• 제목/요약/키워드: the size of finger

검색결과 170건 처리시간 0.021초

A Secure Authentication Method for Smart Phone based on User's Behaviour and Habits

  • Lee, Geum-Boon
    • Journal of the Korea Society of Computer and Information
    • /
    • 제22권9호
    • /
    • pp.65-71
    • /
    • 2017
  • This paper proposes a smart phone authentication method based on user's behavior and habit that is an authentication method against shoulder surfing attack and brute force attack. As smart phones evolve not only storage of personal data but also a key means of financial services, the importance of personal information security in smart phones is growing. When user authentication of smart phone, pattern authentication method is simple to use and memorize, but it is prone to leak and vulnerable to attack. Using the features of the smart phone pattern method of the user, the pressure applied when touching the touch pad with the finger, the size of the area touching the finger, and the time of completing the pattern are used as feature vectors and applied to user authentication security. First, a smart phone user models and stores three parameter values as prototypes for each section of the pattern. Then, when a new authentication request is made, the feature vector of the input pattern is obtained and compared with the stored model to decide whether to approve the access to the smart phone. The experimental results confirm that the proposed technique shows a robust authentication security using subjective data of smart phone user based on habits and behaviors.

Microfluidic LOC System (Microfluidic LOC 시스템)

  • Kim, Hyun-Ki;Gu, Hong-Mo;Lee, Yang-Du;Lee, Sang-Yeol;Yoon, Young-Soo;Ju, Byeong-Kwon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.906-911
    • /
    • 2004
  • In this paper, we used only PR as etching mask, while it used usually Cr/AU as etching mask, and in order to fabricate a photosensor has the increased sensitivity, we investigated on the sensitivity of general type and p-i-n type diode. we designed microchannel size width max 10um, min 5um depth max 10um, reservoir size max 100um, min 2mm. Fabrication of microfluidic devices in glass substrate by glass wet etching methods and glass to glass fusion bonding. The p-i-n diode has higher sensitivity than photodiode. Considering these results, we fabricated p-i-n diodes on the high resistive($4k{\Omega}{\cdot}cm$) wafer into rectangle and finger pattern and compared internal resistance of each pattern. The internal resistance of p-i-n diode can be decreased by the application of finger pattern has parallel resistance structure from $571\Omega$ to $393\Omega$.

  • PDF

Obturation efficiency of non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments (0.06-경사도의 니켈-티타늄 기구로 형성된 레진 만곡근관에서 비표준화 GUTTA-PERCHA CONE의 근관충전 효율)

  • Lee, Eun-Ah;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • 제30권2호
    • /
    • pp.79-85
    • /
    • 2005
  • The purpose of this study was to evaluate the obturation efficiency of a non-standardized gutta-percha cone in curved root canals prepared with 0.06 taper nickel-titanium instruments. Sixty simulated curved root canals in clear resin blocks were prepared with crown-down technique using 0.06 taper rotary $ProTaper^{TM}$and ProFile (Dentsply-Maillefer) until apical canal was size 30. Root canals were randomly divided into 4 groups of 15 blocks and obturated with cold-laterally compacted gutta-percha technique by using either a non-standardized size medium gutta-percha cone or an ISO-standardized size 30 one as a master cone. Gutta-percha area ratio were calculated at apical levels of 1, 3 and 5 mm using AutoCAD 2000 after cross-sectioning, and the data were analyzed with one-way and two-way ANOVAs and Duncan's multiple range test. Non-standardized size medium cone groups showed significantly higher gutta-percha area ratio than standardized cone groups at all apical levels (p < 0.01). Non-standardized cone groups used significantly less accessory cones than standardized cone groups (p < 0.01).

Overexpression of three related root-cap outermost-cell-specific C2H2-type zinc-finger protein genes suppresses the growth of Arabidopsis in an EAR-motif-dependent manner

  • Song, Sang-Kee;Jang, Hyeon-Ung;Kim, Yo Han;Lee, Bang Heon;Lee, Myeong Min
    • BMB Reports
    • /
    • 제53권3호
    • /
    • pp.160-165
    • /
    • 2020
  • The root meristem of Arabidopsis thaliana is protected by the root cap, the size of which is tightly regulated by the balance between the formative cell divisions and the dispersal of the outermost cells. We isolated an enhancer-tagged dominant mutant displaying the short and twisted root by the overexpression of ZINC-FINGER OF ARABIDOPSIS THALIANA1 (ZAT1) encoding an EAR motif-containing zinc-finger protein. The growth inhibition by ZAT1 was shared by ZAT4 and ZAT9, the ZAT1 homologues. The ZAT1 promoter was specifically active in the outermost cells of the root cap, in which ZAT1-GFP was localized when expressed by the ZAT1 promoter. The outermost cell-specific expression pattern of ZAT1 was not altered in the sombrero (smb) or smb bearskin1 (brn1) brn2 accumulating additional root-cap layers. In contrast, ZAT4-GFP and ZAT9-GFP fusion proteins were distributed to the inner root-cap cells in addition to the outermost cells where ZAT4 and ZAT9 promoters were active. Overexpression of ZAT1 induced the ectopic expression of PUTATIVE ASPARTIC PROTEASE3 involved in the programmed cell death. The EAR motif was essential for the growth inhibition by ZAT1. These results suggest that the three related ZATs might regulate the maturation of the outermost cells of the root cap.

Refinements of Adipofascial flap for Small Defects of Fingers and Toes: Indication and Surgical Tips

  • Chung, Yoon-Kyu;Choi, Jin-Hee;Kim, Jiye;Chung, Seum
    • Archives of Reconstructive Microsurgery
    • /
    • 제25권2호
    • /
    • pp.25-28
    • /
    • 2016
  • Purpose: Reconstruction of small defects of the dorsal fingers and toes is a challenging task. Although adipofascial flap is widely used for these areas, additional refinements are warranted. In this paper, we define the appropriate defect size in the finger and toes that can be treated with the adipofascial flap, refine its surgical indications and present a few surgical tips. Materials and Methods: Twelve patients with dorsal defects of the fingers and toes were treated with a random-type adipofascial turn-over flap and skin graft. If the defect area exceeded the size that could be covered by a conventional design, the flap base was designed in oblique or curvilinear fashion to lengthen the flap. For accurate defect coverage, the width of the flap base was designed in an asymmetrical shape depending on the defect configuration, varying the width from 0.3 to 1.0 cm, as opposed to the standard 0.5 to 1.0 cm width. Moreover, the lateral limit of the flap was defined as the lateral axial line. The size of the defect ranged from $3.0{\times}1.7cm$ to $1.5{\times}1.3cm$. Results: All flaps survived completely. Gliding function of the hand was well preserved and there was no evidence of tendon adhesion. Conclusion: The small defect in the dorsal finger and toe can be defined as less than one phalanx-length, measuring about $3.0{\times}2.0cm$ in size. If the defect exceeds this dimension, it is recommended that a different option be considered. We believe the adipofascial flap is an excellent option for treating small defects.

A Compact Low-Power Shunt Proximity Touch Sensor and Readout for Haptic Function

  • Lee, Yong-Min;Lee, Kye-Shin;Jeong, Taikyeong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.380-386
    • /
    • 2016
  • This paper presents a compact and low-power on-chip touch sensor and readout circuit using shunt proximity touch sensor and its design scheme. In the proposed touch sensor readout circuit, the touch panel condition depending on the proximity of the finger is directly converted into the corresponding voltage level without additional signal conditioning procedures. Furthermore, the additional circuitry including the comparator and the flip-flop does not consume any static current, which leads to a low-power design scheme. A new prototype touch sensor readout integrated circuit was fabricated using complementally metal oxide silicon (CMOS) $0.18{\mu}m$ technology with core area of $0.032mm^2$ and total current of $125{\mu}A$. Our measurement result shows that an actual 10.4 inches capacitive type touch screen panel (TSP) can detect the finger size from 0 to 1.52 mm, sharply.

Four degrees of freedom robot gripper for assembly robots (SCARA robot를 위한 4자유도 end-effector 개발)

  • ;Besant, C.S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1991년도 한국자동제어학술회의논문집(국내학술편); KOEX, Seoul; 22-24 Oct. 1991
    • /
    • pp.511-516
    • /
    • 1991
  • A new end-effector has been devised and the problems resulted from using it with SCARA robots are discussed. The end effector has two modules: one composed of two ultrasonic motors and two encoders for controlling each finger, and the other module composed of two ultrasonic motors and two encoders for controlling the wrist. The wrist module adds two degrees of freedom to the SCARA type robot, which generally has four degrees of freedom. With independent finger actuation and touch sensors, the gripper under computer control can feedback information about part size and part presence. Ultrasonic motors with high torque and slow motion characteristics are used. The principle of ultrasonic motors is explained and the servo characteristics of ultrasonic motors are studied. They are controlled by the general motion controller (Hewlett Packard HCTL-1000) which is linked to an IBM-PC AT.

  • PDF

A Study on User Behavior of Input Method for Touch Screen Mobile Phone (터치스크린 휴대폰 입력 방식에 따른 사용자 행태에 관한 연구)

  • Jun, Hye-Sun;Choi, Woo-Sik;Pan, Young-Hwan
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2008년도 학술대회 2부
    • /
    • pp.173-178
    • /
    • 2008
  • Due to a rapid increase in demand for bigger-screen-equipped mobile phones in recent years, many big-name-manufactures have been releasing touch-screen-enabled devices. In this paper, various touch-screen-input methods have been summarized into 6 different categories. How? By tracing each user's finger print path, user's input pattern and behavior have been carefully recorded and analyzed. Through this analysis, what to be considered before designing UI is presented in great details.

  • PDF

The Effect of Hand and Finger Exercise on Grip Strength and Pinch Pressure in Elderly Women (손과 손가락 근관절운동이 노년기 여성의 악력과 잡기력에 미치는 영향)

  • Kim, Jong-Im;Kim, Hyun-Li;Kim, Sun-Ae
    • Journal of muscle and joint health
    • /
    • 제9권1호
    • /
    • pp.18-27
    • /
    • 2002
  • Introduction : Exercise has been suggested as an important nursing strategy in which to help elderly maintain functional performance and to enhanced quality of life. Most of exercise study has been reported on fitness exercise such as walking, swimming, dance etc for health of elderly. There have been few reports about exercise on the promotion of small and fine movement of elderly. The purpose of this pilot study was to determine an effect of 6 weeks hand and finger exercise in home to improve hand muscle strength such as grip strength and finger pinch pressure. Materials and Methods Design: This pilot study was used one group pre and post-test design. Sample: Twelve elderly women above 60 years of age or older living in community were selected by convenient sampling. Procedure: Signed informed consent was obtained prior to participate in this study. The authors met elderly and taught hand and finger exercise, daily a week for 6 weeks, within 30 minutes per session. But exercise frequency and strength were not same. Instruments: Left and right grip strength were measured by Bulb Dynamometer(made in USA) and left and right pinch pressure were measured by Baseline Hydraulic Pinch Gauge(made in USA). Data analysis: Discriptive data analyses were performed on all variables. Wilcoxon matched-pairs Signed-Ranks test were used to find difference of grip strength and pinch pressure between pre and post exercise using SPSS 10.0 for Window. Results: Samples age ranged from 60 to 73, Mean age was 65.3. All were women. Ten elderly were diagnosed osteoarthritis and one had DM. After six weeks hand and finger exercise, Left and right grip strength were higher than those of before exercise(Z=-2.667, P<0.01 ; Z=-3.065, p<0.01). And left pinch pressure after hand and linger exercise were higher than that of before pinch pressure (Z=-2.315, p<0.05). But Right pinch pressure was not shown significant change(Z=-1.099, p>0.05). Conclusions: Although this study was limited by the sample size and design, the findings provide some important implications for community based exercise nursing intervention. Short term (six weeks) exercise of hand and linger is shown to be useful as nursing intervention to maintain routine daily activities such as eating, writing, grip something for elderly.

  • PDF

A study on the determination of an optimal handle diameter for a signal billy (신호봉 손잡이의 최적 굵기 결정에 관한 연구)

  • 변승남;이동훈
    • Journal of the Ergonomics Society of Korea
    • /
    • 제16권1호
    • /
    • pp.15-27
    • /
    • 1997
  • The objectives of this study were twofold; (1) to determine an optimal handle size of a signal billy, based on the subjective assessment of grip comfort and (2) to investigate the relationship between hand anthropometry and the optimal handle size. Thirty-seven university male students were asked to rate seven cylindrical handles of different diameters in barehanded and gloved conditions, respectively. Among these handles, 3.5cm diameter of the handle size was found to be the most comfortable, in both bardhanded and gloved conditionsl. However, no statistically significant reduction in grip comfort occurred within handle diameter ranging from 2.5cm to 4.0cm. As the handle diameter was deivated from the range, grip discomfort in creased significantly. A Spearman rank correlation coefficient test revealed that hand anthropometries such as finger lengths, hand circumference, and hand thickness were statistically significant factors on the determination of the optimal handle size. The implications of these findings were discussed. The results of this study can be used as guidelines in designing the hand tools for power grip.

  • PDF