0^{\circ}C$ and state of bloating is occurred at 1410-145$0^{\circ}C$ 2. For the inclusion of feldspar and its fine particles of materials the temperature of producing and collapsing is decreased. 3. Pseudo-wollastonite and gehlenite are formed about 95$0^{\circ}C$ 4. At 114$0^{\circ}C$ anorthite are begin to forming and increase continuously to 138$0^{\circ}C$. Above 141$0^{\circ}C$ content of anorthite are decreased. 5. The variations of bending strength with sintering temperature reflect similar trend of sintered contraction and in-crease continuously from 120$0^{\circ}C$. At 145$0^{\circ}C$ reached about 680kg/cm2. 6. Specific dielectric constant$($\varepsilon$_s)$ of specimen sintered at 141$0^{\circ}C$ is 7.12 and that value is most favorable.

  • PDF

Single-Phase Bridgeless Zeta PFC Converter with Reduced Conduction Losses

  • Khan, Shakil Ahamed;Rahim, Nasrudin Abd.;Bakar, Ab Halim Abu;Kwang, Tan Chia
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.356-365
    • /
    • 2015
  • This paper presents a new single phase front-end ac-dc bridgeless power factor correction (PFC) rectifier topology. The proposed converter achieves a high efficiency over a wide range of input and output voltages, a high power factor, low line current harmonics and both step up and step down voltage conversions. This topology is based on a non-inverting buck-boost (Zeta) converter. In this approach, the input diode bridge is removed and a maximum of one diode conducts in a complete switching period. This reduces the conduction losses and the thermal stresses on the switches when compare to existing PFC topologies. Inherent power factor correction is achieved by operating the converter in the discontinuous conduction mode (DCM) which leads to a simplified control circuit. The characteristics of the proposed design, principles of operation, steady state operation analysis, and control structure are described in this paper. An experimental prototype has been built to demonstrate the feasibility of the new converter. Simulation and experimental results are provided to verify the improved power quality at the AC mains and the lower conduction losses of the converter.

Structural damage detection in presence of temperature variability using 2D CNN integrated with EMD

  • Sharma, Smriti;Sen, Subhamoy
    • Structural Monitoring and Maintenance
    • /
    • 제8권4호
    • /
    • pp.379-402
    • /
    • 2021
  • Traditional approaches for structural health monitoring (SHM) seldom take ambient uncertainty (temperature, humidity, ambient vibration) into consideration, while their impacts on structural responses are substantial, leading to a possibility of raising false alarms. A few predictors model-based approaches deal with these uncertainties through complex numerical models running online, rendering the SHM approach to be compute-intensive, slow, and sometimes not practical. Also, with model-based approaches, the imperative need for a precise understanding of the structure often poses a problem for not so well understood complex systems. The present study employs a data-based approach coupled with Empirical mode decomposition (EMD) to correlate recorded response time histories under varying temperature conditions to corresponding damage scenarios. EMD decomposes the response signal into a finite set of intrinsic mode functions (IMFs). A two-dimensional Convolutional Neural Network (2DCNN) is further trained to associate these IMFs to the respective damage cases. The use of IMFs in place of raw signals helps to reduce the impact of sensor noise while preserving the essential spatio-temporal information less-sensitive to thermal effects and thereby stands as a better damage-sensitive feature than the raw signal itself. The proposed algorithm is numerically tested on a single span bridge under varying temperature conditions for different damage severities. The dynamic strain is recorded as the response since they are frame-invariant and cheaper to install. The proposed algorithm has been observed to be damage sensitive as well as sufficiently robust against measurement noise.

건축물에너지 효율을 위한 조적조 열교 차단 브라켓의 성능 평가 연구 (A Study on Performance Evaluation of Masonry Thermal Bridge Blocking Brackets for Building Energy Efficiency)

  • 김웅회;김형규;이태규;이재현;김규용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.175-176
    • /
    • 2023
  • The masonry structure is constructed by cement mortar binding material of brick objects and uses reinforced hardware(connected hardware or wall tie) together when building. However, over time, the corrosion of reinforced steel and the deterioration of joint mortar as well as bricks cause the risk of collapse. In particular, when the externally decorated brick wall is installed on the concrete girder for each floor, the angle bracket is not constructed or corroded, the full-layer weight load is applied to the wall of 0.5B, which is an example of full-scale or collapse. As a result of the evaluation, it was confirmed that the performance was improved compared to the existing bracket, and we plan to carry out a real-life test and long-term performance review of the building using the bracket in the future.

  • PDF

창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구 (A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window)

  • 이장범
    • 대한건축학회논문집:계획계
    • /
    • 제35권11호
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.

Chromophore 형성과 rhodopsin kinase 활성을 이용한 항활성 로돕신 mutant의 분석 (Chromophore formation and phosphorylation analysis of constitutively active rhodopsin mutants)

  • 김종명
    • 생명과학회지
    • /
    • 제17권6호통권86호
    • /
    • pp.783-790
    • /
    • 2007
  • G protein-coupled receptor, (GPCR)는 세포외부의 신호를 인식 시 G 단백질을 활성화시켜 신호를 전달하며 kinase에 의한 인산화를 통하여 지속적인 신호전달을 억제한다. 외부 신호물질이 없는 조건에서도 활성을 나타내는 항활성 돌연변이종(CAM)은 GPCR의 신호전달 이상에 기인한 질병 치료나 활성화 구조변화의 좋은 연구대상이다. 희미한 빛을 인식하는 시각수용체인 로돕신의 CAM으로는 salt bridge에 직접적인 영향을 미치는 돌연변이인 G90D, El13Q, 그리고 K296E와, 직접적인 영향이 없는 돌연변이인 E134q와 M25Y등 두 가지 계통의 종류가 알려져 있다. 본 연구에서는 각각의 돌연변이가 복합된 mutant를 구성하여 agonist와 inverse agonist에 대한친화도와 로돕신 kinase에 대한 활성을 조사하여 각 종에서의 구조변화의 차이를 분석하였다. 로돕신 mutant의constitutive activity는 all-trans-retinal에 대한 친화도에 비례하며 11-cis-retinal에 대한 친화도와는 역상관 관계를 보여준다. 같은 계통에 속하는 돌연변이가 합쳐진 복합 mutant는 단일 mutant에 비하여 미약한 정도의 로돕신 kinase 항활성화 증가를 보여주나, 다른 계통에 속하는 두 가지 돌연변이가 합쳐진 mutant는 항활성화가 크게 증가되었음을 보여주었다. 이 결과는 다른 계통에 속하는 mutant에서는 상이한 구조변화가 일어나며 로돕신이완전한 활성화에 이르기 위해서는 최소한 두 가지 종류의 돌연변이에 의하여 생기는 구조변화들이 함께 일어나야함을 의 미 한다. G protein 활성화와 유사한 항활성화 분석 결과는 rhodopsin kinase가 인식하는 로돕신의 활성화상태 구조가 G protein이 인식하는 구조와 유사함을 의미한다. 특히 가장 강한 활성을 나타내는 El13Q/E134Q/M257Y는 활성화상태 GPCR 단백질의 결정 시도에 이용 될 수 있을 것이다.

공포와 기쁨 정서 간 안면온도 반응의 차이 (Difference of Facial Skin Temperature Responses between Fear and Joy)

  • 음영지;엄진섭;손진훈
    • 감성과학
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2012
  • 많은 연구에서 정서 특정적 생리 반응을 밝히기 위하여 심박률, 혈류량, 피부전도 반응 등의 지표를 사용하였으나, 안면온도를 이용한 정서 연구는 많지 않다. 본 연구는 적외선 열화상을 통해 공포 및 기쁨 자극에 대한 안면온도 변화를 관찰하고자 한다. 98명의 대학생과 중고생을 대상으로 공포 또는 기쁨을 유발하는 자극을 제시하기 전과 후의 안면온도를 측정하였다. 온도값은 이마, 눈앞, 콧등, 코끝, 그리고 뺨에서 추출하였다. 공포자극을 제시한 조건에서는 콧등과 코끝의 온도가 유의하게 낮아졌다. 기쁨 자극을 제시한 조건에서는 이마, 눈앞의 온도 상승이 유의하였으며, 코끝에서 온도가 유의하게 낮아졌다. 두 조건에서 코의 온도가 유의하게 낮아졌는데, 이는 공포 또는 기쁨을 경험할 때 각성수준이 증가하여 코 혈관의 혈류량이 감소함으로써 온도가 낮아진 것으로 볼 수 있다. 공포나 기쁨을 경험할 때 나타나는 온도 변화는 정서를 경험할 때 손가락온도를 측정한 선행 연구결과와 일치한다. 이런 연구결과는 정서 측정기법의 개발과, 인간의 정서를 탐지하는 컴퓨터 시스템의 기초를 확립하는데 기여하는 바가 있을 것이다.

  • PDF

디지털 유지관리를 위한 데이터 기반 교량 신축이음 유간 평가 (Evaluation of Data-based Expansion Joint-gap for Digital Maintenance )

  • 박종호;신유성
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제28권2호
    • /
    • pp.1-8
    • /
    • 2024
  • 신축이음 장치는 교량 상부구조의 신축량을 수용할 목적으로 설치되며 공용중 충분한 유간을 확보하여야 한다. 안전점검 및 정밀안전진단 수행 시 유간부족 및 유간과다에 대한 손상을 명시하고 있으나, 유간에 따른 교량의 이상 거동을 판별하기 위한 기준이 미흡하다. 본 연구에서는 동일 신축이음부의 유간 데이터를 지속적으로 추적하여 데이터 기반의 유지관리 방안을 제시하였다. 689개소의 신축이음 장치에서 계절별 영향을 고려하여 총 2,756개의 유간 데이터를 수집하였다. 동일 위치에서 4개 이상의 데이터를 통해 신축거동을 분석할 수 있는 유간 변화 평가 방안을 마련하였으며, 신축거동에 영향을 미치는 인자를 분류하고 딥러닝과 설명 가능한 AI를 통해 각 인자의 영향도를 분석하였다. 유간 평가 그래프를 통해 교량 상부구조의 이상 거동을 협착 및 기능 고장으로 분류하였다. 이론적 거동을 보이고 있다하더라도 협착 가능성이 나타날 수 있는 사례 및 하절기 협착 가능성이 매우 높게 나타난 사례가 도출되었다. 협착 가능성은 낮으나 교량 상부구조에 기능상 문제점이 발생했을 가능성이 높은 사례와 시공오류에 따라 신축이음 장치가 재시공된 사례도 도출되었다. 딥러닝 및 설명 가능한 AI를 통한 영향인자 분석은 기존의 신축유간 계산식 및 교량 설계에 따른 결과로 설명 가능하여 신뢰 가능한 수준으로 판단되어 추후 모델의 개선을 통해 유지관리를 위한 가이드를 제시할 수 있을 것이라 판단된다.

금속용사와 도장의 복합피복방식법에 대한 실험적 내후성능평가 (Experimental Evaluation of Weathering Performance for Duplex Coating Systems Combining Thermal Spraying Metals and Painting)

  • 김인태;전제형;차기혁;정영수;안진희
    • 한국강구조학회 논문집
    • /
    • 제28권5호
    • /
    • pp.373-382
    • /
    • 2016
  • 도장 또는 금속용사는 강구조물의 방식에 널리 사용되고 있으며, 금속용사와 도장의 복합방식법은 혹독한 부식환경하에 놓인 강구조물에 고내후성 피복방식법으로 적용되고 있다. 본 연구에서는 아연(Zn), 아연-알루미늄(ZnAl)합금, 알루미늄(Al), 알루미늄-마그네슘(AlMg)합금의 4종류 금속용사 후 실링 처리한 시편, 4종류 금속용사 후 중방식 도장한 시편과 도장만 실시한 시편을 대상으로 175일간의 ISO 20340 부식촉진실험을 실시하여, 각 방식법의 상대적인 내후성능을 비교, 검토하였다. 강재표면까지 도달하는 원형 및 선형 초기결함으로부터의 표면상태 변화 및 도막의 노화면적에 근거한 내후성능의 평가 결과, 금속용사 후 실링 처리한 시편의 경우에는 알루미늄(Al) 및 알루미늄-마그네슘(AlMg)금속용사 후 실링 처리한 시편이 가장 우수한 내후성능을 보였으며, 금속용사 후 도장을 실시한 금속용사와 도장의 복합방식법의 경우에는 아연(Zn)용사에 도장을 실시한 복합방식 시편이 가장 우수한 내후성능을 나타내었다.

그린하우스의 프라스틱 피복재를 통한 상대적 열손실 속도를 측정하는 간단한 장치 (A simple device to measure the relative rate of heat loss through plastic coverings from greenhouse)

  • 정진;박병빈
    • 한국환경농학회지
    • /
    • 제8권2호
    • /
    • pp.142-147
    • /
    • 1989
  • 환기에 의한 열손실과 지중으로의 열손실을 제외하면 그린하우스의 열손실은 피복재를 통한 열전도 및 열복사에 의해 일어난다. 따라서 동일한 환경조건 하에서 프라스틱 필름으로 하우스를 만들 때 하우스의 보온력은 피복재를 통한 열손실 속도의 크기에 지배받는다. 본 연구에서는 프라스틱 필름을 통한 상대적 열손실 속도를 측정함으로써 하우스의 보온력을 예측할 수 있는 간단한 장치와 방법을 고안하였다. 육면체 형태의 frame을 만들어 측정용 필름으로 둘러싸서 밀폐된 box를 만들고 thermostat로 조절되는 heater와 box 내부의 온도변화를 감지 기록하기 위한 온도 Probe를 내부에 장치하였다. box 내부와 외부간에 일정한 온도차를 이루게 한 다음 (10$^{\circ}C$내외), 그 온도 차이가 유지되도록 일정한 양의 열을 10회에 걸쳐 단속적으로 (그리고 자동적으로) 투입함에 있어서 그 투입 에 요한 총 시간, 즉 항온유지시간을 재고, 이 항온유지 시간의 역수로서 필름을 통한 상대적 열손실 속도를 측정하였다. 동일한 두께의 필름인 경우에 상대적 열손실 속도는 PE>EVA>PVC의 순으로 감소하였고, silica gel보온재가 첨가된 필름의 열손실 속도는 보온재 무첨가 필름보다 역시 감소함을 보여주었다. 이러한 측정결과는 재질에 따른 필름 보온성에 관한 이미 상식화한 사실과 부합되는 것으로서, 본 고안 장치가 여러 가지 상품화된 하우스용 필름의 선별에 쉽게 이용될 수 있음을 시사한다.

  • PDF