• 제목/요약/키워드: thermal bridge

검색결과 297건 처리시간 0.028초

구치부 심미수복, 풀지르코니아 크라운의 파절원인과 그 해결방안 (Factors affecting fracture of full contour monolithic zirconia dental prosthesis in laboratory process)

  • 이수영
    • 대한심미치과학회지
    • /
    • 제23권2호
    • /
    • pp.77-79
    • /
    • 2014
  • There are several factors affected fractures of full contour zirconia (FCZ) dental prosthesis in laboratory process. First, residual moisture can cause zirconia cracks. Complete dry is requisite before zirconia sintering to prevent zirconia cracks. Second, slow cooling rate is essential to prevent cracks during zirconia sintering process. Cracks in bridge pontic area, thick dental implant prosthesis can be prevented by slow cooling rate such as 3 degree Celsius per minute during zirconia sintering. Third, slow heating rate and slow cooling rate during staining and glazing procedure is necessary to inhibit thermal shock of sintered dental zirconia. Lower preheat temperature of porcelain furnace is recommended. Finally, using diamond disc to open embrasure can lead cracks.

수소-천연가스 혼합연료기관의 최적 수소 분사율 검토 (An Investigation on the Proper Hydrogen Mixing Rate in Heavy-Duty Hydrogen-CNG Engine)

  • 임희수;김윤영;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제15권2호
    • /
    • pp.89-97
    • /
    • 2004
  • A heavy duty hydrogen enriched CNG engine has the possibility to obtain stable operation at ultra lean condition and to reduce emission extremely. And it can also serve as a so called bridge technology between the current fossil fueled engine and the future hydrogen power system. The emission, torque and brake thermal efficiency characteristics of a heavy-duty hydrogen-CNG engine were investigated to determine the proper mixing rate of hydrogen and CNG. It was found that the proper mixing rates at ${\lambda}=1.4$ and ${\lambda}=1.6$ were around 20% and 30% for hydrogen addition rate respectively.

Experimental Study on Single Bubble Growth Under Subcooled, Saturated, and Superheated Nucleate Pool Boiling

  • Kim Jeong-Bae;Lee Jang-Ho;Kim Moo-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제20권5호
    • /
    • pp.692-709
    • /
    • 2006
  • Nucleate pool boiling experiments with constant wall temperature were performed using pure R1l3 for subcooled, saturated, and superheated pool conditions. A microscale heater array and Wheatstone bridge circuits were used to maintain the constant wall temperature and to measure the instantaneous heat flow rate accurately with high temporal and spatial resolutions. Images of bubble growth were taken at 5,000 frames per second using a high-speed CCD camera synchronized with the heat flow rate measurements. The bubble geometry was obtained from the captured bubble images. The effect of the pool conditions on the bubble growth behavior was analyzed using dimensionless parameters for the initial and thermal growth regions. The effect of the pool conditions on the heat flow rate behavior was also examined. This study will provide good experimental data with precise constant wall temperature boundary condition for such works.

염분에 따른 변압기유의 유전특성 (I) (The Dielectric Characteristics of Transformer Oil due to the Sodium Chloride (I))

  • 조경순;송병기;이수원;신종열;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.206-210
    • /
    • 1996
  • In order to investigate the electrical properties for transformer oils which contains a Pure sodium chloride, the dielectric properties is made researches. To measure the dielectric loss of specimen, a coaxial cylindrical liquid electrode is used, and its geometric capacitance is confirmed to 16[pF]. And the dielectric dissipation factor, tan$\delta$, is measured by using the Video Bridge 2150. The thermal static oven with an automatically static temperature controller is used so as to support specific temperature to the specimen. This experiments for measuring the dielectric lass is performed at 20-120[$^{\circ}C$] in the temperature range, 30∼1.5x10$\^$5/[Hz] in the frequency range and 300∼1500[mV] in the voltage range. The result of experiment for the movement of carrier and the physical constants to contribute dielectric properties of specimen with a pure sodium chloride.

  • PDF

대형 터빈발전기 고정자 권선의 미세구조 분석 (Microstructure Analysis of Large Turbine Generator Stator Insulations)

  • 김희동;주영호;송성일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1452-1454
    • /
    • 2002
  • Large turbine generator(rated 22kV) has failed in the stator winding area during normal operation. The capacitance and tan${\delta}$ were measured by Schering bridge in the zone 1, 2 and zone 3-6 stator windings. The capacitance and tan${\delta}$ in the zone 1, 2 of stator winding were higher than those of zone 3-6 in the stator winding. Experiments on microstructure property were conducted in the zone 1, 2 and zone 3-6 insulations, which were drawn out from stator windings of the large turbine generator. Microstructure analysis was characterized using scanning electron microscope(SEM). SEM results indicated that several isolated delaminations occurred at the interface of mica/epoxy insulations. Both thermal and mechanical aging cause the delamination.

  • PDF

의치용 수지의 온성온도가 강도에 미치는 영향 (EFFECT OF THE CURING TEMPERATURE OF DENTURE RESINS ON THE STRENGTH)

  • 선우양국
    • 대한치과의사협회지
    • /
    • 제16권3호통권106호
    • /
    • pp.235-237
    • /
    • 1978
  • Dr. Walter Wright first presented the results of his studies on acrylic resins in July, 1937. The use of resins for adaptation in inlay and crown and bridge prosthesis was first reported in June 1940 by Harris. There has been now and acceptable list of several physical and mechanical properties of acrylic resins which have been studied to a considerable extent by various researchers, or determined from clinical experience. They include; pleasant esthetics, taste, odor, cleanliness, compatibility with oral tissue, dimensional stability, water sorption by imbibition, hardness, ease and success of repair, weight, thermal coefficient of expansion and strength to resist functional stress. The author carried a series of experiments forward to check the strength. Specimens which were cured at boiling temperature showed weaker strength than those ones which were cured at 72℃.

  • PDF

발전기 고정자 권선 절연재료의 초기특성 (Initial Characteristics of Generator Stator Insulations)

  • 이영준;김희동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2110-2113
    • /
    • 1999
  • This paper describes the initial characteristics of turbine generators at the Taean thermal power plant #4 and Wolsong nuclear power plant #2. The turbine generators had been in service for two years. The insulation diagnostic tests included measurements of insulation resistance, polarization index, ac current, dissipation factor($tan{\delta}$) and partial discharges (PD). The values of ac current and tan a were measured by Schering bridge. PD measurements were conducted using digital PD detector. The variation of $tan{\delta}$ and PD was confirmed in two generator stator insulations.

  • PDF

장대레일이 설치된 교량에서의 축방향 변위 및 축력 변화 연구 (A Study of Longitudinal Forces and Displacements in a Multi-Span Bridge Equipped with a CWR Track)

  • 이주헌;허영
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 춘계학술대회 논문집
    • /
    • pp.442-449
    • /
    • 1999
  • Due to temperature variations, considerable longitudinal rail forces and displacements may develop in continuous welded rail(CWR) track on long-span bridges or viaducts. Excessive relative displacements between sleepers and ballast bed may disturb the stable position of the track in the ballast which results in a lower frictional resistance. Generally, these problems are solved by installing rail expansion devices. However the application of expansion devices in high-speed tracks on existing bridges, as a means to prevent excessive longitudinal displacements and forces, is not attractive method due to comfort, safety and maintenance aspects. An alternative and very effective solution is possibly the use of so-called zero longitudinal restraint(ZLR) fastenings over some length of the track. The calculations, carried out in this respect, show a considerable reduction of track displacements, track forces, and the relative sleeper/ballast displacements. This reduction depends on the length over which these fastenings are installed. In this paper calculations of the longitudinal displacments and forces in a CWR track and substructure resulting from thermal, mechanical and kinematical loads were carried out using the FEM analysis program LUSAS

  • PDF

Synthesis and Characterization of Nonlinear Optical Polymers Having Quinoline-based Chromophores

  • Kim, Min-Ho;Jin, Jung-Il;Lee, Chul-Joo;Kim, Nak-Joong;Park, Ki-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권7호
    • /
    • pp.964-970
    • /
    • 2002
  • We synthesized three kinds of chromophores incorporating aromatic quinoline unit as a $\pi-conjugated$ bridge in order to prepare more thermally stable nonlinear optical (NLO) chromophores than general stilbene unit. The NLO poly(methylmethacrylate) copolymer, polyimides, and polyester were successfully synthesized by these corresponding quinoline-based monomers. Their physical and optical properties were investigated by thermogravimetry, gel permeation chromatography, ultraviolet-visible spectroscopy, second harmonic generation (SHG) and electro-optic (EO) measurement. All the polymers exhibited better thermal stability,however their NLO activity was a little lower than that of general stilbene-based NLO polymers. Among three kinds of polymers, the PMMA copolymer with quinoline chromophores had the largest SHG coefficient d33 value of 27 pm/V (at 1.064 $\mu\textrm{m})$ and EO coefficient r33 value of 6.8 pm/V (at 1.3 $\mu\textrm{m}$).

A Study on the POE-based Energy Utilization Satisfaction Analysis for Passive House in Germany

  • 정해조;김수용;양진국
    • 한국태양에너지학회 논문집
    • /
    • 제36권3호
    • /
    • pp.17-23
    • /
    • 2016
  • Passive House represents energy-saving technologies. It aims to save energy and provide comfort to the dwellers. The design and construction began in Germany, where it is commonly observed. In South Korea, implementation of the Passive House concept is difficult because of high construction costs and technological problems. This study performed a POE analysis to analyze the extents of satisfaction and knowledge about Passive House among those who live in them in Germany. The results found high satisfaction with functional aspects, such as ventilation, windows, doors, and the thermal bridge. These research results will provide application criteria for Passive House construction in South Korea.