• 제목/요약/키워드: therapeutic radiology

검색결과 806건 처리시간 0.025초

작은 블럭을 이용한 판톰 내에서의 판톰 산란 인자(Sp Factor)측정법 (Determination of the Phantom Scatter Factor ($S_P\;Factor$) using a small Block in the Phantom)

  • 이병용;홍석민;김재성;최은경;장혜숙;이명자;전하정
    • Radiation Oncology Journal
    • /
    • 제10권1호
    • /
    • pp.121-123
    • /
    • 1992
  • 판톰 산란 인자($S_{p}$) 측정을 위한 새로운 방법을 소개한다. 측정용 전리함을 가릴 수 있는 블럭을 이용하여 $S_{p}$인자를 구할 수 있음을 이론적으로 증명하였으며, 이의 검증을 위해 $^{60}Co$을 이용하여 실험하였다. 이론값과 실험값과의 차이는 1%를 넘지않았다. 이 새로운 방법을 이용하면 고에너지 광자선측정에서 문제로 대두되고 있는 공기중 측정이 필요 없으며, 작은 블럭 차폐물만을 이용하여 $S_{p}$인자를 구할 수 있음을 확인하였다.

  • PDF

6MV 선형가속기를 사용한 유방암 치료 (A Trial of 6-MV Linear Accelerator Radiation Therapy (RT) for Breast Cancer)

  • 윤세철;권형철;오윤경;김종우;박용휘
    • Radiation Oncology Journal
    • /
    • 제2권2호
    • /
    • pp.303-309
    • /
    • 1984
  • Radiation therapy(RT) has been used in the treatment of breast cancer for over 80years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internal mammary nodes (IM) and supraclavicular nodes (SCL). Authors tried three-field technique for the treatment of breast cancer using 6-MV linear accelerator, exclusively the department of radiology. Kang-Nam St. Mary's Hospital, at Catholic Medical College. The field junction was checked by a Phantom study and radiation doses measured by film densitometry and TLD. The 3 fields we used in this study were two isocentric opposing tangential fields encompassing the breast, chest wall and occasionally IM and one single anterior field encompassing the axilla and SCL. sing appropriate beam blocks and boluses, we were able to avoid unwanted intrinsic divergency of photon beam. Blocking also enabled us to set-up precise radiation field with ease.

  • PDF

치료계획용 컴퓨터를 이용한 부정형조사면의 선량분포에 관한 실험 (An Experimental Dosimetry of Irregularly Shaped Fields Using Therapeutic Planning Computer)

  • 권형철;오윤경;윤세철;박용휘
    • Radiation Oncology Journal
    • /
    • 제2권2호
    • /
    • pp.281-285
    • /
    • 1984
  • The authors have intended to measure intrinsic dose distribution by Farmer dosimeter in irregularly shaped fields such as L.M and T shape models in order to determine dose inhomogeneity in those models. We made 2 off·axis points in each model and measured the depth dose at 1.5, 5 and 9cm below surface. The results showed $l\~3\%$ dose discrepancy between 2 points. We also measured the depth dose by geometric approximation and computer calculation in those models, and came to the conclusion that computer calculation using Clarkson's principle is simpler and the measurements are closer to the ideal data obtained by the experiment in three models of irregularly shaped fields than those of geometric approximation method.

  • PDF

비식도 종양에 의한 식도의 협착 및 폐쇄 (Esophageal Steno-Obstruction due to Nonesophageal Tumors)

  • 오윤경;길학준;정수미;윤세철;신경섭;박용휘
    • Radiation Oncology Journal
    • /
    • 제5권2호
    • /
    • pp.111-117
    • /
    • 1987
  • 암 환자에 있어서 영양상태는 치료에 대한 반응과 생존기간에 영향을 미치는 인자가 된다. 그래서 연하곤란은 암 환자에 중요한 영향을 끼친다고 할 수 있다. 저자들은 1983년 3월부터 1987년 3월까지 가톨릭의대 강남성모병원 방사선치료실에서 방사선 치료를 받은 1,400명의 환자 중 연하곤란 및 호흡기계 문제로 방사선 치료를 받았던 식도암 이외의 암에 의한 식도의 헙착 및 폐쇄를 일으킨 환자 16예를 대상으로 이들의 특성과 식도의 협착 및 폐쇄에 대한 방사선 치로의 효과 및 생존기간을 후향성으로 분석하여 보았다. 1. 방사선치료를 받은 환자 중 빈도는 $1\%$이었다. 2. 가장 빈번한 원인은 폐암 (14/16)이었고, 식도 중부 (14/16)가 가장 흔하게 침범되는 부위였다. 3. 방사선 치료에 대한 반응은 연하곤란의 정도와 2주 간격으로 촬영한 바륨조영사진으로 평가하였는데 계획된 방사선 치료를 종료한 환자들의 $80\%$(8/10)에서 반응을 보였다. 4. 반응이 시작되는 선량은 1,000cGy-6,010cGy의 범위에 들어 있으며 중앙치는 2,880cGy였고 평균치는 2,993 cGy였다. 5. Kaplan-Meier 방식에 의한 15주와 30주 생존율은 전예에서는 $60\%$$46\%$였고 계획된 방사선 치료를 종료한 환자들에서는 $77\%$$51\%$였다. 6. 4예에서는 연하곤란의 재발 없이 90주 이상 생존하고 있다.

  • PDF

편평상피 세포성 폐암의 방사선치료 실패 양상 (The Pattern of Failure after Definitive Radiotherapy for Squamous Cell Carcinoma of the Lung)

  • 장양숙;김재철;류삼열;박인규
    • Radiation Oncology Journal
    • /
    • 제7권1호
    • /
    • pp.45-50
    • /
    • 1989
  • From Feb.1985 to Feb.1988,76 patients with squamous cell carcinoma of the lung treated at the Department of Therapeutic Radiology in Kyungpook National University Hospital were available for the analysis of this study. All patients received radiation of 4000cGy-6600cGy with curative aim. The overall rate of complete response was 25.0% and partial response was 452.6% The complete and partial regression of tumor was 14.3% in patients treated with dose below 5000cGy and 84.1% in the group treated with dose above 5000cGy (p<0.01). The complete response was seen only in the group of patients received radiation at least 6000cGy. The patterns of failure were as follows. The rate of initial intrathoracic recurrence was 52.6% in patients with complete response. The overall rate of failure was 68.8%. Distant metastasis was found in 47.4% of patients. Bone, contralateral lung, and brain were common metastatic sites in decreasing order All of the distant metastases and 80% of local recurrences were found within the first year after treatment.

  • PDF

ML-15MDX 술중조사용 Applicator에 의한 전자선선량 특성 (Dose Characteristics for IORT Applicator of ML-15MDX Electron Beam)

  • 최태진;이호준;김영애;김진희;김옥배
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.455-461
    • /
    • 1993
  • Experimental measurements of dose characteristics with pentagonal applicator at nominal energy of 4, 6, 9, 12 and 15 MeV electron beam were performed for intraoperative radiotherapy (IORT) in ML-15MDX linear accelerator. This paper presents the percent depth dose, surface dose, beam flatness and output factors of using the IORT applicator in different electron beam energy. The output factor showed as a 24 percent higher in IORT applicator than that of reference $10{\times}10cm^2$ applicator. The surface dose of using the IORT applicator showed 7.7 and 2.7 percent higher than that of reference field in 4 and 15 MeV electron beam, respectively. In our experiments, the variation of percent depth dose was very small but the output factor and flatnees at 0.5 cm depth have showed a large value in IORT applicator.

  • PDF

중앙성육아종의 방사선치료 (Radiation Therapy (RT) of Midline Granuloma)

  • 권형철;오윤경;길학준;윤세철;박용휘
    • Radiation Oncology Journal
    • /
    • 제4권2호
    • /
    • pp.135-139
    • /
    • 1986
  • 중앙성육아종 환자 7예에 대하여 가톨릭의대 강남성모병원 방사선치료실에서는 1983년 3월 부터 1986년 6월까지, 사이에 외부방사선치료를 시행하였다. 임상증상으로서, 모든 환자에서 침습부위에 궤사를 동반한 부비동염 증세를 보였고, 1예에선 대장(결장)병변도 나타냈다. 방사선치료는 6MV선형가속기를 사용하여 비강 및 부비동 부위를 포함하는 상기도 부위에 $2\~3$문 조사를 실시하여, 총선량 $4,000\~5,000cGy/5\~6$주를 조사하였다. 방사선치료 반응으로서 방사선치료 종료 후 $1.5\~20$개월 추적관찰 한 결과 완전 및 부분관해가 각각 3예, 대장부위에 병변을 보였던 1예에선 병이 진행되고 있음이 관찰되었다.

  • PDF

방사선 전신 조사 : 기본 자료 측정 및 생체내에서 선량 측정 (Total Body Irradiation Technique : Basic Data Measurements and In Vivo Dosimetry)

  • 최동락;최일봉;강기문;신경섭;김춘추
    • Radiation Oncology Journal
    • /
    • 제12권2호
    • /
    • pp.219-223
    • /
    • 1994
  • This paper describes the basic data measurements for total body irradiation with 6 Mv photon beam including compensators design. The technique uses bilateral opposing fields with tissue compensators for the head, neck, lungs, and legs from the hip to toes. In vivo dosimetry was carried out for determining absorbed dose at various regions in 7 patients using diode detectors(MULTIDOSE,k Model 9310, MULTIDATA Co., USA). As a results, the dose uniformity of${\pm}3.5{\%}$(generally, within${\pm}10{\%}$can be achieved with out total body irradiation technique.

  • PDF